Measurement of hemoglobin A1 by liquid chromatography and by agar gel electrophoresis compared.

Abstract:

:We compare measurement of total fast hemoglobin (HbA1) by "high-performance" liquid chromatography and by electrophoresis on agar gel. Blood samples were obtained from a diverse population (n = 222): offspring of two diabetic parents, diabetic patients with and without retinopathy, diabetic and non-diabetic pregnant women, patients in the coronary-care unit, and normal persons. Precision studies with a normal and an above-normal A1 sample resulted in overall CVs of 9.0% and 4.6% for the electrophoretic method and 4.4% and 2% for the chromatographic method. Linear regression analysis of values for total fast hemoglobin for the complete sample population and for each subgroup showed results of the electrophoretic method to be in excellent agreement with those by the chromatographic method. We conclude that the agar gel electrophoretic method offers a reproducible means for HbA1 determination that is comparable to the HPLC method in terms of accuracy and is highly suited for routine laboratory use.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Hayes EJ,Gleason RE,Soeldner JS,Wacks M,Blankstein L

subject

Has Abstract

pub_date

1981-03-01 00:00:00

pages

476-9

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

27

pub_type

杂志文章
  • Diet-related reference values for plasma amino acids in newborns measured by reversed-phase HPLC.

    abstract::We have measured by reversed-phase HPLC concentrations of amino acids in plasma in groups of 80 normal appropriate-weight term babies fed from birth either a casein formula (WhiteCap SMA, n = 26), a whey formula (Gold Cap SMA, n = 26), or breast milk (n = 28). They were studied from day 11 to week 15 postpartum. The t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Scott PH,Sandham S,Balmer SE,Wharton BA

    更新日期:1990-11-01 00:00:00

  • Serum erythropoietin concentrations and iron status in patients on chronic hemodialysis.

    abstract::We studied the relationship between serum erythropoietin (EPO) concentration and iron status in 67 patients undergoing chronic hemodialysis. Serum concentrations of EPO were measured by RIA with recombinant human EPO. The geometric mean of the serum EPO concentration was 10.9 int. units/L (mean +/- SD range = 7.8 - 15...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Seguchi C,Shima T,Misaki M,Takarada Y,Okazaki T

    更新日期:1992-02-01 00:00:00

  • Proficiency testing: purification of lactate dehydrogenase 1 and results of its use as a reference material in the New York State program.

    abstract::Highly purified human lactate dehydrogenase 1 has been used in an interlaboratory evaluation and improvement progran in clinical chemistry in New York State since 1971. Although there are difficulties in determining and assigning the most nearly accurate values for test samples in the absence of a reference method and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buhl SN,Copeland WH,Fasce CF Jr,Kowalski P,Richards AH,Vanderlinde RE

    更新日期:1977-06-01 00:00:00

  • Reduced bovine hemoglobin solution evaluated for use as a blood gas quality-control material.

    abstract::We evaluated a new commercially available partially purified reduced bovine hemoglobin solution (RBHS) and a new tonometer for use in the quality control of blood gas analyzers. RBHS is manufactured in three different formulations, each corresponding to three different bicarbonate-buffering capacities and concentratio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mahoney JJ,Wong RJ,Van Kessel AL

    更新日期:1993-05-01 00:00:00

  • Biological variation of lipids and lipoproteins in fingerstick blood.

    abstract::The biological variability of total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C), and calculated low-density lipoprotein cholesterol (LDL-C) was determined in three serial (monthly) capillary and venous specimens from 83 subjects. The analytes were quantified with a desktop analyz...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kafonek SD,Donovan L,Lovejoy KL,Bachorik PS

    更新日期:1996-12-01 00:00:00

  • Established and emerging markers of kidney function.

    abstract:BACKGROUND:The kidney performs a multitude of essential functions to maintain homeostasis. In clinical medicine, glomerular filtration rate (GFR) provides the best index of overall kidney function, and proteinuria adds additional information on renal and nonrenal prognosis. Several novel biomarkers of kidney injury and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2011.167494

    authors: Ferguson MA,Waikar SS

    更新日期:2012-04-01 00:00:00

  • Association between the UGT1A1 TA-repeat polymorphism and bilirubin concentration in patients with intermittent claudication: results from the CAVASIC study.

    abstract:BACKGROUND:Bilirubin has antioxidative and cytoprotective properties. Low plasma concentrations of bilirubin are reportedly associated with the development of coronary and cerebrovascular disease, and bilirubin concentrations are strongly correlated with the enzyme activity of the hepatic uridine diphosphate glucuronos...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2007.102046

    authors: Rantner B,Kollerits B,Anderwald-Stadler M,Klein-Weigel P,Gruber I,Gehringer A,Haak M,Schnapka-Köpf M,Fraedrich G,Kronenberg F

    更新日期:2008-05-01 00:00:00

  • Influences of specimen processing and storage conditions on results for plasma ammonia.

    abstract::Ammonia concentrations in plasma may increase because of contamination and deterioration of blood components during specimen handling and storage. Using replicate specimens from healthy volunteers, we studied influences of specimen processing and storage procedures on ammonia measurements made with a self-contained re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Howanitz JH,Howanitz PJ,Skrodzki CA,Iwanski JA

    更新日期:1984-06-01 00:00:00

  • Reflectance digital matrix photometry.

    abstract::We have designed and constructed a digital matrix photometer for quantitative measurement of reflected light of small chromophoric areas or colored spots. The areas are divided conceptually into small subunits in which the reflected light is measured. This is done through stepwise scanning with a photodiode array. The...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-06-01 00:00:00

  • Simultaneous measurement of eight corticosteroids by liquid chromatography, and application of the procedure to diagnosis of congenital adrenal hyperplasia.

    abstract::We describe a liquid-chromatographic procedure for simultaneously determining eight steroids in serum. We used a Zorbax ODS column and a mobile phase of methanol/isopropanol/water (44/10/46, by vol), which well resolves the steroids cortisone, cortisol, corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, androst...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wei JQ,Zhou XT,Wei JI

    更新日期:1987-08-01 00:00:00

  • Improved liquid chromatographic/immunoassay of digoxin in serum.

    abstract::This HPLC/immunoassay procedure measures digoxin in serum with no interference from digoxin metabolites or digoxin-like factors. We used solid-phase (C18 and Diol) extraction, a C18 column with a tetrahydrofuran/water mobile phase, and final quantification by fluorescence polarization immunoassay. Deslanoside and gito...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stone JA,Soldin SJ

    更新日期:1988-12-01 00:00:00

  • New manual and automated method for determining activity of creatine kinase isoenzyme MB, by use of dithiothreitol: clinical applications.

    abstract::The method is based on the selective activating capacity of dithiothreitol on creatine kinase isoenzyme MB, after isoenzyme MM is activated by glutathione. Isolated isoenzymes MM and MB of human and canine origin were assayed individually and in mixtures of known activities. When glutathione was present in the assay m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rao PS,Lukes JJ,Ayres SM,Mueller H

    更新日期:1975-10-01 00:00:00

  • Review of actual proficiency-testing performance under CLIA '67 (March 14, 1990) rules: perspective from the first year's data.

    abstract::Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Ad...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lanphear BJ,Burmeister BJ,Ehrmeyer SS,Laessig RH,Hassemer DJ

    更新日期:1992-07-01 00:00:00

  • A method for direct estimation of imprecision profiles, with reference to immunoassay data.

    abstract::A three-parameter model for directly estimating imprecision profiles from replicated immunoassay results is compared with a six-parameter indirect profile model obtained by the usual method of combining error in the raw response measurements with the slope of the standard curve. Direct estimation is likely to be less ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sadler WA,Smith MH,Legge HM

    更新日期:1988-06-01 00:00:00

  • Endogenous digoxin-like immunoreactive factors: impact on digoxin measurements and potential physiological implications.

    abstract::Various laboratories have reported endogenous digoxin-like immunoreactive factor(s) (DLIF) in blood from patients in renal failure or liver failure, from newborn infants, and from third-trimester pregnant women. Similar immunoreactivity has been detected in amniotic fluid, in cord blood, and in urine and serum from no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Valdes R Jr

    更新日期:1985-09-01 00:00:00

  • Removal of interference by erythromycin, phenazopyridine, and methenamine mandelate in the Porter-Silber reaction.

    abstract::Erythromycin, phenazopyridine, methenamine mandelate, acetazolamide, and ascorbic acid reportedly interfere with the Porter-Silber reaction in the determination of urinary 17-hydroxycorticosteroids. Sodium bisulfite, added to the urine after hydrolysis with glucuronidase, removed almost all nonsteroidal interferences ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Furuya E

    更新日期:1977-11-01 00:00:00

  • Comparison of countercurrent immunoelectrophoretic assay with commercial radioimmunoassay kits for measuring prostatic acid phosphatase.

    abstract::We evaluated and compared five commercial radioimmunoassay kits with a standard counter-immunoelectrophoretic assay for the measurement of prostatic acid phosphatase in serum. Four of the five radioimmunoassays performed as described by the supplier with respect to sensitivity, stability, precision, linearity, analyti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wright GL Jr,Schellhammer PF,Brassil DN,Sieg SM,Leffell MS

    更新日期:1981-10-01 00:00:00

  • The tortuous road to the adoption of katal for the expression of catalytic activity by the General Conference on Weights and Measures.

    abstract:BACKGROUND:The "unit" for "enzymic activity" (U = 1 micromol/min) was recommended by the International Union of Biochemistry and Molecular Biology (IUB) in 1961 and is widely used in medical laboratory reports. The general trend in metrology, however, is toward global standardization through defining units coherent wit...

    journal_title:Clinical chemistry

    pub_type: 历史文章,杂志文章

    doi:

    authors: Dybkaer R

    更新日期:2002-03-01 00:00:00

  • Utility of commonly used commercial human chorionic gonadotropin immunoassays in the diagnosis and management of trophoblastic diseases.

    abstract:BACKGROUND:Patients with trophoblastic diseases produce ordinary and irregular forms of human chorionic gonadotropin (hCG; e.g., nicked hCG, hCG missing the beta-subunit C-terminal segment, hyperglycosylated hCG, and free beta subunit) that are recognized to differing extents by automated immunometric hCG (or hCG beta)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cole LA,Shahabi S,Butler SA,Mitchell H,Newlands ES,Behrman HR,Verrill HL

    更新日期:2001-02-01 00:00:00

  • High-Speed Melting Analysis: The Effect of Melting Rate on Small Amplicon Microfluidic Genotyping.

    abstract:BACKGROUND:High-resolution DNA melting analysis of small amplicons is a simple and inexpensive technique for genotyping. Microfluidics allows precise and rapid control of temperature during melting. METHODS:Using a microfluidic platform for serial PCR and melting analysis, 4 targets containing single nucleotide varian...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.276147

    authors: Pryor RJ,Myrick JT,Palais RA,Sundberg SO,Paek JY,Wittwer CT,Knight IT

    更新日期:2017-10-01 00:00:00

  • Flow-cytometric determination of high-density-lipoprotein binding sites on human leukocytes.

    abstract::In this method, leukocytes were isolated from 6 mL of EDTA-blood by density-gradient centrifugation and subsequently incubated with rhodamine isothiocyanate (RITC)-conjugated high-density lipoproteins (HDL). The receptor-bound conjugate particles were determined by fluorescent flow cytometry and compared with 125I-lab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schmitz G,Wulf G,Brüning T,Assmann G

    更新日期:1987-12-01 00:00:00

  • Accuracy and comparability of long-term measurements of cholesterol.

    abstract::Laboratories of the Lipid Research Clinics Program (LRC) maintained the accuracy of their measurements of total cholesterol by using seven pooled serum calibrators supplied by the Centers for Disease Control (CDC). Over the 11-year life of the LRC, each calibrator was prepared in succession and a target value was assi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hainline A Jr,Karon JM,Winn CL,Gill JB

    更新日期:1986-04-01 00:00:00

  • An "oncometer" of clinical measurement of colloid osmotic pressure of plasma.

    abstract::Measurement of colloid osmotic pressure complements measurements of pulmonary artery wedge pressure for assessing the risks of pulmonary edema and constitutes an increasingly important reference for purposes of guiding selection of colloid or crystalloid fluids in patients with acute cardiac disease. We describe a sim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bisera J,Weil MH,Michaels S,Bernardo A,Stein B

    更新日期:1978-09-01 00:00:00

  • Method for testing antiserum titer and avidity in nephelometric systems.

    abstract::Antiserum performance in a nephelometric system can be characterized by parameters derived from measuring reaction rates. The characterization process is derived from a series of dose-response curves (elicited nephelometric response vs antigen concentration) generated from various dilutions of the antiserum being test...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hudson GA,Ritchie RF,Haddow JE

    更新日期:1981-11-01 00:00:00

  • A rapid, sensitive enzyme-linked immunoassay for human thyrotropin.

    abstract::In this enzyme-linked immunoassay for human thyrotropin (TSH) in unextracted serum we use 96-well immunoenzymometric assay plates, first coated with polyclonal antibody to TSH, then incubated with the serum samples and reacted with mouse monoclonal antibody to human TSH. After incubation with alkaline phosphatase-labe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tseng YC,Burman KD,Baker JR Jr,Wartofsky L

    更新日期:1985-07-01 00:00:00

  • Advanced glycosylation end products in the mesenteric artery.

    abstract::We measured advanced glycosylation end products in the mesenteric artery of 37 patients (ages 29-82 years), 34 of whom were nondiabetic. Samples of arterial tissue were obtained during bowel resectioning. Advanced glycosylation end products were measured as collagen-linked fluorescence (excitation wavelength 370 nm, e...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: MacDonald E,Lee WK,Hepburn S,Bell J,Scott PJ,Dominiczak MH

    更新日期:1992-04-01 00:00:00

  • No influence of the MDR-1 C3435T polymorphism or a CYP3A4 promoter polymorphism (CYP3A4-V allele) on dose-adjusted cyclosporin A trough concentrations or rejection incidence in stable renal transplant recipients.

    abstract:BACKGROUND:A substantial proportion of the variability in the absorption and clearance of cyclosporin A (CsA) after oral administration has been attributed to variability in liver cytochrome P-450 3A4 (CYP3A4) activity and intestinal P-glycoprotein (P-gp) concentration. A polymorphism in the CYP3A4 promoter region, ter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Ahsen N,Richter M,Grupp C,Ringe B,Oellerich M,Armstrong VW

    更新日期:2001-06-01 00:00:00

  • Soluble CD146 Is a Novel Marker of Systemic Congestion in Heart Failure Patients: An Experimental Mechanistic and Transcardiac Clinical Study.

    abstract:BACKGROUND:Soluble CD146 (sCD146), is an endothelial marker with similar diagnostic power as natriuretic peptides in decompensated heart failure (HF). While natriuretic peptides are released by the failing heart, sCD146 may be released by veins in response to stretch induced by systemic congestion in HF. This study inv...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2016.260471

    authors: Arrigo M,Truong QA,Onat D,Szymonifka J,Gayat E,Tolppanen H,Sadoune M,Demmer RT,Wong KY,Launay JM,Samuel JL,Cohen-Solal A,Januzzi JL Jr,Singh JP,Colombo PC,Mebazaa A

    更新日期:2017-01-01 00:00:00

  • Enzymatic measurement of creatine in erythrocytes.

    abstract::We describe an automated enzymatic procedure for quantifying creatine in erythrocytes. In this assay, after sample clean-up, creatine kinase (CK; EC 2.7.3.2) and pyruvate kinase (EC 2.1.7.40) are used as auxiliary enzymes; lactate dehydrogenase (EC 1.1.1.27) is used in the indicator reaction. CK is also used as the st...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Beyer C,Alting IH

    更新日期:1996-02-01 00:00:00

  • Rapid preparation of nucleotides from acid-soluble pools by chromatography on silica, as exemplified with acid extracts of cultured cells.

    abstract::A rapid technique (5-10 min) has been developed for fractionating nucleotides from base and nucleoside contaminants in acid extracts of cells, by adsorption to silica gels. Silica gels (1-mL bed volume) were washed with 5 mL of water then with 5 mL of acetonitrile/water (90/10 by vol). After applying 3-mL samples, adj...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lothrop CD Jr,Uziel M

    更新日期:1980-09-01 00:00:00