Lipoprotein(a)-cholesterol and coronary heart disease in the Framingham Heart Study.

Abstract:

BACKGROUND:Increased plasma lipoprotein(a) [Lp(a)] concentrations have been reported to be an independent risk factor for coronary heart disease (CHD) in some prospective studies, but not in others. These inconsistencies may relate to a lack of standardization and the failure of some immunoassays to measure all apolipoprotein(a) isoforms equally. METHODS:We measured plasma Lp(a)-cholesterol [Lp(a)-C] in a Caucasian population of offspring and spouses of the Framingham Heart Study participants, using a lectin-based assay (LipoproTM). We compared the prevalence of increased Lp(a)-C to the presence of sinking pre-beta-lipoprotein (SPB). We also related Lp(a)-C concentrations to the prevalence of CHD risk in the entire population. RESULTS:The mean (+/- SD) Lp(a)-C concentration in the Framingham population (n = 3121) was 0.186 +/- 0.160 mmol/L, with no significant gender or age differences. The mean Lp(a)-C concentrations in the absence or presence of SPB were 0.158 +/- 0. 132 mmol/L and 0.453 +/- 0.220 mmol/L, respectively (P <0.0001). The mean Lp(a)-C concentration in men with CHD (n = 156) was 0.241 +/- 0. 204 mmol/L, which was significantly (P <0.001) higher, by 34%, than in controls. The odds ratio for CHD risk in men with Lp(a)-C >/=0. 259 mmol/L (>/=10 mg/dL), after adjusting for age, HDL-cholesterol, LDL-cholesterol, smoking, diabetes, blood pressure, and body mass index, was 2.293 (confidence interval, 1.55-3.94; P <0.0005). Lp(a)-C values correlated highly with a Lp(a)-mass immunoassay [ApotekTM Lp(a); r = 0.832; P <0.0001; n = 1000]. CONCLUSIONS:An increased Lp(a)-C value >/=0.259 mmol/L (>/=10 mg/dL) is an independent CHD risk factor in men with a relative risk of more than 2, but was inconclusive in women. Lp(a)-C measurements offer an alternative to Lp(a)-mass immunoassays and can be performed on automated analyzers.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Seman LJ,DeLuca C,Jenner JL,Cupples LA,McNamara JR,Wilson PW,Castelli WP,Ordovas JM,Schaefer EJ

subject

Has Abstract

pub_date

1999-07-01 00:00:00

pages

1039-46

issue

7

eissn

0009-9147

issn

1530-8561

journal_volume

45

pub_type

临床试验,杂志文章
  • Low HDL Cholesterol and High Risk of Autoimmune Disease: Two Population-Based Cohort Studies Including 117341 Individuals.

    abstract:BACKGROUND:HDL is quantitatively the most important lipoprotein in most species and mechanistic evidence points toward a role for HDL in normal immune function. We tested the hypothesis that concentrations of HDL cholesterol are associated with risk of autoimmune disease. METHODS:From 2 studies of the general populati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.299636

    authors: Madsen CM,Varbo A,Nordestgaard BG

    更新日期:2019-05-01 00:00:00

  • Measurement of urinary oxalate and citrate by capillary electrophoresis and indirect ultraviolet absorbance.

    abstract::We describe a method for measuring urinary oxalate and citrate with capillary electrophoresis (CE) and indirect ultraviolet absorbance detection. Sample preparation is minimal, requiring an acidification, brief centrifugation, and dilution. The method is rapid, with oxalate and citrate having mean migration times of 4...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Holmes RP

    更新日期:1995-09-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Highly sensitive enzyme immunoassay of proinsulin immunoreactivity with use of two monoclonal antibodies.

    abstract::A highly sensitive two-site sandwich ELISA measuring total proinsulin immunoreactive material in serum or plasma was developed. The assay was based on two monoclonal antibodies, an anti-C-peptide antibody bound to a microtest plate and a biotin-labeled anti-insulin antibody. The detection limit (3 SD above zero value)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kjems LL,Røder ME,Dinesen B,Hartling SG,Jørgensen PN,Binder C

    更新日期:1993-10-01 00:00:00

  • Delayed cytokine mRNA expression kinetics after T-lymphocyte costimulation: a quantitative measure of the efficacy of cyclosporin A-based immunosuppression.

    abstract:BACKGROUND:Because cyclosporin A (CsA) and glucocorticoids inhibit the production of interleukin-2 (IL-2) and other cytokines, quantitative analysis of cytokine mRNA might constitute a pharmacodynamic measure for immunosuppressive drug effects. We investigated whether immunosuppressive drugs influence cytokine mRNA exp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Härtel C,Fricke L,Schumacher N,Kirchner H,Müller-Steinhardt M

    更新日期:2002-12-01 00:00:00

  • Identification of a new metabolite of astilbin, 3'-O-methylastilbin, and its immunosuppressive activity against contact dermatitis.

    abstract:BACKGROUND:Astilbin is a flavonoid isolated from the rhizome of Smilax glabra. In a previous study, we revealed its unique immunosuppressive activity, a selective inhibition against activated T lymphocytes. This characteristic of astilbin is beneficial for the treatment of human immune diseases. METHODS:We incubated a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.077297

    authors: Guo J,Qian F,Li J,Xu Q,Chen T

    更新日期:2007-03-01 00:00:00

  • Making TDM work to optimize cancer chemotherapy: a multidisciplinary team approach.

    abstract::Several factors can limit the use of therapeutic drug monitoring (TDM) for cancer chemotherapeutic agents, including poorly defined concentration-effect relationships for many antineoplastic agents. This is further complicated by cancer being a highly heterogeneous group of diseases, each of which may have a unique co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hon YY,Evans WE

    更新日期:1998-02-01 00:00:00

  • Long-term aspirin and clopidogrel response evaluated by light transmission aggregometry, VerifyNow, and thrombelastography in patients undergoing percutaneous coronary intervention.

    abstract:BACKGROUND:A reduced response to aspirin and clopidogrel predicts ischemic events, but reliable tests are needed to identify low responders. We compared 3 platelet-function tests during long-term dual treatment with aspirin and clopidogrel. METHODS:Patients who underwent a percutaneous coronary intervention and were r...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.137471

    authors: Madsen EH,Saw J,Kristensen SR,Schmidt EB,Pittendreigh C,Maurer-Spurej E

    更新日期:2010-05-01 00:00:00

  • Laboratory evaluation of the Greiner G-400 discrete selective multichannel analyzer.

    abstract::We evaluated the new Greiner G-400 selective multichannel analyzer. Thirty different tests can be run in combination profile and single-test mode at a rate between 150 and 300 tests per hour. The new photometer allows kinetic and equilibrium (endpoint) measurements. The G-400 analyzer demonstrated excellent precision,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Degiampietro P,Peheim E,Colombo JP

    更新日期:1985-02-01 00:00:00

  • High-performance liquid affinity chromatography: rapid immunoanalysis of transferrin in serum.

    abstract::We describe a new method for quantitatively measuring substances of clinical interest by high-performance liquid affinity chromatography (HPLAC). As a model system we selected analysis for transferrin in human serum with immobilized antibodies in a high-performance liquid chromatographic system. SelectiSpher-10 Activa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ohlson S,Gudmundsson BM,Wikström P,Larsson PO

    更新日期:1988-10-01 00:00:00

  • Determination of Recent Growth Hormone Abuse Using a Single Dried Blood Spot.

    abstract:BACKGROUND:Although it is being increasingly applied, blood collection for drug testing in sport presents some logistic issues that complicate full applicability on a large scale. The use of dried blood spots (DBS) could benefit compliant blood testing considerably owing to its simplicity, minimal invasiveness, analyte...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.257592

    authors: Reverter-Branchat G,Bosch J,Vall J,Farré M,Papaseit E,Pichini S,Segura J

    更新日期:2016-10-01 00:00:00

  • The changing epidemiology of depression.

    abstract::At the clinical level, we have seen the emergence of a subspecialty of affective disorders within psychiatry. Mood clinics, depression units, and affective disorders centers are appearing in many academic and clinical settings, where clinical skill and knowledge can be concentrated and new research furthered. By using...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Klerman GL,Weissman MM

    更新日期:1988-05-01 00:00:00

  • Fetal DNA in maternal plasma: biology and diagnostic applications.

    abstract:BACKGROUND:Molecular analysis of plasma DNA during human pregnancy has led to the discovery that maternal plasma contains both fetal and maternal DNA. This valuable source of fetal DNA opens up new possibilities for noninvasive prenatal diagnosis. APPROACH:Published data from the last 3 years demonstrating the feasibi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Lo YM

    更新日期:2000-12-01 00:00:00

  • Simultaneous quantitation of zinc protoporphyrin and free protoporphyrin in erythrocytes by acetone extraction.

    abstract::Erythrocyte protoporphyrin content is increased in several human and veterinary disorders in which heme synthesis is disrupted. The nature of the defect determines whether zinc protoporphyrin, unchelated (free) protoporphyrin, or both are present in the erythrocytes. Extraction of the protoporphyrin into acetone/water...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hart D,Piomelli S

    更新日期:1981-02-01 00:00:00

  • Erroneous results with routine laboratory testing for immunoglobulins due to interference from circulating immune complexes in a case of hyperviscosity syndrome associated with autoimmune disease.

    abstract::A patient with the hyperviscosity syndrome exhibited very high concentrations of intermediate to small circulating immune complexes (CIC), involving 40-50% of the IgG present, with IgG rheumatoid factor activity. We demonstrate that precipitation of CIC by polyethylene glycol in the reaction mixture caused interferenc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levinson SS,Perry M,Goldman J,Nathan LE

    更新日期:1988-04-01 00:00:00

  • Liquid-chromatographic determination of free and total 3,4-dihydroxyphenylglycol and 3-methoxy-4-hydroxyphenylglycol in urine.

    abstract::We describe the conjoint measurement in urine of the alcoholic catecholamine metabolites 3,4-dihydroxyphenylglycol (DHPG) and 3-methoxy-4-hydroxyphenylglycol (MHPG). The method involves extraction with ethyl acetate and back-extraction into acetic acid (MHPG), followed by adsorption onto alumina (DHPG). The separation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Julien C,Rodriguez C,Sacquet J,Cuisinaud G,Sassard J

    更新日期:1988-05-01 00:00:00

  • Concepts for the rational selection of assays to be used in monitoring therapeutic drugs.

    abstract::As the domain of monitoring therapeutic drugs rapidly expands from experimental investigations to everyday patient care, all clinical laboratory scientists, but especially clinical chemists, must learn to deal with their involvement in this expansion. First, the theoretical concepts underlying clinical pharmacology mu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Werner M,Sutherland EW 3rd,Abramson FP

    更新日期:1975-09-01 00:00:00

  • Effects of storage time and temperature on urinary enzymes.

    abstract::We measured three renal tubular brush-border enzymes (lactate dehydrogenase, LDH, EC 1.1.1.27; gamma-glutamyltransferase, GGT, EC 2.3.2.2; and alkaline phosphatase, AP, EC 3.1.3.1) in morning urine samples from 48 healthy subjects to check whether different storage times and temperatures could modify enzyme concentrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Matteucci E,Gregori G,Pellegrini L,Navalesi R,Giampietro O

    更新日期:1991-08-01 00:00:00

  • Plasma concentrations of gamma-aminobutyric acid (GABA) and mood disorders: a blood test for manic depressive disease?

    abstract::gamma-Aminobutyric acid (GABA), an inhibitory neurotransmitter that serves about one-third of brain neurons, is involved in the development of depression and in the treatment of depression and mania with pharmacological therapy. Brain activity of GABA may be conveniently measured in plasma, and changes in plasma conce...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Petty F

    更新日期:1994-02-01 00:00:00

  • Effect of carbon cup aging on plasma zinc determination by flameless atomic adosorption spectrometry.

    abstract::Determination of zinc in blood plasma by flameless atomic absorption spectrometry is discussed, with particular reference to the protocol required for the successful use of the Varian-Techtron Carbon Rod Atomizer. Cup aging is shown to be an important factor in limiting the precision of this analytical technique and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chooi MK,Todd JK,Boyd ND

    更新日期:1975-04-01 00:00:00

  • Immunoradiometric serum ferritin concentration compared with stainable bone-marrow iron as indices to iron stores.

    abstract::Immunoradiometric analysis has made it possible to measure ferritin reliably in serum. The determination is a sensitive means of assessing body iron because concentrations of ferritin closely parallel the body's reticuloendothelial iron stores. The information provided is similar to that obtained from bone-marrow aspi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Forman DT,Vye MV

    更新日期:1980-01-01 00:00:00

  • Iron stores, blood donation, and insulin sensitivity and secretion.

    abstract:BACKGROUND:Epidemiologists have observed that blood donation is associated with decreased risk of type 2 diabetes and cardiovascular disease. METHODS:We investigated the relationship between iron stores and insulin sensitivity, after controlling for known confounding factors, and compared insulin sensitivity between b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.046847

    authors: Fernández-Real JM,López-Bermejo A,Ricart W

    更新日期:2005-07-01 00:00:00

  • Automated enzymic measurement of total cholesterol in serum.

    abstract::We describe a completely automated enzymic system for measuring total cholesterol in serum. All reagents are contained in an analytical test pack and the test is performed on Du Pont's Automatic Clinical Analyzer (aca), which mixes the sample (20 microliter) and reagents and performs the necessary absorbance measureme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rautela GS,Liedtke RJ

    更新日期:1978-01-01 00:00:00

  • Specific 125I-radioimmunoassay for cholyglycine, a bile acid, in serum.

    abstract::The concentration of the conjugated bile acid, cholylglycine, in serum is a sensitive and specific indicator of hepatic function. We describe a convenient, specific, and precise radioimmunoassay for cholylglycine, in which 125I-labeled cholylglycyltyrosine is used as tracer. In addition, a blocking agent in the buffer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miller P,Weiss S,Cornell M,Dockery J

    更新日期:1981-10-01 00:00:00

  • Fluorometric assay for phospholipase A2 in serum.

    abstract::In this fluorometric assay for phospholipase A2 (EC 3.1.1.4) in serum we use the fluorescent phospholipid analog 1-octacosanyl-2-(pyren-1-yl)hexanoyl-sn-glycero-3-phosphatid yl monomethyl ester as substrate. The optimized conditions are: 28 mumol of the substrate per liter of Tris buffer (20 mmol/L, pH 7.4). The hydro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thuren T,Virtanen JA,Lalla M,Kinnunen PK

    更新日期:1985-05-01 00:00:00

  • Iron and total iron-binding capacity in serum of patients receiving iron-dextran: Kodak Ektachem methodologies, spectrophotometry, and atomic-absorption spectrometry compared.

    abstract::We compared the analytical performance of the Kodak Ektachem XR700 assays of iron (Fe) and total iron-binding capacity (TIBC) with that of a conventional ferrozine assay (performed with a Cobas-Bio) and occasionally with that of atomic-absorption spectrometry (AAS). The correlation was modest between Kodak and Cobas-B...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vercammen M,Goedhuys W,Boeyckens A,De Roy R,Sennesael J,Sevens C,Gorus F

    更新日期:1990-10-01 00:00:00

  • Evaluation of determination of glucose in urine with some commercially available dipsticks and tablets.

    abstract::Four commercial products for urine glucose determination were evaluated and compared with a quantitative hexokinase procedure. We examined precision, sensitivity, and analytical recovery of glucose from glucose-supplemented urine samples and comparison of methods, using patients' samples. Only "Chemstrip uG" (Bio-Dyna...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bandi ZL,Myers JL,Bee DE,James GP

    更新日期:1982-10-01 00:00:00

  • Fluorometric method for phenylalanine microplate assay adapted for phenylketonuria screening.

    abstract::We adapted the method of McCaman and Robins for fluorometry of phenylalanine to a microplate assay for routine phenylketonuria screening. Sensitivity is 15 mumol/L for the plasma assay and 30 mumol/L for the dried blood-spot assay, with CV less than 10% for both assays. Results for human plasma by microplate assay cor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gerasimova NS,Steklova IV,Tuuminen T

    更新日期:1989-10-01 00:00:00

  • Improved column-chromatographic isolation of glycosylated hemoglobin S.

    abstract::We investigated glycosylated hemoglobin S by means of chromatography on Bio-Rex 70. The selected elution conditions were similar to those described by Trivelli et al. (N Engl J Med 284: 353-357, 1971), except for modified ionic strength and accurate temperature control. This enabled us to isolate a minor hemoglobin fr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cirotto C,Allegrucci M,Cartechini MG,Compagnucci P,Santeusanio F,Bolli G

    更新日期:1985-04-01 00:00:00

  • B-type natriuretic peptide forms within the heart, coronary sinus, and peripheral circulation in humans: evidence for degradation before secretion.

    abstract:BACKGROUND:The B-type natriuretic peptides (BNP and N-terminal pro-BNP) are secreted by the heart and, in the case of BNP, serve to maintain circulatory homeostasis through renal and vascular actions and oppose many effects of the renin-angiotensin system. Recent evidence suggests that in patients with severe heart fai...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.210435

    authors: Mahagamasekera PG,Ruygrok PN,Palmer SC,Richards AM,Ansell GS,Nicholls MG,Pemberton CJ,Lewis LK,Yandle TG

    更新日期:2014-03-01 00:00:00