Simultaneous determination of 6-thioguanine and methyl 6-mercaptopurine nucleotides of azathioprine in red blood cells by HPLC.

Abstract:

:6-thioguanine (6-TGN) and methyl 6-mercaptopurine nucleotides (Me6-MPNs) are the two major metabolites found in erythrocytes after administration of azathioprine. In an attempt to understand the role of these metabolites in the pharmacologic and toxic activity of thiopurines, we have developed a HPLC method for the simultaneous determination of 6-TGNs and Me6-MPNs in erythrocytes. A simple and rapid treatment procedure based on deproteinization by perchloric acid with dithiothreitol is described. The nucleotides were hydrolyzed to their own bases by heating the sample for 45 min at 100 degrees C. During acid hydrolysis Me6-MP was converted into a compound analyzed on a Purospher RP18-e column with 0.02 mol/L dihydrogenophosphate buffer-methanol as eluents. With this procedure, mean recoveries of 73.1% and 84.0% for 6-TGN and Me6-MPN derivatives, respectively, were found.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Dervieux T,Boulieu R

subject

Has Abstract

pub_date

1998-03-01 00:00:00

pages

551-5

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

44

pub_type

杂志文章
  • Trace metal analysis by laser-enhanced ionization in flames.

    abstract::We review atomic flame spectrometry of metals based on the selective laser-enhancement of the rate of atomic ionization. A discussion of basic principles, prior literature, and instrumentation is followed by an overview of analytical figures of merit for the technique, and a look at its present status and areas for fu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Travis JC,Turk GC,DeVoe JR

    更新日期:1983-09-01 00:00:00

  • New Colorimetric reaction for end-point, continuous-flow, and kinetic measurement of urea.

    abstract::A reaction of urea, o-phthalaldehyde and N-(1-naphthyl)ethylenediamine is described for measurement of urea by manual, continuous-flow, and kinetic methods. The continuous-flow system requires 25 mu-l of sample; 40 samples can be analyzed per hour. The kinetic method requires no enzymes, has no lag phase, and has good...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jung D,Biggs H,Erikson J,Ledyard PU

    更新日期:1975-07-01 00:00:00

  • Modifying an enzyme immunoassay of immunoreactive trypsinogen to use time-resolved fluorescence.

    abstract::A coated microtiter-well, enzyme-linked immunometric assay for quantifying immunoreactive trypsinogen in dried blood spots was modified to use time-resolved fluorescence of europium in place of end-point enzymatic color development as the quantification step. The streptavidin-horseradish peroxidase and color developme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ryall RG,Gjerde EM,Gerace RL,Ranieri E

    更新日期:1993-02-01 00:00:00

  • Advances in the Treatment of Hemophilia: Implications for Laboratory Testing.

    abstract:BACKGROUND:Until recently, clinical laboratories have monitored hemophilia treatment by measuring coagulation factors before/after infusion of human-derived or recombinant factors. Substantial changes are expected in the near future based on new therapeutic approaches that have been or are being developed. CONTENT:Hem...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2017.284356

    authors: Tripodi A,Chantarangkul V,Novembrino C,Peyvandi F

    更新日期:2019-02-01 00:00:00

  • Molar absorptivity and the blank correction factor.

    abstract::In photometry, where both the product formed and one or several reactants absorb light at the same wavelength, the absorbance of the "blank" of the sample at the end of the reaction may be less than that measured at the beginning of the reaction, because of consumption of reactant(s). The blank correction factor for t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kroll MH,Elin RJ

    更新日期:1985-03-01 00:00:00

  • Population-based study of repeat laboratory testing.

    abstract:BACKGROUND:Test repetition could be a readily modifiable component of laboratory utilization. Laboratory test repetition has not been rigorously studied at a population-based level. Our objective was to determine the prevalence of, and charges associated with, repetition of eight common laboratory tests. METHODS:We pe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.021220

    authors: van Walraven C,Raymond M

    更新日期:2003-12-01 00:00:00

  • Immunological and colorimetric determination of prostatic acid phosphatase--technical and clinical reappraisal in symptomatic patients.

    abstract::We compared a selection of quantitative immunological methods for prostatic acid phosphatase (PAP) with routine colorimetric assays for total and tartrate-labile acid phosphatase and evaluated their relative clinical merits in the differential diagnosis of prostatic carcinoma. We also assessed a wide range of commerci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gibb I,Wilson LA,Powell PH,Tarbit I,Pratt D,Hall RR

    更新日期:1986-09-01 00:00:00

  • Use of myeloperoxidase for risk stratification in acute heart failure.

    abstract:BACKGROUND:Myeloperoxidase (MPO) is a biomarker of inflammation and oxidative stress produced by neutrophils, monocytes, and endothelial cells. Concentrations of MPO predict mortality in patients with chronic heart failure. This study sought to investigate the diagnostic accuracy and prognostic value of MPO in patients...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.142257

    authors: Reichlin T,Socrates T,Egli P,Potocki M,Breidthardt T,Arenja N,Meissner J,Noveanu M,Reiter M,Twerenbold R,Schaub N,Buser A,Mueller C

    更新日期:2010-06-01 00:00:00

  • Longitudinal concentrations of vitamin B(12) and vitamin B(12)-binding proteins during uncomplicated pregnancy.

    abstract:BACKGROUND:Because reference values for vitamin B(12) concentrations and vitamin B(12)-binding capacities for pregnant women have not been established, the reference values for nonpregnant women are often applied to assess vitamin B(12) status. The aim of the present study was to describe ranges of biochemical indices ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Koebnick C,Heins UA,Dagnelie PC,Wickramasinghe SN,Ratnayaka ID,Hothorn T,Pfahlberg AB,Hoffmann I,Lindemans J,Leitzmann C

    更新日期:2002-06-01 00:00:00

  • Two-dimensional gel electrophoresis of serum specimens from patients with monoclonal gammopathies.

    abstract::We modified the ISO-DALT two-dimensional gel electrophoresis system to allow the routine examination of serum specimens from patients with monoclonal gammopathies. This system, MC-Iso 1, is characterized by a broad pH gradient for resolving the basic immunoglobulin heavy and light chains. The increased resolution of b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tracy RP,Currie RM,Kyle RA,Young DS

    更新日期:1982-04-01 00:00:00

  • How many mistakes, how to find them.

    abstract::The topic of quality control often evokes prolific discussion among those whose business is its administration. Reliable methods for identifying mistakes must be developed in both the manufacture and use of test devices. Unit test devices are uncomplicated to run and provide quick results in a world where speed and si...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Blase AB

    更新日期:1997-05-01 00:00:00

  • Virus-coated layer-by-layer colloids as a multiplex suspension array for the detection and quantification of virus-specific antibodies.

    abstract:BACKGROUND:Suspension array technology has surpassed ELISA for automated, simultaneous detection and quantification of soluble biomarkers such as virus-specific antibodies. We describe assays in which antigens are attached to a lipid bilayer surrounding color-coded particles. METHODS:We used layer-by-layer technology ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065789

    authors: Toellner L,Fischlechner M,Ferko B,Grabherr RM,Donath E

    更新日期:2006-08-01 00:00:00

  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • Modified heparin-Sepharose procedure for determination of plasma lipolytic activities of normolipidemic and hyperlipidemic subjects after injection of heparin.

    abstract::A modified heparin-Sepharose affinity chromatography procedure (Boberg et al., J. Lipid Res. 18:544-547, 1977) was developed to determine two different triglyceride lipase activities in human post-heparin plasma: hepatic triglyceride lipase (I) and lipoprotein lipase (II). With this procedure, lipoproteins were separa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang CS,Bass HB,Downs D,Whitmer RK

    更新日期:1981-05-01 00:00:00

  • Reported effects of long-term freezer storage on concentrations of retinol, beta-carotene, and alpha-tocopherol in serum or plasma summarized.

    abstract::A literature review of the effects of long-term freezer storage on concentrations of antioxidant micronutrients in serum or plasma showed that a high proportion of the studies that compared the concentrations of retinol, beta-carotene, or alpha-tocopherol in fresh and stored serum were deficient because of small numbe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Comstock GW,Alberg AJ,Helzlsouer KJ

    更新日期:1993-06-01 00:00:00

  • Lactate dehydrogenase isoenzyme 1 as determined by inhibition with 1,6-hexanediol and by two other methods in patients with myocardial infarction or cardiac-bypass surgery.

    abstract::In this assay for lactate dehydrogenase (EC 1.1.1.27) isoenzyme 1 (LD-1), 1,6-hexanediol is added to serum after total LD has been measured. After incubation for 5 min the total LD remaining is determined. Samples from patients who had a myocardial infarction or who had undergone bypass surgery were assayed simultaneo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shamberger RJ

    更新日期:1987-04-01 00:00:00

  • Fluorometric method for phenylalanine microplate assay adapted for phenylketonuria screening.

    abstract::We adapted the method of McCaman and Robins for fluorometry of phenylalanine to a microplate assay for routine phenylketonuria screening. Sensitivity is 15 mumol/L for the plasma assay and 30 mumol/L for the dried blood-spot assay, with CV less than 10% for both assays. Results for human plasma by microplate assay cor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gerasimova NS,Steklova IV,Tuuminen T

    更新日期:1989-10-01 00:00:00

  • Use of values for calcium and protein in serum, and of a derived index obtained from a probability population sample.

    abstract::We measured serum protein and calcium concentrations in 2340 individuals between 10 and 96 years of age from 900 families chosen by probability methods to give a representative population. These values were used to calculate an index, based on a regression analysis of serum protein on calcium, which was then treated a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kelly A,Munan L,PetitClerc C,Ho KP,Billon B

    更新日期:1976-10-01 00:00:00

  • Use of a reference standard to improve the accuracy and precision of seven kits for determination of ferritin in serum.

    abstract::We assessed the accuracy and precision of seven commercial kits for serum ferritin. The concentration of ferritin as determined by these assays for a liver ferritin reference standard, a human heart ferritin standard, and normal sera correlated highly, but the absolute values varied widely. Use of an international ref...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iacobello C,Ghielmi S,Belloli S,Arosio P,Albertini A

    更新日期:1984-02-01 00:00:00

  • The role of precision in determining the performance of a thyrotropin assay in diagnosing hyperthyroidism.

    abstract::We examined the relationship between analytical sensitivity, precision at the lower limit of the reference interval, and diagnostic performance in hyperthyroidism for one radioimmunoassay and five immunometric assay kits for thyrotropin. The analytical sensitivity of these kits extended from 0.05 to 1.56 milli-int. un...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilke TJ,Utley DJ

    更新日期:1988-07-01 00:00:00

  • Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure.

    abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa287

    authors: Tan ESJ,Chan SP,Liew OW,Chong JPC,Leong GKT,Yeo DPS,Ong HY,Jaufeerally F,Yap J,Sim D,Ng TP,Ling LH,Lam CSP,Richards AM

    更新日期:2021-01-08 00:00:00

  • Iron stores, blood donation, and insulin sensitivity and secretion.

    abstract:BACKGROUND:Epidemiologists have observed that blood donation is associated with decreased risk of type 2 diabetes and cardiovascular disease. METHODS:We investigated the relationship between iron stores and insulin sensitivity, after controlling for known confounding factors, and compared insulin sensitivity between b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.046847

    authors: Fernández-Real JM,López-Bermejo A,Ricart W

    更新日期:2005-07-01 00:00:00

  • Low apparent creatine kinase activity and prolonged lag phases in serum of patients with metastatic disease: elimination by treatment of sera with sulfhydryl agents.

    abstract::We find lag phases exceeding 20 min in measuring creatine kinase activity, by using the kinetic creatin phosphate leads to creatine assay, in sera of some patients with carcinoma metastatic to the liver. Such long lag phases are accompanied by a decreased apparent enzyme activity. These problems are eliminated by addi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bruns DE,Morgan WS,Davis JE,Ladenson JH

    更新日期:1976-11-01 00:00:00

  • Changes in concentrations of C-reactive protein in serum after kidney or heart transplantation.

    abstract::C-reactive protein (CRP) concentrations were serially determined in serum after kidney or heart transplantation. The initial postsurgical CRP response in these patients was compared with that of control patients undergoing related procedures but not subjected to immunosuppressive therapy. Immunosuppression clearly dep...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Lente F,Castellani W,Abbott LB

    更新日期:1986-04-01 00:00:00

  • Development of a rapid and sensitive immunofluorometric assay for glutathione S-transferase A.

    abstract:BACKGROUND:The short half-life of the alpha-class glutathione S-transferases (GSTAs) in plasma combined with their even distribution throughout the liver lobule suggests that they may be useful complements to the more traditionally used liver markers. However, the currently available assays for measuring GSTAs in biolo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dajani LK,Paus E,Warren DJ

    更新日期:2001-05-01 00:00:00

  • Radioimmunoassay of serotonin (5-hydroxytryptamine) in cerebrospinal fluid, plasma, and serum.

    abstract::We describe a direct radioimmunoassay for serotonin (5-hydroxytryptamine) in cerebrospinal fluid, platelet-poor plasma, and serum. We raised antisera in rabbits against serotonin diazotized to a conjugate of bovine albumin and D,L-p-aminophenylalanine. Polyethylene glycol, alone or in combination with anti-rabbit immu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Engbaek F,Voldby B

    更新日期:1982-04-01 00:00:00

  • B-type natriuretic peptide forms within the heart, coronary sinus, and peripheral circulation in humans: evidence for degradation before secretion.

    abstract:BACKGROUND:The B-type natriuretic peptides (BNP and N-terminal pro-BNP) are secreted by the heart and, in the case of BNP, serve to maintain circulatory homeostasis through renal and vascular actions and oppose many effects of the renin-angiotensin system. Recent evidence suggests that in patients with severe heart fai...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.210435

    authors: Mahagamasekera PG,Ruygrok PN,Palmer SC,Richards AM,Ansell GS,Nicholls MG,Pemberton CJ,Lewis LK,Yandle TG

    更新日期:2014-03-01 00:00:00

  • Development of a chemiluminescence competitive PCR for the detection and quantification of parvovirus B19 DNA using a microplate luminometer.

    abstract:BACKGROUND:Quantitative PCR of viral nucleic acids can be useful clinically in diagnosis, risk assessment, and monitoring of antiviral therapy. We wished to develop a chemiluminescence competitive PCR (cPCR) for parvovirus B19. METHODS:Parvovirus DNA target sequences and competitor sequences were coamplified and direc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fini F,Gallinella G,Girotti S,Zerbini M,Musiani M

    更新日期:1999-09-01 00:00:00

  • Performance of an enzyme-linked immunosorbent assay system for antibodies to hepatitis C virus with two new antigens (c11/c7).

    abstract::We developed an enzyme-linked immunosorbent assay (ELISA) system for antibodies to the hepatitis C virus (HCV), using two new recombinant antigens (c11 and c7) derived from the HCV genome. The performance of this ELISA system (Imucheck HCV Ab) was examined. The CV values for both intra-assay precision and reproducibil...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Saito M,Hasegawa A,Kashiwakuma T,Kohara M,Sugi M,Miki K,Yamamoto T,Mori H,Ohta Y,Tanaka E

    更新日期:1992-12-01 00:00:00

  • Laboratory computing--process and information management supporting high-quality, cost-effective healthcare.

    abstract::One currently observes many healthcare institutions rushing to reengineer and install information systems with the expectation of achieving enhanced efficiency, competitiveness, and, it is hoped, higher patient satisfaction resulting from timely, high-quality care. Unfortunately, information system concepts, design, a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Buffone GJ,Moreau DR

    更新日期:1995-09-01 00:00:00