Liquid-chromatographic separation of urinary 5-hydroxy-3-indoleacetic acid, with measurement at 254 nm.

Abstract:

:A "high-performance" liquid-chromatographic procedure for 5-hydroxy-3-indoleacetic acid is described and compared with a colorimetric method in which 1-nitroso-2-naphthol is used. The analyte and an internal standard, p-nitrobenzoic acid, were extracted into diethyl ether from urine at pH 4.0 (acidified with HCl) to which sodium chloride had been added, and the ether was back-extracted with acetate buffer, pH 9.2. Aliquots of this extract were injected into a reversed-phase liquid-chromatographic column and eluted with pH 3.5 acetate buffer/methanol (95/5 by vol); the effluent was monitored at 254 nm. The precision (CV) of the method was 11.8% at 1.8 mg/L, 5.5% at 92 mg/L. Analytical recovery averaged 84%. The colorimetric method gave higher values for the analyte than did the chromatographic method for all patients' urines.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Draganac PS,Steindel SJ,Trawick WG

subject

Has Abstract

pub_date

1980-06-01 00:00:00

pages

910-2

issue

7

eissn

0009-9147

issn

1530-8561

journal_volume

26

pub_type

杂志文章
  • Thin film biosensor for rapid visual detection of nucleic acid targets.

    abstract:BACKGROUND:We have developed a silicon-based biosensor that generates a visual signal in response to nucleic acid targets. METHODS:In this system, capture oligonucleotide probes are immobilized on the surface of the biosensor. Interaction of the capture probes with a complementary target and a biotinylated detector ol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ostroff RM,Hopkins D,Haeberli AB,Baouchi W,Polisky B

    更新日期:1999-09-01 00:00:00

  • Enzyme immunoassay for pregnancy-associated plasma protein-A.

    abstract::This enzyme immunoassay procedure for pregnancy-associated plasma protein type A involves a "sandwich"-type system in microtitration plates. One can detect 0.27 mg of the protein per liter of serum, with a between-batch CV of 10.2%, and the antiserum used does not cross react with any of the other placentally derived ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: MacDonald DJ,Mehta HC,Mack DS,Duffy T,Glen AC

    更新日期:1984-11-01 00:00:00

  • Population-based study of repeat laboratory testing.

    abstract:BACKGROUND:Test repetition could be a readily modifiable component of laboratory utilization. Laboratory test repetition has not been rigorously studied at a population-based level. Our objective was to determine the prevalence of, and charges associated with, repetition of eight common laboratory tests. METHODS:We pe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.021220

    authors: van Walraven C,Raymond M

    更新日期:2003-12-01 00:00:00

  • Microcalorimetric determination of glucose in reference samples of serum.

    abstract::Ireport a detailed series of microcalorimetric measurement of glucose concentrations in five reference samples of serum. The method utilized (a) calibration in the actual medium of analysis and (b) a correction for interferences owing to the nonspecificity of the enzyme hexokinase. The microcalorimetric results are co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Goldberg RN

    更新日期:1976-10-01 00:00:00

  • Consensus document: Hawk's Cay meeting on therapeutic drug monitoring of cyclosporine.

    abstract::The optimal measurement method and clinical application of the therapeutic drug monitoring of cyclosporine remain uncertain. At a workshop held at Hawk's Cay, FL, from January 14 to January 17, 1990, 57 scientists presented their latest research findings, either in formal papers or as discussants. Lively debate and di...

    journal_title:Clinical chemistry

    pub_type: 共识发展会议,杂志文章,评审

    doi:

    authors: Kahan BD,Shaw LM,Holt D,Grevel J,Johnston A

    更新日期:1990-08-01 00:00:00

  • Quantification of integrated HIV DNA by repetitive-sampling Alu-HIV PCR on the basis of poisson statistics.

    abstract:BACKGROUND:Quantification of integrated proviral HIV DNA by repetitive-sampling Alu-HIV PCR is a candidate virological tool to monitor the HIV reservoir in patients. However, the experimental procedures and data analysis of the assay are complex and hinder its widespread use. Here, we provide an improved and simplified...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.219378

    authors: De Spiegelaere W,Malatinkova E,Lynch L,Van Nieuwerburgh F,Messiaen P,O'Doherty U,Vandekerckhove L

    更新日期:2014-06-01 00:00:00

  • Simple method for the routine determination of betaine and N,N-dimethylglycine in blood and urine.

    abstract::A simple and convenient method using commercially available derivatization reagents is described for the measurement of betaine and N,N-dimethylglycine (DMG) in blood and urine. Precolumn derivatization of plasma or urine is performed directly in acetonitrile without extraction with p-bromophenacyl bromide and crown e...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Laryea MD,Steinhagen F,Pawliczek S,Wendel U

    更新日期:1998-09-01 00:00:00

  • Detection of heterozygotes for phenylketonuria by constant intravenous infusion of L-phenylalanine.

    abstract::We measured the rate of elimination of phenylalanine by constant intravenous infusion of L-phenylalanine in 14 parents of children with phenylketonuria and in 21 subjects with a negative family history for this disease. When reciprocals of the observed elimination rates were plotted against the reciprocals of the incr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jagenburg R,Rödjer S

    更新日期:1977-09-01 00:00:00

  • Excess osmolal gap in diabetic ketoacidosis explained.

    abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davidson DF

    更新日期:1992-05-01 00:00:00

  • uPA+/+-SCID mouse with humanized liver as a model for in vivo metabolism of exogenous steroids: methandienone as a case study.

    abstract:BACKGROUND:Adequate detection of designer steroids in the urine of athletes is still a challenge in doping control analysis and requires knowledge of steroid metabolism. In this study we investigated whether uPA(+/+)-SCID mice carrying functional primary human hepatocytes in their liver would provide a suitable alterna...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.119396

    authors: Lootens L,Meuleman P,Pozo OJ,Van Eenoo P,Leroux-Roels G,Delbeke FT

    更新日期:2009-10-01 00:00:00

  • More sensitive flameless atomic absorption analysis of vanadium in tissue and serum.

    abstract::We describe a sensitive method for the determination of vanadium in biological substances by atomic absorption spectroscopy. By using background correction and pyrolytically coated graphite tubes with flameless apparatus, this vanadium assay has a sensitivity of 65 pg and a detection limit of 30 pg, approximately sixf...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stroop SD,Helinek G,Greene HL

    更新日期:1982-01-01 00:00:00

  • Ultrasensitive measurement of delta-9-tetrahydrocannabinol with a high energy dynode detector and electron-capture negative chemical-ionization mass spectrometry.

    abstract::Plasma concentrations of delta-9-tetrahydrocannabinol, the principal psychoactive cannabinoid in marijuana, decline to values substantially less than 1 microgram/L within a few hours after a subject has smoked a marijuana cigarette. Using a single-quadrupole gas chromatograph-mass spectrometer (GC/MS) operated in the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shaw LM,Edling-Owens J,Mattes R

    更新日期:1991-12-01 00:00:00

  • Troponin T and I assays show decreased concentrations in heparin plasma compared with serum: lower recoveries in early than in late phases of myocardial injury.

    abstract:BACKGROUND:Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS:Blood samples were collected with and withou...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,多中心研究

    doi:

    authors: Gerhardt W,Nordin G,Herbert AK,Burzell BL,Isaksson A,Gustavsson E,Haglund S,Müller-Bardorff M,Katus HA

    更新日期:2000-06-01 00:00:00

  • Measurement of the complex between prostate-specific antigen and alpha1-protease inhibitor in serum.

    abstract:BACKGROUND:Prostate-specific antigen (PSA) occurs in serum both free and in complex with protease inhibitors. The complex with alpha1-antichymotrypsin (ACT) is the major form in serum, and the proportion of PSA-ACT is higher in prostate cancer (PCa) than in benign prostatic hyperplasia (BPH). PSA also forms a complex w...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Zhang WM,Finne P,Leinonen J,Vesalainen S,Nordling S,Stenman UH

    更新日期:1999-06-01 00:00:00

  • Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.

    abstract::We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilson DH,Bogacz JP,Forsythe CM,Turk PJ,Lane TL,Gates RC,Brandt DR

    更新日期:1993-10-01 00:00:00

  • Abbott TDx monoclonal antibody assay evaluated for measuring cyclosporine in whole blood.

    abstract::We report here the evaluation of the Abbott TDx assay with a monoclonal antibody for selectively quantifying cyclosporine (CsA) in whole blood. Over the clinically relevant concentration ranges, results with this assay demonstrated within- and between-run CVs of less than 2.5% and 5%, respectively; sensitivity of 25 m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Yatscoff RW,Copeland KR,Faraci CJ

    更新日期:1990-11-01 00:00:00

  • Multilayer film analysis for glucose in 1-microL samples of plasma.

    abstract::With the ultramicroanalytical system described here we can measure glucose in 1 microL of plasma or serum. The sample is placed on a dry, multilayer film element (Eastman Kodak), where a colored spot about 3.5 mm in diameter develops. The reflectance of these spots is measured with a reflectance digital matrix photome...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-12-01 00:00:00

  • Polymorphisms in inflammatory genes and the risk of ischemic stroke and transient ischemic attack: results of a multilocus genotyping assay.

    abstract:BACKGROUND:Single-nucleotide polymorphisms (SNPs) in inflammation-related genes have been linked to an increased risk of ischemic stroke. Most of these SNP results have not been replicated, however, and metaanalyses of the effects of inflammation-related genes are rare. We investigated 49 SNPs in 34 genes previously re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.112151

    authors: Greisenegger S,Zehetmayer S,Bauer P,Endler G,Ferrari J,Lang W,Janisiw M,Steiner L,Cheng S,Lalouschek W,Mannhalter C

    更新日期:2009-01-01 00:00:00

  • Regulation of serum paraoxonase activity by genetic, nutritional, and lifestyle factors in the general population.

    abstract:BACKGROUND:Paraoxonase may protect lipoproteins and cell membranes from peroxidation, and alterations in the activity of this enzyme have been associated with some chronic diseases. Serum paraoxonase appears to be mainly under genetic control, but some studies suggest that environmental factors may also modulate its ac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.9.1491

    authors: Ferré N,Camps J,Fernández-Ballart J,Arija V,Murphy MM,Ceruelo S,Biarnés E,Vilella E,Tous M,Joven J

    更新日期:2003-09-01 00:00:00

  • Clinical evaluation of serial blood processing at point of care.

    abstract::The Axial Separation Module (ASM), which separates whole-blood specimens serially in Axial Process Containers (APC), was evaluated for clinical performance at the University of Virginia Health Sciences Center (UVA HSC) in a community-based outpatient laboratory (North Ridge Clinic). We hypothesized that moving the tas...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Estey CA,Felder RA

    更新日期:1997-02-01 00:00:00

  • Gas-chromatographic measurement of carboxyhemoglobin in blood from mothers and newborns.

    abstract::HbCO in blood sampled from 20 mothers and newborns immediately after birth was measured with a new, simple gas-chromatographic method for CO. The mean ratio of HbCO to total hemoglobin for 13 non-smoking mothers did not differ significantly from that for their infants (mean 0.38%, SD 0.26% vs 0.38%, SD 0.13%), but the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fogh-Andersen N,Eriksen PS,Grinsted J,Siggaard-Andersen O

    更新日期:1988-01-01 00:00:00

  • Detergent extraction and enzymatic analysis for fecal long-chain fatty acids, triglycerides, and cholesterol.

    abstract::We report a procedure for determining fecal long-chain fatty acids (LCFA), triglycerides, and cholesterol after detergent extraction with 10 mL/L Triton X-100, 6 mL/L Brij 30, and 0.1 mol/L HCl in isotonic saline by enzymatic analysis of the extraction supernates. Mean recoveries of calibrators ranged from 105% to 117...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lee MJ,Crook T,Noel C,Levinson UM

    更新日期:1994-12-01 00:00:00

  • Ligand assays: from electrophoresis to miniaturized microarrays.

    abstract::The main developments in the "ligand assay" field in which I have been involved are traced. These include the original development of "first generation" competitive assays relying on radiolabeled analyte markers; the development of the first "second generation", noncompetitive (ultrasensitive) methods, which rely on t...

    journal_title:Clinical chemistry

    pub_type: 历史文章,杂志文章

    doi:

    authors: Ekins RP

    更新日期:1998-09-01 00:00:00

  • The tortuous road to the adoption of katal for the expression of catalytic activity by the General Conference on Weights and Measures.

    abstract:BACKGROUND:The "unit" for "enzymic activity" (U = 1 micromol/min) was recommended by the International Union of Biochemistry and Molecular Biology (IUB) in 1961 and is widely used in medical laboratory reports. The general trend in metrology, however, is toward global standardization through defining units coherent wit...

    journal_title:Clinical chemistry

    pub_type: 历史文章,杂志文章

    doi:

    authors: Dybkaer R

    更新日期:2002-03-01 00:00:00

  • Enzyme-linked immunosorbent assay of retinol-binding protein in serum and urine.

    abstract::This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lucertini S,Valcavi P,Mutti A,Franchini I

    更新日期:1984-01-01 00:00:00

  • Sex and age differences in lipoprotein subclasses measured by nuclear magnetic resonance spectroscopy: the Framingham Study.

    abstract:BACKGROUND:The sex differential in coronary heart disease (CHD) risk, which is not explained by male/female differences in lipid and lipoprotein concentrations, narrows with age. We examined whether this differential CHD risk might, in part, be attributable to the sizes of lipoprotein particles or concentrations of lip...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.032763

    authors: Freedman DS,Otvos JD,Jeyarajah EJ,Shalaurova I,Cupples LA,Parise H,D'Agostino RB,Wilson PW,Schaefer EJ

    更新日期:2004-07-01 00:00:00

  • Genetic variants in the fibroblast growth factor pathway as potential markers of ovarian cancer risk, therapeutic response, and clinical outcome.

    abstract:BACKGROUND:The fibroblast growth factor (FGF) and FGF receptor (FGFR) axis plays a critical role in tumorigenesis, but little is known of its influence in ovarian cancer. We sought to determine the association of genetic variants in the FGF pathway with risk, therapeutic response, and survival of patients with ovarian ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.211490

    authors: Meng QH,Xu E,Hildebrandt MA,Liang D,Lu K,Ye Y,Wagar EA,Wu X

    更新日期:2014-01-01 00:00:00

  • Free erythrocyte porphyrins in the detection of undue absorption of Pb and of Fe deficiency.

    abstract::A fluorometric assay for free erythrocyte porphyrins (FEP) is described in detail, the direct test being used for the analysis of blood specimens collected with anticoagulants and the spot test for analysis of blood specimens collected on filter paper. A method for determining the amount of blood absorbed by different...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Piomelli S

    更新日期:1977-02-01 00:00:00

  • Two-dimensional gel electrophoresis of serum specimens from patients with monoclonal gammopathies.

    abstract::We modified the ISO-DALT two-dimensional gel electrophoresis system to allow the routine examination of serum specimens from patients with monoclonal gammopathies. This system, MC-Iso 1, is characterized by a broad pH gradient for resolving the basic immunoglobulin heavy and light chains. The increased resolution of b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tracy RP,Currie RM,Kyle RA,Young DS

    更新日期:1982-04-01 00:00:00

  • Up-dated catalogue of HeLa cell proteins: percentages and characteristics of the major cell polypeptides labeled with a mixture of 16 14C-labeled amino acids.

    abstract::A total of 1357 polypeptides [946 acidic (isoelectric focusing) and 411 basic (nonequilibrium pH-gradient electrophoresis)] from human HeLa cells have been separated and catalogued with use of high-resolution two-dimensional gel electrophoresis. Of these polypeptides, 1266 were detected by labeling cells with [35S]met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bravo R,Celis JE

    更新日期:1982-04-01 00:00:00