Abstract:
BACKGROUND:Technological advances have resulted in a renaissance of proteomic studies directed at finding markers of disease progression, diagnosis, or responsiveness to therapy. Renal diseases are ideally suited for such research, given that urine is an easily accessible biofluid and its protein content is derived mainly from the kidney. Current renal prognostic markers have limited value, and renal biopsy remains the sole method for establishing a diagnosis. Mass spectrometry instruments, which can detect thousands of proteins at nanomolar (or even femtomolar) concentrations, may be expected to allow the discovery of improved markers of progression, diagnosis, or treatment responsiveness. CONTENT:In this review we describe the strengths and limitations of proteomic methods and the drawbacks of existing biomarkers, and provide an overview of opportunities in the field. We also highlight several proteomic studies of biomarkers of renal diseases selected from the plethora of studies performed. SUMMARY:It is clear that the field of proteomics has not yet fulfilled its promise. However, ongoing efforts to standardize sample collection and preparation, improve study designs, perform multicenter validations, and create joint industry-regulatory bodies offer promise for the recognition of novel molecules that could change clinical nephrology forever.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Konvalinka A,Scholey JW,Diamandis EPdoi
10.1373/clinchem.2011.165969subject
Has Abstractpub_date
2012-02-01 00:00:00pages
353-65issue
2eissn
0009-9147issn
1530-8561pii
clinchem.2011.165969journal_volume
58pub_type
杂志文章,评审abstract::Owing to increased enzymatic hydrolysis of glutamine, additional ammonia is formed in blood and plasma specimens with increased gamma-glutamyltransferase activity (gamma-GT, EC 2.3.2.2.). The close correlation between gamma-GT and glutaminase (EC 3.5.1.2) activities (r = 0.97) in plasma, the inhibition with 6-diazo-5-...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-08-01 00:00:00
abstract::Numerous papers have been written to show which combinations of Shewhart-type quality-control charts are optimal for detecting systematic shifts in the mean response of a process, increases in the random error of a process, and linear drift effects in the mean response across the assay batch. One paper by Westgard et ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-08-01 00:00:00
abstract::During phase I/II clinical trials of sirolimus (rapamycin; SRL), therapeutic drug monitoring was performed with a multistep liquid-liquid extraction of 1-mL aliquots of whole blood followed by reversed-phase HPLC with ultraviolet detection. Blood was sampled according to a standardized protocol and clinical status. SR...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-12-01 00:00:00
abstract::We evaluated a method for quantifying high-density lipoprotein cholesterol in plasma, based on electrophoretic migration of the prestained (with Sudan Black III) sample through a discontinuous polyacrylamide++ gel and densitometric integration of the stain associated with each class of lipoprotein. With this method, o...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-11-01 00:00:00
abstract::The identification of nicotinamide-N1-oxide as a metabolite in the urine of a schizophrenic patient prompted a study of the relative metabolism of nicotinic acid and nicotinamide in mental patients and healthy volunteers. Metabolites quantified included N1-methyl-2-pyridone-5-carboxamide, N1-methyl-4-pyridone-3-carbox...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-11-01 00:00:00
abstract::We evaluated the density-gradient ultracentrifugation method in a swinging-bucket rotor (Anal Biochem 111, 149-157, 1981) in a slightly modified version for isolation and determination of high-density lipoprotein (HDL) subfractions. We prestained the serum with Coomassie Brilliant Blue R, which did not change the hydr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-04-01 00:00:00
abstract:BACKGROUND:We evaluated the analytical performance of 4 cystatin C assays (Siemens N Latex on BNII, Roche Tina-quant on Cobas c501, Genzyme on Cobas c501, and Tosoh ST AIA-PACK on Tosoh AIA-600II) according to guidelines published by the Clinical and Laboratory Standards Institute. METHODS:We evaluated total imprecisi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.141531
更新日期:2010-08-01 00:00:00
abstract::A "sandwich" enzyme immunoassay for ferritin in human serum is described, in which horseradish peroxidase-labeled antibody and a very sensitive chromogen, 2,2'-azino-di(3-ethyl-benzthiazolin-6-sulfonate), are used. The solid phase is polypropylene test tubes treated with glutaraldehyde; immunologic reactions are devel...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-04-01 00:00:00
abstract:BACKGROUND:The American Diabetes Association task force on standardization of insulin assays in 1996 showed wide variation in assay bias. Newer assays are specific for insulin, with several now available on automated immunoassay analyzers. METHODS:In 2004, we compared 11 commercially available insulin assays by analyz...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:10.1373/clinchem.2006.077784
更新日期:2007-05-01 00:00:00
abstract::This rapid radioimmunoassay for aldosterone is performed directly on 100 microL of unprocessed plasma, with 125I-labeled aldosterone as the labeled antigen. Our use of steroid-free plasma in preparing the standard curve resulted in an overestimate of aldosterone; this problem was overcome by adding to such plasma a mi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-02-01 00:00:00
abstract:BACKGROUND:Quantitative, miniaturized nucleic acid assays and immunoassays can be developed with single microparticles, microfluorometric detection, and intrinsically fluorescent lanthanide chelates in a multiple assay format to decrease reagent consumption, cost, and assay time. We used recombinant Fab fragments to ca...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-11-01 00:00:00
abstract::Using automated measurements of kappa and lambda light chains and IgG, IgA, and IgM, we assessed the utility of the kappa/lambda ratio and the heavy chain/light chain ratio in characterizing monoclonal immunoglobulins previously identified by sensitive electrophoresis on agarose gel and typed by immunofixation or immu...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-10-01 00:00:00
abstract::Over the past decade, significant improvements in immunochemical and electrophoretic techniques have enabled collection of heretofore unavailable data on proteins in biological fluids, greatly increasing our understanding of protein physiology in the various body compartments and providing the foundation for clinical ...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1982-05-01 00:00:00
abstract:BACKGROUND:Standardization of clinical measurements of C-reactive protein (CRP) is based on the availability of reference materials. The serum protein reference material ERM-DA470 was used as a calibrant for various commercially available immunoassays but has now been exhausted. The recently released ERM-DA470k/IFCC wa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.147124
更新日期:2010-09-01 00:00:00
abstract::Zinc is determined in neutrophils and lymphocytes (isolated from whole blood on discontinuous gradients of Ficoll-Hypaque) and in microliter quantities of plasma and erythrocytes by flameless atomic absorption spectrophotometry with greater sensitivity than with conventional flame atomic absorption spectrophotometry. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-03-01 00:00:00
abstract::Serum amyloid A (SAA), a sensitive acute-phase protein, is the precursor of AA fibrils in reactive amyloidosis. However, SAA is poorly immunogenic, and development and standardization of immunoassays of this protein have been difficult. We established an automated polyclonal/monoclonal microparticle capture enzyme imm...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-07-01 00:00:00
abstract:BACKGROUND:Clinical assessment of vitamin D status often relies on measuring total circulating 25-hydroxyvitamin D3 (25OHD3), but much of each vitamin D metabolite is bound to plasma vitamin D-binding protein (DBP), such that the percentage of free vitamin is very low. We hypothesized that measurement of free rather th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.059568
更新日期:2006-02-01 00:00:00
abstract:BACKGROUND:Mass spectrometric assays could potentially replace protein immunoassays in many applications. Previous studies have demonstrated the utility of liquid chromatography-multiple-reaction monitoring-mass spectrometry (LC-MRM/MS) for the quantification of proteins in biological samples, and many examples of the ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2011.173856
更新日期:2012-04-01 00:00:00
abstract::Major depression is one of the most common clinical problems seen by primary-care physicians. The prevalence is 5% to 10% in primary-care outpatients and 15% in medically ill inpatients. Despite this high prevalence rate, depression is frequently not accurately diagnosed. Evidence suggests that misdiagnosis often occu...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1988-05-01 00:00:00
abstract::We evaluated plasma selenium concentrations in patients with euthyroid sick syndrome express by low serum triiodothyronine (T3) concentrations. Selenium status in these patients was compared with that found in patients with both untreated and treated hypothyroidism. Selenium concentrations in plasma were significantly...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-09-01 00:00:00
abstract::We describe an enzyme-linked two-site immunoassay for quantitation of intact insulin in human serum and plasma. The method uses two murine monoclonal antibodies that bind to two different epitopes on the insulin molecule. The immunoassay is specific. Human proinsulin is not bound by the antibodies, and the binding of ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-04-01 00:00:00
abstract::Highly purified human lactate dehydrogenases I and V were assayed in 17 different buffers, at a variety of reaction pH's. Diethanolamine and 2-amino-2-methyl-1,3-propanediol provided the best measurements of the enzyme, assayed lactate-to-pyruvate. However, the commercial preparation of 2-amino-2-methyl-1,3-propanedio...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-11-01 00:00:00
abstract::Ion chromatography is a new analytical technique in which the ions to be analyzed are separated on a special pellicular ion-exchange column. Once separated, the effluent from the separating column passes into a second ion-exchange column, which removes the eluent or buffer ions from the moving phase without removing t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-09-01 00:00:00
abstract::We studied the EMIT (Enzyme Multiplied Immunoassay Technique, Syva) procedures for the assay of phenytoin and phenobarbital in serum, adapting them to the miniature Centrifugal Fast Analyzer. For different concentrations of drug, each rate of reaction decreased continuously with time, tending to converge on a single c...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-08-01 00:00:00
abstract:BACKGROUND:Coffee consumption has been associated with several risk factors for coronary heart disease, including increased cholesterol, increased blood pressure, and increased plasma total homocysteine (tHcy). tHcy is determined by several B-vitamins. However, reports about the association between coffee intake and B-...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.103465
更新日期:2008-09-01 00:00:00
abstract:BACKGROUND:A previously developed monoclonal/polyclonal ELISA (Mono/Poly) to detect plasma concentrations of osteopontin (OPN) was shown to provide prognostic information in breast, prostate, and other cancers. Here we describe the clinical validation of a new dual monoclonal (Dual Mono) assay. We compared both assays ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.117465
更新日期:2009-05-01 00:00:00
abstract:BACKGROUND:It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.046995
更新日期:2005-08-01 00:00:00
abstract:BACKGROUND:Adiponectin is an adipocyte-derived hormone circulating in different multimer complexes. The high-molecular-weight (HMW) complex is likely the active form of this protein and has been recognized as a risk marker for type 2 diabetes and coronary artery disease (CAD). Because quantification of HMW adiponectin ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.112425
更新日期:2009-03-01 00:00:00
abstract::We measured immunoglobulins in the sera of 33 patients on days 1, 3, 6, 10, and 17 and three to four weeks after surgical operations (mostly hysterectomy or appendectomy) or (six patients) after spinal injury. In the absence of infection or blood transfusion, IgG usually decreased slightly and transiently after hyster...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-05-01 00:00:00
abstract::We have reported (Clin Chem 29: 42-44, 1983) that prestaining with Remazol Brilliant Blue permits direct visualization of serum components on disc electrophoresis, and apparently purifies the proteins well. Here we have cut out the bands corresponding to the prestained albumin and transferrin after disc electrophoresi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-07-01 00:00:00