Reflotron assays of alanine aminotransferase and gamma-glutamyltransferase in whole-blood samples evaluated.

Abstract:

:We evaluated the Reflotron (Boehringer Mannheim) system for measuring activities of alanine aminotransferase (EC 2.6.1.2) and gamma-glutamyltransferase (EC 2.3.2.2). Within- and between-day precision were comparable with conventional analytical methods. The linear range of the methods extended to more than 40-fold the upper limit of the reference range. The methods were not influenced by moderate changes in blood rheology and also tolerated some variation in sample volume applied. We consider these methods to be suitable for use in satellite or physicians' office laboratories (with appropriate training of operators), and they can produce results that agree satisfactorily with those determined in routine laboratory practice.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

James DR,Price CP

subject

Has Abstract

pub_date

1987-06-01 00:00:00

pages

826-9

issue

6

eissn

0009-9147

issn

1530-8561

journal_volume

33

pub_type

杂志文章
  • A direct radioimmunoassay for aldosterone in plasma.

    abstract::This rapid radioimmunoassay for aldosterone is performed directly on 100 microL of unprocessed plasma, with 125I-labeled aldosterone as the labeled antigen. Our use of steroid-free plasma in preparing the standard curve resulted in an overestimate of aldosterone; this problem was overcome by adding to such plasma a mi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lun S,Espiner EA,Nicholls MG,Yandle TG

    更新日期:1983-02-01 00:00:00

  • Prognostic value of emerging neurohormones in chronic heart failure during optimization of heart failure-specific therapy.

    abstract:BACKGROUND:Serial measurements of neurohormones have been shown to improve prognostication in the setting of acute heart failure (HF) or chronic HF without therapeutic intervention. We investigated the prognostic role of serial measurements of emerging neurohormones and BNP in a cohort of chronic HF patients undergoing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.125856

    authors: Neuhold S,Huelsmann M,Strunk G,Struck J,Adlbrecht C,Gouya G,Elhenicky M,Pacher R

    更新日期:2010-01-01 00:00:00

  • Limitations of Accelerated Stability Model Based on the Arrhenius Equation for Shelf Life Estimation of In Vitro Diagnostic Products.

    abstract:BACKGROUND:An accelerated stability model based on the Arrhenius Equation can be used to estimate stability of diagnostic reagents. Here we review 3 examples in which the model does not accurately predict the stability of diagnostic reagents. METHODS:We prepared several pilot lots of quality controls materials contain...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa282

    authors: Ebrahim A,DeVore K,Fischer T

    更新日期:2020-12-04 00:00:00

  • Colorimetry of angiotensin-I converting enzyme activity in serum.

    abstract::This simple, accurate, and reproducible colorimetric method for determining the activity of angiotensin-I converting enzyme is based upon colorimetry of the quinoneimine dye produced from the substrate p-hydroxyhippuryl-L-histidyl-L-leucine by action of this enzyme through the following series of reactions. The enzyme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kasahara Y,Ashihara Y

    更新日期:1981-11-01 00:00:00

  • Proficiency testing: purification of lactate dehydrogenase 1 and results of its use as a reference material in the New York State program.

    abstract::Highly purified human lactate dehydrogenase 1 has been used in an interlaboratory evaluation and improvement progran in clinical chemistry in New York State since 1971. Although there are difficulties in determining and assigning the most nearly accurate values for test samples in the absence of a reference method and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buhl SN,Copeland WH,Fasce CF Jr,Kowalski P,Richards AH,Vanderlinde RE

    更新日期:1977-06-01 00:00:00

  • Increased concentrations of serum pentosidine in rheumatoid arthritis.

    abstract::Advanced glycosylation end products (AGEs) are thought to play an important role in the development of diabetic complications. Oxidative reactions are essential for the formation of some AGEs, termed glycoxidation products. Increased concentrations of pentosidine, one of such products, are found in tissue and serum in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rodríguez-García J,Requena JR,Rodríguez-Segade S

    更新日期:1998-02-01 00:00:00

  • Determination of quinidine by high-performance liquid chromatography.

    abstract::Quinidine in serum was measured at 330 nm, after protein precipitation, with an alkyl phenyl reversed-phase chromatographic column by peak-height determination (external standards.) Sensitivity was 0.3 mg/liter, with linear response to at least 10 mg/liter serum. Interassay precision, measured on 20 consecutive days, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Powers JL,Sadee W

    更新日期:1978-02-01 00:00:00

  • Double-antibody radioimmunoassay for factor VIII-related antigen.

    abstract::A plasma protein required for the support of ristocetin-induced platelet aggregation was isolated from antihemophilic factor concentrate and radiolabeled with 125I. A double-antibody radioimmunoassay was developed, with use of specific rabbit anti-VIII related antigen serum and goat anti-rabbit globulin. The assay is ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Green D,Reynolds N

    更新日期:1977-09-01 00:00:00

  • Separation of synthetic mixtures of sugars and of sugars in body fluids with a high-resolution carbohydrate analyzer.

    abstract::With use of a specially designed gradient-generating system, of anion-exchange resins of 10-20 mum particle diameter, and of an orcinol solution in concentrated sulfuric acid (1 g/liter) as detection reagent, a mixture of 16 carbohydrates can be separated in less than 4 h. The limit of detection for most sugars is in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Voelter W,Bauer H

    更新日期:1975-12-01 00:00:00

  • Sensitivity of immunofixation electrophoresis for detecting IgM paraproteins in serum.

    abstract::Detection and characterization of small IgM paraproteins by immunoelectrophoresis are often difficult because of (a) slow diffusion of the macromolecular immunoglobulin, and (b) the obscuring of the light chain, especially kappa, by the light chains of background polyclonal immunoglobulin (the "umbrella effect"). Vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kahn SN,Bina M

    更新日期:1988-08-01 00:00:00

  • Novel, aberrantly truncated isoform of serum CD13 in a family with high serum aminopeptidase N (CD13) activity.

    abstract:BACKGROUND:We previously reported a family in which the propositus and both her father and paternal grandmother had high serum aminopeptidase N (CD13; EC 3.4.11.2) activity (autosomal dominant). The molecular mass of the serum CD13 polypeptide of the propositus was larger than that of normal CD13, suggesting either a m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kawai M,Hara Y,Miyazato I,Hosaki S

    更新日期:2001-02-01 00:00:00

  • Critical assessment of phospholipid measurement in amniotic fluid.

    abstract::We assessed several methods of inorganic phosphate assay for their suitability in estimating phospholipids in digested extracts of amniotic fluids. The extraction and digestion procedures used for phospholipids from amniotic fluid were also examined critically. The effect of contamination by blood or obstetric cream h...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Badham LP,Worth HG

    更新日期:1975-09-01 00:00:00

  • Immunological and colorimetric determination of prostatic acid phosphatase--technical and clinical reappraisal in symptomatic patients.

    abstract::We compared a selection of quantitative immunological methods for prostatic acid phosphatase (PAP) with routine colorimetric assays for total and tartrate-labile acid phosphatase and evaluated their relative clinical merits in the differential diagnosis of prostatic carcinoma. We also assessed a wide range of commerci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gibb I,Wilson LA,Powell PH,Tarbit I,Pratt D,Hall RR

    更新日期:1986-09-01 00:00:00

  • Immunoluminometric assay for measurement of the C-terminal endothelin-1 precursor fragment in human plasma.

    abstract:BACKGROUND:Endothelin-1 (ET-1), a potent vasoconstrictor, is difficult to measure because of its instability and its binding to receptors and plasma proteins. We report a rapid, robust way to indirectly quantify ET-1 release by measuring the C-terminal ET-1 precursor fragment (CT-proET-1) without an extraction step. M...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065581

    authors: Papassotiriou J,Morgenthaler NG,Struck J,Alonso C,Bergmann A

    更新日期:2006-06-01 00:00:00

  • Falsely high high-density lipoprotein triglyceride values by the heparin-manganese precipitation method.

    abstract::Recent evidence indicates that high-density lipoprotein triglyceride (HDL-Tg) may be a predictor of coronary artery disease. We examined three methods for HDL-Tg measurement, comparing results obtained by measurement of Tg in the supernate after heparin-manganese chloride (heparin-Mn) precipitation of EDTA-treated pla...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simo IE,Kiss Z,Ooi TC

    更新日期:1988-10-01 00:00:00

  • Lipoprotein(a) and cardiovascular disease in ethnic Chinese: the Chin-Shan Community Cardiovascular Cohort Study.

    abstract:BACKGROUND:Little is known about lipoprotein(a) [Lp(a)] as a predictor of vascular events among ethnic Chinese. We prospectively investigated the association of Lp(a) with cardiovascular disease and all-cause death in a community-based cohort. METHODS:We conducted a community-based prospective cohort study of 3484 par...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.090969

    authors: Chien KL,Hsu HC,Su TC,Sung FC,Chen MF,Lee YT

    更新日期:2008-02-01 00:00:00

  • Gas-chromatographic measurement of carboxyhemoglobin in blood from mothers and newborns.

    abstract::HbCO in blood sampled from 20 mothers and newborns immediately after birth was measured with a new, simple gas-chromatographic method for CO. The mean ratio of HbCO to total hemoglobin for 13 non-smoking mothers did not differ significantly from that for their infants (mean 0.38%, SD 0.26% vs 0.38%, SD 0.13%), but the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fogh-Andersen N,Eriksen PS,Grinsted J,Siggaard-Andersen O

    更新日期:1988-01-01 00:00:00

  • Gas-chromatographic assay of free phenytoin in ultrafiltrates of plasma: test of a new filtration apparatus and specimen stability.

    abstract::I describe a gas-chromatographic procedure involving a nitrogen detector for "free" (or "unbound") phenytoin in the concentration range 0.2-4.0 mg/L in ultrafiltrates of plasma. The CV (n = 10) for the assay was 2.9% for a 0.49 mg/L concentration, 1.5% for 2.02 mg/L. The sensitivity was 0.05 mg/L. The ultrafiltration ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Joern WA

    更新日期:1981-03-01 00:00:00

  • A case of sulfhemoglobinemia and emergency measurement of sulfhemoglobin with an OSM3 CO-oximeter.

    abstract::We describe a case of sulfhemoglobinemia associated with toxic paint ingestion. Blood gases, oxygen content, and fractional hemoglobin derivatives were assayed with Radiometer 520 and OSM3 instruments. Although the CO-oximeters indicated the presence of sulfhemoglobin (SulfHb), the results were not quantitative. An OS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu C,Kenny MA

    更新日期:1997-01-01 00:00:00

  • Distinguishing Non-Small Cell Lung Cancer Subtypes in Fine Needle Aspiration Biopsies by Desorption Electrospray Ionization Mass Spectrometry Imaging.

    abstract:BACKGROUND:Distinguishing adenocarcinoma and squamous cell carcinoma subtypes of non-small cell lung cancers is critical to patient care. Preoperative minimally-invasive biopsy techniques, such as fine needle aspiration (FNA), are increasingly used for lung cancer diagnosis and subtyping. Yet, histologic distinction of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa207

    authors: Bensussan AV,Lin J,Guo C,Katz R,Krishnamurthy S,Cressman E,Eberlin LS

    更新日期:2020-11-01 00:00:00

  • Serum lipoperoxidation products in an infant with hemolytic-uremic syndrome.

    abstract::We detected increased concentrations of lipoperoxidation products, as malondialdehyde, in the serum of an infant with classic hemolytic-uremic syndrome. The concentrations declined when peritoneal dialysis was initiated and eventually returned to normal after clinical recovery. Our observation adds to the existing bod...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Brown RE,Alade SL,Knight JA,Evans BJ

    更新日期:1988-11-01 00:00:00

  • Sensitive, direct colorimetric assay for copper in serum.

    abstract::We have developed a sensitive procedure for determination of serum copper by use of the color reagent 4-(3,5-dibromo-2-pyridylazo)-N-ethyl-N-sulfopropylaniline. After mixing serum sample and reagent, and incubating at 37 degrees C for 5 min, we measure the absorbance of the resulting chelate complex at 580 nm (molar a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Abe A,Yamashita S,Noma A

    更新日期:1989-04-01 00:00:00

  • Precision of sensitivity estimations in diagnostic test evaluations. Power functions for comparisons of sensitivities of two tests.

    abstract::The precision of estimates of the sensitivity of diagnostic tests is evaluated. "Sensitivity" is defined as the fraction of diseased subjects with test values exceeding the 0.975-fractile of the distribution of control values. An estimate of the sensitivity is subject to sample variation because of variation of both c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Linnet K

    更新日期:1985-04-01 00:00:00

  • The journey to regulation of protein-based multiplex quantitative assays.

    abstract:BACKGROUND:Clinical proteomics presents great promise in biology and medicine because of its potential for improving our understanding of diseases at the molecular level and for detecting disease-related biomarkers for diagnosis, prognosis, and prediction of therapeutic responses. To realize its full potential to impro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.156034

    authors: Boja ES,Jortani SA,Ritchie J,Hoofnagle AN,Težak Ž,Mansfield E,Keller P,Rivers RC,Rahbar A,Anderson NL,Srinivas P,Rodriguez H

    更新日期:2011-04-01 00:00:00

  • Quality-control (QC) performance measures and the QC planning process.

    abstract::Numerous outcome measures can be used to characterize and compare the performance of alternative quality-control (QC) strategies. The performance measure traditionally used in the QC planning process is the probability of rejecting an analytical run when a critical out-of-control error condition exists. Another perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Parvin CA

    更新日期:1997-04-01 00:00:00

  • RNA extraction from archival formalin-fixed paraffin-embedded tissue: a comparison of manual, semiautomated, and fully automated purification methods.

    abstract:BACKGROUND:Formalin-fixed paraffin-embedded (FFPE) tumor material represents a valuable resource for the analysis of RNA-based biomarkers, both in research laboratories and in routine clinical testing. A robust and automated RNA-extraction method with a high sample throughput is required. METHODS:We evaluated extracti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.122572

    authors: Bohmann K,Hennig G,Rogel U,Poremba C,Mueller BM,Fritz P,Stoerkel S,Schaefer KL

    更新日期:2009-09-01 00:00:00

  • Five creatine kinase isoenzymes in serum of a patient with severe heart disease.

    abstract::Abnormal creatine kinase (CK) isoenzyme patterns were observed in the serum of a 64-year-old woman with severe heart disease. Agarose electrophoresis revealed the presence of all the usual CK isoenzymes (MM, MB, and BB) plus an extra band between MM and MB. Total serum CK activity was within the normal range. Within 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Csako G,Papadopoulos NM,Jett GK,McIntosh CL

    更新日期:1982-10-01 00:00:00

  • A Machine Learning Approach for the Automated Interpretation of Plasma Amino Acid Profiles.

    abstract:BACKGROUND:Plasma amino acid (PAA) profiles are used in routine clinical practice for the diagnosis and monitoring of inherited disorders of amino acid metabolism, organic acidemias, and urea cycle defects. Interpretation of PAA profiles is complex and requires substantial training and expertise to perform. Given previ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa134

    authors: Wilkes EH,Emmett E,Beltran L,Woodward GM,Carling RS

    更新日期:2020-09-01 00:00:00

  • Three assays for glycohemoglobin compared.

    abstract::Using 123 specimens, we compared the concordance of three different methods for determining glycohemoglobin (GHb): the Diamat (Bio-Rad Laboratories), an automated analyzer measuring HbA1c by cation-exchange chromatography; an assay with the IMx analyzer (Abbott Laboratories), based on boronate affinity binding; and an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Turpeinen U,Karjalainen U,Stenman UH

    更新日期:1995-02-01 00:00:00

  • Cross reactivity of digitoxin and spironolactone in two radioimmunoassays for serum digoxin.

    abstract::We measured the cross reactivity of two medications--digitoxin and spironolactone--in two digoxin radioimmunoassay (liquid and solid-phase) kit procedures. Both tests showed similar average percentages of cross reactivity with digitoxin (7.2 and 8.9% for intravenous, and 11.9 and 10.9% for oral administration), but no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Müller H,Bräuer H,Resch B

    更新日期:1978-04-01 00:00:00