Immunochemical detection of group I and group II phospholipases A2 in human serum.

Abstract:

:Time-resolved fluoroimmunoassay was developed for the detection of synovial-type phospholipase A2 (s-PLA2) in human serum. This solid-phase, sandwich assay uses a polyclonal rabbit antibody raised against synovial-type group II PLA2 produced in Escherichia coli. No cross-reactions were detected between s-PLA2 and PLA2 from human or porcine pancreas, human ascitic fluid, or bee or cobra venom. In healthy individuals, the average concentration of s-PLA2 is 3.7 micrograms/L, with a 95% reference interval from 1.3 to 10.8 micrograms/L. We investigated pancreatic PLA2, which is a group I PLA2, and synovial-type group II PLA2 in sera of patients with hematological malignancies and septic fever. The concentration of s-PLA2 was increased in patient sera and correlated significantly with the catalytic activity of PLA2 and the concentration of C-reactive protein. No correlation with the concentration of pancreatic PLA2 was found. The results suggest that the increased catalytic activity of PLA2 in sera of patients with septic fever results from synovial-type group II PLA2.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Nevalainen TJ,Kortesuo PT,Rintala E,Märki F

subject

Has Abstract

pub_date

1992-09-01 00:00:00

pages

1824-9

issue

9

eissn

0009-9147

issn

1530-8561

journal_volume

38

pub_type

杂志文章
  • Two-site enzyme immunoassay of CD4 and CD8 molecules on the surface of T lymphocytes from healthy subjects and HIV-1-infected patients.

    abstract::A highly sensitive two-site enzyme immunoassay (Capcellia) was developed to determine the concentration of CD4 and CD8 molecules expressed on the surface of human T lymphocytes. This assay, performed in one step (20 min), involves the specific immunocapture of T lymphocytes and reaction of the CD4 or CD8 molecules wit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Carriere D,Fontaine C,Berthier AM,Rouquette AM,Carayon P,Laprode M,Juillard R,Jansen A,Paoli P,Paolucci F

    更新日期:1994-01-01 00:00:00

  • Validation of RNA arbitrarily primed PCR probes hybridized to glass cDNA microarrays: application to the analysis of limited samples.

    abstract:BACKGROUND:The applicability of microarray-based transcriptome massive analysis is often limited by the need for large amounts of high-quality RNA. RNA arbitrarily primed PCR (RAP-PCR) is an unbiased fingerprinting PCR technique that reduces both the amount of initial material needed and the complexity of the transcrip...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.036236

    authors: Grau M,Solé X,Obrador A,Tarafa G,Vendrell E,Valls J,Moreno V,Peinado MA,Capellá G

    更新日期:2005-01-01 00:00:00

  • Adaptation of a T3-uptake test and of radioimmunoassays for serum digoxin, thyroxine, and triiodothyronine to an automated radioimmunoassay system--"Centria".

    abstract::We report the adaptation of four radioassays to the prototype of an automated radioimmunoassay system ("Centria," Union Carbide). The system consists of three integrated modules: (a) an automated pipettor, which dispenses samples and reagents; (b) the key module, an incubator/separator, in which centrifugal force is u...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ertingshausen G,Shapiro SI,Green G,Zborowski G

    更新日期:1975-08-01 00:00:00

  • Liquid-chromatographic separation of urinary 5-hydroxy-3-indoleacetic acid, with measurement at 254 nm.

    abstract::A "high-performance" liquid-chromatographic procedure for 5-hydroxy-3-indoleacetic acid is described and compared with a colorimetric method in which 1-nitroso-2-naphthol is used. The analyte and an internal standard, p-nitrobenzoic acid, were extracted into diethyl ether from urine at pH 4.0 (acidified with HCl) to w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Draganac PS,Steindel SJ,Trawick WG

    更新日期:1980-06-01 00:00:00

  • Apparent binding of ionized calcium by various buffers.

    abstract::Using different substance concentrations in an aqueous 1.25 mmol/L solution of CaCl2 plus NaCl to a final solution ionic strength of 160 mmol/L, we tested six buffers for their effect on measurements of ionized calcium (Ca2+). Measured Ca2+ decreased with increasing ionic strength and pH. Increasing concentrations of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Crowell JA,Bowers GN Jr

    更新日期:1985-02-01 00:00:00

  • Alternatives to radioimmunoassay: labels and methods.

    abstract::We review the following labels used as substitutes for radioisotopes in immunoassay systems: bacteriophages, chemiluminescence precursors, fluorochromes, fluorogens, fluorescence quenchers, enzymes, coenzymes, inhibitors, substrates, various particulates, metal atoms, and stable free radicals. New methods for performi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Schall RF Jr,Tenoso HJ

    更新日期:1981-07-01 00:00:00

  • Profiling plasma microRNA in nasopharyngeal carcinoma with deep sequencing.

    abstract:BACKGROUND:The goal of this study was to establish a plasma microRNA profile by use of next-generation sequencing that could aid in assessment of patient prognosis in nasopharyngeal carcinoma (NPC). METHODS:Two panels of NPC patients and healthy controls (HCs) were recruited for this study. We used deep sequencing to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.214213

    authors: Wang HY,Yan LX,Shao Q,Fu S,Zhang ZC,Ye W,Zeng YX,Shao JY

    更新日期:2014-05-01 00:00:00

  • Steroid characteristics of mineralocorticoid adrenocortical hypertension.

    abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Biglieri EG,Kater CE

    更新日期:1991-10-01 00:00:00

  • Fructosamine Test-Plus, a modified fructosamine assay evaluated.

    abstract::We have evaluated Fructosamine Test-Plus, a commercial fructosamine assay based on the reduction of nitro-blue tetrazolium dye in alkaline buffer (Clin Chem 1985;31:1550-4), modified by including a detergent and uricase in the reagent, by changing the concentrations of buffer and dye, and by changing the approach to p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Baker J,Metcalf P,Scragg R,Johnson R

    更新日期:1991-04-01 00:00:00

  • Difference in bias approach for commutability assessment: application to frozen pools of human serum measured by 8 direct methods for HDL and LDL cholesterol.

    abstract:BACKGROUND:We used a difference in bias approach to evaluate the commutability of 4 frozen serum pools for 8 direct methods for measurement of HDL and LDL cholesterol (HDLC and LDLC). METHODS:Freshly collected nonfrozen sera from 138 diseased and 37 nondiseased patients and 4 frozen pools from the CDC Lipid Standardiz...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.240861

    authors: Korzun WJ,Nilsson G,Bachmann LM,Myers GL,Sakurabayashi I,Nakajima K,Nakamura M,Shamburek RD,Remaley AT,Miller WG

    更新日期:2015-08-01 00:00:00

  • Microcalorimetric determination of glucose in reference samples of serum.

    abstract::Ireport a detailed series of microcalorimetric measurement of glucose concentrations in five reference samples of serum. The method utilized (a) calibration in the actual medium of analysis and (b) a correction for interferences owing to the nonspecificity of the enzyme hexokinase. The microcalorimetric results are co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Goldberg RN

    更新日期:1976-10-01 00:00:00

  • Method for testing antiserum titer and avidity in nephelometric systems.

    abstract::Antiserum performance in a nephelometric system can be characterized by parameters derived from measuring reaction rates. The characterization process is derived from a series of dose-response curves (elicited nephelometric response vs antigen concentration) generated from various dilutions of the antiserum being test...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hudson GA,Ritchie RF,Haddow JE

    更新日期:1981-11-01 00:00:00

  • Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure.

    abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa287

    authors: Tan ESJ,Chan SP,Liew OW,Chong JPC,Leong GKT,Yeo DPS,Ong HY,Jaufeerally F,Yap J,Sim D,Ng TP,Ling LH,Lam CSP,Richards AM

    更新日期:2021-01-08 00:00:00

  • Application of the clearance concept to hyponatremic and hypernatremic disorders: a phenomenological analysis.

    abstract::The kidney and its response to the antidiuretic hormone (ADH) are the principal protective mechanisms necessary to maintain a normal plasma tonicity (osmolality). Hence, determination of the response of the ADH-renal axis to an abnormal plasma tonicity is an important step to understanding water homeostasis. Determina...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Shoker AS

    更新日期:1994-07-01 00:00:00

  • International normalized ratio for prothrombin times in patients taking oral anticoagulants: critical difference and probability of significant change in consecutive measurements.

    abstract::To determine when a change in serial measurements of prothrombin time in patients receiving oral anticoagulant therapy (ACT) is a statistically significant biological change necessitating dose adjustment, one must know the size of the "critical difference" in statistical terms (i.e., probabilities). In a cohort of 32 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lassen JF,Brandslund I,Antonsen S

    更新日期:1995-03-01 00:00:00

  • Detection of intracellular antigens by flow cytometry: comparison of two chemical methods and microwave heating.

    abstract::Detection of intracellular antigens by flow cytometry requires effective fixation and permeabilization of the cell membrane. This study compares three fixation/permeabilization techniques: two commercial chemical reagents, the ORTHOPermeaFix (OPF) and the FIX&PERM Cell Permeabilization Kit (F&P), and a novel method ba...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Millard I,Degrave E,Philippe M,Gala JL

    更新日期:1998-11-01 00:00:00

  • "Ultrasensitive" silver stains: their use exemplified in the study of normal human cerebrospinal fluid proteins separated by two-dimensional electrophoresis.

    abstract::We have developed a series of photochemical silver stains that are more than 100 times as sensitive as the Coomassie Blue stains. These stains facilitate the quantitative estimation of proteins in two-dimensional gel patterns. Recently, we discovered that by using light (photodevelopment) to catalyze the reduction of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Merril CR,Harrington MG

    更新日期:1984-12-01 00:00:00

  • A Machine Learning Approach for the Automated Interpretation of Plasma Amino Acid Profiles.

    abstract:BACKGROUND:Plasma amino acid (PAA) profiles are used in routine clinical practice for the diagnosis and monitoring of inherited disorders of amino acid metabolism, organic acidemias, and urea cycle defects. Interpretation of PAA profiles is complex and requires substantial training and expertise to perform. Given previ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa134

    authors: Wilkes EH,Emmett E,Beltran L,Woodward GM,Carling RS

    更新日期:2020-09-01 00:00:00

  • The Longer, the Better? An Empirical Study of the Extent and Mechanisms of Attenuating Biomarker Associations in Cardiovascular Patient Cohorts.

    abstract:BACKGROUND:Identifying novel risk markers in cardiovascular patients remains a research priority. Longer follow-up generally is considered favorable in such studies, but associations of interest may become attenuated with increasing follow-up. This issue has not been adequately addressed in the context of patient cohor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.263202

    authors: Breitling LP,Mons U,Hahmann H,Koenig W,Rothenbacher D,Brenner H

    更新日期:2017-03-01 00:00:00

  • Potential use of ketoconazole in a dynamic endocrine test to differentiate between biological outliers and testosterone use by athletes.

    abstract::Determination of the ratio of testosterone to epitestosterone (T/E) in urine is used to detect testosterone administration in athletes, with a ratio > 6 considered as evidence of an offense. We show that administration of ketoconazole, which inhibits testosterone biosynthesis, may be useful for differentiating between...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kicman AT,Oftebro H,Walker C,Norman N,Cowan DA

    更新日期:1993-09-01 00:00:00

  • Use of a quality-control plasma sample to decrease interassay variation in radioimmunoassays of apolipoprotein A-I.

    abstract::The apolipoprotein A-I (apo A-I) radioimmunoassay established in our laboratory involves use of purified apo A-I as the primary standard for quantifying apo A-I in plasma and a pooled plasma (quality-control sample) as a secondary standard to decrease interassay variation. The measured values for apo A-I increased ove...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Au YP,Hallaway BJ,Kottke BA

    更新日期:1986-07-01 00:00:00

  • Quantitative homogeneous enzyme immunoassays for amitriptyline, nortriptyline, imipramine, and desipramine.

    abstract::We describe specific EMIT homogeneous enzyme immunoassays for amitriptyline, nortriptyline, imipramine, and desipramine in patients' serum samples. Before analysis, an easily performed extraction step involving the use of 500 microL of sample and a 1-mL disposable column eliminates cross-reacting polar metabolites. Th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pankey S,Collins C,Jaklitsch A,Izutsu A,Hu M,Pirio M,Singh P

    更新日期:1986-05-01 00:00:00

  • Measurement of glycosylated hemoglobin on cellulose acetate membranes by mobile affinity electrophoresis.

    abstract::In this method for separating glycosylated from nonglycosylated hemoglobin in blood by electrophoresis on cellulose acetate membranes, we exploit the affinity of low-molecular-mass dextran sulfate for the nonglycosylated fraction, which increases the mobility of the latter relative to that of glycosylated hemoglobin. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ambler J,Janik B,Walker G

    更新日期:1983-02-01 00:00:00

  • New reference intervals for thyrotropin and thyroid hormones based on National Academy of Clinical Biochemistry criteria and regular ultrasonography of the thyroid.

    abstract:BACKGROUND:The aim of our present study was to establish new reference intervals for thyrotropin (TSH) and thyroid hormones based on National Academy of Clinical Biochemistry (NACB) criteria and regular thyroid ultrasonography. We also assessed the effect of potentially confounding factors to modulate the limits of the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.047399

    authors: Kratzsch J,Fiedler GM,Leichtle A,Brügel M,Buchbinder S,Otto L,Sabri O,Matthes G,Thiery J

    更新日期:2005-08-01 00:00:00

  • Comparison and evaluation of cardiac biomarkers in patients with intermittent claudication: results from the CAVASIC study.

    abstract:BACKGROUND:Plasma concentrations of the peptides midregional proadrenomedullin (MR-proADM), midregional proatrial natriuretic peptide (MR-proANP), and C-terminal endothelin-1 precursor fragment (CT-proET-1) are increased in various cardiovascular conditions. However, there is limited information about the association a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.193656

    authors: Kollerits B,Sturm G,Lamina C,Hammerer-Lercher A,Rantner B,Stadler M,Ziera T,Struck J,Klein-Weigel P,Fraedrich G,Kronenberg F

    更新日期:2013-04-01 00:00:00

  • Multianalyte microspot immunoassay--microanalytical "compact disk" of the future.

    abstract::Throughout the 1970s, controversy centered both on immunoassay "sensitivity" per se and on the relative sensitivities of labeled antibody (Ab) and labeled analyte methods. Our theoretical studies revealed that RIA sensitivities could be surpassed only by the use of very high-specificity nonisotopic labels in "noncompe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Ekins RP,Chu FW

    更新日期:1991-11-01 00:00:00

  • Comparison of calculated and measured free thyroid hormones in serum in health and in abnormal states.

    abstract::To evaluate a theoretical model for calculating free thyroid hormones, based on the law of mass action, we compared values for both calculated and measured free thyroxin and free triiodothyronine in a group of normal subjects. To determine whether the concentrations of circulating free hormones were also predictable f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fresco G,Curti G,Biggi A,Fontana B

    更新日期:1982-06-01 00:00:00

  • Liquid-phase reactions started by rehydrating lyophilized reagents in a centrifugal analyzer.

    abstract::In the disposable rotor of the SAM microcentrifugal analyzer, various lyophilized reagents are predistributed in 24 33-microL cuvets, for determination of multiple analytes in one specimen (e.g., for patient profiles). We evaluated a prototype of this system, which can be used at 25, 30, or 37 degrees C; absorbance re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Truchaud A,Glikmanas G,Gourmelin Y,Hersant J,Trepo D,Foray G,Collombel C

    更新日期:1985-09-01 00:00:00

  • Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

    abstract::We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jiménez A,Arenas J,Santos I,Martínez A

    更新日期:1986-08-01 00:00:00

  • Interlaboratory/intermethod differences in functional sensitivity of immunometric assays of thyrotropin (TSH) and impact on reliability of measurement of subnormal concentrations of TSH.

    abstract::Clinically relevant interassay precision profiles for thyrotropin (thyroid-stimulating hormone; TSH) were constructed with human serum pools measured over 4-8 weeks by six immunometric assays, in at least two different reagent lots. Functional sensitivities (the concentration at which the interassay CV is < or = 20%) ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Spencer CA,Takeuchi M,Kazarosyan M,MacKenzie F,Beckett GJ,Wilkinson E

    更新日期:1995-03-01 00:00:00