Rapid radiometric assay used to assess lactoferrin in granulocytes.

Abstract:

:We describe a rapid, precise, and sensitive radiometric assay for human lactoferrin. In this typical "sandwich"-type assay, anti-human lactoferrin is adsorbed onto a polystyrene sphere and bound lactoferrin is detected by the subsequent binding of 125I-labeled anti-human lactoferrin. The assay is accurate for lactoferrin concentrations of 5 to 1500 micrograms/L and takes about 2.5 h to complete. The within-assay and interassay variations (CV) are 5% and 13%, respectively. Neither lysozyme nor heparin, substances that form complexes with lactoferrin, interfered with lactoferrin measurement by this method. The assay has been applied to the measurement of lactoferrin in polymorphonuclear leukocytes of both healthy adults and neonates. We found significantly (p less than 0.001) less lactoferrin in the latter, an abnormality that may be related to known functional deficits of polymorphonuclear leukocytes during the newborn period.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Freeman KL,Anderson DC,Hughes B,Buffone GJ

subject

Has Abstract

pub_date

1985-03-01 00:00:00

pages

407-9

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

31

pub_type

杂志文章
  • Improved interassay correlation of digoxin results in patients with and without renal failure by elimination of digoxin-like immunoreactive factors.

    abstract::Use of immunoassays that do not detect endogenous digoxin-like immunoreactive factors (DLIF) in serum significantly improves the between-assay correlation of digoxin results for patients. We investigated five different immunoassay methods (Abbott, Clinical Assays, Corning, Du Pont, and Syva), measuring digoxin by all ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Skogen WF,Rea MR,Valdes R Jr

    更新日期:1987-06-01 00:00:00

  • Beyond diagnostic accuracy: the clinical utility of diagnostic tests.

    abstract::Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical performance and diagnost...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2012.182576

    authors: Bossuyt PM,Reitsma JB,Linnet K,Moons KG

    更新日期:2012-12-01 00:00:00

  • Effect of daylight on the reaction of thiols with Ellman's reagent, 5,5'-dithiobis(2-nitrobenzoic acid).

    abstract::The reaction of 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB, Ellman's reagent) with thiols is sensitive to daylight, in particular to ultraviolet radiation at wavelengths around 325 nm. Exposure to light at the absorbance maximum of the yellow product (the thionitrobenzoate ion) at 410 nm had no effect on the reaction. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Walmsley TA,Abernethy MH,Fitzgerald HP

    更新日期:1987-10-01 00:00:00

  • Polymorphisms within the protein tyrosine phosphatase 1B (PTPN1) gene promoter: functional characterization and association with type 2 diabetes and related metabolic traits.

    abstract:BACKGROUND:Protein tyrosine phosphatase 1B (PTPN1) dephosphorylates insulin receptors and attenuates insulin signaling. Polymorphisms in the coding sequence of PTPN1 have been variably associated with type 2 diabetes (T2D). We hypothesized that variations within the PTPN1 promoter might contribute to the development of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.088146

    authors: Meshkani R,Taghikhani M,Al-Kateb H,Larijani B,Khatami S,Sidiropoulos GK,Hegele RA,Adeli K

    更新日期:2007-09-01 00:00:00

  • Microassay of amiodarone and desethylamiodarone in serum by capillary electrophoresis with head-column field-amplified sample stacking.

    abstract::Binary-system capillary electrophoresis (CE) with head-column field-amplified sample stacking permits determination of amiodarone and desethylamiodarone in 20-microL serum samples. The assay is characterized by a detection limit for both compounds of 80 nmol/L and by excellent linear response over the recommended ther...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Zhang CX,Aebi Y,Thormann W

    更新日期:1996-11-01 00:00:00

  • Genetic variants in the fibroblast growth factor pathway as potential markers of ovarian cancer risk, therapeutic response, and clinical outcome.

    abstract:BACKGROUND:The fibroblast growth factor (FGF) and FGF receptor (FGFR) axis plays a critical role in tumorigenesis, but little is known of its influence in ovarian cancer. We sought to determine the association of genetic variants in the FGF pathway with risk, therapeutic response, and survival of patients with ovarian ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.211490

    authors: Meng QH,Xu E,Hildebrandt MA,Liang D,Lu K,Ye Y,Wagar EA,Wu X

    更新日期:2014-01-01 00:00:00

  • Enzyme-linked immunosorbent assay for urinary albumin at low concentrations.

    abstract::We describe an enzyme-linked immunosorbent assay (ELISA) for urinary albumin. It requires only commercially available reagents, can detect as little as 16 micrograms of albumin per liter, and analytical recovery ranges from 92 to 116%. The assay is simple, rapid, and inexpensive. Albumin excretion was 6.2 (SD 4.1) mg/...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Krämer BK,Jesse U,Ress KM,Schmülling RM,Risler T

    更新日期:1987-04-01 00:00:00

  • Microassay for nuclear binding of steroid receptors with use of intact cells from small samples of avian and human tissue.

    abstract::A micro version of a nuclear binding assay to assess the biological activity of receptors for steroid hormones was developed for application to small (needle) biopsies of human tumors for the purpose of predicting responses to steroid therapy. This easier assay requires 10-fold less tissue than the original nuclear bi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colvard DS,Jankus WR,Berg NJ,Graham ML 2nd,Jiang NS,Ingle JN,Spelsberg TC

    更新日期:1988-02-01 00:00:00

  • On the use and computation of likelihood ratios in clinical chemistry.

    abstract::The clinical relevance of likelihood ratios (L-values) for revising the physician's diagnostic probabilities has been recognized. However, the calculation of L-values, particularly in the case of quantitative or mixed quantitative-binary test results, raises problems that have not yet been addressed. Based on a very g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Albert A

    更新日期:1982-05-01 00:00:00

  • Type A viral hepatitis: epidemiology, diagnosis, and prevention.

    abstract::Hepatitis A virus (HAV) infection occurs worldwide and is an important cause of acute viral hepatitis in the US. In this review, I cover the epidemiology, course of infection, clinical manifestations, serological responses, and prevention of this infection. Although most patients completely recover from this disease, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Lemon SM

    更新日期:1997-08-01 00:00:00

  • Meaning of serum free-thyroxin values in nonthyroidal illnesses: seven methods compared.

    abstract::Serum free thyroxin (FT4) was determined in 40 patients with various nonthyroidal illnesses. We studied seven methods: (1) a free thyroxin index calculated from total T4 and triiodothyronine resin uptake; (2) a free T4 index determined by enzyme inhibitor assays (Abbott's "Tetrazyme" and "Thyrozyme"); (3) a free T4 in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chan DW,Waud JM,Taylor E,Stem J,Drew H,Oropeza M,Sucupira MS

    更新日期:1983-12-01 00:00:00

  • Free triiodothyronine and free thyroxin in sera of pregnant women and subjects with congenitally increased or decreased thyroxin-binding globulin.

    abstract::Concentrations of free thyroxin (T4) and free triiodothyronine (T3) were measured in sera from pregnant women, in subjects with congenitally increased or decreased thyroxin-binding globulin (TBG), and in euthyroid controls. Measured free hormone concentrations were compared with calculated values for free hormone deri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Franklyn JA,Sheppard MC,Ramsden DB,Hoffenberg R

    更新日期:1983-08-01 00:00:00

  • Is the thrombopoietin assay useful for differential diagnosis of thrombocytopenia? Analysis of a cohort of 160 patients with thrombocytopenia and defined platelet life span.

    abstract:BACKGROUND:Thrombopoietin (TPO), the major hormone controlling platelet production, has been measured in thrombocytopenias with discordant results. The aim of our work was to assess the value of the TPO assay for differential diagnosis of thrombocytopenias in a large cohort of patients classified according to the resul...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gouin-Thibault I,Cassinat B,Chomienne C,Rain JD,Najean Y,Schlageter MH

    更新日期:2001-09-01 00:00:00

  • Urinary excretion of some proteins and enzymes during normal pregnancy.

    abstract::Total protein (TP), albumin (Alb), transferrin (TRF), retinol-binding protein (RPB), N-acetyl-beta-glucosaminidase (NAG), alanine aminopeptidase (AAP), gamma-glutamyltransferase (GGT), and creatinine (Cr) were measured in random (untimed) urine samples from 29 nonpregnant women and from pregnant subjects (11 in the fi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cheung CK,Lao T,Swaminathan R

    更新日期:1989-09-01 00:00:00

  • Collection of blood on filter paper for measurement of glycated hemoglobin by affinity chromatography.

    abstract::We present data on a filter-paper collection and assay method for measurement of glycated hemoglobin (gHb). Onto filter paper dipped into a solution of glucose oxidase (EC 1.1.3.4) and allowed to dry, approximately 20 microL of capillary blood was spotted. For analysis, we eluted the dried blood spot from the paper by...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Little RR,McKenzie EM,Wiedmeyer HM,England JD,Goldstein DE

    更新日期:1986-05-01 00:00:00

  • Five creatine kinase isoenzymes in serum of a patient with severe heart disease.

    abstract::Abnormal creatine kinase (CK) isoenzyme patterns were observed in the serum of a 64-year-old woman with severe heart disease. Agarose electrophoresis revealed the presence of all the usual CK isoenzymes (MM, MB, and BB) plus an extra band between MM and MB. Total serum CK activity was within the normal range. Within 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Csako G,Papadopoulos NM,Jett GK,McIntosh CL

    更新日期:1982-10-01 00:00:00

  • Detection of hemoglobin-based oxygen carriers in human serum for doping analysis: confirmation by size-exclusion HPLC.

    abstract:BACKGROUND:Hemoglobin-based oxygen carriers (HBOCs) are being developed as potential substitutes for the oxygen-carrying functions of erythrocytes, but athletes may obtain and experiment with HBOCs as an illicit means of enhancing oxygen transport. An electrophoretic technique has been developed to screen for the prese...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026591

    authors: Varlet-Marie E,Ashenden M,Lasne F,Sicart MT,Marion B,de Ceaurriz J,Audran M

    更新日期:2004-04-01 00:00:00

  • Enzyme-linked immunosorbent assay of retinol-binding protein in serum and urine.

    abstract::This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lucertini S,Valcavi P,Mutti A,Franchini I

    更新日期:1984-01-01 00:00:00

  • Automated measurement of alpha-amylase isoenzymes with 6(3)-deoxymaltotriose as selective amylase inhibitor.

    abstract::We developed an automated method for measurement of alpha-amylase isoenzymes in serum by a single kinetic assay (SKA) and a double kinetic assay (DKA) with 2-chloro-4-nitrophenyl-6(5)-azido-6(5)-deoxy-beta-maltopentaoside as a substrate and 6(3)-deoxymaltotriose (DOG3) as a novel selective amylase inhibitor. DOG3 show...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Uchida R,Tokutake S,Motoyama Y,Hosoi K,Yamaji N

    更新日期:1995-04-01 00:00:00

  • A search for the best buffer to use in assaying human lactate dehydrogenase with the lactate-to-pyruvate reaction.

    abstract::Highly purified human lactate dehydrogenases I and V were assayed in 17 different buffers, at a variety of reaction pH's. Diethanolamine and 2-amino-2-methyl-1,3-propanediol provided the best measurements of the enzyme, assayed lactate-to-pyruvate. However, the commercial preparation of 2-amino-2-methyl-1,3-propanedio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buhl SN,Jackson KY,Lubinski R,Vanderlinde RE

    更新日期:1976-11-01 00:00:00

  • Direct solid-phase time-resolved immunofluorometric assay of cortisol in serum.

    abstract::A dissociation-enhanced lanthanide fluoroimmunoassay of serum cortisol based on time-resolved fluorescence is described. The assay is a direct assay, where cortisol immobilized on the wall of a microtiter-strip well competes with cortisol in the sample for the europium-labeled polyclonal antibody. The amount of bound ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Eskola JU,Näntö V,Meurling L,Lövgren TN

    更新日期:1985-10-01 00:00:00

  • Determinants of Vascular Age: An Epidemiological Perspective.

    abstract:BACKGROUND:Vascular age is an emerging health indicator and predictor of end-organ damage to the heart, brain, and kidney. Although there have been many review publications concerning risk factors for vascular aging, most include cross-sectional epidemiological studies, limiting inferences about temporality. There is a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2018.287623

    authors: Kucharska-Newton AM,Stoner L,Meyer ML

    更新日期:2019-01-01 00:00:00

  • Endothelial nitric oxide synthase gene polymorphisms and risk of coronary artery disease.

    abstract:BACKGROUND:Endothelial nitric oxide synthase (eNOS) could be a candidate gene for coronary artery disease (CAD). This study investigated the relationship of the eNOS Glu(298)-->Asp and T(786)-->C polymorphisms with the presence and severity of CAD in the Italian population. METHODS:We enrolled 415 unrelated individual...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.3.389

    authors: Colombo MG,Paradossi U,Andreassi MG,Botto N,Manfredi S,Masetti S,Biagini A,Clerico A

    更新日期:2003-03-01 00:00:00

  • Use of proximity ligation to screen for inhibitors of interactions between vascular endothelial growth factor A and its receptors.

    abstract:BACKGROUND:Improved methods are required to screen drug candidates for their influences on protein interactions. There is also a compelling need for miniaturization of screening assays, with attendant reductions in reagent consumption and assay costs. METHODS:We used sensitive, miniaturized proximity ligation assays (...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.099424

    authors: Gustafsdottir SM,Wennström S,Fredriksson S,Schallmeiner E,Hamilton AD,Sebti SM,Landegren U

    更新日期:2008-07-01 00:00:00

  • Measurement of thyroglobulin by liquid chromatography-tandem mass spectrometry in serum and plasma in the presence of antithyroglobulin autoantibodies.

    abstract:BACKGROUND:Measurement of serum thyroglobulin (Tg) is used to monitor patients after treatment for differentiated thyroid carcinoma (TC). Difficulty in using Tg as a biomarker of the recurrence of TC in many patients stems from the presence of endogenous anti-Tg autoantibodies (Tg-AAbs), which can interfere with immuno...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.195594

    authors: Kushnir MM,Rockwood AL,Roberts WL,Abraham D,Hoofnagle AN,Meikle AW

    更新日期:2013-06-01 00:00:00

  • Immunoenzymometric determination of trypsin/alpha 1-protease inhibitor complex in plasma of rats with experimental pancreatitis.

    abstract::The currently available radioimmunoassays of trypsin measure total immunoreactive trypsin (EC 3.1.1.7), which includes both trypsinogen and alpha 1-protease inhibitor-bound trypsin. Hitherto, the only way to differentiate these two forms of trypsin has been to fractionate them on a gel-filtration column. We describe h...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fletcher TS,Tsukamoto H,Largman C

    更新日期:1986-09-01 00:00:00

  • Mass concentration and activity concentration of creatine kinase isoenzyme MB compared in serum after acute myocardial infarction.

    abstract::We compared three current methods (immunoinhibition, "Isomune-CK" immunoprecipitation, and the Tandem-E CKMB II immunoenzymometric assay) for determination of creatine kinase (CK; EC 2.7.3.2) isoenzyme MB in serum. Although results inter-correlated well, the immunoinhibition assay gave higher activity values. Atypical...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delanghe JR,De Mol AM,De Buyzere ML,De Scheerder IK,Wieme RJ

    更新日期:1990-01-01 00:00:00

  • Comparability of results by simplified methods for measuring serum lipoprotein cholesterol in a pediatric population.

    abstract::We compared serum lipoprotein cholesterol concentrations in a randomly selected subsample (n = 406) population of children (ages 5 to 17 years), as measured by the heparin-Ca2+ and the heparin-Mn2+ precipitation methods. Statistical analysis showed significant differences between results by these methods, especially i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Srinivasan SR,Foster TA,Berenson GS

    更新日期:1980-10-01 00:00:00

  • Discontinuation of the bleeding time test without detectable adverse clinical impact.

    abstract:BACKGROUND:The bleeding time (BT) test predicts a higher bleeding complication rate in populations at risk for inherited or acquired platelet dysfunction, but it is of limited assistance in evaluating individual patients. There are no reports of clinical outcomes after discontinuation of the BT test. METHODS:Interview...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lehman CM,Blaylock RC,Alexander DP,Rodgers GM

    更新日期:2001-01-01 00:00:00

  • Circulating epithelial cells in patients with benign colon diseases.

    abstract:BACKGROUND:Detection of circulating tumor cells (CTCs) in the peripheral blood is a rapidly developing research field with clear clinical implications for the staging and monitoring of cancer patients. Current CTC assays, including the US Food and Drug Administration-cleared CellSearch® system, typically use markers [e...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.175570

    authors: Pantel K,Denève E,Nocca D,Coffy A,Vendrell JP,Maudelonde T,Riethdorf S,Alix-Panabières C

    更新日期:2012-05-01 00:00:00