Abstract:
BACKGROUND:Associations between dairy intake and body composition and cardiometabolic traits have been inconsistently observed in epidemiological studies, and the causal relationship remains ill-defined. METHODS:We performed Mendelian randomization analysis using an established genetic variant located upstream of the lactase gene (LCT-13910 C/T, rs4988235) associated with dairy intake as an instrumental variable (IV). The causal effects of dairy intake on body composition and cardiometabolic traits (lipids, glycemic traits, and inflammatory factors) were quantified by IV estimators among 182041 participants from 18 studies. RESULTS:Each 1 serving/day higher dairy intake was associated with higher lean mass [β (SE) = 0.117 kg (0.035); P = 0.001], higher hemoglobin A1c [0.009% (0.002); P < 0.001], lower LDL [-0.014 mmol/L (0.006); P = 0.013], total cholesterol (TC) [-0.012 mmol/L (0.005); P = 0.023], and non-HDL [-0.012 mmol/L (0.005); P = 0.028]. The LCT-13910 C/T CT + TT genotype was associated with 0.214 more dairy servings/day (SE = 0.047; P < 0.001), 0.284 cm higher waist circumference (SE = 0.118; P = 0.017), 0.112 kg higher lean mass (SE = 0.027; P = 3.8 × 10-5), 0.032 mmol/L lower LDL (SE = 0.009; P = 0.001), and 0.032 mmol/L lower TC (SE = 0.010; P = 0.001). Genetically higher dairy intake was associated with increased lean mass [0.523 kg per serving/day (0.170); P = 0.002] after correction for multiple testing (0.05/18). However, we find that genetically higher dairy intake was not associated with lipids and glycemic traits. CONCLUSIONS:The present study provides evidence to support a potential causal effect of higher dairy intake on increased lean mass among adults. Our findings suggest that the observational associations of dairy intake with lipids and glycemic traits may be the result of confounding.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Mendelian Randomization of Dairy Consumption Working Group.,CHARGE consortium.doi
10.1373/clinchem.2018.300335subject
Has Abstractpub_date
2019-06-01 00:00:00pages
751-760issue
6eissn
0009-9147issn
1530-8561pii
clinchem.2018.300335journal_volume
65pub_type
杂志文章abstract::A highly sensitive sandwich-type chemiluminescence enzyme immunoassay for plasma endothelin-I (ET-1), involving no extraction steps, has been developed. Two populations of polyclonal antibodies were used in the present study: One is specific to the C-terminus of the endothelin family of peptides; the other, a Fab' fra...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-08-01 00:00:00
abstract::We describe a highly accurate and precise method for determination of total cholesterol in serum by isotope dilution/mass spectrometry. The method was developed for a Study Group of the Committee on Standards of the American Association for Clinical Chemistry, for use in establishing the accuracy of a candidate refere...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-06-01 00:00:00
abstract::A rapid (30-min) semiautomated continuous-flow procedure is described for use in assessing the phospholipids of the particulate ("lamellar body") fraction of human amniotic fluid. The method is based on measuring the difference in fluorescence of 1,6,-diphenyl-1,3,5-hexatriene added to amniotic fluid before and after ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-02-01 00:00:00
abstract::The Cardiovascular Health Study is an observational cohort study of risk factors for cardiovascular disease in 5201 participants, ages > or = 65 years. We report the methods and quality-assurance results for blood procurement, processing, shipping, storage, and sample analysis used during the first examination period ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-02-01 00:00:00
abstract::Five genetic defects have been established as risk factors for venous thrombosis. Three are protein C, protein S, and antithrombin deficiencies, defects in the anticoagulant pathways of blood coagulation. Together they can be found in approximately 15% of families with inherited thrombophilia. Their laboratory diagnos...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1997-09-01 00:00:00
abstract::Since 1991, the Ontario Laboratory Proficiency Testing Program has assessed the analytical performance of creatine kinase (CK; EC 2.7.3.2) isoenzyme-2, using fresh human serum supplemented with purified human CK isoenzymes. In Ontario, the 142 laboratories licensed to analyze CK-2 use a variety of methods: electrophor...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-02-01 00:00:00
abstract:BACKGROUND:The alteration of the bone microenvironment as a consequence of skeletal metastases is poorly understood. The aim of this study was to search for patterns of bone markers in relation to primary tumor type, bone pain, and number of sites involved in patients with bone metastases. METHODS:We studied 323 patie...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-08-01 00:00:00
abstract::Measurement of the mass concentration of serum enzymes by radioimmunoassay provides direct quantitation of specific isoenzymes and may be less subject to some of the limitations of traditional assay procedures for enzymes. We describe the development of a sensitive and specific radioimmunoassay for the muscle isoenzym...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-03-01 00:00:00
abstract::We describe a sensitive method for the determination of vanadium in biological substances by atomic absorption spectroscopy. By using background correction and pyrolytically coated graphite tubes with flameless apparatus, this vanadium assay has a sensitivity of 65 pg and a detection limit of 30 pg, approximately sixf...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-01-01 00:00:00
abstract:BACKGROUND:To address the continuing need for the standardization of clinical human cardiac troponin I (cTnI) assays, NIST, with the assistance of the AACC/IFCC Cardiac Troponin I Standardization Committee, has developed a new certified reference material, Standard Reference Material (SRM) 2921: Human Cardiac Troponin ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.051359
更新日期:2006-02-01 00:00:00
abstract::A new method for the reliable identification of localized variations in DNA by detection of associated diagnostic products with matrix-assisted laser desorption ionization time-of-flight mass spectrometry is described. The diagnostic products are generated by the primer oligo base extension (PROBE) reaction, which req...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-07-01 00:00:00
abstract:BACKGROUND:Several plasma proteins have been suggested as markers for a variety of cardiovascular conditions but fail to qualify in independent patient cohorts. This may relate to interference of medication on plasma protein concentrations. We used proteomics to identify plasma proteins that changed in concentration wi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2017.282665
更新日期:2018-10-01 00:00:00
abstract:BACKGROUND:Efforts to reduce the high global prevalence of nutritional anemia require the use of both reliable laboratory assays to distinguish iron deficiency from other causes of anemia and cost-effective methods for collection of blood specimens under field conditions. The suitability of using small plasma samples s...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-10-01 00:00:00
abstract::Serum folate, pteroylglutamic acid standards, and N-5-methyltetrahydrofolate standards extract differently during sample preparation for radiometric assay. B/B0 values for each material were determined before and after an alkaline extraction procedure. Serum folate most closely resembled N-5-methyltetrahydrofolate sta...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-04-01 00:00:00
abstract:BACKGROUND:The "unit" for "enzymic activity" (U = 1 micromol/min) was recommended by the International Union of Biochemistry and Molecular Biology (IUB) in 1961 and is widely used in medical laboratory reports. The general trend in metrology, however, is toward global standardization through defining units coherent wit...
journal_title:Clinical chemistry
pub_type: 历史文章,杂志文章
doi:
更新日期:2002-03-01 00:00:00
abstract:BACKGROUND:Intraventricular hemorrhage (IVH) is a major cause of neurologic disabilities in preterm newborns. We evaluated the use of plasma activin A concentrations to predict the development of perinatal IVH. METHODS:We measured nucleated erythrocyte (NRBC) counts, plasma activin A, hypoxanthine (Hyp), and xanthine ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.065979
更新日期:2006-08-01 00:00:00
abstract:BACKGROUND:The Dutch project "Calibration 2000" aims at harmonization of laboratory results via calibration by development of matrix-based secondary reference materials. We considered the selection, preparation, and characterization of 34 potential reference materials (PRMs). METHODS:Sixteen PRMs were prepared either ...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:
更新日期:2002-09-01 00:00:00
abstract::The tricyclic antidepressants amitriptyline, nortriptyline, imipramine, and desipramine in serum of patients taking one of the drugs were quantified in two laboratories by high-performance liquid chromatography (HPLC) and enzyme-multiplied immunoassay (EMIT; Syva). Results for split samples were highly correlated, but...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-11-01 00:00:00
abstract::We describe a chromatographic system involving a high-performance chemically-bonded reverse-phase column and fluorescence detection for measurement of indoles in urine. We controlled retention and selectivity by optimizing the methanol content and pH of the mobile phase. Six reference indoles were separated in less th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-02-01 00:00:00
abstract::We detected the presence of creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in serum by using an immunoinhibition technique to inactivate the creatine kinase isoenzyme of muscle origin (CK-MM). The GEMSAEC centrifugal analyzer is ideally suited for this procedure because it rapidly mixes reagents and has a throughpu...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-04-01 00:00:00
abstract::To compare six assays of hyaluronan (hyaluronic acid; HYA) in serum, developed in different laboratories, we analyzed 10 samples from each of three groups: healthy persons, patients with primary biliary cirrhosis, and patients with rheumatoid arthritis. All the assays are based on the use of affinity proteins specific...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-01-01 00:00:00
abstract:BACKGROUND:Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in i...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2008.118000
更新日期:2009-05-01 00:00:00
abstract:BACKGROUND:Iron may promote coronary atherosclerotic disease (CAD) by increasing lipid peroxidation. Studies on biochemical or genetic markers of body iron stores as risk factors for CAD have yielded conflicting results. METHODS:We studied 849 individuals with a clear-cut definition of the CAD phenotype, i.e., with (C...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2002-01-01 00:00:00
abstract::In assessing interference from bilirubin, the use of a synthetic soluble derivative (ditaurobilirubin, DTB) is recommended as a surrogate for the natural conjugates (Bc). We compared the interference effect of unconjugated bilirubin (Bu), Bc, and DTB, using six mechanized methods for serum creatinine measurement. No s...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-02-01 00:00:00
abstract::We measured advanced glycosylation end products in the mesenteric artery of 37 patients (ages 29-82 years), 34 of whom were nondiabetic. Samples of arterial tissue were obtained during bowel resectioning. Advanced glycosylation end products were measured as collagen-linked fluorescence (excitation wavelength 370 nm, e...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-04-01 00:00:00
abstract:BACKGROUND:Functional antibody surfaces were prepared on ultraflat polystyrene surfaces by physical adsorption, and the uniform distribution of monoclonal antibodies against hepatitis B surface antigen (anti-HBs) on such surfaces and the presence of dense hepatitis B surface antigen (HBsAg) particles captured by immobi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-09-01 00:00:00
abstract::We developed a highly sensitive, convenient assay for measuring blocking-type anti-acetylcholine receptor antibodies, which inhibit the binding of 125I-labeled alpha-bungarotoxin (alpha-BuTx) to the acetylcholine receptor (AChR). This procedure detected inhibitory activities in sera from 76% of patients with myastheni...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-10-01 00:00:00
abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-07-01 00:00:00
abstract:BACKGROUND:Prostate-specific antigen (PSA) occurs in serum both free and in complex with protease inhibitors. The complex with alpha1-antichymotrypsin (ACT) is the major form in serum, and the proportion of PSA-ACT is higher in prostate cancer (PCa) than in benign prostatic hyperplasia (BPH). PSA also forms a complex w...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-06-01 00:00:00
abstract:BACKGROUND:We describe a simple tetra-primer amplification refractory mutation system PCR (T-ARMS-PCR) for detecting MUTYH mutations, which are associated with colorectal adenomas and colorectal cancer. METHODS:We designed specific T-ARMS-PCR assays for 6 mutations (Y165C, G382D, 1395_7delGGA, Y90X, 1103delC, and R231...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.060137
更新日期:2006-04-01 00:00:00