An unusual case of toluene-induced metabolic acidosis.

Abstract:

:We used gas chromatography-mass spectrometry to analyze serum specimens from a patient whose metabolic ketoacidosis resulted from sniffing a toluene-containing substance; we also analyzed a sample of the abused substance itself and a serum specimen from a normal subject. The blood samples from the patient showed abnormally high concentrations of acetoacetic, azelaic, benzoic, and 3-hydroxybutyric acids, and a smaller amount of hippuric acid than in the control serum. The ketone bodies and benzoic acid appeared to be factors contributing to her acidosis and ketosis. Analysis for volatile solvents in the patient's serum revealed a low concentration of methyl acetate, in contrast to the high concentrations of toluene and bis(2-ethylhexyl) phthalate and the trace concentration of xylene in the abused substance. We consider this case unusual because the presence and concentration of specific ketoacids was unexpected in light of what was known about the patient.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Jone CM,Wu AH

subject

Has Abstract

pub_date

1988-12-01 00:00:00

pages

2596-9

issue

12

eissn

0009-9147

issn

1530-8561

journal_volume

34

pub_type

杂志文章
  • Reference centiles for serum ferritin and percentage of transferrin saturation, with application to mutations of the HFE gene.

    abstract:BACKGROUND:The gene that causes most cases of hereditary hemochromatosis is designated HFE. Individuals with mutations in the HFE gene may have increased serum iron, transferrin saturation, and ferritin concentrations relative to individuals with the wild-type genotype. METHODS:We generated reference centiles for perc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Koziol JA,Ho NJ,Felitti VJ,Beutler E

    更新日期:2001-10-01 00:00:00

  • Radioimmunoassay of thyroxine in 10 microliters of serum, with use of aggregated antithyroxine antibodies.

    abstract::We describe a sensitive radioimmunoassay for rapidly determining the concentration of thyroxine in 10 microL of human serum. Aggregated antithyroxine antibodies are used to separate bound and free hormone. This speeds the assay and economizes on reagents without loss of sensitivity, specificity, or precision. Results ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Collins S,Brooks M,Bermes EW

    更新日期:1980-03-01 00:00:00

  • The clinical utility of high-sensitivity C-reactive protein in cardiovascular disease and the potential implication of JUPITER on current practice guidelines.

    abstract:BACKGROUND:High-sensitivity C-reactive protein (hsCRP) testing is relatively inexpensive and has been shown to predict the risk of cardiovascular disease (CVD) and diabetes in multiple patient groups, including those treated with statin therapy. JUPITER (Justification for the Use of Statins in Primary Prevention: An In...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.109728

    authors: Mora S,Musunuru K,Blumenthal RS

    更新日期:2009-02-01 00:00:00

  • Oligosaccharide analysis in urine by maldi-tof mass spectrometry for the diagnosis of lysosomal storage diseases.

    abstract:BACKGROUND:There are 45 known genetic diseases that impair the lysosomal degradation of macromolecules. The loss of a single lysosomal hydrolase leads to the accumulation of its undegraded substrates in tissues and increases of related glycoconjugates in urine, some of which can be detected by screening of free oligosa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.201053

    authors: Xia B,Asif G,Arthur L,Pervaiz MA,Li X,Liu R,Cummings RD,He M

    更新日期:2013-09-01 00:00:00

  • Single-Stranded DNA Library Preparation Preferentially Enriches Short Maternal DNA in Maternal Plasma.

    abstract:BACKGROUND:Recent studies have suggested that single-stranded DNA (ssDNA) library preparation can enrich short DNA species from the plasma of healthy individuals, cancer patients, and transplant recipients. Based on previous observations that fetal DNA molecules in the maternal plasma are shorter than maternal DNA mole...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.268656

    authors: Vong JSL,Tsang JCH,Jiang P,Lee WS,Leung TY,Chan KCA,Chiu RWK,Lo YMD

    更新日期:2017-05-01 00:00:00

  • Rapid liquid chromatography-tandem mass spectrometry method for routine analysis of cyclosporin A over an extended concentration range.

    abstract:BACKGROUND:Cyclosporin A (CsA) is commonly measured by immunoassay techniques that have a limited analytical range. The consequence of this is that low CsA concentrations that may be clinically significant are difficult to measure and that high concentrations require sample dilution, which introduces error and increase...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Keevil BG,Tierney DP,Cooper DP,Morris MR

    更新日期:2002-01-01 00:00:00

  • Flow-injection analysis with chemiluminescence detection.

    abstract::In "flow-injection analysis," the sample is inserted into a stream of reagent by use of a sample-injection valve. Mixing occurs downstream from the valve in a coil of tubing. With chemiluminescence detection this coil is positioned in front of a photomultiplier. We have evaluated the system for detection of hydrogen p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rule G,Seitz WR

    更新日期:1979-09-01 00:00:00

  • Concentrations of zinc, iron, molybdenum, arsenic, and lithium in cerebrospinal fluid of patients with brain tumors.

    abstract::We used flameless atomic absorption spectrophotometry to measure concentrations of Fe, Mo, Li, As, and Zn in cerebrospinal fluid (CSF) of patients with malignant brain tumors benign brain tumors, non-brain malignant tumors and control (non-neoplastic disease) patients. Mean (and SD) concentrations (microgram/L) of the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: el-Yazigi A,Al-Saleh I,Al-Mefty O

    更新日期:1986-12-01 00:00:00

  • Tumor necrosis factor-alpha -308G>A allelic variant modulates iron accumulation in patients with hereditary hemochromatosis.

    abstract:BACKGROUND:In vitro and animal studies suggest that tumor necrosis factor alpha (TNF-alpha) modulates intestinal iron transport. We hypothesized that the effect of TNF-alpha might be particularly relevant if iron absorption is not effectively controlled by the HFE gene. METHODS:In patients with homozygous C282Y hemoch...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065417

    authors: Krayenbuehl PA,Maly FE,Hersberger M,Wiesli P,Himmelmann A,Eid K,Greminger P,Vetter W,Schulthess G

    更新日期:2006-08-01 00:00:00

  • Analysis for platinum in biological material by flameless atomic absorption spectrometry.

    abstract::A method for determining platinum in biological materials by flameless atomic absorption spectrometry has been developed for use in pharmacological studies of platinum antitumor compounds. Tissue digests are analyzed in a heated graphite atomizer, with use of background correction and ramp temperature charring. We hav...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pera MF Jr,Harder HC

    更新日期:1977-07-01 00:00:00

  • Gas-chromatographic determination of amantadine in human urine.

    abstract::We describe a gas--liquid-chromatographic method for determining the concentration of amantadine hydrochloride in urine with beta-phenylethylamine as internal standard. The urine sample is made alkaline and extracted with 0.5 mL of chloroform. After centrifugation the aqueous layer is aspirated, and an aliquot of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stumph MJ,Noall MW,Knight V

    更新日期:1980-02-01 00:00:00

  • Simultaneous measurement of eight corticosteroids by liquid chromatography, and application of the procedure to diagnosis of congenital adrenal hyperplasia.

    abstract::We describe a liquid-chromatographic procedure for simultaneously determining eight steroids in serum. We used a Zorbax ODS column and a mobile phase of methanol/isopropanol/water (44/10/46, by vol), which well resolves the steroids cortisone, cortisol, corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, androst...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wei JQ,Zhou XT,Wei JI

    更新日期:1987-08-01 00:00:00

  • Modified pentamer formation assay for measurement of tacrolimus and its active metabolites: comparison with liquid chromatography-tandem mass spectrometry and microparticle enzyme-linked immunoassay (MEIA-II).

    abstract::A modified pentamer formation assay (PFA) for quantification of tacrolimus and active metabolites after extraction from whole blood is described. The lower limit of detection was 2 microg/L. Intraassay precision (CV) was 5.7-13.7%, and the interassay CV was 6. 1-14.9%. Tacrolimus trough concentrations in 104 whole blo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Armstrong VW,Schuetz E,Zhang Q,Groothuisen S,Scholz C,Shipkova M,Aboleneen H,Oellerich M

    更新日期:1998-12-01 00:00:00

  • Creatine kinase in serum: 6. Inhibition by endogenous polyvalent cations, and effect of chelators on the activity and stability of some assay components.

    abstract::We studied the effects of some chelators on creatine kinase activity. Creatine kinase is competitively inhibited by endogenous polyvalent cations (e.g., calcium, Ki = 4.5 mmol/L); this can be reversed by adding chelators to the reagent, resulting in a mean increase in activity of 1.14-fold at 25 degrees C and 1.18-fol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Szasz G,Waldenström J,Gruber W

    更新日期:1979-03-01 00:00:00

  • A "Culture" Shift: Broad Bacterial Detection, Identification, and Antimicrobial Susceptibility Testing Directly from Whole Blood.

    abstract:BACKGROUND:The time required for bloodstream pathogen detection, identification (ID), and antimicrobial susceptibility testing (AST) does not satisfy the acute needs of disease management. Conventional methods take up to 3 days for ID and AST. Molecular diagnostics have reduced times for ID, but their promise to suppla...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.290189

    authors: Andini N,Hu A,Zhou L,Cogill S,Wang TH,Wittwer CT,Yang S

    更新日期:2018-10-01 00:00:00

  • Quantification of urinary oxalate with oxalate oxidase from beet stems.

    abstract::We describe an automated (ABA-100) enzymic method for determination of urinary oxalate by use of oxalate oxidase (EC 1.2.3.4) isolated from beet stems. The H2O2 produced by the oxidation of oxalate by oxalate oxidase is measured by coupling with oxidation and conjugation of 3-methyl-3-benzothiazolinone hydrazone with ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Obzansky DM,Richardson KE

    更新日期:1983-10-01 00:00:00

  • Gas-chromatographic analysis for chlorpromazine and some of its metabolites in human serum, with use of a nitrogen detector.

    abstract::We describe a gas-chromatographic method for measuring chlorpromazine and its metabolites chlorpromazine sulfoxide, mono-N-desmethylchlorpromazine, and di-N-desmethylchlorpromazine at therapeutic concentrations in human serum, with use of a nitrogen detector. The compounds are extracted from serum at pH 10.5 into hexa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bailey DN,Guba JJ

    更新日期:1979-07-01 00:00:00

  • The Longer, the Better? An Empirical Study of the Extent and Mechanisms of Attenuating Biomarker Associations in Cardiovascular Patient Cohorts.

    abstract:BACKGROUND:Identifying novel risk markers in cardiovascular patients remains a research priority. Longer follow-up generally is considered favorable in such studies, but associations of interest may become attenuated with increasing follow-up. This issue has not been adequately addressed in the context of patient cohor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.263202

    authors: Breitling LP,Mons U,Hahmann H,Koenig W,Rothenbacher D,Brenner H

    更新日期:2017-03-01 00:00:00

  • Troponin T and I assays show decreased concentrations in heparin plasma compared with serum: lower recoveries in early than in late phases of myocardial injury.

    abstract:BACKGROUND:Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS:Blood samples were collected with and withou...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,多中心研究

    doi:

    authors: Gerhardt W,Nordin G,Herbert AK,Burzell BL,Isaksson A,Gustavsson E,Haglund S,Müller-Bardorff M,Katus HA

    更新日期:2000-06-01 00:00:00

  • Diagnostic accuracy of fecal calprotectin assay in distinguishing organic causes of chronic diarrhea from irritable bowel syndrome: a prospective study in adults and children.

    abstract:BACKGROUND:Fecal calprotectin (FC) has been proposed as a marker of inflammatory bowel disease (IBD), but few studies have evaluated its usefulness in patients with chronic diarrhea of various causes. We evaluated the diagnostic accuracy of a FC assay in identifying "organic" causes of chronic diarrhea in consecutive a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.6.861

    authors: Carroccio A,Iacono G,Cottone M,Di Prima L,Cartabellotta F,Cavataio F,Scalici C,Montalto G,Di Fede G,Rini G,Notarbartolo A,Averna MR

    更新日期:2003-06-01 00:00:00

  • Diagnostic utility of C-terminal parathyrin measurement as compared with measurements of N-terminal parathyrin and calcium in serum.

    abstract::We compared results obtained from two parathyrin (parathyroid hormone) assays with differing specificities, using sera from 172 normal donors and from 98 patients with disorders of calcium regulation. Intact parathyrin was measured in both assays; the C-parathyrin assay also measured the 53-84 amino acid C-terminal ho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simon M,Cuan J

    更新日期:1980-11-01 00:00:00

  • Prospective Associations of Systemic and Urinary Choline Metabolites with Incident Type 2 Diabetes.

    abstract:BACKGROUND:Several compounds in the choline oxidation pathway are associated with insulin resistance and prevalent diabetes; however, prospective data are scarce.We explored the relationships between systemic and urinary choline-related metabolites and incident type 2 diabetes in an observational prospective study amon...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.250761

    authors: Svingen GF,Schartum-Hansen H,Pedersen ER,Ueland PM,Tell GS,Mellgren G,Njølstad PR,Seifert R,Strand E,Karlsson T,Nygård O

    更新日期:2016-05-01 00:00:00

  • Multicenter evaluation of [-2]proprostate-specific antigen and the prostate health index for detecting prostate cancer.

    abstract:BACKGROUND:Total prostate-specific antigen (tPSA) is flawed for prostate cancer (PCa) detection. [-2]proprostate-specific antigen (p2PSA), a molecular isoform of free PSA (fPSA), shows higher specificity compared with tPSA or percentage of free PSA (%fPSA). The prostate health index (Phi), a measure based on p2PSA and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2012.195784

    authors: Stephan C,Vincendeau S,Houlgatte A,Cammann H,Jung K,Semjonow A

    更新日期:2013-01-01 00:00:00

  • Effect of carbon cup aging on plasma zinc determination by flameless atomic adosorption spectrometry.

    abstract::Determination of zinc in blood plasma by flameless atomic absorption spectrometry is discussed, with particular reference to the protocol required for the successful use of the Varian-Techtron Carbon Rod Atomizer. Cup aging is shown to be an important factor in limiting the precision of this analytical technique and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chooi MK,Todd JK,Boyd ND

    更新日期:1975-04-01 00:00:00

  • A systematic approach to materials handling in clinical laboratories.

    abstract::I describe the automation/mechanization of several areas of sample processing at SmithKline Beecham Clinical Laboratories. By analyzing and implementing new systems for conveyance and sorting of incoming specimens, specimen processing, within-laboratory specimen delivery, specimen storage and retrieval, and client res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nabb DP

    更新日期:1990-09-01 00:00:00

  • A Novel Protein Glycan-Derived Inflammation Biomarker Independently Predicts Cardiovascular Disease and Modifies the Association of HDL Subclasses with Mortality.

    abstract:BACKGROUND:Evidence suggests that systemic inflammation may adversely impact HDL function. In this study we sought to evaluate the independent and incremental predictive performance of GlycA-a novel serum inflammatory biomarker that is an aggregate measure of enzymatically glycosylated acute phase proteins-and HDL subc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.261636

    authors: McGarrah RW,Kelly JP,Craig DM,Haynes C,Jessee RC,Huffman KM,Kraus WE,Shah SH

    更新日期:2017-01-01 00:00:00

  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • Modifying an enzyme immunoassay of immunoreactive trypsinogen to use time-resolved fluorescence.

    abstract::A coated microtiter-well, enzyme-linked immunometric assay for quantifying immunoreactive trypsinogen in dried blood spots was modified to use time-resolved fluorescence of europium in place of end-point enzymatic color development as the quantification step. The streptavidin-horseradish peroxidase and color developme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ryall RG,Gjerde EM,Gerace RL,Ranieri E

    更新日期:1993-02-01 00:00:00

  • Clinical evaluation of serial blood processing at point of care.

    abstract::The Axial Separation Module (ASM), which separates whole-blood specimens serially in Axial Process Containers (APC), was evaluated for clinical performance at the University of Virginia Health Sciences Center (UVA HSC) in a community-based outpatient laboratory (North Ridge Clinic). We hypothesized that moving the tas...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Estey CA,Felder RA

    更新日期:1997-02-01 00:00:00

  • Comparison of quality-control rules used in clinical chemistry laboratories.

    abstract::Numerous papers have been written to show which combinations of Shewhart-type quality-control charts are optimal for detecting systematic shifts in the mean response of a process, increases in the random error of a process, and linear drift effects in the mean response across the assay batch. One paper by Westgard et ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bishop J,Nix AB

    更新日期:1993-08-01 00:00:00