Non-enzymic glycation of individual plasma proteins in normoglycemic and hyperglycemic patients.

Abstract:

:Diabetic patients in poor glycemic control show increased glycation of total plasma proteins, but little is yet known about the relative extents to which the various individual proteins are glycated. Thus, we studied the non-enzymic glycation of several major plasma proteins and plasma protein fractions in normal and diabetic patients. In vivo glycation for most plasma proteins was very low in non-diabetic patients, only gamma globulin showing more than 5% glycation. In diabetic plasmas, glycation was much greater, immunoglobulins again showing the greatest proportion, followed in descending order by albumin, complement C3, fibrinogen, transferrin, haptoglobin, and alpha-1-antitrypsin. When plasma proteins were glycated in vitro, this order was IgG greater than complement C3 greater than albumin greater than transferrin greater than haptoglobin greater than alpha-1-antitrypsin. In general, proteins with the longest biological half-lives, such as IgG and albumin, showed the greatest in vivo glycation. On the other hand, proteins with high intrinsic glycability, such as complement C3, showed moderate glycation, despite a short half-life. Except for albumin, more basic proteins showed greater glycation than acidic proteins, but there was poor correlation between mole percent lysine and glycation. Evidently the relative extents of glycation of different plasma proteins are a complex function of integrated glucose concentrations over time and of the half-life and chemical characteristics of each protein.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Austin GE,Mullins RH,Morin LG

subject

Has Abstract

pub_date

1987-12-01 00:00:00

pages

2220-4

issue

12

eissn

0009-9147

issn

1530-8561

journal_volume

33

pub_type

杂志文章
  • Primidone analyses: correlation of gas-chromatographic assay with enzyme immunoassay.

    abstract::Serum specimens from patients on primidone therapy were assayed by two currently available procedures: a commercially available enzyme immunoassay (EMIT) and a published gas-chromatographic procedure. Both procedures were done with commercially available materials and equipment. Results by the two procedures agreed we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sun L,Walwick ER

    更新日期:1976-06-01 00:00:00

  • Seven different assays of hyaluronan compared for clinical utility.

    abstract::To compare six assays of hyaluronan (hyaluronic acid; HYA) in serum, developed in different laboratories, we analyzed 10 samples from each of three groups: healthy persons, patients with primary biliary cirrhosis, and patients with rheumatoid arthritis. All the assays are based on the use of affinity proteins specific...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lindqvist U,Chichibu K,Delpech B,Goldberg RL,Knudson W,Poole AR,Laurent TC

    更新日期:1992-01-01 00:00:00

  • Acetate intolerance and an inhibitor of acetate utilization in hemodialysis patients.

    abstract::Diminished ability to utilize acetate (acetate intolerance) developed in a male patient on chronic hemodialysis after five years of maintenance dialysis. His ability to utilize lactate was also subnormal. We studied acetate metabolism in vitro by isolating lymphocytes from the patient's blood before dialysis and measu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Egan JD,Wells IC

    更新日期:1979-03-01 00:00:00

  • Myoglobin concentration, creatine kinase activity, and creatine kinase B subunit concentrations in serum during thyroid disease.

    abstract::Changes in values for myoglobin, total creatine kinase (EC 2.7.3.2), and creatine kinase B-subunit in the serum of patients with thyroid disease are compared with values for these during the 24-h after myocardial infarction. Concentrations of all three of these muscle-derived proteins were significantly higher than no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Docherty I,Harrop JS,Hine KR,Hopton MR,Matthews HL,Taylor CJ

    更新日期:1984-01-01 00:00:00

  • Modified method for determining carcinoembryonic antigen in the presence of human anti-murine antibodies.

    abstract::The increasing use of monoclonal antibodies (MAbs) for disease diagnosis and therapy has created a class of patients at risk for systematic error in clinical testing due to interference by human anti-murine antibodies (HAMA). HAMA interference is often difficult to detect and can cause either an increase or a decrease...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morrissey NE,Quadri SF,Kinders R,Brigham C,Rose S,Blend MJ

    更新日期:1993-03-01 00:00:00

  • Measurement of different forms of tissue plasminogen activator in plasma.

    abstract:BACKGROUND:We evaluated assays to measure both total tissue plasminogen activator (tPA) and the three principle forms of tPA in plasma: active tPA, tPA complexed with plasminogen activator inhibitor type 1 (PAI-1), and tPA complexed with C1-inhibitor. METHODS:Active tPA was measured by use of an indirect amidolytic as...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chandler WL,Jascur ML,Henderson PJ

    更新日期:2000-01-01 00:00:00

  • Proteasome inhibition measurements: clinical application.

    abstract:BACKGROUND:PS-341, a selective inhibitor of the proteasome, currently is under evaluation as an anticancer agent in multiple phase I clinical trials. In animal-model studies, PS-341 was rapidly removed from the vascular compartment and distributed widely, quickly approaching the limits of detection. An accurate pharmac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lightcap ES,McCormack TA,Pien CS,Chau V,Adams J,Elliott PJ

    更新日期:2000-05-01 00:00:00

  • Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

    abstract:BACKGROUND:In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. MET...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.067116

    authors: Sauvage FL,Saint-Marcoux F,Duretz B,Deporte D,Lachatre G,Marquet P

    更新日期:2006-09-01 00:00:00

  • Cobalamin-binding capacity of haptocorrin and transcobalamin: age-correlated reference intervals and values from patients.

    abstract::Unsaturated cobalamin-binding capacity in plasma (P-UBBC) is determined by use of a silica gel (QUSO G32) to separate haptocorrin (P-ApoHC) and transcobalamin (P-ApoTC). The method is sensitive and precise: detection limit 13 pmol/L, interassay coefficients of variation 3% for P-UBBC (mean = 1080 pmol/L), 4% for P-Apo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gimsing P,Nexø E

    更新日期:1989-07-01 00:00:00

  • Determination of inorganic arsenic and its organic metabolites in urine by flow-injection hydride generation atomic absorption spectrometry.

    abstract::A method has been developed for the determination of inorganic arsenic [As(III) and As(V)] and its organic metabolites (monomethylarsenic and dimethylarsenic) in urine by flow-injection hydride generation atomic absorption spectrometry. The nontoxic seafood-derived arsenobetaine and arsenocholine species were first se...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hanna CP,Tyson JF,McIntosh S

    更新日期:1993-08-01 00:00:00

  • Evaluation of a fully automated serum assay for C-terminal cross-linking telopeptide of type I collagen in osteoporosis.

    abstract:BACKGROUND:Biochemical markers of bone turnover can provide prognostic information about the risk of osteoporotic fracture and are useful tools for monitoring efficacy of antiresorptive therapy. A serum-based automated assay may be of better clinical value than urinary markers because of lower imprecision and day-to-da...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garnero P,Borel O,Delmas PD

    更新日期:2001-04-01 00:00:00

  • Standardization of C-peptide measurements.

    abstract:BACKGROUND:C-peptide is a marker of insulin secretion in diabetic patients. We assessed within- and between-laboratory imprecision of C-peptide assays and determined whether serum calibrators with values assigned by mass spectrometry could be used to harmonize C-peptide results. METHODS:We sent 40 different serum samp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2007.101287

    authors: Little RR,Rohlfing CL,Tennill AL,Madsen RW,Polonsky KS,Myers GL,Greenbaum CJ,Palmer JP,Rogatsky E,Stein DT

    更新日期:2008-06-01 00:00:00

  • Kinetic centrifugal analyzer and manual determination of serum urea nitrogen, with use of o-phthaldialdehyde reagent.

    abstract::o-Phthaldialdehdye reagent was used in assaying urea with a miniature centrifugal analyzer. Seventeen samples can be assayed kinetically in 2 min at a current cost of less than a penny per test. The reaction is initiated in the instrument upon simultaneous mixing of the o-phthaldialdehyde reagent containing 10 microli...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levinson SS

    更新日期:1978-12-01 00:00:00

  • Apolipoprotein B and A-I values in 147576 Swedish males and females, standardized according to the World Health Organization-International Federation of Clinical Chemistry First International Reference Materials.

    abstract::Serum concentrations of apolipoprotein (apo) B and apo A-I were measured from 1985-1996 in a Swedish population sample of 83 112 males and 64 464 females, ages <20 to >80 years, using an automated immunoturbidimetric method calibrated against fresh pools of human serum and commercial calibrators. All values were recal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jungner I,Marcovina SM,Walldius G,Holme I,Kolar W,Steiner E

    更新日期:1998-08-01 00:00:00

  • Carcinoembryonic antigen as a marker for colorectal cancer: is it clinically useful?

    abstract:BACKGROUND:Carcinoembryonic antigen (CEA) is one of the most widely used tumor markers worldwide. Its main application is mostly in gastrointestinal cancers, especially in colorectal malignancy. Although in use for almost 30 years, the clinical value of CEA in colorectal cancer is still not clear. METHODS:The literatu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Duffy MJ

    更新日期:2001-04-01 00:00:00

  • Association of changes in oxidative and proinflammatory states with changes in vascular function after a lifestyle modification trial among obese children.

    abstract:BACKGROUND:The association of changes in oxidative and proinflammatory states with vascular function after diet and exercise intervention among obese children has not been previously explored. METHODS:In this 6-week diet and exercise intervention study in 35 obese children, age 12 to 18 years, we evaluated the relatio...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2007.089953

    authors: Kelishadi R,Hashemi M,Mohammadifard N,Asgary S,Khavarian N

    更新日期:2008-01-01 00:00:00

  • Continuous-flow enzymic determination of creatine in urine.

    abstract::A new enzymic method is described for the determination of creatine in urine by continuous-flow analysis. The measurement is accomplished by transforming creatine to formaldehyde in reactions catalyzed by creatinase (creatine amidinohydrolase) and sarcosine dehydrogenase. The formaldehyde is reacted with 4-amino-3-hyd...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Yasuhara M,Fujita S,Furukawa I,Arisue K,Kohda K,Hayashi C

    更新日期:1981-11-01 00:00:00

  • Multiplex SNaPshot genotyping for detecting loss of heterozygosity in the mismatch-repair genes MLH1 and MSH2 in microsatellite-unstable tumors.

    abstract:BACKGROUND:In the workup of patients with suspected hereditary nonpolyposis colorectal cancer (HNPCC), detection of loss of heterozygosity (LOH) could help pinpoint the mismatch-repair (MMR) gene carrying the germline mutation, but analysis of microsatellite markers has proved unreliable for this purpose. We developed ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.108902

    authors: Bujalkova M,Zavodna K,Krivulcik T,Ilencikova D,Wolf B,Kovac M,Karner-Hanusch J,Heinimann K,Marra G,Jiricny J,Bartosova Z

    更新日期:2008-11-01 00:00:00

  • Diagnosis of type III hyperlipoproteinemia by chromatography of plasma lipoproteins on columns containing agarose.

    abstract::Agarose column chromatography has been used to separate plasma lipoproteins into very-low-density lipoproteins (VLDL), low-density lipoproteins (LDL) and high-density lipoproteins (HDL). Applied to the diagnosis of primary type III hyperlipoproteinemia, the procedure is capable of demonstrating three characteristic an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shepherd J,Packard CJ,Dryburgh FJ,Third JL

    更新日期:1975-12-01 00:00:00

  • Kinetics of the reactions of unconjugated and conjugated bilirubins with p-diazobenzenesulfonic acid.

    abstract::We report the kinetics of the reactions of unconjugated bilirubin and conjugated bilirubin with p-diazobenzene sulfonic acid in aqueous media. Our studies confirm that each reaction proceeds in two steps and that the second step is catalyzed by sulfanilic acid. In the presence of an excess of p-diazobenzenesulfonic ac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Landis JB,Pardue HL

    更新日期:1978-10-01 00:00:00

  • Potentiometry of Na+ in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode.

    abstract::We present an improved Na+-selective liquid membrane electrode for measurement of Na+ concentrations in both undiluted serum and urine. The values for urinary Na+ obtained with the ion-selective electrode agree well with those obtained with the flame photometer. The correlation gives a standard residual deviation of +...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Anker P,Jenny HB,Wuthier U,Asper R,Ammann D,Simon W

    更新日期:1983-08-01 00:00:00

  • A sensitive liquid-chromatographic method for determination of 3'-azido-3'-deoxythymidine (AZT) in plasma and urine.

    abstract::We describe a liquid-chromatographic assay for AZT in human plasma and urine. This assay involves the use of two internal standards, allowing reference of AZT peaks to the appropriate internal standard, the choice depending on the range of concentrations encountered. This method is isocratic, specific, sensitive enoug...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hedaya MA,Sawchuk RJ

    更新日期:1988-08-01 00:00:00

  • High-throughput genotyping of thiopurine S-methyltransferase by denaturing HPLC.

    abstract:BACKGROUND:The thiopurine S:-methyltransferase (TPMT) genetic polymorphism has a significant clinical impact on the toxicity of thiopurine drugs, which are used in the treatment of leukemia and as immunosuppressants. To date, 10 mutant alleles are known that are associated with intermediate or low TPMT activity. To fac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schaeffeler E,Lang T,Zanger UM,Eichelbaum M,Schwab M

    更新日期:2001-03-01 00:00:00

  • The "HemoQuant" test: a specific and quantitative determination of heme (hemoglobin) in feces and other materials.

    abstract::We describe a new, specific, quantitative method for fecal blood, based on conversion of nonfluorescing heme to fluorescing porphyrins, that obviates serious deficiencies inherent in currently used tests. A two-reagent system is used to determine the two hemoglobin-related fractions that are found in feces. The hot ci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schwartz S,Dahl J,Ellefson M,Ahlquist D

    更新日期:1983-12-01 00:00:00

  • Variability in the relationship between mean plasma glucose and HbA1c: implications for the assessment of glycemic control.

    abstract:BACKGROUND:Previous studies have shown a single linear relationship between mean plasma glucose (MPG) and hemoglobin A(1c) (HbA(1c)). We examined the relationship in different treatment groups of patients with type 1 diabetes participating in the Diabetes Control and Complications Trial (DCCT). METHODS:Seven-point glu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.079756

    authors: Kilpatrick ES,Rigby AS,Atkin SL

    更新日期:2007-05-01 00:00:00

  • Adenosine deaminase binding protein, a new diagnostic marker for kidney disease.

    abstract::This enzyme immunoassay detects adenosine deaminase binding protein (ABP), a glycoprotein that is shed from the brush border of the proximal tubule in kidney damage. Two monoclonal antibodies, URO-4 and URO-4a, each react with different epitopes on ABP and are used as the "sandwich" pair of antibodies. A linear standa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson RE,Piper DJ,Galberg C,Chan TH,Tolkoff-Rubin NE,Rubin RH

    更新日期:1985-05-01 00:00:00

  • Measurement of urinary oxalate and citrate by capillary electrophoresis and indirect ultraviolet absorbance.

    abstract::We describe a method for measuring urinary oxalate and citrate with capillary electrophoresis (CE) and indirect ultraviolet absorbance detection. Sample preparation is minimal, requiring an acidification, brief centrifugation, and dilution. The method is rapid, with oxalate and citrate having mean migration times of 4...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Holmes RP

    更新日期:1995-09-01 00:00:00

  • Laboratory computing--process and information management supporting high-quality, cost-effective healthcare.

    abstract::One currently observes many healthcare institutions rushing to reengineer and install information systems with the expectation of achieving enhanced efficiency, competitiveness, and, it is hoped, higher patient satisfaction resulting from timely, high-quality care. Unfortunately, information system concepts, design, a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Buffone GJ,Moreau DR

    更新日期:1995-09-01 00:00:00

  • Radiolabeled polymerase chain reaction assay for detection of ras oncogene point mutations in tumors.

    abstract::The human ras gene plays a fundamental role in the transduction of extracellular signals to the nucleus, thereby regulating cell growth and differentiation. Point mutations in the ras gene convert it into a transforming oncogene that has been found in many solid and hematologic malignancies. We describe a rapid and se...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aoki Y,Lee JC,Pillai S,Isselbacher KJ,Rustgi AK

    更新日期:1994-05-01 00:00:00

  • Subclass typing of IgG paraproteins by immunofixation electrophoresis.

    abstract::We present a simple method for subclass typing of IgG paraproteins, with which we have demonstrated a large number of paraproteins that were undetected by conventional immunofixation techniques. The types and distribution of IgG subclass paraproteins were analyzed in 92 human sera in which IgG paraproteins had been de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Klouche M,Bradwell AR,Wilhelm D,Kirchner H

    更新日期:1995-10-01 00:00:00