Abstract:
:We examined the mechanism by which hypertriglyceridemia interferes with the Roche Diagnostics "Amylochrome" procedure for measurement of amylase in lactescent samples with normal and above-normal amylase activity. The serum blank recommended in the Amylochrome protocol to compensate for lactescence remains inappropriately turbid, compared with the test, and is partly responsible for the underestimation of amylase activity. Other major interference is seen when lipoprotein in hyperlipemic samples with above-normal amylase activity reacts with the soluble oligosaccharide-triazinyl dye product of the Amylochrome assay to form a flocculent blue precipitate. The formation of this precipitate in the test, and its removal, diminish lactescence due to lipemia, an effect that cannot be matched by any manipulation of a serum blank procedure. Oligosaccharide-dye product is removed as a component of the precipitate.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Wickus GG,Dukerschein RO,Pierce JR,Davis KDsubject
Has Abstractpub_date
1982-10-01 00:00:00pages
2131-4issue
10eissn
0009-9147issn
1530-8561journal_volume
28pub_type
杂志文章abstract::Six alpha-amylase (EC 3.2.1.1) isoenzymes have been resolved electrophoretically on cellulose acetate membranes in a discontinuous buffer system. The fastest migrating isoenzymes are of salivary origin (S1, S2, S3), the slower ones of pancreatic origin (P1, P2, P3). We determined the amylase isoenzyme distribution in ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-01-01 00:00:00
abstract::Each of 65 laboratories analyzed 10 whole-blood samples for erythrocyte protoporphyrin by one or more of several analytical procedures. These procedures were of two types: (a) extraction of protoporphyrin from the erythrocytes into ethyl acetate/acetic acid, re-extraction into hydrochloric acid, and fluorometric measu...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-12-01 00:00:00
abstract::The carboxyl terminal region of corticotropin (ACTH), (Ala34-Phe-Pro-Glu-Leu-Phe39), a region of the hormone conserved during evolution, served as an antigen for the production of a sequence-specific antiserum. In a radioimmunoassay, peptides that extend toward the amino terminal from Ala34, such as [Tyr,Gly]-ACTH34-3...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-04-01 00:00:00
abstract::We evaluated the homogeneous enzyme immunoassay ("EMIT") of serum thyroxine with use of an ABA- 100 Bichromatic Analyzer, modified with an auxiliary dispenser syringe and a dual probe assembly. The modification allows two reagents to be dispensed at one time. The sera must be pre-treated with 0.1 mol/liter NaOH. The p...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-01-01 00:00:00
abstract::A new type of multilayer film analytical element--consisting of a spreading layer, a blocking layer, an enzymic reagent layer, and a transparent layer--has been developed for blood glucose determination. After a spot of whole blood is dropped on the film, the plasma glucose concentration is determined in 6 min without...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-07-01 00:00:00
abstract::We describe a multiprobe colorimeter that permits the reading of enzyme-linked immunosorbent assays (ELISA) in situ, by use of microhemagglutination plates. The use of dipping probes eliminates interference from meniscus effects and air-bubble entrapment. Detailed validation tests have been done and potential sources ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-04-01 00:00:00
abstract::Pairs of values for serum triiodothyronine and serum triiodothyronine binding capacity were represented as maps of points for euthyroid populations (including subjects who were pregnant or were receiving estrogens) in the age groups 18-50, 51-64, 65-79, and greater than 80 years (504 subjects) and thyrotoxic populatio...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-10-01 00:00:00
abstract::We isolated myoglobin from sheep heart by homogenizing cardiac muscle in 70%-saturated ammonium sulfate, followed by chromatography on a column containing carboxymethyl(CM)-Sephadex gel. Two major isoforms of myoglobin, designated Mb 7.9 and Mb 8.1, were separated by chromatofocusing and were distinguished by their di...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-05-01 00:00:00
abstract::We report a case of Fanconi's anemia with an extremely high proportion of fetal hemoglobin (Hb F). A three-year-old girl with multiple birth defects, mental retardation, and aplastic anemia consistent with Fanconi's anemia showed Hb AF by electrophoresis; the Kleihauer smear showed Hb F in 70% of her erythrocytes. Tot...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-10-01 00:00:00
abstract:BACKGROUND:The "unit" for "enzymic activity" (U = 1 micromol/min) was recommended by the International Union of Biochemistry and Molecular Biology (IUB) in 1961 and is widely used in medical laboratory reports. The general trend in metrology, however, is toward global standardization through defining units coherent wit...
journal_title:Clinical chemistry
pub_type: 历史文章,杂志文章
doi:
更新日期:2002-03-01 00:00:00
abstract::Using different substance concentrations in an aqueous 1.25 mmol/L solution of CaCl2 plus NaCl to a final solution ionic strength of 160 mmol/L, we tested six buffers for their effect on measurements of ionized calcium (Ca2+). Measured Ca2+ decreased with increasing ionic strength and pH. Increasing concentrations of ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-02-01 00:00:00
abstract::Taurine was measured in cerebrospinal fluid by reacting it with fluorescamine to form a fluorescent derivative, followed by separation on a reversed-phase column and fluorometric detection and evaluation. The assay is rapid (17 min) and sensitive to as little as 1 mumol/L. The mean value for 27 cerebrospinal fluid sam...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-08-01 00:00:00
abstract:BACKGROUND:A unique requirement for the molecular diagnosis of mitochondrial DNA (mtDNA) disorders is the ability to detect heteroplasmic mtDNA mutations and to distinguish them from homoplasmic sequence variations before further testing (e.g., sequencing) is performed. We evaluated the potential utility of temporal te...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-08-01 00:00:00
abstract::I describe the automation/mechanization of several areas of sample processing at SmithKline Beecham Clinical Laboratories. By analyzing and implementing new systems for conveyance and sorting of incoming specimens, specimen processing, within-laboratory specimen delivery, specimen storage and retrieval, and client res...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-09-01 00:00:00
abstract::We have devloped an enzyme-linked immunosorbent assay for determining choriomammotropin (human placental lactogen) in serum. Unlabeled hormone competes with choriomammotropin-beta-galactosidase conjugate for antibody bound to polystyrene tubes. The entire assay can be performed in 2.5 h with good precision. The coeffi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-02-01 00:00:00
abstract:BACKGROUND:Standardization of hemoglobin (Hb)A(1c) measurements is a process of considerable interest for quality assurance in diabetes management. To contribute to continuous quality improvement and fulfillment of the requirements for reference measurement procedures according to the standards of the International Org...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.139477
更新日期:2010-05-01 00:00:00
abstract:BACKGROUND:Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS:Blood samples were collected with and withou...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章,多中心研究
doi:
更新日期:2000-06-01 00:00:00
abstract:BACKGROUND:Clinical proteomics presents great promise in biology and medicine because of its potential for improving our understanding of diseases at the molecular level and for detecting disease-related biomarkers for diagnosis, prognosis, and prediction of therapeutic responses. To realize its full potential to impro...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.156034
更新日期:2011-04-01 00:00:00
abstract::We describe an improved procedure for the preparation of plasma or serum for determination of theophylline by reverse phase high-performance liquid chromatography. Quantitative results are available in less than 30 min from receipt of sample. The chromatogram is complete in 8 to 16 min, which includes the use of an in...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-01-01 00:00:00
abstract::We describe a procedure by which surfactant/albumin ratios in bronchoalveolar fluid (BALF) may be quantified with the Abbott Laboratories TDx fluorescence polarization analyzer and fetal lung maturity reagents. Adding albumin to BALF samples shifted the surfactant/albumin ratios to within the analytical range of the m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-07-01 00:00:00
abstract::We have designed a re-usable dialysis cell and a complex dialysis buffer, with which undiluted serum samples can be dialyzed with minimal changes in their serum matrix. Dialysate thyroxin (free T4) is then measured by a sensitive RIA for T4. The range of reportability was 2-128 ng/L, the normal range was 8-27 ng/L, an...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-09-01 00:00:00
abstract:BACKGROUND:C-peptide is a marker of insulin secretion in diabetic patients. We assessed within- and between-laboratory imprecision of C-peptide assays and determined whether serum calibrators with values assigned by mass spectrometry could be used to harmonize C-peptide results. METHODS:We sent 40 different serum samp...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:10.1373/clinchem.2007.101287
更新日期:2008-06-01 00:00:00
abstract::A method for determining platinum in biological materials by flameless atomic absorption spectrometry has been developed for use in pharmacological studies of platinum antitumor compounds. Tissue digests are analyzed in a heated graphite atomizer, with use of background correction and ramp temperature charring. We hav...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-07-01 00:00:00
abstract::Determination of the MB isoenzyme of creatine kinase in patients with acute myocardial infarction may be disturbed by the presence of macro creatine kinase. The relative molecular mass of this form of creatine kinase in human serum is at least threefold that of the ordinary enzyme, and it is more thermostable. Here we...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-01-01 00:00:00
abstract::Apoprotein (apo) C-I, C-II, and C-III were measured in plasma from 35 white American non-diabetic subjects. The mean concentrations (mg/L) in plasma from normolipidemic and hypertriglyceridemic subjects, respectively, were apo C-I, 78 and 311; apo C-II, 37 and 200; and apo C-III, 98 and 529. These concentrations were ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-10-01 00:00:00
abstract::We compared a selection of quantitative immunological methods for prostatic acid phosphatase (PAP) with routine colorimetric assays for total and tartrate-labile acid phosphatase and evaluated their relative clinical merits in the differential diagnosis of prostatic carcinoma. We also assessed a wide range of commerci...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-09-01 00:00:00
abstract::In this simple, quick procedure for determining copper in human serum and urine, the serum and urine specimens were analyzed directly after dilution with a solution of HNO3 and Triton X-100, 1 mL/L each. We calibrated with aqueous standards for quantitation in Zeeman background atomic absorption spectrometry. By modif...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract::We describe a simple and convenient method for processing small amounts of tissue samples for trace-metal measurements by atomic absorption spectrometry, by use of a modified Parr microwave digestion bomb. Digestion proceeds rapidly (less than or equal to 90 s) in a sealed Teflon-lined vessel that eliminates contamina...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-03-01 00:00:00
abstract::We report the results of a laboratory and clinical evaluation of a commercial kit procedure (Immuno Nuclear Corp.) for measuring the mid-region of the parathyrin molecule. The estimated dose at 50% binding averaged 130 pmol/L, and the minimum detectable concentration was 14 pmol/L. The within-assay CV was less than or...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-11-01 00:00:00
abstract::We have studied the influence of triglyceride-rich particles on the analytical bias of apolipoprotein B measurements by various immunoturbidimetric methods. Three commercially available methods grossly overestimate apolipoprotein B in samples with even moderately above-normal triglyceride concentrations. This effect i...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-05-01 00:00:00