Development and evaluation of a glucose analyzer for a glucose controlled insulin infusion system ((Biostator).

Abstract:

:The Glucose-Controlled Insulin Infusion System (Biostator) is a modular, computerized, feedback control system for dynamic control of blood glucose concentrations in diabetics. This on-line glucose analyzer for use with whole blood utilizes a novel enzyme (glucose oxidase)-membrane configuration and an electrochemical cell to measure the H202 generated. The analyzer exhibits both short- and long-range stability, and instrument response and analyte concentration are linearly related over the full range of clinical interest. The response is fast, accurate, and precise, and permits determination of blood glucose within 2 min from the moment the blood leaves the patient. Correlation studies were completed to show the agreement between the Biostator Glucose Analyzer and the FDA's recommended hexokinase/glucose-6-phosphate dehydrogenase procedure on whole blood (e.g., average per cent recovered for 11 concentrations between 250 and 900 mg/liter was: hexokinase, 95.6%, Biostator Analyzer, 95.9%; bias and SDd, respectively, at low, normal, and high glucose values were: 12 and 41 mg/liter at the 500 mg/liter level; 4 and 52 mg/liter at the 1000 mg/liter level, and 4 and 128 mg/liter at the 4000 mg/liter level). No appreciable interference is observed with above-normal concentrations of bilirubin, uric acid, creatinine, sodium salicylate, or dextran. Platelet adhesion, which tends to decrease the useful life of the membrane, has been significantly decreased.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Fogt EJ,Dodd LM,Jenning EM,Clemens AH

subject

Has Abstract

pub_date

1978-08-01 00:00:00

pages

1366-72

issue

8

eissn

0009-9147

issn

1530-8561

journal_volume

24

pub_type

杂志文章
  • Influence of intermediate-density lipoproteins on the accuracy of the Friedewald formula.

    abstract::Values of low-density lipoprotein (LDL) cholesterol (C) according to the Friedewald formula (Clin Chem 1972;18:499-502) were compared with those obtained by lipoprotein fractionation in 98 healthy subjects (control group), 135 specimens from patients with peripheral vascular and cerebrovascular disease (atheroscleroti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sentí M,Pedro-Botet J,Nogués X,Rubiés-Prat J

    更新日期:1991-08-01 00:00:00

  • Enzyme-linked immunosorbent assay of apolipoprotein B in blood spotted onto filter paper, suitable for neonatal screening.

    abstract::This assay was developed to measure apolipoprotein (apo) B in blood samples spotted onto filter paper. The long-term aim is to detect young families with the dominantly inherited familial hypercholesterolemia, during current neonatal screening programs. The interassay CV was 5.6%, and apo B concentrations correlated c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang XL,Dudman NP,Wilcken DE

    更新日期:1989-06-01 00:00:00

  • Measurement of urinary oxalate and citrate by capillary electrophoresis and indirect ultraviolet absorbance.

    abstract::We describe a method for measuring urinary oxalate and citrate with capillary electrophoresis (CE) and indirect ultraviolet absorbance detection. Sample preparation is minimal, requiring an acidification, brief centrifugation, and dilution. The method is rapid, with oxalate and citrate having mean migration times of 4...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Holmes RP

    更新日期:1995-09-01 00:00:00

  • Mechanized amidolytic technique for determination of factor X and factor-X antigen, and its application to patients being treated with oral anticoagulants.

    abstract::We describe a mechanized chromogenic assay for factor X, the results of which correlate well with those for the one-stage clotting assays for factor X in which it is activated either via the extrinsic pathway by thromboplastin or directly by Russell's viper venom. We purified human factor X and raised monospecific ant...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: van Wijk EM,Kahlé LH,ten Cate JW

    更新日期:1980-06-01 00:00:00

  • Rapid preparation of nucleotides from acid-soluble pools by chromatography on silica, as exemplified with acid extracts of cultured cells.

    abstract::A rapid technique (5-10 min) has been developed for fractionating nucleotides from base and nucleoside contaminants in acid extracts of cells, by adsorption to silica gels. Silica gels (1-mL bed volume) were washed with 5 mL of water then with 5 mL of acetonitrile/water (90/10 by vol). After applying 3-mL samples, adj...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lothrop CD Jr,Uziel M

    更新日期:1980-09-01 00:00:00

  • Extracellular Vesicles Long RNA Sequencing Reveals Abundant mRNA, circRNA, and lncRNA in Human Blood as Potential Biomarkers for Cancer Diagnosis.

    abstract:BACKGROUND:Extracellular vesicles (EVs) contain a rich cargo of different RNA species with specialized functions and clinical applications. However, the landscape and characteristics of extracellular vesicle long RNA (exLR) in human blood remain largely unknown. METHODS:We presented an optimized strategy for exLR sequ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.301291

    authors: Li Y,Zhao J,Yu S,Wang Z,He X,Su Y,Guo T,Sheng H,Chen J,Zheng Q,Li Y,Guo W,Cai X,Shi G,Wu J,Wang L,Wang P,He X,Huang S

    更新日期:2019-06-01 00:00:00

  • Microscale ultrafiltration technique for determining free drug in 50-microL serum samples.

    abstract::This ultrafiltration technique allows determination of free drug in 50 microL of serum. We ultrafiltered sera containing the following drugs--valproic acid (and its major metabolites), phenobarbital, diazepam, indomethacin, phenytoin, furosemide, and chloramphenicol--using both the commercially available micropartitio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wittfoht W,Duwe K,Kuhnz W,Nau H

    更新日期:1984-06-01 00:00:00

  • Association of changes in oxidative and proinflammatory states with changes in vascular function after a lifestyle modification trial among obese children.

    abstract:BACKGROUND:The association of changes in oxidative and proinflammatory states with vascular function after diet and exercise intervention among obese children has not been previously explored. METHODS:In this 6-week diet and exercise intervention study in 35 obese children, age 12 to 18 years, we evaluated the relatio...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2007.089953

    authors: Kelishadi R,Hashemi M,Mohammadifard N,Asgary S,Khavarian N

    更新日期:2008-01-01 00:00:00

  • Application of the clearance concept to hyponatremic and hypernatremic disorders: a phenomenological analysis.

    abstract::The kidney and its response to the antidiuretic hormone (ADH) are the principal protective mechanisms necessary to maintain a normal plasma tonicity (osmolality). Hence, determination of the response of the ADH-renal axis to an abnormal plasma tonicity is an important step to understanding water homeostasis. Determina...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Shoker AS

    更新日期:1994-07-01 00:00:00

  • A new chromogenic amylase method compared with two established methods.

    abstract::We tested a new amylase reagent involving chromogenic substrates (Pantrak, Calbiochem-Behring) for precision, dynamic range, and susceptibility to potential interferences. Two p-nitrophenyl-alpha-maltaosides are used as substrates, which amylase cleaves to shorter-chain p-nitrophenyl maltaosides, the latter then yield...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fenton J,Foery R,Piatt L,Geschwindt K

    更新日期:1982-04-01 00:00:00

  • Modified method for determining carcinoembryonic antigen in the presence of human anti-murine antibodies.

    abstract::The increasing use of monoclonal antibodies (MAbs) for disease diagnosis and therapy has created a class of patients at risk for systematic error in clinical testing due to interference by human anti-murine antibodies (HAMA). HAMA interference is often difficult to detect and can cause either an increase or a decrease...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morrissey NE,Quadri SF,Kinders R,Brigham C,Rose S,Blend MJ

    更新日期:1993-03-01 00:00:00

  • Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

    abstract::We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jiménez A,Arenas J,Santos I,Martínez A

    更新日期:1986-08-01 00:00:00

  • Effect of serum lipids on radioimmunoassays of unconjugated estriol in serum.

    abstract::Controversy regarding the presence of a circadian rhythm in unconjugated estriol in serum during pregnancy led us to study the possibility that the observed rhythms actually are the result of partitioning of estriol into serum lipids when these increase postprandially. Addition of triglycerides to purified estriol sta...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jawad MJ,Wilson EA,Rayburn WF

    更新日期:1981-02-01 00:00:00

  • Radioimmunoassay for arylsulfatase A in urine.

    abstract::Purified arylsulfatase A (EC 3.1.6.1) from human urine was radioiodinated under conditions that caused no significant loss of antigenic activity. We used this labeled arylsulfatase A (specific radioactivity 4-7.5 Ci/g) together with nonlabeled enzyme and rabbit antiserum produced against homogeneous enzyme to develop ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Laidler PM,Ryder KW,Glick MR,Oei TO,Van Etten RL

    更新日期:1985-03-01 00:00:00

  • Fibulin-1 is a marker for arterial extracellular matrix alterations in type 2 diabetes.

    abstract:BACKGROUND:Extracellular matrix alterations are important elements in the arterial changes seen in diabetes, being associated with increased vascular stiffness and the development of cardiovascular diseases. However, no biomarkers for diabetes-related arterial changes have been defined. METHODS:Mammary artery specimen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.162966

    authors: Cangemi C,Skov V,Poulsen MK,Funder J,Twal WO,Gall MA,Hjortdal V,Jespersen ML,Kruse TA,Aagard J,Parving HH,Knudsen S,Høilund-Carlsen PF,Rossing P,Henriksen JE,Argraves WS,Rasmussen LM

    更新日期:2011-11-01 00:00:00

  • Intra- and interindividual biological variation of five analytes used in assessing thyroid function: implications for necessary standards of performance and the interpretation of results.

    abstract::Intra- and interindividual components of biological variation have been determined for total thyroxin (TT4), free thyroxin (FT4), total triiodothyronine (TT3), free triiodothyronine (FT3), and thyrotropin (TSH). Calculated analytical goals (CV, %) for the precision required for optimal patient care are: TT4 less than ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Browning MC,Ford RP,Callaghan SJ,Fraser CG

    更新日期:1986-06-01 00:00:00

  • Measurement of glycosylated hemoglobin on cellulose acetate membranes by mobile affinity electrophoresis.

    abstract::In this method for separating glycosylated from nonglycosylated hemoglobin in blood by electrophoresis on cellulose acetate membranes, we exploit the affinity of low-molecular-mass dextran sulfate for the nonglycosylated fraction, which increases the mobility of the latter relative to that of glycosylated hemoglobin. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ambler J,Janik B,Walker G

    更新日期:1983-02-01 00:00:00

  • Influence of O.C.T. embedding compound on determinations of estrogen and progestin receptors in breast cancer.

    abstract::Estrogen receptor (ER) and progestin receptor (PR) concentrations in tumor biopsies are important predictive indicators of a clinical response to endocrine therapy of breast cancer. To assess interference of O.C.T. (optimum cutting temperature) embedding compound in assays of ER and PR by radioligand binding, we deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pasic R,Djulbegovic B,Wittliff JL

    更新日期:1989-12-01 00:00:00

  • Measuring alveolar lavage fluid surfactant by fluorescence polarization.

    abstract::We describe a procedure by which surfactant/albumin ratios in bronchoalveolar fluid (BALF) may be quantified with the Abbott Laboratories TDx fluorescence polarization analyzer and fetal lung maturity reagents. Adding albumin to BALF samples shifted the surfactant/albumin ratios to within the analytical range of the m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McCarroll NA,Van Lente F

    更新日期:1993-07-01 00:00:00

  • Colorimetry of angiotensin-I converting enzyme activity in serum.

    abstract::This simple, accurate, and reproducible colorimetric method for determining the activity of angiotensin-I converting enzyme is based upon colorimetry of the quinoneimine dye produced from the substrate p-hydroxyhippuryl-L-histidyl-L-leucine by action of this enzyme through the following series of reactions. The enzyme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kasahara Y,Ashihara Y

    更新日期:1981-11-01 00:00:00

  • Myoglobin concentration, creatine kinase activity, and creatine kinase B subunit concentrations in serum during thyroid disease.

    abstract::Changes in values for myoglobin, total creatine kinase (EC 2.7.3.2), and creatine kinase B-subunit in the serum of patients with thyroid disease are compared with values for these during the 24-h after myocardial infarction. Concentrations of all three of these muscle-derived proteins were significantly higher than no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Docherty I,Harrop JS,Hine KR,Hopton MR,Matthews HL,Taylor CJ

    更新日期:1984-01-01 00:00:00

  • Diagnostic Evaluation of a High-Sensitivity Troponin I Point-of-Care Assay.

    abstract:BACKGROUND:Increasing numbers of patients are presenting worldwide to emergency departments with suspected myocardial infarction. The use of point-of-care troponin assays might enable faster decision-making in this high-risk population and reduce the burden on emergency facilities. Here, we evaluate the diagnostic perf...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2019.307405

    authors: Sörensen NA,Neumann JT,Ojeda F,Giannitsis E,Spanuth E,Blankenberg S,Westermann D,Zeller T

    更新日期:2019-12-01 00:00:00

  • Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer.

    abstract::In this new method for determining urinary protein, the reaction is complete within 10 min at 37 degrees C. This method is applicable to automated as well as manual measurements. Protein concentration and absorbance at 600 nm are linearly related throughout a wide range of concentrations, 10 to 16 000 mg/L. However, t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Watanabe N,Kamei S,Ohkubo A,Yamanaka M,Ohsawa S,Makino K,Tokuda K

    更新日期:1986-08-01 00:00:00

  • The use of linear models and matrix least squares in clinical chemistry.

    abstract::We present a unified approach to the use of linear models and matrix least squares with the intention of providing a better understanding of the techniques themselves and of the statistics that arise from these techniques as they are used in clinical chemistry. Emphasis is placed on the importance of appropriate exper...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Deming SN,Morgan SL

    更新日期:1979-06-01 00:00:00

  • Quinidine-induced decrease of intracellular esterase activity in a hepatoma cell line.

    abstract::Using image-analyzing equipment, we measured the effect of quinidine on the activity of naphthol AS-D chloroacetate esterase, alpha-naphthyl butyrate esterase, alpha-naphthyl acetate esterase, and acid phosphatase in individual cells of a human Hep G2 hepatoma cell line. The impact of the drug on the morphology of the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Markovic OT,Young DS,Markovic NS

    更新日期:1988-03-01 00:00:00

  • Enzyme immunoassay for pregnancy-associated plasma protein-A.

    abstract::This enzyme immunoassay procedure for pregnancy-associated plasma protein type A involves a "sandwich"-type system in microtitration plates. One can detect 0.27 mg of the protein per liter of serum, with a between-batch CV of 10.2%, and the antiserum used does not cross react with any of the other placentally derived ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: MacDonald DJ,Mehta HC,Mack DS,Duffy T,Glen AC

    更新日期:1984-11-01 00:00:00

  • Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure.

    abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa287

    authors: Tan ESJ,Chan SP,Liew OW,Chong JPC,Leong GKT,Yeo DPS,Ong HY,Jaufeerally F,Yap J,Sim D,Ng TP,Ling LH,Lam CSP,Richards AM

    更新日期:2021-01-08 00:00:00

  • Kinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.

    abstract::We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-star...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: de Rijke D,Kreutzer HJ

    更新日期:1983-06-01 00:00:00

  • Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.

    abstract::Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garber CC

    更新日期:1981-08-01 00:00:00

  • Lithium determinations evaluated in eight analyzers.

    abstract::We compared five ion-selective electrodes (ISEs; AVL 985S, Baxter Lytening 2Z, Beckman EL-ISE, Ciba-Corning 654 Na/K/Li, and Nova CRT 11) and a colorimetric method (Ektachem) for determination of lithium with flame atomic absorption and atomic emission spectroscopy. We evaluated precision, recovery, interference by dr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sampson M,Ruddel M,Elin RJ