Enzyme immunoassay of thyroxin-binding globulin.

Abstract:

:We describe a new double-antibody enzyme radioimmunoassay for thyroxin-binding globulin (TBG) in serum. A TBG-beta-D-galactosidase complex was prepared with m-maleimidobenzoyl N-hydroxysuccinimide ester. The mean analytical recovery of TBG added to serum was 99%, sample volume and TBG value were linearly related, and values for TBG determined by this method and those determined by radioimmunoassay correlated well (r = 0.98). Coefficients of variation averaged 7.6% within assay, 6.6% between assay. The measurable range of TBG in the serum was 3.3 to 52 mg/L, but higher TBG concentrations could be measured by diluting the test serum with TBG-free serum. Mean (and SD) serum TBG concentrations as determined by this method were as follows: for 20 normal subjects, 21.2 (3.7) mg/L; for 10 pregnant women, 50.1 (9.5 mg/L; and for 10 patients with TBG deficiency, not detectable.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Miyai K,Ito M,Hata N

subject

Has Abstract

pub_date

1982-12-01 00:00:00

pages

2408-11

issue

12

eissn

0009-9147

issn

1530-8561

journal_volume

28

pub_type

杂志文章
  • Non-enzymic glycation of individual plasma proteins in normoglycemic and hyperglycemic patients.

    abstract::Diabetic patients in poor glycemic control show increased glycation of total plasma proteins, but little is yet known about the relative extents to which the various individual proteins are glycated. Thus, we studied the non-enzymic glycation of several major plasma proteins and plasma protein fractions in normal and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Austin GE,Mullins RH,Morin LG

    更新日期:1987-12-01 00:00:00

  • Two-dimensional gel electrophoresis of serum specimens from patients with monoclonal gammopathies.

    abstract::We modified the ISO-DALT two-dimensional gel electrophoresis system to allow the routine examination of serum specimens from patients with monoclonal gammopathies. This system, MC-Iso 1, is characterized by a broad pH gradient for resolving the basic immunoglobulin heavy and light chains. The increased resolution of b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tracy RP,Currie RM,Kyle RA,Young DS

    更新日期:1982-04-01 00:00:00

  • Gas-liquid chromatographic determination of bupivacaine and lidocaine in plasma.

    abstract::A modified gas-liquid chromatographic method for determining plasma concentrations of bupivacaine and lidocaine is described, with cyclizine as an internal standard. The extraction procedure requires no solvent evaporation, thus overcoming the problem of drug volatility. Concentrations as low as 0.1 mg/liter can be de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Zylber-Katz E,Granit L,Levy M

    更新日期:1978-09-01 00:00:00

  • Improved estimation of fructosamine, as a measure of glycated serum protein, with the Technicon RA-1000 analyzer.

    abstract::We present an improved fructosamine assay for use with the Technicon RA-1000 analyzer. Features of this assay include: specimen throughput of 100 per hour, within-batch CV of 1.5%, between-batch CV of 2.4%, standard curve linear up to 24.9 mmol of fructosamine per liter, and good correlation (r = 0.82) with hemoglobin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: San-Gil F,Schier GM,Moses RG,Gan IE

    更新日期:1985-12-01 00:00:00

  • 3H and 125I radioimmunoassays of haloperidol compared with fluoroimmunoassay involving antibody coupled to magnetizable solid phase.

    abstract::Radioimmunoassays for haloperidol are described, involving use of tritium- or 125I-labeled drug or tritium-labeled spiroperidol, and a rabbit antiserum to a drug/bovine serum albumin conjugate. The 125I-labeled drug was prepared by the Chloramine T iodination technique. A fluoroimmunoassay for haloperidol is also desc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rowell FJ,Hui SM,Kamel SR

    更新日期:1981-07-01 00:00:00

  • Single-reagent polarization fluoroimmunoassay for barbiturates in urine.

    abstract::We describe a rapid polarization fluoroimmunoassay for screening for the presence of barbiturates in urine. The single reagent is prepared by pre-mixing antiserum with a fluorescein-labeled barbiturate derivative as tracer. Use of a mixture of two sheep antisera, raised against different barbiturate immunogens, result...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colbert DL,Smith DS,Landon J,Sidki AM

    更新日期:1984-11-01 00:00:00

  • High-purity 4-nitrophenol: purification, characterization, and specifications for use as a spectrophotometric reference material.

    abstract::We describe specifications for high-purity 4-nitrophenol, which is suitable for spectrophotometric standardization. Such a reference material is needed in clinical enzymology to establish the proper molar absorptivity of 4-nitrophenol under final reaction conditions, particularly for measuring alkaline phosphatase act...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bowers GN Jr,McComb RB,Christensen RG,Schaffer R

    更新日期:1980-05-01 00:00:00

  • Amniotic fluid acetylcholinesterase activity and alpha-fetoprotein in chromosomal anomalies and neural tube defects.

    abstract::Measurement of alpha-fetoprotein concentration and acetylcholinesterase activity in amniotic fluid can be used to identify chromosomal defects as well as neural tube defects. In seven cases of trisomy 21 and one case of partial trisomy 3, alpha-fetoprotein concentrations were below the reference range but values for a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buamah PK,Skillen AW,Harrison J,Davison V

    更新日期:1985-04-01 00:00:00

  • Evaluation of "HemoCue," a new device for determining hemoglobin.

    abstract::Hemoglobinometry according to the International Committee of Standardization in Hematology (ICSH) suffers from imprecision related to high sample dilution and from potential errors owing to sample turbidity. We have evaluated a new instrument, "HemoCue," that measures hemoglobin at two wavelengths as azide methemoglob...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Schenck H,Falkensson M,Lundberg B

    更新日期:1986-03-01 00:00:00

  • Clinical applications of protein determinations in biological fluids other than blood.

    abstract::Over the past decade, significant improvements in immunochemical and electrophoretic techniques have enabled collection of heretofore unavailable data on proteins in biological fluids, greatly increasing our understanding of protein physiology in the various body compartments and providing the foundation for clinical ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Killingsworth LM

    更新日期:1982-05-01 00:00:00

  • Double-monoclonal immunofluorometric assays for pregnancy-associated plasma protein A/proeosinophil major basic protein (PAPP-A/proMBP) complex in first-trimester maternal serum screening for Down syndrome.

    abstract::Four double-monoclonal time-resolved immunofluorometric assays (TrIFMAs) have been developed for the specific determination of pregnancy-associated plasma protein A/proeosinophil major basic protein (PAPP-A/ proMBP) complex in first-trimester maternal serum samples. The assays have a functional sensitivity of < 4 mIU/...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Qin QP,Christiansen M,Oxvig C,Pettersson K,Sottrup-Jensen L,Koch C,Nørgaard-Pedersen B

    更新日期:1997-12-01 00:00:00

  • The haptoglobin 2-2 phenotype affects serum markers of iron status in healthy males.

    abstract:BACKGROUND:Human iron status is influenced by environmental and genetic factors. We hypothesized that the genetic polymorphism of haptoglobin (Hp), a hemoglobin-binding plasma protein, could affect iron status. METHODS:Reference values of serum iron status markers were compared according to Hp phenotypes (Hp 1-1, Hp 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Langlois MR,Martin ME,Boelaert JR,Beaumont C,Taes YE,De Buyzere ML,Bernard DR,Neels HM,Delanghe JR

    更新日期:2000-10-01 00:00:00

  • Novel protein markers of acute coronary syndrome complications in low-risk outpatients: a systematic review of potential use in the emergency department.

    abstract:BACKGROUND:Published literature was systematically reviewed to determine the diagnostic accuracy of new protein markers of acute coronary syndromes (ACS) in symptomatic outpatients at low risk of ACS and related complications comparable to patients evaluated in emergency department chest pain units. METHODS:Studies we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2005.052456

    authors: Mitchell AM,Brown MD,Menown IB,Kline JA

    更新日期:2005-11-01 00:00:00

  • Clinical evaluation of the Elecsys beta-CrossLaps serum assay, a new assay for degradation products of type I collagen C-tlopeptides.

    abstract:BACKGROUND:The Elecsys beta-CrossLaps serum assay measures type I collagen degradation fragments (beta-CTx) that contain the beta-isomerized octapeptide EKAHD-beta-GGR. We investigated the analytical performance of the assay and changes in beta-CrossLaps in patients with metabolic bone diseases. METHODS:The electroche...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Okabe R,Nakatsuka K,Inaba M,Miki T,Naka H,Masaki H,Moriguchi A,Nishizawa Y

    更新日期:2001-08-01 00:00:00

  • Liquid chromatographic analysis of disopyramide and its mono-N-dealkylated metabolite.

    abstract::We describe a rapid, sensitive, and specific "high performance" liquid chromatographic analysis for disopyramide and its mono-N-dealkylated metabolite in serum, urine, and saliva. We used a mu-Bondapak CN column and an acetate buffer mobile phase containing methanol. Retention times for the two compounds and the inter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lima JJ

    更新日期:1979-03-01 00:00:00

  • The metabolic syndrome: requiescat in pace.

    abstract::Values for insulin-mediated glucose disposal vary continuously throughout a population of apparently healthy individuals, with at least a sixfold variation between the most insulin sensitive and most insulin resistant of these individuals. The more insulin resistant a person, the more insulin must be secreted to preve...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2005.048611

    authors: Reaven GM

    更新日期:2005-06-01 00:00:00

  • Liquid Chromatography-Tandem Mass Spectrometry Assay of Leukocyte Acid α-Glucosidase for Post-Newborn Screening Evaluation of Pompe Disease.

    abstract:BACKGROUND:Pompe disease (PD) is the first lysosomal storage disorder to be added to the Recommended Uniform Screening Panel for newborn screening. This condition has a broad phenotypic spectrum, ranging from an infantile form (IOPD), with severe morbidity and mortality in infancy, to a late-onset form (LOPD) with vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.259036

    authors: Lin N,Huang J,Violante S,Orsini JJ,Caggana M,Hughes EE,Stevens C,DiAntonio L,Chieh Liao H,Hong X,Ghomashchi F,Babu Kumar A,Zhou H,Kornreich R,Wasserstein M,Gelb MH,Yu C

    更新日期:2017-04-01 00:00:00

  • Quantitative homogeneous enzyme immunoassays for amitriptyline, nortriptyline, imipramine, and desipramine.

    abstract::We describe specific EMIT homogeneous enzyme immunoassays for amitriptyline, nortriptyline, imipramine, and desipramine in patients' serum samples. Before analysis, an easily performed extraction step involving the use of 500 microL of sample and a 1-mL disposable column eliminates cross-reacting polar metabolites. Th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pankey S,Collins C,Jaklitsch A,Izutsu A,Hu M,Pirio M,Singh P

    更新日期:1986-05-01 00:00:00

  • Circadian variations and reference intervals for some enzymes in urine of healthy children.

    abstract::Circadian variations of alanine aminopeptidase (EC 3.4.11.2), gamma-glutamyltransferase (EC 2.3.2.2), and N-acetyl-beta-glucosaminidase (EC 3.2.1.30) in urine were studied in 10 healthy children, ages six to 15 years. Urine specimens were collected during 24 h, grouped into four time intervals. Enzymes were measured s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Feldmann D,Flandrois C,Jardel A,Phan TM,Aymard P

    更新日期:1989-05-01 00:00:00

  • Monoclonal antibody inhibiting creatine kinase MM3 but not isoform MM1.

    abstract::Monoclonal antibody CKM-G01 inhibited greater than 99% of the activity of porcine and human creatine kinase(CK)-MM isoenzyme purified from muscle. However, it inhibited only 54% of CK-MM in human serum. Chromatofocusing of serum CK-MM showed that CKM-G01 inhibited 100% of MM3 but not isoform MM1. CKM-G01 inhibited CK-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suzuki T,Shiraishi T,Tomita K,Totani M,Murachi T

    更新日期:1990-01-01 00:00:00

  • Development of an immunoassay for the quantification of soluble LR11, a circulating marker of atherosclerosis.

    abstract:BACKGROUND:Vascular smooth muscle cells (SMCs) migrate from the arterial media to the intima in the progression of atherosclerosis, and dysfunction of SMCs leads to enhanced atherogenesis. A soluble form of the LDL receptor relative with 11 ligand-binding repeats (sLR11) is produced by the intimal SMCs, and the circula...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.127027

    authors: Matsuo M,Ebinuma H,Fukamachi I,Jiang M,Bujo H,Saito Y

    更新日期:2009-10-01 00:00:00

  • High urinary concentrations of activin A in asphyxiated full-term newborns with moderate or severe hypoxic ischemic encephalopathy.

    abstract:BACKGROUND:Hypoxic ischemic encephalopathy (HIE) is a major cause of permanent neurological disabilities in full-term newborns. We measured activin A in urine collected immediately after birth in asphyxiated full-term newborns, and assessed the ability of the measurements to predict the occurrence of perinatal encephal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.062604

    authors: Florio P,Luisi S,Moataza B,Torricelli M,Iman I,Hala M,Hanna A,Petraglia F,Gazzolo D

    更新日期:2007-03-01 00:00:00

  • Glycated proteins in serum: effect of their relative proportions on their alkaline reducing activity in the fructosamine test.

    abstract::The fructosamine test is considered clinically useful for assessing short-term integrated control of blood glucose, but there are few published data to support this hypothesis. We fractionated glycated and nonglycated proteins by affinity chromatography on phenylboronate columns and, with specific immunochemical metho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Zoppi F,Mosca A,Granata S,Montalbetti N

    更新日期:1987-10-01 00:00:00

  • Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains.

    abstract:BACKGROUND:The detection of monoclonal free light chains (FLCs) is an important diagnostic aid for a variety of monoclonal gammopathies and is especially important in light-chain diseases, such as light-chain myeloma, primary systemic amyloidosis, and light-chain-deposition disease. These diseases are more prevalent in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Katzmann JA,Clark RJ,Abraham RS,Bryant S,Lymp JF,Bradwell AR,Kyle RA

    更新日期:2002-09-01 00:00:00

  • Multicenter evaluation of human placental alkaline phosphatase as a possible tumor-associated antigen in serum.

    abstract::Using a solid-phase monoclonal antibody enzyme immuno-assay, we evaluated in a multicenter study (18 laboratories) the utility of evaluating catalytic activity of human placental alkaline phosphatase (hPLAP, EC 3.1.3.1) in serum as a potential tumor marker. We determined hPLAP in serum samples from 130 patients with o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: De Broe ME,Pollet DE

    更新日期:1988-10-01 00:00:00

  • Characterization of a new certified reference material for human cardiac troponin I.

    abstract:BACKGROUND:To address the continuing need for the standardization of clinical human cardiac troponin I (cTnI) assays, NIST, with the assistance of the AACC/IFCC Cardiac Troponin I Standardization Committee, has developed a new certified reference material, Standard Reference Material (SRM) 2921: Human Cardiac Troponin ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051359

    authors: Bunk DM,Welch MJ

    更新日期:2006-02-01 00:00:00

  • Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

    abstract::We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jiménez A,Arenas J,Santos I,Martínez A

    更新日期:1986-08-01 00:00:00

  • Circulating fragments of N-terminal pro-B-type natriuretic peptides in plasma of heart failure patients.

    abstract:BACKGROUND:The use of nonstandardized N-terminal pro-B-type natriuretic peptide (NT-proBNP) assays can contribute to the misdiagnosis of heart failure (HF). Moreover, there is yet to be established a common consensus regarding the circulating forms of NT-proBNP being used in current assays. We aimed to characterize and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.200204

    authors: Foo JY,Wan Y,Schulz BL,Kostner K,Atherton J,Cooper-White J,Dimeski G,Punyadeera C

    更新日期:2013-10-01 00:00:00

  • Completeness of Reporting of Systematic Reviews of Diagnostic Test Accuracy Based on the PRISMA-DTA Reporting Guideline.

    abstract:BACKGROUND:We evaluated the completeness of reporting of diagnostic test accuracy (DTA) systematic reviews using the recently developed Preferred Reporting Items for Systematic Reviews and MetaAnalyses (PRISMA)-DTA guidelines. METHODS:MEDLINE® was searched for DTA systematic reviews published October 2017 to January 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2018.292987

    authors: Salameh JP,McInnes MDF,Moher D,Thombs BD,McGrath TA,Frank R,Dehmoobad Sharifabadi A,Kraaijpoel N,Levis B,Bossuyt PM

    更新日期:2019-02-01 00:00:00

  • Liquid chromatography-isotope dilution-mass spectrometry as a new basis for the reference measurement procedure for hemoglobin A1c determination.

    abstract:BACKGROUND:Standardization of hemoglobin (Hb)A(1c) measurements is a process of considerable interest for quality assurance in diabetes management. To contribute to continuous quality improvement and fulfillment of the requirements for reference measurement procedures according to the standards of the International Org...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.139477

    authors: Kaiser P,Akerboom T,Ohlendorf R,Reinauer H

    更新日期:2010-05-01 00:00:00