Dairy Intake and Body Composition and Cardiometabolic Traits among Adults: Mendelian Randomization Analysis of 182041 Individuals from 18 Studies.

Abstract:

BACKGROUND:Associations between dairy intake and body composition and cardiometabolic traits have been inconsistently observed in epidemiological studies, and the causal relationship remains ill-defined. METHODS:We performed Mendelian randomization analysis using an established genetic variant located upstream of the lactase gene (LCT-13910 C/T, rs4988235) associated with dairy intake as an instrumental variable (IV). The causal effects of dairy intake on body composition and cardiometabolic traits (lipids, glycemic traits, and inflammatory factors) were quantified by IV estimators among 182041 participants from 18 studies. RESULTS:Each 1 serving/day higher dairy intake was associated with higher lean mass [β (SE) = 0.117 kg (0.035); P = 0.001], higher hemoglobin A1c [0.009% (0.002); P < 0.001], lower LDL [-0.014 mmol/L (0.006); P = 0.013], total cholesterol (TC) [-0.012 mmol/L (0.005); P = 0.023], and non-HDL [-0.012 mmol/L (0.005); P = 0.028]. The LCT-13910 C/T CT + TT genotype was associated with 0.214 more dairy servings/day (SE = 0.047; P < 0.001), 0.284 cm higher waist circumference (SE = 0.118; P = 0.017), 0.112 kg higher lean mass (SE = 0.027; P = 3.8 × 10-5), 0.032 mmol/L lower LDL (SE = 0.009; P = 0.001), and 0.032 mmol/L lower TC (SE = 0.010; P = 0.001). Genetically higher dairy intake was associated with increased lean mass [0.523 kg per serving/day (0.170); P = 0.002] after correction for multiple testing (0.05/18). However, we find that genetically higher dairy intake was not associated with lipids and glycemic traits. CONCLUSIONS:The present study provides evidence to support a potential causal effect of higher dairy intake on increased lean mass among adults. Our findings suggest that the observational associations of dairy intake with lipids and glycemic traits may be the result of confounding.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Mendelian Randomization of Dairy Consumption Working Group.,CHARGE consortium.

doi

10.1373/clinchem.2018.300335

subject

Has Abstract

pub_date

2019-06-01 00:00:00

pages

751-760

issue

6

eissn

0009-9147

issn

1530-8561

pii

clinchem.2018.300335

journal_volume

65

pub_type

杂志文章
  • Direct determination of plasma endothelin-I by chemiluminescence enzyme immunoassay.

    abstract::A highly sensitive sandwich-type chemiluminescence enzyme immunoassay for plasma endothelin-I (ET-1), involving no extraction steps, has been developed. Two populations of polyclonal antibodies were used in the present study: One is specific to the C-terminus of the endothelin family of peptides; the other, a Fab' fra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iwata R,Hayashi T,Nakao Y,Yamaki M,Yoshimasa T,Ito H,Saito Y,Mukoyam M,Nakao K

    更新日期:1996-08-01 00:00:00

  • Total serum cholesterol by isotope dilution/mass spectrometry: a candidate definitive method.

    abstract::We describe a highly accurate and precise method for determination of total cholesterol in serum by isotope dilution/mass spectrometry. The method was developed for a Study Group of the Committee on Standards of the American Association for Clinical Chemistry, for use in establishing the accuracy of a candidate refere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cohen A,Hertz HS,Mandel J,Paule RC,Schaffer R,Sniegoski LT,Sun T,Welch MJ,White E 5th

    更新日期:1980-06-01 00:00:00

  • Fluorometric procedure for determining "lamellar body" phospholipids in the particulate fraction of amniotic fluid after filtration.

    abstract::A rapid (30-min) semiautomated continuous-flow procedure is described for use in assessing the phospholipids of the particulate ("lamellar body") fraction of human amniotic fluid. The method is based on measuring the difference in fluorescence of 1,6,-diphenyl-1,3,5-hexatriene added to amniotic fluid before and after ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Egberts J,Soederhuizen W,Gebhardt DO

    更新日期:1983-02-01 00:00:00

  • Laboratory methods and quality assurance in the Cardiovascular Health Study.

    abstract::The Cardiovascular Health Study is an observational cohort study of risk factors for cardiovascular disease in 5201 participants, ages > or = 65 years. We report the methods and quality-assurance results for blood procurement, processing, shipping, storage, and sample analysis used during the first examination period ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cushman M,Cornell ES,Howard PR,Bovill EG,Tracy RP

    更新日期:1995-02-01 00:00:00

  • Factor V Leiden and other coagulation factor mutations affecting thrombotic risk.

    abstract::Five genetic defects have been established as risk factors for venous thrombosis. Three are protein C, protein S, and antithrombin deficiencies, defects in the anticoagulant pathways of blood coagulation. Together they can be found in approximately 15% of families with inherited thrombophilia. Their laboratory diagnos...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Bertina RM

    更新日期:1997-09-01 00:00:00

  • Is determination of creatine kinase-2 after electrophoretic separation accurate?

    abstract::Since 1991, the Ontario Laboratory Proficiency Testing Program has assessed the analytical performance of creatine kinase (CK; EC 2.7.3.2) isoenzyme-2, using fresh human serum supplemented with purified human CK isoenzymes. In Ontario, the 142 laboratories licensed to analyze CK-2 use a variety of methods: electrophor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Henderson AR,Stark JA,McQueen MJ,Patten RL,Krishnan S,Wood DE,Webb S

    更新日期:1994-02-01 00:00:00

  • Differential patterns of bone turnover in relation to bone pain and disease extent in bone in cancer patients with skeletal metastases.

    abstract:BACKGROUND:The alteration of the bone microenvironment as a consequence of skeletal metastases is poorly understood. The aim of this study was to search for patterns of bone markers in relation to primary tumor type, bone pain, and number of sites involved in patients with bone metastases. METHODS:We studied 323 patie...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Berruti A,Dogliotti L,Gorzegno G,Torta M,Tampellini M,Tucci M,Cerutti S,Frezet MM,Stivanello M,Sacchetto G,Angeli A

    更新日期:1999-08-01 00:00:00

  • Radioimmunoassay of creatine kinase isoenzymes in human serum: isoenzyme MM.

    abstract::Measurement of the mass concentration of serum enzymes by radioimmunoassay provides direct quantitation of specific isoenzymes and may be less subject to some of the limitations of traditional assay procedures for enzymes. We describe the development of a sensitive and specific radioimmunoassay for the muscle isoenzym...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Steirteghem AC,Zweig MH,Schechter AN

    更新日期:1978-03-01 00:00:00

  • More sensitive flameless atomic absorption analysis of vanadium in tissue and serum.

    abstract::We describe a sensitive method for the determination of vanadium in biological substances by atomic absorption spectroscopy. By using background correction and pyrolytically coated graphite tubes with flameless apparatus, this vanadium assay has a sensitivity of 65 pg and a detection limit of 30 pg, approximately sixf...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stroop SD,Helinek G,Greene HL

    更新日期:1982-01-01 00:00:00

  • Characterization of a new certified reference material for human cardiac troponin I.

    abstract:BACKGROUND:To address the continuing need for the standardization of clinical human cardiac troponin I (cTnI) assays, NIST, with the assistance of the AACC/IFCC Cardiac Troponin I Standardization Committee, has developed a new certified reference material, Standard Reference Material (SRM) 2921: Human Cardiac Troponin ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051359

    authors: Bunk DM,Welch MJ

    更新日期:2006-02-01 00:00:00

  • Detecting CFTR gene mutations by using primer oligo base extension and mass spectrometry.

    abstract::A new method for the reliable identification of localized variations in DNA by detection of associated diagnostic products with matrix-assisted laser desorption ionization time-of-flight mass spectrometry is described. The diagnostic products are generated by the primer oligo base extension (PROBE) reaction, which req...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Braun A,Little DP,Köster H

    更新日期:1997-07-01 00:00:00

  • Proteomic Discovery and Validation of the Confounding Effect of Heparin Administration on the Analysis of Candidate Cardiovascular Biomarkers.

    abstract:BACKGROUND:Several plasma proteins have been suggested as markers for a variety of cardiovascular conditions but fail to qualify in independent patient cohorts. This may relate to interference of medication on plasma protein concentrations. We used proteomics to identify plasma proteins that changed in concentration wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.282665

    authors: Beck HC,Jensen LO,Gils C,Ilondo AMM,Frydland M,Hassager C,Møller-Helgestad OK,Møller JE,Rasmussen LM

    更新日期:2018-10-01 00:00:00

  • Dried plasma spot measurements of ferritin and transferrin receptor for assessing iron status.

    abstract:BACKGROUND:Efforts to reduce the high global prevalence of nutritional anemia require the use of both reliable laboratory assays to distinguish iron deficiency from other causes of anemia and cost-effective methods for collection of blood specimens under field conditions. The suitability of using small plasma samples s...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Flowers CH,Cook JD

    更新日期:1999-10-01 00:00:00

  • Evaluation of pteroylglutamic acid and n-5-methyltetrahydrofolic acid reference standards in a new "No-Boil" radioassay for serum folate.

    abstract::Serum folate, pteroylglutamic acid standards, and N-5-methyltetrahydrofolate standards extract differently during sample preparation for radiometric assay. B/B0 values for each material were determined before and after an alkaline extraction procedure. Serum folate most closely resembled N-5-methyltetrahydrofolate sta...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Theobald RA,Batchelder M,Sturgeon MF

    更新日期:1981-04-01 00:00:00

  • The tortuous road to the adoption of katal for the expression of catalytic activity by the General Conference on Weights and Measures.

    abstract:BACKGROUND:The "unit" for "enzymic activity" (U = 1 micromol/min) was recommended by the International Union of Biochemistry and Molecular Biology (IUB) in 1961 and is widely used in medical laboratory reports. The general trend in metrology, however, is toward global standardization through defining units coherent wit...

    journal_title:Clinical chemistry

    pub_type: 历史文章,杂志文章

    doi:

    authors: Dybkaer R

    更新日期:2002-03-01 00:00:00

  • Increased plasma concentrations of activin a predict intraventricular hemorrhage in preterm newborns.

    abstract:BACKGROUND:Intraventricular hemorrhage (IVH) is a major cause of neurologic disabilities in preterm newborns. We evaluated the use of plasma activin A concentrations to predict the development of perinatal IVH. METHODS:We measured nucleated erythrocyte (NRBC) counts, plasma activin A, hypoxanthine (Hyp), and xanthine ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065979

    authors: Florio P,Perrone S,Luisi S,Vezzosi P,Longini M,Marzocchi B,Petraglia F,Buonocore G

    更新日期:2006-08-01 00:00:00

  • Selection, preparation, and characterization of commutable frozen human serum pools as potential secondary reference materials for lipid and apolipoprotein measurements: study within the framework of the Dutch project "Calibration 2000".

    abstract:BACKGROUND:The Dutch project "Calibration 2000" aims at harmonization of laboratory results via calibration by development of matrix-based secondary reference materials. We considered the selection, preparation, and characterization of 34 potential reference materials (PRMs). METHODS:Sixteen PRMs were prepared either ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:

    authors: Cobbaert C,Weykamp C,Baadenhuijsen H,Kuypers A,Lindemans J,Jansen R

    更新日期:2002-09-01 00:00:00

  • Results compared for tricyclic antidepressants as assayed by liquid chromatography and enzyme immunoassay.

    abstract::The tricyclic antidepressants amitriptyline, nortriptyline, imipramine, and desipramine in serum of patients taking one of the drugs were quantified in two laboratories by high-performance liquid chromatography (HPLC) and enzyme-multiplied immunoassay (EMIT; Syva). Results for split samples were highly correlated, but...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dorey RC,Preskorn SH,Widener PK

    更新日期:1988-11-01 00:00:00

  • Analysis for indole compounds in urine by high-performance liquid chromatography with fluorometric detection.

    abstract::We describe a chromatographic system involving a high-performance chemically-bonded reverse-phase column and fluorescence detection for measurement of indoles in urine. We controlled retention and selectivity by optimizing the methanol content and pH of the mobile phase. Six reference indoles were separated in less th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Graffeo AP,Karger BL

    更新日期:1976-02-01 00:00:00

  • Automated creatine kinase-MB estimation by immuno-inhibition: a clinical evaluation.

    abstract::We detected the presence of creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in serum by using an immunoinhibition technique to inactivate the creatine kinase isoenzyme of muscle origin (CK-MM). The GEMSAEC centrifugal analyzer is ideally suited for this procedure because it rapidly mixes reagents and has a throughpu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delahunty TJ,Foreback CC

    更新日期:1980-04-01 00:00:00

  • Seven different assays of hyaluronan compared for clinical utility.

    abstract::To compare six assays of hyaluronan (hyaluronic acid; HYA) in serum, developed in different laboratories, we analyzed 10 samples from each of three groups: healthy persons, patients with primary biliary cirrhosis, and patients with rheumatoid arthritis. All the assays are based on the use of affinity proteins specific...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lindqvist U,Chichibu K,Delpech B,Goldberg RL,Knudson W,Poole AR,Laurent TC

    更新日期:1992-01-01 00:00:00

  • Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement.

    abstract:BACKGROUND:Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.118000

    authors: Campbell DJ,Nussberger J,Stowasser M,Danser AH,Morganti A,Frandsen E,Ménard J

    更新日期:2009-05-01 00:00:00

  • Biochemical and genetic markers of iron status and the risk of coronary artery disease: an angiography-based study.

    abstract:BACKGROUND:Iron may promote coronary atherosclerotic disease (CAD) by increasing lipid peroxidation. Studies on biochemical or genetic markers of body iron stores as risk factors for CAD have yielded conflicting results. METHODS:We studied 849 individuals with a clear-cut definition of the CAD phenotype, i.e., with (C...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bozzini C,Girelli D,Tinazzi E,Olivieri O,Stranieri C,Bassi A,Trabetti E,Faccini G,Pignatti PF,Corrocher R

    更新日期:2002-01-01 00:00:00

  • Use of a synthetic soluble bilirubin derivative to assess interference in creatinine measurements.

    abstract::In assessing interference from bilirubin, the use of a synthetic soluble derivative (ditaurobilirubin, DTB) is recommended as a surrogate for the natural conjugates (Bc). We compared the interference effect of unconjugated bilirubin (Bu), Bc, and DTB, using six mechanized methods for serum creatinine measurement. No s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Franzini C,Morelli AM,Cattozzo G

    更新日期:1991-02-01 00:00:00

  • Advanced glycosylation end products in the mesenteric artery.

    abstract::We measured advanced glycosylation end products in the mesenteric artery of 37 patients (ages 29-82 years), 34 of whom were nondiabetic. Samples of arterial tissue were obtained during bowel resectioning. Advanced glycosylation end products were measured as collagen-linked fluorescence (excitation wavelength 370 nm, e...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: MacDonald E,Lee WK,Hepburn S,Bell J,Scott PJ,Dominiczak MH

    更新日期:1992-04-01 00:00:00

  • Immobilization of antibodies on ultraflat polystyrene surfaces.

    abstract:BACKGROUND:Functional antibody surfaces were prepared on ultraflat polystyrene surfaces by physical adsorption, and the uniform distribution of monoclonal antibodies against hepatitis B surface antigen (anti-HBs) on such surfaces and the presence of dense hepatitis B surface antigen (HBsAg) particles captured by immobi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Qian W,Yao D,Yu F,Xu B,Zhou R,Bao X,Lu Z

    更新日期:2000-09-01 00:00:00

  • Detection and characterization of blocking-type anti-acetylcholine receptor antibodies in sera from patients with myasthenia gravis.

    abstract::We developed a highly sensitive, convenient assay for measuring blocking-type anti-acetylcholine receptor antibodies, which inhibit the binding of 125I-labeled alpha-bungarotoxin (alpha-BuTx) to the acetylcholine receptor (AChR). This procedure detected inhibitory activities in sera from 76% of patients with myastheni...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hara H,Hayashi K,Ohta K,Itoh N,Nishitani H,Ohta M

    更新日期:1993-10-01 00:00:00

  • Variability of plasma lipids and lipoproteins: the Jerusalem Lipid Research Clinic Study.

    abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friedlander Y,Kark JD,Stein Y

    更新日期:1985-07-01 00:00:00

  • Measurement of the complex between prostate-specific antigen and alpha1-protease inhibitor in serum.

    abstract:BACKGROUND:Prostate-specific antigen (PSA) occurs in serum both free and in complex with protease inhibitors. The complex with alpha1-antichymotrypsin (ACT) is the major form in serum, and the proportion of PSA-ACT is higher in prostate cancer (PCa) than in benign prostatic hyperplasia (BPH). PSA also forms a complex w...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Zhang WM,Finne P,Leinonen J,Vesalainen S,Nordling S,Stenman UH

    更新日期:1999-06-01 00:00:00

  • Multiplex tetra-primer amplification refractory mutation system PCR to detect 6 common germline mutations of the MUTYH gene associated with polyposis and colorectal cancer.

    abstract:BACKGROUND:We describe a simple tetra-primer amplification refractory mutation system PCR (T-ARMS-PCR) for detecting MUTYH mutations, which are associated with colorectal adenomas and colorectal cancer. METHODS:We designed specific T-ARMS-PCR assays for 6 mutations (Y165C, G382D, 1395_7delGGA, Y90X, 1103delC, and R231...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.060137

    authors: Piccioli P,Serra M,Gismondi V,Pedemonte S,Loiacono F,Lastraioli S,Bertario L,De Angioletti M,Varesco L,Notaro R

    更新日期:2006-04-01 00:00:00