Semiautomated procedures for evaluation of carbohydrate-deficient transferrin in the diagnosis of alcohol abuse.

Abstract:

:Carbohydrate-deficient transferrin (CDT) may now be the most valuable biological marker for diagnosis of alcohol abuse. We compared the diagnostic performance of two new CDT tests, Axis %CDT turbidimetric immunoassay (TIA) and Axis %CDT HPLC, against Specialty Laboratories' isoelectric focusing/immunoblotting/laser densitometry (IEF/IB/LD). Both Axis tests include one-half the concentration of trisialotransferrin isoforms in their CDT quantitation schemes. Considering an alcohol abuse prevalence of 7%, Axis %CDT TIA shows a sensitivity of 87% at 98% specificity and a positive predictive value (PPV) of 0.75; %CDT HPLC shows a sensitivity of 87% at 100% specificity for a PPV of 1, and the IEF/IB/LD shows 81% sensitivity at 94% specificity for a PPV of 0.5. All three CDT tests show the same negative predictive value (0.98). Both Axis procedures perform better than IEF/IB/LD in the diagnosis of alcohol abuse; %CDT TIA is available in several semiautomated, cost-effective formats.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Bean P,Liegmann K,Løvli T,Westby C,Sundrehagen E

subject

Has Abstract

pub_date

1997-06-01 00:00:00

pages

983-9

issue

6 Pt 1

eissn

0009-9147

issn

1530-8561

journal_volume

43

pub_type

临床试验,杂志文章
  • Detecting benzodiazepines: immunoassays compared with negative chemical ionization gas chromatography/mass spectrometry.

    abstract::We tested 231 urine samples by six immunoassay methods--EMIT d.a.u., EMIT II, Roche Abuscreen Online, Abbott TDx, Diagnostic Products Corp. (DPC) double-antibody radioimmunoassay (RIA), and Biosite Triage--and by negative chemical ionization gas chromatography/mass spectrometry to determine how the immunoassays perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fitzgerald RL,Rexin DA,Herold DA

    更新日期:1994-03-01 00:00:00

  • Specific 125I-radioimmunoassay for cholyglycine, a bile acid, in serum.

    abstract::The concentration of the conjugated bile acid, cholylglycine, in serum is a sensitive and specific indicator of hepatic function. We describe a convenient, specific, and precise radioimmunoassay for cholylglycine, in which 125I-labeled cholylglycyltyrosine is used as tracer. In addition, a blocking agent in the buffer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miller P,Weiss S,Cornell M,Dockery J

    更新日期:1981-10-01 00:00:00

  • Simultaneous assay of corticosterone and cortisol in plasma by reversed-phase liquid chromatography.

    abstract::We have developed a simple, specific, and sensitive reversed-phase liquid-chromatographic method for accurate and simultaneous analysis of corticosterone and cortisol in human plasma. We achieved a detection limit of 300 ng/L for both steroids by modifying the old solid-phase extraction method to make use of "Tef Elut...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hariharan M,Naga S,VanNoord T,Kindt EK

    更新日期:1992-03-01 00:00:00

  • Multicenter evaluation of Iso-ALP test kit for measurement of bone alkaline phosphatase activity in serum and plasma.

    abstract::A test kit (Iso-ALP, Boehringer Mannheim) for measuring human bone alkaline phosphatase activity in serum or plasma was evaluated in five laboratories in three countries. The assay is based on the principle described by Rosalki and Foo (Clin Chem 1984;30:1182-6) and uses wheat germ lectin to precipitate bone alkaline ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosalki SB,Foo AY,Burlina A,Prellwitz W,Stieber P,Neumeier D,Klein G,Poppe WA,Bodenmüller H

    更新日期:1993-04-01 00:00:00

  • Clinical sensitivity and specificity of meconium fatty acid ethyl ester, ethyl glucuronide, and ethyl sulfate for detecting maternal drinking during pregnancy.

    abstract:BACKGROUND:We investigated agreement between self-reported prenatal alcohol exposure (PAE) and objective meconium alcohol markers to determine the optimal meconium marker and threshold for identifying PAE. METHODS:Meconium fatty acid ethyl esters (FAEE), ethyl glucuronide (EtG), and ethyl sulfate (EtS) were quantified...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.233718

    authors: Himes SK,Dukes KA,Tripp T,Petersen JM,Raffo C,Burd L,Odendaal H,Elliott AJ,Hereld D,Signore C,Willinger M,Huestis MA,Prenatal Alcohol in SIDS and Stillbirth (PASS) Network.

    更新日期:2015-03-01 00:00:00

  • Solid-phase enzyme immunoassay of terminal deoxynucleotidyl transferase evaluated.

    abstract::We evaluated a newly developed solid-phase immunoassay (EIA) of terminal deoxynucleotidyl transferase (TdT, EC 2.7.7.3) and compared it with the enzymatic assay of TdT involving DNA polymerase. We assessed the precision, performance characteristics, and clinical efficacy of the EIA procedure, using 249 specimens of pe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fleisher M,Stankievic R,Schwartz D,Schwartz MK

    更新日期:1987-02-01 00:00:00

  • New noncompetitive immunoassays of small analytes.

    abstract::We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)-labeled bivalent anti-T3 was incubated with the sample, producing AE-anti-T3/T3 complexes and unreacted AE-anti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Piran U,Riordan WJ,Livshin LA

    更新日期:1995-07-01 00:00:00

  • Clinical significance of lipoprotein size and risk for coronary atherosclerosis.

    abstract::Correlation between coronary heart disease and lipoprotein size and composition is well documented. Within the low-density lipoprotein (LDL) family the small LDL particles are associated with increased risk of coronary heart disease. These particles also have increased apolipoprotein (apo) B content. The appearance of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Roheim PS,Asztalos BF

    更新日期:1995-01-01 00:00:00

  • Distribution of CII and CIII peptides in lipoprotein classes: methods and clinical significance.

    abstract::We describe a method for measuring apolipoprotein (apo) C distribution between apo B-containing lipoprotein (apo B-LP) and non-apo B-LP. The procedure requires the precipitation of apo B-LP, the redissolution of the pellet, and the quantification of C peptides in the redissolved pellet. The ratio of apo C in non-apo B...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Graziani MS,Zanolla L,Righetti G,Marchetti C,Zanotto G,Lupo A

    更新日期:1994-02-01 00:00:00

  • Diagnostic accuracy of pancreatic enzymes evaluated by use of multivariate data analysis.

    abstract::We analyzed pancreatic enzyme data from 508 patients with suspected pancreatitis by neural network analysis, by an Expert multirule generation protocol, and by receiver-operator characteristic (ROC) curve analysis of a single test result. Neural network analysis showed that use of lipase provided the best means for di...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kazmierczak SC,Catrou PG,Van Lente F

    更新日期:1993-09-01 00:00:00

  • Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement.

    abstract:BACKGROUND:Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.118000

    authors: Campbell DJ,Nussberger J,Stowasser M,Danser AH,Morganti A,Frandsen E,Ménard J

    更新日期:2009-05-01 00:00:00

  • Ligase chain reaction assay for human mutations: the Sickle Cell by LCR assay.

    abstract::We can detect the beta-globin gene sickle cell mutation by using an assay based on the ligase chain reaction. The simultaneous amplification of the human growth hormone gene in the same reaction serves as a control for the amount of template DNA or amplification efficiency. Ligation products, which are biotinylated at...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Reyes AA,Carrera P,Cardillo E,Ugozzoli L,Lowery JD,Lin CI,Go M,Ferrari M,Wallace RB

    更新日期:1997-01-01 00:00:00

  • Homogeneous apoenzyme reactivation immunoassay for thyroxin-binding globulin in serum.

    abstract::In this automated apoenzyme reactivation immunoassay system (Ames Optimate) for thyroxin-binding globulin (TBG), the sample and N6-aminohexylflavin adenine dinucleotide-labeled TBG react sequentially with antiserum. Then apoglucose oxidase is added to combine with the free fraction and generate glucose oxidase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schroeder HR,Johnson PK,Dean CL,Morris DL,Smith D,Refetoff S

    更新日期:1986-05-01 00:00:00

  • New manual and automated method for determining activity of creatine kinase isoenzyme MB, by use of dithiothreitol: clinical applications.

    abstract::The method is based on the selective activating capacity of dithiothreitol on creatine kinase isoenzyme MB, after isoenzyme MM is activated by glutathione. Isolated isoenzymes MM and MB of human and canine origin were assayed individually and in mixtures of known activities. When glutathione was present in the assay m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rao PS,Lukes JJ,Ayres SM,Mueller H

    更新日期:1975-10-01 00:00:00

  • Comparison of double- and single-isotope enzymatic derivative methods for measuring catecholamines in human plasma.

    abstract::We directly compared the reliability of a single-isotope enzymatic derivative technique for measurement of plasma catecholamines with that of the well-established double-isotope method. A significant (p less than 0.001) correlation was observed between measurements (n = 52) in the two assays, both for norepinephrine (...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Evans MI,Halter JB,Porte D Jr

    更新日期:1978-04-01 00:00:00

  • Strand displacement amplification (SDA) and transient-state fluorescence polarization detection of Mycobacterium tuberculosis DNA.

    abstract::Strand displacement amplification (SDA) is an isothermal, in vitro method of amplifying a DNA sequence for diagnostic purposes. We have combined SDA with fluorescence polarization detection in a closed, homogeneous format. A fluorescently labeled oligodeoxynucleotide detector probe hybridizes to the amplification prod...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Walker GT,Nadeau JG,Linn CP,Devlin RF,Dandliker WB

    更新日期:1996-01-01 00:00:00

  • Simultaneous measurement of eight corticosteroids by liquid chromatography, and application of the procedure to diagnosis of congenital adrenal hyperplasia.

    abstract::We describe a liquid-chromatographic procedure for simultaneously determining eight steroids in serum. We used a Zorbax ODS column and a mobile phase of methanol/isopropanol/water (44/10/46, by vol), which well resolves the steroids cortisone, cortisol, corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, androst...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wei JQ,Zhou XT,Wei JI

    更新日期:1987-08-01 00:00:00

  • Development of a novel immunoassay for the assessment of plasma Gas6 concentrations and their variation with hormonal status.

    abstract:BACKGROUND:Gas6 is a vitamin K-dependent antiapoptotic protein that has been implicated in cardiovascular pathophysiology. We report the development and validation of an ELISA for Gas6, and the variation of plasma Gas6 with hormonal status in a study designed to evaluate the effect of oral contraception on plasma marke...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.089102

    authors: Clauser S,Peyrard S,Gaussem P,Crespin M,Emmerich J,Aiach M,Borgel D

    更新日期:2007-10-01 00:00:00

  • Radioimmunoassay of creatine kinase isoenzymes in human serum: isoenzyme MM.

    abstract::Measurement of the mass concentration of serum enzymes by radioimmunoassay provides direct quantitation of specific isoenzymes and may be less subject to some of the limitations of traditional assay procedures for enzymes. We describe the development of a sensitive and specific radioimmunoassay for the muscle isoenzym...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Steirteghem AC,Zweig MH,Schechter AN

    更新日期:1978-03-01 00:00:00

  • Immunoassays for low concentrations of albumin in urine.

    abstract::We have developed and validated simple, rapid immunoassays to measure concentrations of albumin in urine ranging from 5 to 200 mg/L. We use antiserum to human albumin, raised in sheep, and we separate the antibody-bound and free fractions of albumin by using a second antiserum, produced in donkeys, against the Fc frag...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Silver A,Dawnay A,Landon J,Cattell WR

    更新日期:1986-07-01 00:00:00

  • Mycophenolic acid binding to human serum albumin: characterization and relation to pharmacodynamics.

    abstract::Mycophenolate mofetil, the prodrug form of the immunosuppressive agent mycophenolic acid (MPA), is currently in clinical trials evaluating its effectiveness in transplant recipients. In this study, we validated an ultrafiltration system for the reliable measurement of free MPA. Using this technique, we evaluated facto...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nowak I,Shaw LM

    更新日期:1995-07-01 00:00:00

  • LOX index, a novel predictive biochemical marker for coronary heart disease and stroke.

    abstract:BACKGROUND:Lectin-like oxidized LDL receptor 1 (LOX-1) is implicated in atherothrombotic diseases. Activation of LOX-1 in humans can be evaluated by use of the LOX index, obtained by multiplying the circulating concentration of LOX-1 ligands containing apolipoprotein B (LAB) times that of the soluble form of LOX-1 (sLO...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140707

    authors: Inoue N,Okamura T,Kokubo Y,Fujita Y,Sato Y,Nakanishi M,Yanagida K,Kakino A,Iwamoto S,Watanabe M,Ogura S,Otsui K,Matsuda H,Uchida K,Yoshimoto R,Sawamura T

    更新日期:2010-04-01 00:00:00

  • Differentiating two forms of plasma lipase by use of media with different ionic strengths.

    abstract::Three different techniques of lipase (EC 3.1.1.3) determination (titrimetry, nephelometry, and enzyme immunoassay) were used to investigate an interesting effect of ionic strength on enzyme activity. Both activation in the presence of NaCl (140 mmol/L) and strong immunoinhibition were observed for lipase from plasma o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Arzoglou PL,Férard G,Métais P

    更新日期:1984-03-01 00:00:00

  • Comprehensive one-step molecular analyses of mitochondrial genome by massively parallel sequencing.

    abstract:BACKGROUND:Mitochondrial diseases are clinically and genetically heterogeneous, with variable penetrance, expressivity, and differing age of onset. Disease-causing point mutations and large deletions in the mitochondrial genome often exist in a heteroplasmic state. Current molecular analyses require multiple different ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.181438

    authors: Zhang W,Cui H,Wong LJ

    更新日期:2012-09-01 00:00:00

  • Monoclonal antibody inhibiting creatine kinase MM3 but not isoform MM1.

    abstract::Monoclonal antibody CKM-G01 inhibited greater than 99% of the activity of porcine and human creatine kinase(CK)-MM isoenzyme purified from muscle. However, it inhibited only 54% of CK-MM in human serum. Chromatofocusing of serum CK-MM showed that CKM-G01 inhibited 100% of MM3 but not isoform MM1. CKM-G01 inhibited CK-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suzuki T,Shiraishi T,Tomita K,Totani M,Murachi T

    更新日期:1990-01-01 00:00:00

  • Highly sensitive enzyme immunoassay of proinsulin immunoreactivity with use of two monoclonal antibodies.

    abstract::A highly sensitive two-site sandwich ELISA measuring total proinsulin immunoreactive material in serum or plasma was developed. The assay was based on two monoclonal antibodies, an anti-C-peptide antibody bound to a microtest plate and a biotin-labeled anti-insulin antibody. The detection limit (3 SD above zero value)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kjems LL,Røder ME,Dinesen B,Hartling SG,Jørgensen PN,Binder C

    更新日期:1993-10-01 00:00:00

  • Immunochemical detection of group I and group II phospholipases A2 in human serum.

    abstract::Time-resolved fluoroimmunoassay was developed for the detection of synovial-type phospholipase A2 (s-PLA2) in human serum. This solid-phase, sandwich assay uses a polyclonal rabbit antibody raised against synovial-type group II PLA2 produced in Escherichia coli. No cross-reactions were detected between s-PLA2 and PLA2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nevalainen TJ,Kortesuo PT,Rintala E,Märki F

    更新日期:1992-09-01 00:00:00

  • Incubation with neuraminidase and affinity electrophoresis with wheat-germ lectin compared for separating and quantifying alkaline phosphatase isoenzymes in plasma.

    abstract::Of 98 patients' specimens examined for alkaline phosphatase (EC 3.1.3.1) isoenzymes by electrophoresis on cellulose acetate membrane after incubation with neuraminidase, 50 showed only a single liver or bone isoenzyme staining band; in 15 of these, the tissue origin of the fraction could not be accurately identified f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosalki SB,Foo AY

    更新日期:1985-07-01 00:00:00

  • Outliers as a cause of false cardiac troponin results: investigating the robustness of 4 contemporary assays.

    abstract:BACKGROUND:It is important that cardiac troponin be measured accurately with a robust method to limit false results with potentially adverse clinical outcomes. In this study, we characterized the robustness of 4 analytical platforms by measuring the outlier rate between duplicate results. METHODS:We measured cardiac t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.159830

    authors: Pretorius CJ,Dimeski G,O'Rourke PK,Marquart L,Tyack SA,Wilgen U,Ungerer JP

    更新日期:2011-05-01 00:00:00

  • Centrifugal ion-selective electrode system for potassium in whole blood.

    abstract::We describe a novel ion-selective electrode (ISE) system that can be used in the Abbott Vision analyzer. A reusable sensor pack and a disposable test pack have been miniaturized to approximately the size and weight of a conventional Vision test pack, thus eliminating the need for a separate ISE module. The sensor pack...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Brackett J,Durley B,Janczak R,Kazlauskas V,Kmiec J,Norlie J,Rosencranz R,Schultz S,Spring T,Theusch W