Challenges in the diagnosis of the antiphospholipid syndrome.

Abstract:

BACKGROUND:The antiphospholipid syndrome (APS) is an important cause of acquired thromboembolic complications and pregnancy morbidity. Its diagnosis is based on clinical and laboratory criteria, defined by strict guidelines. The original clinical and laboratory criteria for the identification of APS patients were published in 1999, in the so-called Sapporo criteria. In 2006 these criteria were revised, and recently more precise guidelines for analysis of the lupus anticoagulant have been provided. However, several questions related to the diagnosis of APS remain unanswered. CONTENT:In addition to providing a historical perspective, this review covers several challenges in the diagnosis of APS with respect to clinical and laboratory features, while highlighting pathogenic pathways of the syndrome. We discuss ongoing dilemmas in the diagnosis of this complex disease. Although antiphospholipid antibodies are found in association with various clinical manifestations, the older established clinical criteria were not substantively altered in the 2006 update. Several laboratory tests recommended in the latest criteria, including phospholipid-dependent coagulation tests for the detection of the lupus anticoagulant and ELISAs for measuring anticardiolipin and beta2-glycoprotein I antibodies, still show methodological and diagnostic shortcomings. In addition, antiphospholipid antibodies have been described against other antigens, but their clinical role remains uncertain. CONCLUSIONS:Despite updated APS criteria, diagnosis of this syndrome remains challenging. Further research on clinically relevant antibodies and standardization of their detection are needed to improve clinical risk assessment in APS.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Devreese K,Hoylaerts MF

doi

10.1373/clinchem.2009.133678

subject

Has Abstract

pub_date

2010-06-01 00:00:00

pages

930-40

issue

6

eissn

0009-9147

issn

1530-8561

pii

clinchem.2009.133678

journal_volume

56

pub_type

杂志文章,评审
  • Multilayer film analysis for glucose in 1-microL samples of plasma.

    abstract::With the ultramicroanalytical system described here we can measure glucose in 1 microL of plasma or serum. The sample is placed on a dry, multilayer film element (Eastman Kodak), where a colored spot about 3.5 mm in diameter develops. The reflectance of these spots is measured with a reflectance digital matrix photome...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-12-01 00:00:00

  • Isothermal recombinase polymerase amplification assay applied to the detection of group B streptococci in vaginal/anal samples.

    abstract:BACKGROUND:Group B streptococcal infections are the leading cause of sepsis and meningitis in newborns. A rapid and reliable method for the detection of this pathogen at the time of delivery is needed for the early treatment of neonates. Isothermal amplification techniques such as recombinase polymerase amplification h...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.213504

    authors: Daher RK,Stewart G,Boissinot M,Bergeron MG

    更新日期:2014-04-01 00:00:00

  • State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:The recent interest of clinical laboratories in developing serum testosterone assays based on isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) stems from the lack of accuracy of direct immunoassays. In this study, we assessed the accuracy and state of standardization (traceabilit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.105841

    authors: Thienpont LM,Van Uytfanghe K,Blincko S,Ramsay CS,Xie H,Doss RC,Keevil BG,Owen LJ,Rockwood AL,Kushnir MM,Chun KY,Chandler DW,Field HP,Sluss PM

    更新日期:2008-08-01 00:00:00

  • Characterization of a new certified reference material for human cardiac troponin I.

    abstract:BACKGROUND:To address the continuing need for the standardization of clinical human cardiac troponin I (cTnI) assays, NIST, with the assistance of the AACC/IFCC Cardiac Troponin I Standardization Committee, has developed a new certified reference material, Standard Reference Material (SRM) 2921: Human Cardiac Troponin ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051359

    authors: Bunk DM,Welch MJ

    更新日期:2006-02-01 00:00:00

  • Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.

    abstract::We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilson DH,Bogacz JP,Forsythe CM,Turk PJ,Lane TL,Gates RC,Brandt DR

    更新日期:1993-10-01 00:00:00

  • Analytical problems facing the development of electrochemical transducers for in vivo drug monitoring: an overview.

    abstract::Even though significant progress has been made in the development of electrodes for the in vivo detection of catecholamines, oxygen, and various cations, there has been little research on the feasibility of continuously monitoring drugs in whole blood by electrochemical sensing devices. Electroanalytical problems asso...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pinkerton TC,Lawson BL

    更新日期:1982-09-01 00:00:00

  • Assessing quality and functionality of DNA from fresh and archival dried blood spots and recommendations for quality control guidelines.

    abstract:BACKGROUND:Dried blood spots (DBS) are a convenient and inexpensive method for biobanking. Although many countries have established population-based DBS biobanks from neonatal screening programs, the quality and usefulness of DNA from DBS have not been extensively assessed. METHODS:We compared 4 common DNA extraction ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.087510

    authors: Sjöholm MI,Dillner J,Carlson J

    更新日期:2007-08-01 00:00:00

  • Arsenic speciation in human organs following fatal arsenic trioxide poisoning--a case report.

    abstract::The aim of this investigation was to study the distribution of arsenic species in human organs following fatal acute intoxication by arsenic trioxide. The collected autopsy samples of most organs were ground and dried, and the total arsenic was measured by electrothermal atomic absorption spectrometry (ETAAS). The ars...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Benramdane L,Accominotti M,Fanton L,Malicier D,Vallon JJ

    更新日期:1999-02-01 00:00:00

  • New Colorimetric reaction for end-point, continuous-flow, and kinetic measurement of urea.

    abstract::A reaction of urea, o-phthalaldehyde and N-(1-naphthyl)ethylenediamine is described for measurement of urea by manual, continuous-flow, and kinetic methods. The continuous-flow system requires 25 mu-l of sample; 40 samples can be analyzed per hour. The kinetic method requires no enzymes, has no lag phase, and has good...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jung D,Biggs H,Erikson J,Ledyard PU

    更新日期:1975-07-01 00:00:00

  • Modified heparin-Sepharose procedure for determination of plasma lipolytic activities of normolipidemic and hyperlipidemic subjects after injection of heparin.

    abstract::A modified heparin-Sepharose affinity chromatography procedure (Boberg et al., J. Lipid Res. 18:544-547, 1977) was developed to determine two different triglyceride lipase activities in human post-heparin plasma: hepatic triglyceride lipase (I) and lipoprotein lipase (II). With this procedure, lipoproteins were separa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang CS,Bass HB,Downs D,Whitmer RK

    更新日期:1981-05-01 00:00:00

  • A semi-automated fluorometric method for total estrogens in pregnancy urine.

    abstract::We report a continuous-flow fluorometric method for total urinary estrogens that involves the Kober reaction, with extraction of the reaction product into dichloroethane containing trichloroacetic acid as described by Hahnel and Jones [Clin. Chim. Acta 16, 185 (1967)]. The dichloroethane extraction gives greater stabi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frye R,Fong PF,Johnson GF,Rock RC

    更新日期:1977-10-01 00:00:00

  • A systematic approach to materials handling in clinical laboratories.

    abstract::I describe the automation/mechanization of several areas of sample processing at SmithKline Beecham Clinical Laboratories. By analyzing and implementing new systems for conveyance and sorting of incoming specimens, specimen processing, within-laboratory specimen delivery, specimen storage and retrieval, and client res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nabb DP

    更新日期:1990-09-01 00:00:00

  • Evaluation of clinical assays for measuring high-dose methotrexate in plasma.

    abstract::Four routine assays commonly used for monitoring plasma methotrexate (MTX) during high-dose therapy were validated by HPLC as the comparison method. MTX and its main metabolite, 7-hydroxymethotrexate (7-OHMTX), were analyzed by HPLC with postcolumn derivatization and fluorometric detection. About 200 clinical plasma s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Albertioni F,Rask C,Eksborg S,Poulsen JH,Pettersson B,Beck O,Schroeder H,Peterson C

    更新日期:1996-01-01 00:00:00

  • Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement.

    abstract:BACKGROUND:Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.118000

    authors: Campbell DJ,Nussberger J,Stowasser M,Danser AH,Morganti A,Frandsen E,Ménard J

    更新日期:2009-05-01 00:00:00

  • Rate of decrease in serum ethchlorvynol concentrations after extreme overdosage-a case study.

    abstract::Ethchlorvynol is a commonly abused sedative hypnotic. I report here a seven-day study of serum ethchlorvynol concentrations in a patient who had received an extreme overdose. These concentrations were correlated with the patient's response to stimuli. Serum ethchlorvynol concentrations were logarithmically related to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pochopien DJ

    更新日期:1975-06-01 00:00:00

  • Potential use of ketoconazole in a dynamic endocrine test to differentiate between biological outliers and testosterone use by athletes.

    abstract::Determination of the ratio of testosterone to epitestosterone (T/E) in urine is used to detect testosterone administration in athletes, with a ratio > 6 considered as evidence of an offense. We show that administration of ketoconazole, which inhibits testosterone biosynthesis, may be useful for differentiating between...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kicman AT,Oftebro H,Walker C,Norman N,Cowan DA

    更新日期:1993-09-01 00:00:00

  • Rapid, simple, and sensitive immunoagglutination assay with SiO2 particles and quartz crystal microbalance for quantifying Schistosoma japonicum antibodies.

    abstract:BACKGROUND:The resurgence of the parasitic disease schistosomiasis calls for more efficient diagnostic tests. We developed a rapid, simple, portable, and sensitive immunoagglutination assay that uses SiO(2) particles and quartz crystal microbalance (QCM) for quantifying Schistosoma japonicum (Sj) antibodies (SjAb). ME...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.071555

    authors: Wang H,Zhang Y,Yan B,Liu L,Wang S,Shen G,Yu R

    更新日期:2006-11-01 00:00:00

  • Evaluation of nicked human chorionic gonadotropin content in clinical specimens by a specific immunometric assay.

    abstract::We report the development and characterization of an IRMA for the direct measurement of nicked human chorionic gonadotropin (hCGn) in blood and urine. hCGn derived from a reference preparation of hCG used as an immunogen elicits monoclonal antibodies (mAbs) with enhanced recognition of human luteinizing hormone epitop...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kovalevskaya G,Birken S,Kakuma T,Schlatterer J,O'Connor JF

    更新日期:1999-01-01 00:00:00

  • Prognostic value of chromogranin A at admission in critically ill patients: a cohort study in a medical intensive care unit.

    abstract:BACKGROUND:Risk assessments of patients should be based on objective variables, such as biological markers that can be measured routinely. The acute response to stress causes the release of catecholamines from the adrenal medulla accompanied by chromogranin A (CGA). To date, no study has evaluated the prognostic value ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.102442

    authors: Zhang D,Lavaux T,Voegeli AC,Lavigne T,Castelain V,Meyer N,Sapin R,Aunis D,Metz-Boutigue MH,Schneider F

    更新日期:2008-09-01 00:00:00

  • Single-spin density-gradient ultracentrifugation vs gradient gel electrophoresis: two methods for detecting low-density-lipoprotein heterogeneity compared.

    abstract::Single-spin density-gradient ultracentrifugation (DUC) has proven to be a reproducible method for detection of low-density-lipoprotein (LDL) heterogeneity. Recently another method has been described for this: gradient gel electrophoresis (GGE) of serum, a method that might be more suitable for screening. To gain insig...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dormans TP,Swinkels DW,de Graaf J,Hendriks JC,Stalenhoef AF,Demacker PN

    更新日期:1991-06-01 00:00:00

  • Double-monoclonal immunofluorometric assays for pregnancy-associated plasma protein A/proeosinophil major basic protein (PAPP-A/proMBP) complex in first-trimester maternal serum screening for Down syndrome.

    abstract::Four double-monoclonal time-resolved immunofluorometric assays (TrIFMAs) have been developed for the specific determination of pregnancy-associated plasma protein A/proeosinophil major basic protein (PAPP-A/ proMBP) complex in first-trimester maternal serum samples. The assays have a functional sensitivity of < 4 mIU/...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Qin QP,Christiansen M,Oxvig C,Pettersson K,Sottrup-Jensen L,Koch C,Nørgaard-Pedersen B

    更新日期:1997-12-01 00:00:00

  • Laboratory evaluation of the Boehringer Mannheim "Diagnostic M" automated discrete analyzer.

    abstract::We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson CA,Proelss H,Stabler TV

    更新日期:1982-01-01 00:00:00

  • A double-monoclonal immunoenzymometric assay for alpha 1-fetoprotein modified for increased analytical precision.

    abstract::We modified a one-step, two-site, double monoclonal immunoenzymometric assay (Abbott Laboratories) for serum alpha1-fetoprotein (AFP) to increase its sensitivity and improve test precision at the low end. We increased sample size, incubation interval, and reaction time and temperature, and decreased the final reaction...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shahangian S,Fritsche HA Jr,Hughes JI

    更新日期:1987-04-01 00:00:00

  • Diagnostic value of plasma cystatin C as a glomerular filtration marker in decompensated liver cirrhosis.

    abstract:BACKGROUND:Plasma creatinine concentration and calculated creatinine clearance are of limited value as glomerular filtration rate (GFR) markers in patients with decompensated liver cirrhosis. We assessed plasma cystatin C as an indicator of GFR in such patients. METHODS:We studied 36 patients with decompensated liver ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Orlando R,Mussap M,Plebani M,Piccoli P,De Martin S,Floreani M,Padrini R,Palatini P

    更新日期:2002-06-01 00:00:00

  • Precision of sensitivity estimations in diagnostic test evaluations. Power functions for comparisons of sensitivities of two tests.

    abstract::The precision of estimates of the sensitivity of diagnostic tests is evaluated. "Sensitivity" is defined as the fraction of diseased subjects with test values exceeding the 0.975-fractile of the distribution of control values. An estimate of the sensitivity is subject to sample variation because of variation of both c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Linnet K

    更新日期:1985-04-01 00:00:00

  • Reduced bovine hemoglobin solution evaluated for use as a blood gas quality-control material.

    abstract::We evaluated a new commercially available partially purified reduced bovine hemoglobin solution (RBHS) and a new tonometer for use in the quality control of blood gas analyzers. RBHS is manufactured in three different formulations, each corresponding to three different bicarbonate-buffering capacities and concentratio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mahoney JJ,Wong RJ,Van Kessel AL

    更新日期:1993-05-01 00:00:00

  • Flash-heater ethylation of some antiepileptic drugs.

    abstract::We describe a modification of the MacGee method [Anal. Chem. 42, 421 (1970)] for rapid determination of phenytoin (diphenylhydantoin) in plasma by gas-liquid chromatography, in which an ethylaing reagent is used instead of the more common methylating reagents. With this modification, several N-methylated antiepileptic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friel P,Troupin AS

    更新日期:1975-05-01 00:00:00

  • Adjusted ionized calcium (at pH 7.4) and actual ionized calcium (at actual pH) in capillary blood compared for clinical evaluation of patients with disorders of calcium metabolism.

    abstract::We report results for adjusted ionized calcium (at pH 7.4) and actual ionized calcium (at actual pH) in capillary blood from 183 patients with disorders of calcium metabolism (primary hyperparathyroidism, secondary hyperparathyroidism of malabsorption, primary hypoparathyroidism, Paget's disease, acromegaly, hypercalc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thode J,Holmegaard SN,Transbøl I,Fogh-Andersen N,Siggaard-Andersen O

    更新日期:1990-03-01 00:00:00

  • Liquid-chromatographic determination of free and total 3,4-dihydroxyphenylglycol and 3-methoxy-4-hydroxyphenylglycol in urine.

    abstract::We describe the conjoint measurement in urine of the alcoholic catecholamine metabolites 3,4-dihydroxyphenylglycol (DHPG) and 3-methoxy-4-hydroxyphenylglycol (MHPG). The method involves extraction with ethyl acetate and back-extraction into acetic acid (MHPG), followed by adsorption onto alumina (DHPG). The separation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Julien C,Rodriguez C,Sacquet J,Cuisinaud G,Sassard J

    更新日期:1988-05-01 00:00:00

  • Accuracy and precision of breath-alcohol measurements for a random subject in the postabsorptive state.

    abstract::The accuracy of estimates of blood-alcohol concentration based on measurements of breath-alcohol concentration in a randomly selected subject by a random quantitative evidential breath-alcohol analyzer is evaluated with respect to the breath analyzer itself, its calibration, and the biological variables of the subject...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simpson G

    更新日期:1987-02-01 00:00:00