Abstract:
:We describe estimation of total cortisol in serum by HPLC. Incorporation of a new technique to totally automate sample preparation decreases costs. The benefits of HPLC ensure that interferences from other steroids are avoided. The method can also be used to estimate concentrations of other glucocorticoids in serum.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Turnell DC,Cooper JD,Green B,Hughes G,Wright DJsubject
Has Abstractpub_date
1988-09-01 00:00:00pages
1816-20issue
9eissn
0009-9147issn
1530-8561journal_volume
34pub_type
杂志文章abstract::Clinicians experience difficulty in correctly interpreting the results of in vitro thyroid function tests in the presence of abnormalities of thyrobinding proteins or when results are borderline. This difficulty has been largely resolved in our laboratory by three innovations. First, the borderline areas for each of t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-10-01 00:00:00
abstract::We report another patient with a circulating alkaline phosphatase/immunoglobulin complex in his blood, and describe a simple method of demonstrating such complexes. On electrophoresis on cellulose acetate, the complex was relatively slow moving and there was no activity in the normal bone/liver isoenzyme region. When ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-10-01 00:00:00
abstract::We describe modifications to two cartridges, those for alkaline phosphatase and creatinine, on an 18-channel SMAC (Sequential Multichannel Analyzer Computerized), which allow all 18 tests to be run with a commonly prediluted sample. This decreases the required sample size and eliminates the problem of fibrin clots in ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-05-01 00:00:00
abstract::A novel noninstrumented technology (ChemTrak AccuMeter) for the quantitative measurement of analytes in biological fluids was reported at the 1990 Oak Ridge Conference (Clin Chem 1990;36:1591-7). This instrument-free technology has been adapted for the quantitative measurement of high-density lipoprotein (HDL). An in ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract::Glucose was measured by the ferricyanide, the Beckman glucose oxidase, and the hexokinase procedures in 228 plasma samples taken during standard oral glucose-tolerance tests in 17 normal subjects and in 21 chemical diabetics. The neocuproine method was also used to measure glucose concentration in 156 samples (78 befo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-12-01 00:00:00
abstract::Serial results from an individual are often obtained using more than one method. Results should be transferable over time and locale. Every method has inherent analytical error, and goals are required to delineate the maximum allowable random (imprecision) and systematic (inaccuracy, bias) errors to facilitate optimal...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1992-11-01 00:00:00
abstract:BACKGROUND:The antiphospholipid syndrome (APS) is an important cause of acquired thromboembolic complications and pregnancy morbidity. Its diagnosis is based on clinical and laboratory criteria, defined by strict guidelines. The original clinical and laboratory criteria for the identification of APS patients were publi...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2009.133678
更新日期:2010-06-01 00:00:00
abstract::Single-strand conformation polymorphism (SSCP) analysis is widely used to prescreen mutations in p53 gene. However, standardization of SSCP to detect p53 mutations has rarely been pursued so far. We have developed complete conditions for a temperature-controlled nonradioactive SSCP for mutation detection in amplified ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-12-01 00:00:00
abstract::Parathyroid hormone-related protein (PTHrP) was measured in plasma by a new immunoradiometric assay (IRMA) from Nichols Institute. The assay is specific for PTHrP and shows excellent parallelism when measuring keratinocyte fluid, samples with high PTHrP content, and PTHrP-supplemented plasma. A precision profile estab...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-03-01 00:00:00
abstract:BACKGROUND:Testing for troponin has important clinical value for patients who present with typical symptoms of acute coronary syndromes (ACS) such as chest pain (CP). Much less is known about the value of troponin testing for patients who present with other symptoms of ACS (anginal equivalent symptoms). METHODS:The ut...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.016311
更新日期:2004-01-01 00:00:00
abstract::Laboratories of the Lipid Research Clinics Program (LRC) maintained the accuracy of their measurements of total cholesterol by using seven pooled serum calibrators supplied by the Centers for Disease Control (CDC). Over the 11-year life of the LRC, each calibrator was prepared in succession and a target value was assi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-04-01 00:00:00
abstract::We describe the influence of autoantibodies that bind creatine kinase BB (CK-BB) on the methods for MB isoenzyme. If these autoantibodies are present in patients' sera, they cause the formation of macro CK type 1 (immunoglobulin-linked CK-BB). In some of these cases they can bind not only endogenous CK-BB but also CK-...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-07-01 00:00:00
abstract:BACKGROUND:Evidence suggests that systemic inflammation may adversely impact HDL function. In this study we sought to evaluate the independent and incremental predictive performance of GlycA-a novel serum inflammatory biomarker that is an aggregate measure of enzymatically glycosylated acute phase proteins-and HDL subc...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.261636
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:To review information on the use of laboratory tests in screening, diagnosis, and monitoring of acute and chronic hepatic injury. DATA SOURCES AND STUDY SELECTION:A MEDLINE search was performed for key words related to hepatic diseases, including acute hepatitis, chronic hepatitis, alcoholic hepatitis, cirrhos...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:2000-12-01 00:00:00
abstract::We report results for adjusted ionized calcium (at pH 7.4) and actual ionized calcium (at actual pH) in capillary blood from 183 patients with disorders of calcium metabolism (primary hyperparathyroidism, secondary hyperparathyroidism of malabsorption, primary hypoparathyroidism, Paget's disease, acromegaly, hypercalc...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-03-01 00:00:00
abstract::Using a high-affinity solid-phase-bound antibody (Ka = 1.2 X 10(11) L/mol), we have standardized a two-step radioimmunoassay for free triiodothyronine (FT3) in serum, based on immunoextraction. The method was validated by comparison with an equilibrium-dialysis procedure (r = 0.96) involving RIA of T3 in the dialysate...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-03-01 00:00:00
abstract::We compared three current methods (immunoinhibition, "Isomune-CK" immunoprecipitation, and the Tandem-E CKMB II immunoenzymometric assay) for determination of creatine kinase (CK; EC 2.7.3.2) isoenzyme MB in serum. Although results inter-correlated well, the immunoinhibition assay gave higher activity values. Atypical...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract:BACKGROUND:We have developed a silicon-based biosensor that generates a visual signal in response to nucleic acid targets. METHODS:In this system, capture oligonucleotide probes are immobilized on the surface of the biosensor. Interaction of the capture probes with a complementary target and a biotinylated detector ol...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-09-01 00:00:00
abstract:BACKGROUND:Few data compare cardiac troponin T (cTnT) and cardiac troponin I (cTnI) in a general population. We sought to evaluate the distribution and association between cTnT, cTnI, and cardiovascular risk factors in a large general population cohort. METHODS:High-sensitivity cTnT and cTnI were measured in serum fro...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.292086
更新日期:2018-11-01 00:00:00
abstract::We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-01-01 00:00:00
abstract::A "sandwich" enzyme immunoassay for ferritin in human serum is described, in which horseradish peroxidase-labeled antibody and a very sensitive chromogen, 2,2'-azino-di(3-ethyl-benzthiazolin-6-sulfonate), are used. The solid phase is polypropylene test tubes treated with glutaraldehyde; immunologic reactions are devel...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-04-01 00:00:00
abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract::To determine when a change in serial measurements of prothrombin time in patients receiving oral anticoagulant therapy (ACT) is a statistically significant biological change necessitating dose adjustment, one must know the size of the "critical difference" in statistical terms (i.e., probabilities). In a cohort of 32 ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-03-01 00:00:00
abstract::We investigated glycosylated hemoglobin S by means of chromatography on Bio-Rex 70. The selected elution conditions were similar to those described by Trivelli et al. (N Engl J Med 284: 353-357, 1971), except for modified ionic strength and accurate temperature control. This enabled us to isolate a minor hemoglobin fr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-04-01 00:00:00
abstract::We have modified an automated measurement system of urinary iodine (UI) and established a sensitive UI assay system by using ultraviolet (UV) digestion. The automated system is sensitive enough to detect concentrations of UI < 0.78 mumol/L (< 10 micrograms/dL) in a small volume of urine (500 microL). Sample throughput...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-04-01 00:00:00
abstract::We report here the evaluation of the Abbott TDx assay with a monoclonal antibody for selectively quantifying cyclosporine (CsA) in whole blood. Over the clinically relevant concentration ranges, results with this assay demonstrated within- and between-run CVs of less than 2.5% and 5%, respectively; sensitivity of 25 m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-11-01 00:00:00
abstract::A monoclonal-antibody-based competitive radioimmunoassay for measuring human protein C is reported. With use of a purified protein C standard, the solid-phase assay was sensitive to less than 80 micrograms of protein C per liter. Intraassay CVs ranged from 5% to 8%; the inter-assay CV was 5.4%. Analytical recovery ave...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-02-01 00:00:00
abstract::A simple computer-based screening technique has been developed for classifying human expired air components into 16 chemical classes, based on empirical formulas. The sort procedure was developed to simplify the screening of the composition of expired air samples by sorting all components into chemical classes and cla...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-08-01 00:00:00
abstract::We describe a highly accurate and precise method for determination of total cholesterol in serum by isotope dilution/mass spectrometry. The method was developed for a Study Group of the Committee on Standards of the American Association for Clinical Chemistry, for use in establishing the accuracy of a candidate refere...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-06-01 00:00:00
abstract::We determined the LD-1/LD-2 isoenzyme ratio in hemolysates of erythrocytes by electrophoresis on cellulose acetate and on agarose. A ratio exceeding 1.0 was found with the former but not the latter. Results were similar for in vitro models of hemolytic disorders. Using cellulose acetate electrophoresis, we determined ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-08-01 00:00:00