Electrophoretic separation of high-density lipoprotein choelsterol evaluated and compared with the modified lipid research clinic procedure.

Abstract:

:We evaluated a new agarose-gel-electrophoretic procedure (Corning) (I) for separating and quantitating of high-density lipoprotein cholesterol (HDLC), comparing it with the modified Lipid Research Clinics (LRC) procedure (heparin 183 kilounits/L, MnCl2 92 mmol/L) (II). Method I was insensitive to an HDLC concentration of 50 mg/L, but gave a linear dose-response curve between 130 and 1200 mg/L. Method II is sensitive to 50 mg/L and linear from 50--1200 mg/L. The within-plate CV for the Corning method varied from 26.2% for an HDLC of 168 mg/L to 6.8% for 580 mg/L. Within-day between-plate CV for the Corning method ranged from 22.1% at 155 mg/L to 8.0% at 651 mg/L, compared to 3.0 and 0.8% for the modified LRC procedure. Between-day CV for method I was 20, 12.6, 4.3, and 3.5% for HDLC concentrations of 175, 435, 542, and 678 mg/L, respectively; for method II it was 14, 5, 3.5, and 2.6%, respectively. Analysis of HDLC in 100 patients by both procedures showed mean HDLC values to be significantly lower (mean + SD, 27.8 +/- 1.7 mg/L; p less than 0.001) by method I. In 46 patients with HDLC less than 450 mg/L, this difference was accentuated (mean + SD = 40.5 +/- 2.6 mg/L) and clinically significant. Electrophoretic methods offer a promising further alternative method for HDLC separation and quantitation, but the negative bias, present limited sensitivity, and lack of precision at less than 450 mg/L indicate that they are not yet optimal for routine clinical use for patients with values less than 450 mg/L.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Stein EA,McNeely S,Steiner P

subject

Has Abstract

pub_date

1979-11-01 00:00:00

pages

1934-8

issue

11

eissn

0009-9147

issn

1530-8561

journal_volume

25

pub_type

杂志文章
  • Calorimetry of cholinesterase activity in serum.

    abstract::Cholinesterase activity in human serum was measured calorimetrically and compared to values obtained with the spectrophotometric method of Rappaport et al. [Clin. Chim. Acta 4, 227 (1959)]. The response of the calorimeter upon mixing serum with acetylcholine corresponded to the cholinesterase activity of the serum, th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: O'Farrell HK,Chattopadhyay SK,Brown HD

    更新日期:1977-10-01 00:00:00

  • Simplified radioimmunoassay of urinary drugs of abuse adsorbed on ion-exchange papers.

    abstract::A convenient screening procedure for presence of drugs of abuse in urine consists of two steps: adsorption of the drugs from urine onto a paper loaded with cation-exchange resin and detection of the adsorbed drugs by direct radioimmunoassay. The first step can be performed in the field, the second in a central laborat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Alexander GJ,Machiz S

    更新日期:1977-10-01 00:00:00

  • A kinetic standard for precise calibration of spectrophotometer cell temperature.

    abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adams PA,Berman MC

    更新日期:1981-05-01 00:00:00

  • Use of myeloperoxidase for risk stratification in acute heart failure.

    abstract:BACKGROUND:Myeloperoxidase (MPO) is a biomarker of inflammation and oxidative stress produced by neutrophils, monocytes, and endothelial cells. Concentrations of MPO predict mortality in patients with chronic heart failure. This study sought to investigate the diagnostic accuracy and prognostic value of MPO in patients...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.142257

    authors: Reichlin T,Socrates T,Egli P,Potocki M,Breidthardt T,Arenja N,Meissner J,Noveanu M,Reiter M,Twerenbold R,Schaub N,Buser A,Mueller C

    更新日期:2010-06-01 00:00:00

  • Effects on radioimmunoassay of digoxin of varying incubation periods for antigen---antibody reaction and varying periods of absorption by dextran-coated charcoal.

    abstract::In radioimmunoassay of digoxin by the dextran-coated charcoal method, duration of the incubation period for the antigen-antibody reaction and time allowed for dextran-coated charcoal to absorb the free antigen are critical factors. We compared effects of prolonged periods of absorption on results obtained with five co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kuno-Sakai H,Sakai H

    更新日期:1975-02-01 00:00:00

  • Serum-constituents analyses: effect of duration and temperature of storage of clotted blood.

    abstract::We studied the effects on 25 analytes of duration of contact of serum with non-anticoagulated blood and of temperature. Serum was separated after blood was allowed to stand, for 0, 2, 4, 6, 8, 24, or 48 h at 4, 23, or 30 degrees C. Results obtained for bilirubin, albumin, zinc sulfate turbidity, thymol turbidity, chol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ono T,Kitaguchi K,Takehara M,Shiiba M,Hayami K

    更新日期:1981-01-01 00:00:00

  • Reversible myocardial ischemic injury is not associated with increased creatine kinase activity in plasma.

    abstract::Creatine kinase (CK) isoenzymes MM, MB, and BB are located primarily in the cell cytosol, and increased CKMB in plasma is the hallmark of myocardial infarction. However, whether CK is released with reversible ischemic injury remains controversial. Here, we assessed plasma CK activity--cytosolic and mitochondrial CK--i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ishikawa Y,Saffitz JE,Mealman TL,Grace AM,Roberts R

    更新日期:1997-03-01 00:00:00

  • Factors behind the increase in cardiovascular mortality in Russia: apolipoprotein AI and B distribution in the Arkhangelsk study 2000.

    abstract:BACKGROUND:Cardiovascular mortality is markedly higher in Russia than in Western Europe and the US. Little is known about indicators of atherosclerotic risk in the Russian population. To our knowledge, this is the first study of apolipoprotein (apo) AI and B in Russia based on the WHO-IFCC standard. METHODS:We measure...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.023853

    authors: Averina M,Nilssen O,Brenn T,Brox J,Arkhipovsky VL,Kalinin AG

    更新日期:2004-02-01 00:00:00

  • Substrate-leash amplification with ribonuclease S-peptide and S-protein.

    abstract::The S-peptide and S-protein fragments of ribonuclease S (RNase S, no EC no. assigned) have been immobilized onto separate Sepharose gels via a "leash" of polycytidylic acid substrate. Each of these gels releases its RNase fragment when treated with the complementary enzyme fragment or with RNase A (EC 3.1.27.5), and t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ehrat M,Cecchini DJ,Giese RW

    更新日期:1986-09-01 00:00:00

  • Analysis for indole compounds in urine by high-performance liquid chromatography with fluorometric detection.

    abstract::We describe a chromatographic system involving a high-performance chemically-bonded reverse-phase column and fluorescence detection for measurement of indoles in urine. We controlled retention and selectivity by optimizing the methanol content and pH of the mobile phase. Six reference indoles were separated in less th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Graffeo AP,Karger BL

    更新日期:1976-02-01 00:00:00

  • Fluorometric assay for phospholipase A2 in serum.

    abstract::In this fluorometric assay for phospholipase A2 (EC 3.1.1.4) in serum we use the fluorescent phospholipid analog 1-octacosanyl-2-(pyren-1-yl)hexanoyl-sn-glycero-3-phosphatid yl monomethyl ester as substrate. The optimized conditions are: 28 mumol of the substrate per liter of Tris buffer (20 mmol/L, pH 7.4). The hydro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thuren T,Virtanen JA,Lalla M,Kinnunen PK

    更新日期:1985-05-01 00:00:00

  • Inadequate hemolysis of erythrocytes on reagent strips at low pH causes false-negative readings.

    abstract::Patients' urines gave an unexpectedly high percentage of false-negative results for erythrocytes on a reagent strip, even when the test field for ascorbic acid indicated that none of this substance was present to inhibit the test reaction. By adding known amounts of erythrocytes to normal urines, we found that this ph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levin K,Engström I

    更新日期:1984-11-01 00:00:00

  • Minimal disease detection and confirmation in hematologic malignancies: combining cell sorting with clonality profiling.

    abstract:BACKGROUND:In this study we demonstrate the technical application of flow cytometry and cell sorting combined with gene-rearrangement clonality profiling to detect and confirm minimal disease in 2 leukemia and 2 lymphoma cases. METHODS:Specimens with low percentages (0.05%-5%) of abnormal lymphoid populations were ide...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.061259

    authors: Zehentner BK,Fritschle W,Stelzer T,Ghirardelli KM,Hunter K,Wentzel C,Bennington R,Hansen CL,Myerson D,Kalnoski M,Wells DA,Loken MR

    更新日期:2006-03-01 00:00:00

  • Semi-solid surface fluorometric analysis of glucose.

    abstract::We describe an enzymatic fluorometric method for determining glucose concentrations in blood samples by analysis on a semi-solid surface (silicone-rubber pads). The method is an adaptation of existing spectrophotometric procedures based on the sequential coupling reactions with glucose-6-phosphate dehydrogenase and NA...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kiang SW,Kuan JW,Guilbault GG

    更新日期:1975-11-01 00:00:00

  • Prognostic Utility of Galectin-3 for Recurrent Cardiovascular Events During Long-term Follow-up in Patients with Stable Coronary Heart Disease: Results of the KAROLA Study.

    abstract:BACKGROUND:Galectin-3 has emerged as a potential useful novel biomarker for heart failure and cardiovascular disease (CVD). However, it remains unclear whether galectin-3 is associated with recurrent cardiovascular events during long-term follow-up of patients with stable coronary heart disease (CHD) after adjustment f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.257550

    authors: Jansen H,Koenig W,Jaensch A,Mons U,Breitling LP,Scharnagl H,Stojakovic T,Schunkert H,Brenner H,Rothenbacher D

    更新日期:2016-10-01 00:00:00

  • Laboratory values in fit aging individuals--sexagenarians through centenarians.

    abstract::We determined approximately 15,000 laboratory values in 236 individuals between the ages of 60 and 90 y, 22 individuals between 90 and 99 y, and 69 individuals greater than or equal to 100 y, and compared these with values in young adults. We tested 47 different analytes in the 60-90-y group and 93 analytes in the gre...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tietz NW,Shuey DF,Wekstein DR

    更新日期:1992-06-01 00:00:00

  • Serum ionized calcium and corrected total calcium in borderline hyperparathyroidism.

    abstract::We studied 25 borderline-hyperparathyroidism patients whose total serum calcium concentration was within normal limits (reference range: 2.25--2.75 mmol/liter) but whose concentrations of serum ionized calcium were above normal (reference range: 1.03--1.23 mmol/liter). Their hyperparathyroidism was histopathologically...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Larsson L,Ohman S

    更新日期:1978-11-01 00:00:00

  • Sandwich ELISA Using a Mouse/Human Chimeric CSLEX-1 Antibody.

    abstract:BACKGROUND:An assay using a mouse antisialyl Lewis X (sLeX) antibody (CSLEX-1) is used clinically for screening and monitoring patients with breast cancer in Japan. However, the IgM isoform of CSLEX-1 is not preferred for the assay because the bulkiness of IgM generally causes poor accessibility to the antigen. To solv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.260968

    authors: Yamashita J,Kobayashi I,Tatematsu K,Sezutsu H,Noda K,Ishihara H

    更新日期:2016-11-01 00:00:00

  • Total urinary hydroxyproline determined with rapid and simple high-performance liquid chromatography.

    abstract::A precolumn derivatization method was optimized for rapid and specific analysis of total urinary hydroxyproline by HPLC. After an overnight hydrolysis, urine samples dried and reconstituted with the internal standard cysteic acid (in sodium hydrogen carbonate, pH 9.3) were derivatized with N,N-diethyl-2,4-dinitro-5-fl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Paroni R,De Vecchi E,Fermo I,Arcelloni C,Diomede L,Magni F,Bonini PA

    更新日期:1992-03-01 00:00:00

  • Use of cardiac troponin I to diagnose perioperative myocardial infarction in coronary artery bypass grafting.

    abstract::Cardiac troponin I (cTnI) is a regulatory protein unique to myocardium. We used a cardiospecific 30-min ELISA to measure cTnI in EDTA-plasma samples serially drawn from 28 patients before and after coronary artery bypass grafting (CABG)--26 elective and 2 salvage cases. The cTnI increase in 22 of the elective CABG pat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mair J,Larue C,Mair P,Balogh D,Calzolari C,Puschendorf B

    更新日期:1994-11-01 00:00:00

  • Targeted massively parallel sequencing of maternal plasma DNA permits efficient and unbiased detection of fetal alleles.

    abstract:BACKGROUND:Massively parallel sequencing has recently been used in noninvasive prenatal diagnosis. The current costs of this technology are still relatively expensive, however, and sample throughput is still relatively low when it is used as a molecular diagnostic tool. Rather than nonselectively sequencing the genome,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.154336

    authors: Liao GJ,Lun FM,Zheng YW,Chan KC,Leung TY,Lau TK,Chiu RW,Lo YM

    更新日期:2011-01-01 00:00:00

  • Liquid-chromatographic separation of urinary 5-hydroxy-3-indoleacetic acid, with measurement at 254 nm.

    abstract::A "high-performance" liquid-chromatographic procedure for 5-hydroxy-3-indoleacetic acid is described and compared with a colorimetric method in which 1-nitroso-2-naphthol is used. The analyte and an internal standard, p-nitrobenzoic acid, were extracted into diethyl ether from urine at pH 4.0 (acidified with HCl) to w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Draganac PS,Steindel SJ,Trawick WG

    更新日期:1980-06-01 00:00:00

  • Lipoprotein(a) and cardiovascular disease in ethnic Chinese: the Chin-Shan Community Cardiovascular Cohort Study.

    abstract:BACKGROUND:Little is known about lipoprotein(a) [Lp(a)] as a predictor of vascular events among ethnic Chinese. We prospectively investigated the association of Lp(a) with cardiovascular disease and all-cause death in a community-based cohort. METHODS:We conducted a community-based prospective cohort study of 3484 par...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.090969

    authors: Chien KL,Hsu HC,Su TC,Sung FC,Chen MF,Lee YT

    更新日期:2008-02-01 00:00:00

  • Glucocorticoid receptors in normal leukocytes: effects of age, gender, season, and plasma cortisol concentrations.

    abstract::We measured glucocorticoid receptors (GR) in mononuclear leukocytes (MNL) isolated from peripheral blood of 145 apparently healthy volunteers (86 men and 59 women). An age-related decrease in the number of GR was suggested between subjects younger than 20 years and elderly subjects; there was no apparent seasonal vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tanaka H,Akama H,Ichikawa Y,Homma M,Oshima H

    更新日期:1991-10-01 00:00:00

  • Newborn screening for cystic fibrosis by use of a multiplex immunoassay.

    abstract:BACKGROUND:Since its beginnings, newborn screening for cystic fibrosis (CF) using an assay for immunoreactive trypsinogen (IRT) has been plagued by a high rate of false-positive results (screen positive, diagnosis negative), despite attempts to reduce this rate by use of altered cutoffs and second-tier DNA testing. IRT...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.132480

    authors: Lindau-Shepard BA,Pass KA

    更新日期:2010-03-01 00:00:00

  • Standardization with synthetic 22-kDa monomer human growth hormone reduces discrepancies between two monoclonal immunoradiometric assay kits.

    abstract::Discrepancies among different methods for assaying human growth hormone have been described in various studies. The two major sources of discordant results are the heterogeneity of the antibodies and the different standardization bases used by the assay manufacturers. We propose standardizing assays with 22-kDa biosyn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Banfi G,Marinelli M,Pontillo M,Bonini P

    更新日期:1992-10-01 00:00:00

  • Novel application of streptavidin-hapten derivatives as protein-tracer conjugate in competitive-type immunoassays involving biotinylated detection probes.

    abstract::To investigate the use of streptavidin-hapten derivatives as potential protein-tracer conjugates for competitive-type immunoassays, we labeled streptavidin with cortisol and compared biotin-binding activity of the conjugates with that of unlabeled streptavidin. In this model system, streptavidin labeled with one to ap...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Khosravi MJ,Morton RC

    更新日期:1991-01-01 00:00:00

  • Proenzyme forms of prostate-specific antigen in serum improve the detection of prostate cancer.

    abstract:INTRODUCTION:Pro or precursor forms of prostate-specific antigen (PSA) have emerged as potentially important diagnostic serum markers for prostate cancer detection. Immunoassays were developed to measure specific proPSA forms containing propeptides of 2, 4, and 7 amino acids [(-2)proPSA, (-4)proPSA, and (-7)proPSA, res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026823

    authors: Mikolajczyk SD,Catalona WJ,Evans CL,Linton HJ,Millar LS,Marker KM,Katir D,Amirkhan A,Rittenhouse HG

    更新日期:2004-06-01 00:00:00

  • Immunoassay of low concentrations of albumin in urine by latex particle counting.

    abstract::We describe here a nonisotopic immunoassay, based on particle-counting technology, for the determination of urinary albumin. The assay takes only 35 min and has been fully automated on the IMPACT (Acade Diagnostic Systems, Brussels, Belgium) machine. The system measures albumin within a linear range between 6.25 and 5...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cambiaso CL,Collet-Cassart D,Lievens M

    更新日期:1988-02-01 00:00:00

  • Comparison of urinary albumin quantification by immunoturbidimetry, competitive immunoassay, and protein-cleavage liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Increased urinary albumin excretion is a well-documented diagnostic and prognostic biomarker for renal disease. Urinary albumin is typically measured in clinical settings by immunoassay methods. However, neither a reference method nor a urine albumin calibration reference material is currently available. ME...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.129833

    authors: Seegmiller JC,Sviridov D,Larson TS,Borland TM,Hortin GL,Lieske JC

    更新日期:2009-11-01 00:00:00