Abstract:
:A "high-performance" liquid-chromatographic procedure for 5-hydroxy-3-indoleacetic acid is described and compared with a colorimetric method in which 1-nitroso-2-naphthol is used. The analyte and an internal standard, p-nitrobenzoic acid, were extracted into diethyl ether from urine at pH 4.0 (acidified with HCl) to which sodium chloride had been added, and the ether was back-extracted with acetate buffer, pH 9.2. Aliquots of this extract were injected into a reversed-phase liquid-chromatographic column and eluted with pH 3.5 acetate buffer/methanol (95/5 by vol); the effluent was monitored at 254 nm. The precision (CV) of the method was 11.8% at 1.8 mg/L, 5.5% at 92 mg/L. Analytical recovery averaged 84%. The colorimetric method gave higher values for the analyte than did the chromatographic method for all patients' urines.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Draganac PS,Steindel SJ,Trawick WGsubject
Has Abstractpub_date
1980-06-01 00:00:00pages
910-2issue
7eissn
0009-9147issn
1530-8561journal_volume
26pub_type
杂志文章abstract:BACKGROUND:We have developed a silicon-based biosensor that generates a visual signal in response to nucleic acid targets. METHODS:In this system, capture oligonucleotide probes are immobilized on the surface of the biosensor. Interaction of the capture probes with a complementary target and a biotinylated detector ol...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-09-01 00:00:00
abstract::This enzyme immunoassay procedure for pregnancy-associated plasma protein type A involves a "sandwich"-type system in microtitration plates. One can detect 0.27 mg of the protein per liter of serum, with a between-batch CV of 10.2%, and the antiserum used does not cross react with any of the other placentally derived ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-11-01 00:00:00
abstract:BACKGROUND:Test repetition could be a readily modifiable component of laboratory utilization. Laboratory test repetition has not been rigorously studied at a population-based level. Our objective was to determine the prevalence of, and charges associated with, repetition of eight common laboratory tests. METHODS:We pe...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.021220
更新日期:2003-12-01 00:00:00
abstract::Ireport a detailed series of microcalorimetric measurement of glucose concentrations in five reference samples of serum. The method utilized (a) calibration in the actual medium of analysis and (b) a correction for interferences owing to the nonspecificity of the enzyme hexokinase. The microcalorimetric results are co...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-10-01 00:00:00
abstract::The optimal measurement method and clinical application of the therapeutic drug monitoring of cyclosporine remain uncertain. At a workshop held at Hawk's Cay, FL, from January 14 to January 17, 1990, 57 scientists presented their latest research findings, either in formal papers or as discussants. Lively debate and di...
journal_title:Clinical chemistry
pub_type: 共识发展会议,杂志文章,评审
doi:
更新日期:1990-08-01 00:00:00
abstract:BACKGROUND:Quantification of integrated proviral HIV DNA by repetitive-sampling Alu-HIV PCR is a candidate virological tool to monitor the HIV reservoir in patients. However, the experimental procedures and data analysis of the assay are complex and hinder its widespread use. Here, we provide an improved and simplified...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.219378
更新日期:2014-06-01 00:00:00
abstract::A simple and convenient method using commercially available derivatization reagents is described for the measurement of betaine and N,N-dimethylglycine (DMG) in blood and urine. Precolumn derivatization of plasma or urine is performed directly in acetonitrile without extraction with p-bromophenacyl bromide and crown e...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-09-01 00:00:00
abstract::We measured the rate of elimination of phenylalanine by constant intravenous infusion of L-phenylalanine in 14 parents of children with phenylketonuria and in 21 subjects with a negative family history for this disease. When reciprocals of the observed elimination rates were plotted against the reciprocals of the incr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-09-01 00:00:00
abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-05-01 00:00:00
abstract:BACKGROUND:Adequate detection of designer steroids in the urine of athletes is still a challenge in doping control analysis and requires knowledge of steroid metabolism. In this study we investigated whether uPA(+/+)-SCID mice carrying functional primary human hepatocytes in their liver would provide a suitable alterna...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.119396
更新日期:2009-10-01 00:00:00
abstract::We describe a sensitive method for the determination of vanadium in biological substances by atomic absorption spectroscopy. By using background correction and pyrolytically coated graphite tubes with flameless apparatus, this vanadium assay has a sensitivity of 65 pg and a detection limit of 30 pg, approximately sixf...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-01-01 00:00:00
abstract::Plasma concentrations of delta-9-tetrahydrocannabinol, the principal psychoactive cannabinoid in marijuana, decline to values substantially less than 1 microgram/L within a few hours after a subject has smoked a marijuana cigarette. Using a single-quadrupole gas chromatograph-mass spectrometer (GC/MS) operated in the ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-12-01 00:00:00
abstract:BACKGROUND:Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS:Blood samples were collected with and withou...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章,多中心研究
doi:
更新日期:2000-06-01 00:00:00
abstract:BACKGROUND:Prostate-specific antigen (PSA) occurs in serum both free and in complex with protease inhibitors. The complex with alpha1-antichymotrypsin (ACT) is the major form in serum, and the proportion of PSA-ACT is higher in prostate cancer (PCa) than in benign prostatic hyperplasia (BPH). PSA also forms a complex w...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-06-01 00:00:00
abstract::We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuri...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-10-01 00:00:00
abstract::We report here the evaluation of the Abbott TDx assay with a monoclonal antibody for selectively quantifying cyclosporine (CsA) in whole blood. Over the clinically relevant concentration ranges, results with this assay demonstrated within- and between-run CVs of less than 2.5% and 5%, respectively; sensitivity of 25 m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-11-01 00:00:00
abstract::With the ultramicroanalytical system described here we can measure glucose in 1 microL of plasma or serum. The sample is placed on a dry, multilayer film element (Eastman Kodak), where a colored spot about 3.5 mm in diameter develops. The reflectance of these spots is measured with a reflectance digital matrix photome...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-12-01 00:00:00
abstract:BACKGROUND:Single-nucleotide polymorphisms (SNPs) in inflammation-related genes have been linked to an increased risk of ischemic stroke. Most of these SNP results have not been replicated, however, and metaanalyses of the effects of inflammation-related genes are rare. We investigated 49 SNPs in 34 genes previously re...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.112151
更新日期:2009-01-01 00:00:00
abstract:BACKGROUND:Paraoxonase may protect lipoproteins and cell membranes from peroxidation, and alterations in the activity of this enzyme have been associated with some chronic diseases. Serum paraoxonase appears to be mainly under genetic control, but some studies suggest that environmental factors may also modulate its ac...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.9.1491
更新日期:2003-09-01 00:00:00
abstract::The Axial Separation Module (ASM), which separates whole-blood specimens serially in Axial Process Containers (APC), was evaluated for clinical performance at the University of Virginia Health Sciences Center (UVA HSC) in a community-based outpatient laboratory (North Ridge Clinic). We hypothesized that moving the tas...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-02-01 00:00:00
abstract::HbCO in blood sampled from 20 mothers and newborns immediately after birth was measured with a new, simple gas-chromatographic method for CO. The mean ratio of HbCO to total hemoglobin for 13 non-smoking mothers did not differ significantly from that for their infants (mean 0.38%, SD 0.26% vs 0.38%, SD 0.13%), but the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-01-01 00:00:00
abstract::We report a procedure for determining fecal long-chain fatty acids (LCFA), triglycerides, and cholesterol after detergent extraction with 10 mL/L Triton X-100, 6 mL/L Brij 30, and 0.1 mol/L HCl in isotonic saline by enzymatic analysis of the extraction supernates. Mean recoveries of calibrators ranged from 105% to 117...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-12-01 00:00:00
abstract::The main developments in the "ligand assay" field in which I have been involved are traced. These include the original development of "first generation" competitive assays relying on radiolabeled analyte markers; the development of the first "second generation", noncompetitive (ultrasensitive) methods, which rely on t...
journal_title:Clinical chemistry
pub_type: 历史文章,杂志文章
doi:
更新日期:1998-09-01 00:00:00
abstract:BACKGROUND:The "unit" for "enzymic activity" (U = 1 micromol/min) was recommended by the International Union of Biochemistry and Molecular Biology (IUB) in 1961 and is widely used in medical laboratory reports. The general trend in metrology, however, is toward global standardization through defining units coherent wit...
journal_title:Clinical chemistry
pub_type: 历史文章,杂志文章
doi:
更新日期:2002-03-01 00:00:00
abstract::This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 de...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-01-01 00:00:00
abstract:BACKGROUND:The sex differential in coronary heart disease (CHD) risk, which is not explained by male/female differences in lipid and lipoprotein concentrations, narrows with age. We examined whether this differential CHD risk might, in part, be attributable to the sizes of lipoprotein particles or concentrations of lip...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.032763
更新日期:2004-07-01 00:00:00
abstract:BACKGROUND:The fibroblast growth factor (FGF) and FGF receptor (FGFR) axis plays a critical role in tumorigenesis, but little is known of its influence in ovarian cancer. We sought to determine the association of genetic variants in the FGF pathway with risk, therapeutic response, and survival of patients with ovarian ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.211490
更新日期:2014-01-01 00:00:00
abstract::A fluorometric assay for free erythrocyte porphyrins (FEP) is described in detail, the direct test being used for the analysis of blood specimens collected with anticoagulants and the spot test for analysis of blood specimens collected on filter paper. A method for determining the amount of blood absorbed by different...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-02-01 00:00:00
abstract::We modified the ISO-DALT two-dimensional gel electrophoresis system to allow the routine examination of serum specimens from patients with monoclonal gammopathies. This system, MC-Iso 1, is characterized by a broad pH gradient for resolving the basic immunoglobulin heavy and light chains. The increased resolution of b...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-04-01 00:00:00
abstract::A total of 1357 polypeptides [946 acidic (isoelectric focusing) and 411 basic (nonequilibrium pH-gradient electrophoresis)] from human HeLa cells have been separated and catalogued with use of high-resolution two-dimensional gel electrophoresis. Of these polypeptides, 1266 were detected by labeling cells with [35S]met...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-04-01 00:00:00