Multilayer fluorescent immunoassay technique.

Abstract:

:We describe a new multilayer immunoassay element for the determination of haptens in undiluted serum and plasma. Polysaccharide layers are coated onto a plastic base. The signal layer contains an immobilized antibody and a fluorescent-labeled hapten. A second layer, containing a pigment, acts as an optical screen. Sample spreading is achieved by a molded grid in contact with the upper layer of the immunoassay element. After sample is added to the element, endogenous analyte competes with the labeled hapten for the binding sites of the immobilized antibody; equilibrium is reached in 4-12 min. Because of the relative liquid-holding capacities of the layers and the grid, only a small amount of the free components remains in the signal layer. The signal is measured by front-surface fluorimetry. This technology has been applied to theophylline and thyroxin assays. Within- and between-run CVs range from 3% to 6%. Comparisons with fluorescent polarization immunoassays (Abbott TDx) showed excellent correlation (theophylline: r = 0.98, slope = 1.07, intercept = 0.3; thyroxin: r = 0.97, slope = 0.91, intercept = 0.8). The new method requires only one pipetting step (sample delivery) and is potentially applicable to a wide range of analytes.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Grenner G,Inbar S,Meneghini FA,Long EW,Yamartino EJ Jr,Bowen MS,Blackwood JJ,Padilla AJ,Maretsky D,Staedter M

subject

Has Abstract

pub_date

1989-09-01 00:00:00

pages

1865-8

issue

9

eissn

0009-9147

issn

1530-8561

journal_volume

35

pub_type

杂志文章
  • Immunoluminometric assay for measurement of the C-terminal endothelin-1 precursor fragment in human plasma.

    abstract:BACKGROUND:Endothelin-1 (ET-1), a potent vasoconstrictor, is difficult to measure because of its instability and its binding to receptors and plasma proteins. We report a rapid, robust way to indirectly quantify ET-1 release by measuring the C-terminal ET-1 precursor fragment (CT-proET-1) without an extraction step. M...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065581

    authors: Papassotiriou J,Morgenthaler NG,Struck J,Alonso C,Bergmann A

    更新日期:2006-06-01 00:00:00

  • Effects of serum-isolated vs synthetic bilirubin-albumin complexes on dye-binding methods for estimating serum albumin.

    abstract::Bush and Reed reported (Clin Chem 1987;33:821-3) that the reaction of albumin with bromcresol purple but not with bromcresol green underestimated the concentration of albumin in synthetically obtained bilirubin-albumin (Bd) by 29%. Their unproven assumption was that chemically synthesized Bd behaved in a manner indist...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ihara H,Nakamura H,Aoki Y,Aoki T,Yoshida M

    更新日期:1991-07-01 00:00:00

  • A comprehensive assay for CFTR mutational analysis using next-generation sequencing.

    abstract:BACKGROUND:Cystic fibrosis is a life-threatening genetic disorder that has been associated with mutations in the CFTR [cystic fibrosis transmembrane conductance regulator (ATP-binding cassette sub-family C, member 7)] gene. Hundreds of CFTR mutations have been detected to date. Current CFTR genotyping assays target a s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.206466

    authors: Abou Tayoun AN,Tunkey CD,Pugh TJ,Ross T,Shah M,Lee CC,Harkins TT,Wells WA,Tafe LJ,Amos CI,Tsongalis GJ

    更新日期:2013-10-01 00:00:00

  • Comparison of countercurrent immunoelectrophoretic assay with commercial radioimmunoassay kits for measuring prostatic acid phosphatase.

    abstract::We evaluated and compared five commercial radioimmunoassay kits with a standard counter-immunoelectrophoretic assay for the measurement of prostatic acid phosphatase in serum. Four of the five radioimmunoassays performed as described by the supplier with respect to sensitivity, stability, precision, linearity, analyti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wright GL Jr,Schellhammer PF,Brassil DN,Sieg SM,Leffell MS

    更新日期:1981-10-01 00:00:00

  • An "oncometer" of clinical measurement of colloid osmotic pressure of plasma.

    abstract::Measurement of colloid osmotic pressure complements measurements of pulmonary artery wedge pressure for assessing the risks of pulmonary edema and constitutes an increasingly important reference for purposes of guiding selection of colloid or crystalloid fluids in patients with acute cardiac disease. We describe a sim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bisera J,Weil MH,Michaels S,Bernardo A,Stein B

    更新日期:1978-09-01 00:00:00

  • Immunoassay of low concentrations of albumin in urine by latex particle counting.

    abstract::We describe here a nonisotopic immunoassay, based on particle-counting technology, for the determination of urinary albumin. The assay takes only 35 min and has been fully automated on the IMPACT (Acade Diagnostic Systems, Brussels, Belgium) machine. The system measures albumin within a linear range between 6.25 and 5...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cambiaso CL,Collet-Cassart D,Lievens M

    更新日期:1988-02-01 00:00:00

  • Use of a synthetic soluble bilirubin derivative to assess interference in creatinine measurements.

    abstract::In assessing interference from bilirubin, the use of a synthetic soluble derivative (ditaurobilirubin, DTB) is recommended as a surrogate for the natural conjugates (Bc). We compared the interference effect of unconjugated bilirubin (Bu), Bc, and DTB, using six mechanized methods for serum creatinine measurement. No s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Franzini C,Morelli AM,Cattozzo G

    更新日期:1991-02-01 00:00:00

  • Gas-chromatographic analysis for 1,2:5,6-dianhydrogalactitol, an anti-neoplastic agent, in plasma.

    abstract::We describe a gas chromatographic method for measuring submicrogram quantities of dianhydrogalactitol, a promising antineoplastic agent (currently undergoing clinical trials in humans), in plasma. The drug is first extracted from blood plasma by saturating the aqueous phase with solid potassium carbonate and extractin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kimura T,Sternson LA,Higuchi T

    更新日期:1976-10-01 00:00:00

  • Comparison of 11 human insulin assays: implications for clinical investigation and research.

    abstract:BACKGROUND:The American Diabetes Association task force on standardization of insulin assays in 1996 showed wide variation in assay bias. Newer assays are specific for insulin, with several now available on automated immunoassay analyzers. METHODS:In 2004, we compared 11 commercially available insulin assays by analyz...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2006.077784

    authors: Manley SE,Stratton IM,Clark PM,Luzio SD

    更新日期:2007-05-01 00:00:00

  • Polymorphisms within the protein tyrosine phosphatase 1B (PTPN1) gene promoter: functional characterization and association with type 2 diabetes and related metabolic traits.

    abstract:BACKGROUND:Protein tyrosine phosphatase 1B (PTPN1) dephosphorylates insulin receptors and attenuates insulin signaling. Polymorphisms in the coding sequence of PTPN1 have been variably associated with type 2 diabetes (T2D). We hypothesized that variations within the PTPN1 promoter might contribute to the development of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.088146

    authors: Meshkani R,Taghikhani M,Al-Kateb H,Larijani B,Khatami S,Sidiropoulos GK,Hegele RA,Adeli K

    更新日期:2007-09-01 00:00:00

  • Serum prostate-specific acid phosphatase: development and validation of a specific radioimmunoassay.

    abstract::We describe radioimmunoassay for human prostatic acid phosphatase [orthophosphoric-monoester phospho-hydrolase (acid optimum), EC 3.1.3.2] in serum, with use of monospecific antisera raised in rabbits against highly purified acid phosphatase from human prostates. The antiserum did not cross react with partly purified ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vihko P,Sajanti E,Jänne O,Peltonen L,Vihko R

    更新日期:1978-11-01 00:00:00

  • Immobilized-enzyme rate-determination method for glucose analysis.

    abstract::We present a rate-determination method for analyzing glucose. A glucose enzyme electrode serves as the sensor and is made by placing a gel-immobilized layer of glucose oxidase over the tip of a Clark-type O2 electrode. The electrode membrane is made of Teflon and is derivatized by etching with a suspension of colloida...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sokol L,Garber C,Shults M,Updike S

    更新日期:1980-01-01 00:00:00

  • Radial-immunodiffusion assay of human apolipoprotein A-I with use of two monoclonal antibodies combined.

    abstract::We produced and characterized several monoclonal antibodies directed toward human plasma apolipoprotein A-I. Two of them, A-I-12 and A-I-57, individually precipitated purified or native high-density lipoprotein in agarose gel by double immunodiffusion. Because radial immunodiffusion performed with a single monoclonal ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Marcovina S,Di Cola G,Catapano AL

    更新日期:1986-12-01 00:00:00

  • Delivering clinical laboratory services to intensive care units.

    abstract::In response to the pressures of cost reduction, we established and evaluated a carefully integrated program to deliver clinical laboratory services more promptly and efficiently to the intensive care units (ICUs). The new protocol reduced the steps and turnaround time from ordering tests by physicians to reporting res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Steffes MW,Gillen JL,Fuhrman SA

    更新日期:1996-03-01 00:00:00

  • Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement.

    abstract:BACKGROUND:Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.118000

    authors: Campbell DJ,Nussberger J,Stowasser M,Danser AH,Morganti A,Frandsen E,Ménard J

    更新日期:2009-05-01 00:00:00

  • RNA chip: quality assessment of RNA by microchannel linear gel electrophoresis in injection-molded plastic chips.

    abstract::Two major components of rRNA (18S and 28S rRNA) were separated by electrophoresis in injection-molded acrylic chips with a microchannel 100 microm in width, 40 microm in depth, and with 1 cm of separation distance. Microchannels were filled with 4 g/L hydroxypropylmethylcellulose as sieving polymer and 5 mg/L ethidium...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ogura M,Agata Y,Watanabe K,McCormick RM,Hamaguchi Y,Aso Y,Mitsuhashi M

    更新日期:1998-11-01 00:00:00

  • Bilirubin binding by primary sites of human serum albumin, with suppression of secondary-site interference by use of a high salt concentration.

    abstract::A high (2.0 mol/L) NaCl concentration apparently suppresses the secondary-site binding of bilirubin by human serum albumin. Thus if an excess of bilirubin is added to human serum albumin or to neonatal serum in buffer containing 0.1 mol of tris(hydroxymethyl)aminomethane and 2.0 mol of NaCl per liter (pH 7.5), and the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rutkowski RB

    更新日期:1980-01-01 00:00:00

  • Serum erythropoietin concentrations and iron status in patients on chronic hemodialysis.

    abstract::We studied the relationship between serum erythropoietin (EPO) concentration and iron status in 67 patients undergoing chronic hemodialysis. Serum concentrations of EPO were measured by RIA with recombinant human EPO. The geometric mean of the serum EPO concentration was 10.9 int. units/L (mean +/- SD range = 7.8 - 15...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Seguchi C,Shima T,Misaki M,Takarada Y,Okazaki T

    更新日期:1992-02-01 00:00:00

  • Evaluation of the dual-precipitation method by comparison with the ultracentrifugation method for measurement of lipoproteins in serum.

    abstract::We evaluated the dual-precipitation method for quantitative measurement of lipoproteins as described by Wilson and Spiger [J. Lab. Clin. Med. 82, 473 (1973)] for normo- and hyperlipemic sera, by comparison with the results obtained with ultracentrifugation. If serum with an above-normal triglyceride concentration is a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Demacker PN,Vos-Janssen HE,Jansen AP,van 't Laar A

    更新日期:1977-07-01 00:00:00

  • Noninvasive Detection of Cocaine and Heroin Use with Single Fingerprints: Determination of an Environmental Cutoff.

    abstract:BACKGROUND:Recent publications have explored the possibility of using fingerprints to confirm drug use, but none has yet dealt with environmental contamination from fingertips. Here we explored the possibility of establishing an environmental cutoff for drug testing from a single fingerprint. METHODS:Fingerprint sampl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.281469

    authors: Ismail M,Stevenson D,Costa C,Webb R,de Puit M,Bailey M

    更新日期:2018-06-01 00:00:00

  • Inhibitory effects of micronized fenofibrate on carotid atherosclerosis in patients with essential hypertension.

    abstract:BACKGROUND:The coexistence of hypertension and dyslipidemia synergistically increases the risk of cardiovascular events. We investigated the effect of the lipid-lowering agent micronized fenofibrate on inhibition of carotid atherosclerosis in patients with essential hypertension and mild hyperlipidemia. METHODS:We mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.074724

    authors: Zhu S,Su G,Meng QH

    更新日期:2006-11-01 00:00:00

  • Detection of Chromosomal Translocation in Hematologic Malignancies by a Novel DNA-Based Looped Ligation Assay (LOLA).

    abstract:BACKGROUND:Disease-defining chromosomal translocations are seen in various neoplasms, especially in lymphomas and leukemias. Translocation detection at the DNA level is often complicated by chromosomal breakpoints that are distributed over very large regions. We have developed a ligation-based assay [the looped ligatio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.270140

    authors: Harada S,Sizzle E,Lin MT,Gocke CD

    更新日期:2017-07-01 00:00:00

  • Automated creatine kinase-MB estimation by immuno-inhibition: a clinical evaluation.

    abstract::We detected the presence of creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in serum by using an immunoinhibition technique to inactivate the creatine kinase isoenzyme of muscle origin (CK-MM). The GEMSAEC centrifugal analyzer is ideally suited for this procedure because it rapidly mixes reagents and has a throughpu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delahunty TJ,Foreback CC

    更新日期:1980-04-01 00:00:00

  • Interference in a chromogenic alpha-amylase assay caused by dye-labeled oligosaccharide-induced precipitation of lipoprotein.

    abstract::We examined the mechanism by which hypertriglyceridemia interferes with the Roche Diagnostics "Amylochrome" procedure for measurement of amylase in lactescent samples with normal and above-normal amylase activity. The serum blank recommended in the Amylochrome protocol to compensate for lactescence remains inappropria...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wickus GG,Dukerschein RO,Pierce JR,Davis KD

    更新日期:1982-10-01 00:00:00

  • A kinetic standard for precise calibration of spectrophotometer cell temperature.

    abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adams PA,Berman MC

    更新日期:1981-05-01 00:00:00

  • Thyroid hormone contamination in crystalline diiodotyrosine.

    abstract::Crystalline preparations of diiodotyrosine contain trace quantities of thyroxine that can be detected by several competitive radioassays and by chromatography on Sephadex. Spontaneous coupling of diiodotyrosine to thyroxine during iodination of tyrosine and coprecipitation of hormone with diiodotyrosine crystals are l...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Alexander NM,Nishimoto M

    更新日期:1978-10-01 00:00:00

  • Genetic variants in the fibroblast growth factor pathway as potential markers of ovarian cancer risk, therapeutic response, and clinical outcome.

    abstract:BACKGROUND:The fibroblast growth factor (FGF) and FGF receptor (FGFR) axis plays a critical role in tumorigenesis, but little is known of its influence in ovarian cancer. We sought to determine the association of genetic variants in the FGF pathway with risk, therapeutic response, and survival of patients with ovarian ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.211490

    authors: Meng QH,Xu E,Hildebrandt MA,Liang D,Lu K,Ye Y,Wagar EA,Wu X

    更新日期:2014-01-01 00:00:00

  • Meaning of serum free-thyroxin values in nonthyroidal illnesses: seven methods compared.

    abstract::Serum free thyroxin (FT4) was determined in 40 patients with various nonthyroidal illnesses. We studied seven methods: (1) a free thyroxin index calculated from total T4 and triiodothyronine resin uptake; (2) a free T4 index determined by enzyme inhibitor assays (Abbott's "Tetrazyme" and "Thyrozyme"); (3) a free T4 in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chan DW,Waud JM,Taylor E,Stem J,Drew H,Oropeza M,Sucupira MS

    更新日期:1983-12-01 00:00:00

  • Potential application of ELAVL4 real-time quantitative reverse transcription-PCR for detection of disseminated neuroblastoma cells.

    abstract:BACKGROUND:Reliable detection of neuroblastoma cells in bone marrow (BM) is critical because BM involvement influences staging, risk assessment, and evaluation of therapeutic response in neuroblastoma patients. Standard cytomorphologic examination of BM aspirates is sensitive enough to detect single tumor cells. Conseq...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.059485

    authors: Swerts K,De Moerloose B,Dhooge C,Vandesompele J,Hoyoux C,Beiske K,Benoit Y,Laureys G,Philippé J

    更新日期:2006-03-01 00:00:00

  • Fast lipoprotein chromatography: new method of analysis for plasma lipoproteins.

    abstract::Fast lipoprotein chromatography (FLPC) is a novel method for quantifying lipoproteins. Plasma proteins are separated by fast-flow gel filtration. Lipoproteins are detected by post-column derivatization with an enzymatic cholesterol reagent. FLPC resolves very-low-, low-, and high-density lipoproteins (VLDL, LDL, and H...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: März W,Siekmeier R,Scharnagl H,Seiffert UB,Gross W

    更新日期:1993-11-01 00:00:00