Use of a programmable desk-top calculator for the statistical quality control of radioimmunoassays.

Abstract:

:We have developed an interactive statistical quality-control system for the small- to medium-sized radioimmunoassay laboratory, which can be used in a programmable desk-top calculator instead of the medium- or large-scale computer systems usually required. The design of this quality-control system is modeled after the suggestions of Rodbard and has three components. The first component evaluates the relationship between the measured response variable of the radioimmunoassay and the precision (or variance) of these measurements. This derived relationship is then used in the second component of the system as the basis for the weighting function used to calculate an interative, weighted, least squares regression of the logit-log transformation of the dose-response curve. The third component uses the quality-control parameters statistically calculated from the linearized dose-response curve to monitor whether the assay is "in-control". The calculator tabulates the means and confidence limits for the various parameters and can plot the statistical quality-control charts. The major benefit of this statistical quality-control system is that it allows the real-time computation and plotting of quality-control data with a programmable desk-top calculator.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Cernosek SF Jr,Gutierrez-Cernosek RM

subject

Has Abstract

pub_date

1978-07-01 00:00:00

pages

1121-5

issue

7

eissn

0009-9147

issn

1530-8561

journal_volume

24

pub_type

杂志文章
  • Comparison between High-Sensitivity Cardiac Troponin T and Cardiac Troponin I in a Large General Population Cohort.

    abstract:BACKGROUND:Few data compare cardiac troponin T (cTnT) and cardiac troponin I (cTnI) in a general population. We sought to evaluate the distribution and association between cTnT, cTnI, and cardiovascular risk factors in a large general population cohort. METHODS:High-sensitivity cTnT and cTnI were measured in serum fro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.292086

    authors: Welsh P,Preiss D,Shah ASV,McAllister D,Briggs A,Boachie C,McConnachie A,Hayward C,Padmanabhan S,Welsh C,Woodward M,Campbell A,Porteous D,Mills NL,Sattar N

    更新日期:2018-11-01 00:00:00

  • N-acetyl-beta-glucosaminidase isoenzymes in serum and urine of patients with diabetes mellitus.

    abstract::The isoenzyme pattern of N-acetyl-beta-glucosaminidase (NAG) in serum and urine was studied in two groups of patients with diabetes mellitus and in 30 control subjects. Total NAG activity was significantly (P less than 0.001) increased in the serum and urine of the 20 diabetics with vascular complications, but was ins...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Severini G,Aliberti LM,Di Girolamo M

    更新日期:1988-12-01 00:00:00

  • HPLC for simultaneous quantification of total ceramide, glucosylceramide, and ceramide trihexoside concentrations in plasma.

    abstract:BACKGROUND:Simple, reproducible assays are needed for the quantification of sphingolipids, ceramide (Cer), and sphingoid bases. We developed an HPLC method for simultaneous quantification of total plasma concentrations of Cer, glucosylceramide (GlcCer), and ceramide trihexoside (CTH). METHODS:After addition of sphinga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.079012

    authors: Groener JE,Poorthuis BJ,Kuiper S,Helmond MT,Hollak CE,Aerts JM

    更新日期:2007-04-01 00:00:00

  • Assays for thyrotropin-receptor binding and thyroid-stimulating antibodies in sera from patients with Graves' disease.

    abstract::We compared the activities of thyroid-stimulating antibodies (TSAb) measured in cultures of human thyrocytes and the values for thyrotropin-receptor antibodies (TRAb) as measured with a commercial kit based on use of radiolabeled receptors. Sera were obtained from patients with Graves' disease before, during, and afte...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Massart C,Hody B,Mouchel L,Edan G,Nicol M

    更新日期:1986-07-01 00:00:00

  • Findings of an external quality assessment scheme for determining aluminum in dialysis fluids and water.

    abstract::The analytical performance of laboratories participating in the dialysis fluids and water aluminum program of the Guildford External Quality Assessment Scheme over the period 1986-1993 has been reviewed. For aluminum concentrations > 3.33 mumol/L in dialysis fluids, the between-laboratory CV has fallen from approximat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Taylor A,Briggs RJ,Cevik C

    更新日期:1994-08-01 00:00:00

  • Biological variation of blood acid-base status: consequences for analytical goal-setting and interpretation of results.

    abstract::Analytical, intra-individual, and interindividual components of variation have been determined for pH, pCO2, bicarbonate, base excess, and total CO2 in capillary specimens of whole blood from a cohort of 14 healthy subjects. Calculated analytical goals (SD) are pH less than or equal to 0.008, pCO2 less than or equal t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harding PJ,Fraser CG

    更新日期:1987-08-01 00:00:00

  • Assay of prostate-specific antigen from whole blood spotted on filter paper and application to prostate cancer screening.

    abstract::We report the measure of prostate-specific antigen (PSA) from extracts of blood dried on filter paper. Five 3-mm (diameter) paper discs containing approximately 25 microL of dried whole blood were punched from the filter paper and extracted with 500 microL of buffer. Recovery of PSA was > 92%. Imprecision of the filte...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hoffman BR,Yu H,Diamandis EP

    更新日期:1996-04-01 00:00:00

  • Chemical and immunochemical measurement of total iron-binding capacity compared.

    abstract::Radiometric, colorimetric, and two immunochemical methods for measuring total iron-binding capacity are compared. We evaluated the procedures on the basis of precision, applicability to a pediatric population, and accuracy as assessed by analytical recovery of purified transferrin. The immunoephelometric assay for tra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buffone GJ,Lewis SA,Iosefsohn M,Hicks JM

    更新日期:1978-10-01 00:00:00

  • Production of murine hybrid-hybridomas secreting bispecific monoclonal antibodies for use in urease-based immunoassays.

    abstract::To produce bispecific antibodies (BiAbs) for enzyme immunoassay (EIA) to replace antibody-enzyme conjugates, we developed a panel of 8-azaguanine/ouabain-resistant anti-urease variant hybridoma cell lines for use in hybridoma-hybridoma fusions. These variants represent mouse immunoglobulin subclasses IgM, IgG1, IgG2a,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Takahashi M,Fuller SA

    更新日期:1988-09-01 00:00:00

  • Simple method for the routine determination of betaine and N,N-dimethylglycine in blood and urine.

    abstract::A simple and convenient method using commercially available derivatization reagents is described for the measurement of betaine and N,N-dimethylglycine (DMG) in blood and urine. Precolumn derivatization of plasma or urine is performed directly in acetonitrile without extraction with p-bromophenacyl bromide and crown e...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Laryea MD,Steinhagen F,Pawliczek S,Wendel U

    更新日期:1998-09-01 00:00:00

  • Molecular diagnosis of medium-chain acyl-CoA dehydrogenase deficiency by oligonucleotide ligation assay.

    abstract::Medium-chain acyl-CoA dehydrogenase (MCAD) deficiency is a recessively inherited defect in the mitochondrial beta-oxidation of fatty acids. A single nucleotide change, the A985 --> G transition, in the MCAD gene accounts for approximately 90% of all the disease-causing mutations in the patients. We have used PCR to am...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Romppanen EL,Mononen T,Mononen I

    更新日期:1998-01-01 00:00:00

  • Quantification of serum 1-84 parathyroid hormone in patients with hyperparathyroidism by immunocapture in situ digestion liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Immunoassays specific for 1-84 parathyroid hormone (PTH) reportedly reflect the bioactivity of PTH; however, PTH immunoassays can be susceptible to interference by cross-reacting PTH fragments. In addition, these assays currently lack standardization. A methodology using immunocapture purification with liqui...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.134643

    authors: Kumar V,Barnidge DR,Chen LS,Twentyman JM,Cradic KW,Grebe SK,Singh RJ

    更新日期:2010-02-01 00:00:00

  • Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin-I assay.

    abstract:BACKGROUND:Cardiac troponins are specific biochemical markers of myocardial injury used in the diagnosis of acute myocardial disease and cardiac risk stratification. To avoid misclassification of patients, troponin assays must demonstrate precision at the low end of the measuring range. We report our evaluation of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.057216

    authors: Lam Q,Black M,Youdell O,Spilsbury H,Schneider HG

    更新日期:2006-02-01 00:00:00

  • A fully automated solid-phase radioimmunoassay for triiodothyronine.

    abstract::We report the first solid-phase radioimmunoassay for triiodothyronine with use of antibody-coated tubes, which is designed specifically for the fully automated radioimmunoassay instrument, Micromedic Systems' "Concept 4 Automatic Radioassay." Antisera to triiodothyropropionic acid/bovine serum albumin were raised in r...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rugg NE,Hasler MJ,Bjornsen RE,Painter K

    更新日期:1977-05-01 00:00:00

  • Creatine kinase: stability, inactivation, reactivation.

    abstract::I determined the in vitro biological half-lives or decay constants for creatine kinase isoenzymes at various temperatures. Values at 37 degrees C are consistent with values reported by others in vivo, which suggests that in vivo irreversible inactivation is primarily thermal. Reversible inactivation appears to be an o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morin LG

    更新日期:1977-01-01 00:00:00

  • A homogeneous method for genotyping with fluorescence polarization.

    abstract::We combined the amplification refractory mutation system (ARMS) and fluorescence polarization (FP) to give a homogeneous genomic DNA genotype analysis method. Oligonucleotide probes labeled with the fluorescein dyes fluorescein isothiocyanate and 5-([4,6-dichlorotriazin-2-yl]amino)fluorescein and the rhodamine dye 6-c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gibson NJ,Gillard HL,Whitcombe D,Ferrie RM,Newton CR,Little S

    更新日期:1997-08-01 00:00:00

  • Relationships between immunogen structure and antisera specificity in the narcotic alkaloid series.

    abstract::We report the production and comparative specificities of antisera raised to different immunogens containing codeine, morphine, and oxycodone. Antisera raised to bovine serum albumin (BSA) conjugates of codeine-6-hemisuccinate, ethylmorphine-6-hemisuccinate, or oxycodone-6-carboxymethyloxime had greatest recognition o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Findlay JW,Butz RF,Jones EC

    更新日期:1981-09-01 00:00:00

  • Urokinase plasminogen activator: a prognostic marker in breast cancer including patients with axillary node-negative disease.

    abstract::Urokinase plasminogen activator (uPA) is a serine protease causally involved in cancer invasion and metastasis. In this study, high concentrations of uPA in primary breast cancers were independently associated with both a shortened disease-free interval and overall survival. For the disease-free interval as endpoint, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Duffy MJ,Duggan C,Mulcahy HE,McDermott EW,O'Higgins NJ

    更新日期:1998-06-01 00:00:00

  • Toward absolute methods in clinical chemistry: application of mass fragmentography to high-accuracy analyses.

    abstract::We review recently developed reference methods based on mass fragmentography (specific ion monitoring) with use of isotope-labeled internal standard, for determination of cholesterol, triglycerides, urea, glucose, cortisol, progesterone, and testosterone. With an optimal ratio between standard and material to be deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Björkhem I,Blomstrand R,Lantto O,Svensson L,Ohman G

    更新日期:1976-11-01 00:00:00

  • Virus-coated layer-by-layer colloids as a multiplex suspension array for the detection and quantification of virus-specific antibodies.

    abstract:BACKGROUND:Suspension array technology has surpassed ELISA for automated, simultaneous detection and quantification of soluble biomarkers such as virus-specific antibodies. We describe assays in which antigens are attached to a lipid bilayer surrounding color-coded particles. METHODS:We used layer-by-layer technology ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065789

    authors: Toellner L,Fischlechner M,Ferko B,Grabherr RM,Donath E

    更新日期:2006-08-01 00:00:00

  • Single-reagent polarization fluoroimmunoassay for barbiturates in urine.

    abstract::We describe a rapid polarization fluoroimmunoassay for screening for the presence of barbiturates in urine. The single reagent is prepared by pre-mixing antiserum with a fluorescein-labeled barbiturate derivative as tracer. Use of a mixture of two sheep antisera, raised against different barbiturate immunogens, result...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colbert DL,Smith DS,Landon J,Sidki AM

    更新日期:1984-11-01 00:00:00

  • Ultrafiltration discrepancies in recovery of myoglobin from urine.

    abstract::We investigated the efficiency, accuracy, and reliability of the ultrafiltration/dipstick methodology commonly used to diagnose myoglobinuria. Twenty-five myoglobin-containing urine specimens were filtered by centrifugation for 15 min at 1500g through a Centricon-30 membrane filter. Both the original specimen and filt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Loun B,Copeland KR,Sedor FA

    更新日期:1996-06-01 00:00:00

  • Subclass typing of IgG paraproteins by immunofixation electrophoresis.

    abstract::We present a simple method for subclass typing of IgG paraproteins, with which we have demonstrated a large number of paraproteins that were undetected by conventional immunofixation techniques. The types and distribution of IgG subclass paraproteins were analyzed in 92 human sera in which IgG paraproteins had been de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Klouche M,Bradwell AR,Wilhelm D,Kirchner H

    更新日期:1995-10-01 00:00:00

  • Report of the National Heart, Lung, and Blood Institute Workshop on Lipoprotein(a) and Cardiovascular Disease: recent advances and future directions.

    abstract::It has been estimated that approximately 37% of the US population judged to be at high risk for developing coronary artery disease (CAD), based on the National Cholesterol Education Program guidelines, have increased plasma lipoprotein(a) [Lp(a)], whereas Lp(a) is increased in only 14% of those judged to be at low ris...

    journal_title:Clinical chemistry

    pub_type:

    doi:10.1373/clinchem.2003.023689

    authors: Marcovina SM,Koschinsky ML,Albers JJ,Skarlatos S

    更新日期:2003-11-01 00:00:00

  • DNA enzyme immunoassay: general method for detecting products of polymerase chain reaction.

    abstract::We developed a new colorimetric method, DNA enzyme immunoassay (DEIA), for detecting specific hybrids of complementary nucleic acids and applied it to the detection of hepatitis B virus (HBV) DNA amplified from serum samples by means of the polymerase chain reaction (PCR) technique. The method is based on the ability ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mantero G,Zonaro A,Albertini A,Bertolo P,Primi D

    更新日期:1991-03-01 00:00:00

  • Gas-chromatographic method of analysis for urinary organic acids. II. Description of the procedure, and its application to diagnosis of patients with organic acidurias.

    abstract::A gas-chromatographic method for urinary organic acid analysis is described, designed to be used routinely for the diagnosis of organic aciduria. It involves extraction of urine with ethyl acetate, dehydration of extract residues, and trimethylsilylation. Organic acids are identified by using an extensive list of rete...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tanaka K,West-Dull A,Hine DG,Lynn TB,Lowe T

    更新日期:1980-12-01 00:00:00

  • Cross reactions in radioimmunoassay: a mathematical model for correcting assay results, as exemplified by eliminating the interference of intact thyrotropin in an assay of its beta subunit.

    abstract::To correct the results of a radioimmunoassay for beta-thyrotropin (TSH) subunit by eliminating the proportion ascribable to intact TSH, we have devised a method that experimentally reproduces the conditions under which the interference develops. Beta-TSH subunit was assayed in several preparations containing known con...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dotti C,Ceda GP,Denti L,Cavalieri S,Borasi G,Valenti G

    更新日期:1987-05-01 00:00:00

  • Validation and application of a liquid-chromatographic/enzymatic assay for individual bile acids in the serum of rats.

    abstract::A liquid-chromatographic technique with a post-column enzymatic reaction and fluorescence detection was validated for analysis of individual bile acids in the serum of rats. Extraction recoveries averaged 91.1% (SD 6.9%) for all bile acids. The assay was sensitive (minimum detection of 16.8 pmol per 100-microL injecti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson MB,Blair PC,Morris RW,Neptun DA,Deyo DF,Popp JA

    更新日期:1987-10-01 00:00:00

  • Kinetic analyses of parathyroid hormone clearance as measured by three rapid immunoassays during parathyroidectomy.

    abstract:BACKGROUND:Rapid intraoperative parathyroid hormone (PTH) measurements are an important prerequisite for minimally invasive parathyroidectomy, serving as a feasible marker for "cure" because of the short half-life of PTH. Because automated analysis may facilitate monitoring, two automated PTH assays were compared with ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bieglmayer C,Prager G,Niederle B

    更新日期:2002-10-01 00:00:00

  • Inadequate hemolysis of erythrocytes on reagent strips at low pH causes false-negative readings.

    abstract::Patients' urines gave an unexpectedly high percentage of false-negative results for erythrocytes on a reagent strip, even when the test field for ascorbic acid indicated that none of this substance was present to inhibit the test reaction. By adding known amounts of erythrocytes to normal urines, we found that this ph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levin K,Engström I

    更新日期:1984-11-01 00:00:00