High-dose alpha-tocopherol therapy does not affect HDL subfractions in patients with coronary artery disease on statin therapy.

Abstract:

BACKGROUND:Subfractions of HDL, particularly large HDL (HDL2), are inversely correlated with the severity of coronary artery disease (CAD). alpha-Tocopherol (AT) is the main lipid-soluble antioxidant in plasma. Results of a previous small study (n = 44) suggested that either a combination of an antioxidant cocktail [800 IU/day 2R,4'R,8'R-(RRR)-AT plus 1 g vitamin C, 25 mg beta-carotene, and 100 microg selenium] or individual antioxidant vitamins combined with simvastatin-niacin (S-N) therapy attenuated the protective increase in HDL2 seen with S-N alone. Few data are available on the effect of AT therapy alone on HDL subfractions, which we addressed in this study. METHODS:In a prospective placebo-controlled study, we randomized 127 patients with stable CAD to receive high-dose RRR-AT (1200 IU/day for 2 years) or placebo. HDL subfractions (small, medium, and large HDL particles) were analyzed by nuclear magnetic resonance spectroscopy. RESULTS:AT concentrations significantly increased in the AT arm but not with placebo. No differences were noted between AT and placebo groups in concentrations of total cholesterol, triglyceride, LDL-cholesterol, or HDL-cholesterol. AT therapy did not affect total, small, medium, or large HDL particles compared with baseline or placebo. Furthermore, serum apolipoprotein A1 concentrations did not change after 2 years AT therapy as compared with baseline. CONCLUSIONS:High-dose AT therapy administered for a 2-year period does not negatively affect either HDL subfractions or apolipoprotein A1 in patients with CAD on statin therapy. Thus the negative interaction previously proposed between antioxidant cocktail and statin therapy cannot be attributed to AT.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Singh U,Otvos J,Dasgupta A,de Lemos JA,Devaraj S,Jialal I

doi

10.1373/clinchem.2006.078865

subject

Has Abstract

pub_date

2007-03-01 00:00:00

pages

525-8

issue

3

eissn

0009-9147

issn

1530-8561

pii

clinchem.2006.078865

journal_volume

53

pub_type

杂志文章,随机对照试验
  • Diagnosis of 5α-reductase 2 deficiency: is measurement of dihydrotestosterone essential?

    abstract:BACKGROUND:5α-Reductase 2 deficiency (5ARD) is a known cause of 46,XY disorders of sex development (DSD). Traditionally, the diagnosis relies on dihydrotestosterone (DHT) measurement, but the results are often equivocal, potentially leading to misdiagnosis. We reviewed alternative approaches for diagnosis of 5ARD. MET...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2012.196501

    authors: Chan AO,But BW,Lee CY,Lam YY,Ng KL,Tung JY,Kwan EY,Chan YK,Tsui TK,Lam AL,Tse WY,Cheung PT,Shek CC

    更新日期:2013-05-01 00:00:00

  • Variability of plasma lipids and lipoproteins: the Jerusalem Lipid Research Clinic Study.

    abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friedlander Y,Kark JD,Stein Y

    更新日期:1985-07-01 00:00:00

  • C-reactive protein uptake by macrophage cell line via class-A scavenger receptor.

    abstract:BACKGROUND:C-reactive protein (CRP) increases in response to inflammation and is purported to be a risk factor for atherogenesis. We recently demonstrated that a scavenger receptor, lectin-like oxidized LDL receptor (LOX-1), is a receptor for CRP. In light of the overlapping ligand spectrum of scavenger receptors such ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140202

    authors: Fujita Y,Kakino A,Harada-Shiba M,Sato Y,Otsui K,Yoshimoto R,Sawamura T

    更新日期:2010-03-01 00:00:00

  • Liquid-chromatographic measurement of taurine in cerebrospinal fluid of normal individuals and patients with meningitis.

    abstract::Taurine was measured in cerebrospinal fluid by reacting it with fluorescamine to form a fluorescent derivative, followed by separation on a reversed-phase column and fluorometric detection and evaluation. The assay is rapid (17 min) and sensitive to as little as 1 mumol/L. The mean value for 27 cerebrospinal fluid sam...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shihabi ZK,White JP

    更新日期:1979-08-01 00:00:00

  • Simultaneous measurement of serum testosterone and dihydrotestosterone by liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Recent reports have described inherent problems with androgen immunoassays compared with mass spectrometry analyses. METHODS:We developed a method for measuring serum testosterone (T) and 5alpha-dihydrotestosterone (DHT) simultaneously via liquid-liquid extraction followed by liquid chromatography-tandem ma...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.103846

    authors: Shiraishi S,Lee PW,Leung A,Goh VH,Swerdloff RS,Wang C

    更新日期:2008-11-01 00:00:00

  • Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration.

    abstract:BACKGROUND:Recent recognition of its broad pathophysiological importance has triggered an increased interest in 25-hydroxyvitamin D [25(OH)D]. By consequence, throughput in 25(OH)D testing has become an issue for clinical laboratories, and several automated assays for measurement of 25(OH)D are now available. The aim o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.176545

    authors: Heijboer AC,Blankenstein MA,Kema IP,Buijs MM

    更新日期:2012-03-01 00:00:00

  • Diagnostic accuracy of pancreatic enzymes evaluated by use of multivariate data analysis.

    abstract::We analyzed pancreatic enzyme data from 508 patients with suspected pancreatitis by neural network analysis, by an Expert multirule generation protocol, and by receiver-operator characteristic (ROC) curve analysis of a single test result. Neural network analysis showed that use of lipase provided the best means for di...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kazmierczak SC,Catrou PG,Van Lente F

    更新日期:1993-09-01 00:00:00

  • Sensitive and selective liquid-chromatographic assay of fluoxetine and norfluoxetine in plasma with fluorescence detection after precolumn derivatization.

    abstract::We determined fluoxetine (Prozac) and its major metabolite norfluoxetine in plasma by liquid chromatography with fluorescence detection. After liquid-liquid extraction from 1 mL of plasma, the extract was derivatized at room temperature with dansyl chloride, and the highly fluorescent derivatives were chromatographed ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suckow RF,Zhang MF,Cooper TB

    更新日期:1992-09-01 00:00:00

  • Lipoprotein(a) and cardiovascular disease in ethnic Chinese: the Chin-Shan Community Cardiovascular Cohort Study.

    abstract:BACKGROUND:Little is known about lipoprotein(a) [Lp(a)] as a predictor of vascular events among ethnic Chinese. We prospectively investigated the association of Lp(a) with cardiovascular disease and all-cause death in a community-based cohort. METHODS:We conducted a community-based prospective cohort study of 3484 par...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.090969

    authors: Chien KL,Hsu HC,Su TC,Sung FC,Chen MF,Lee YT

    更新日期:2008-02-01 00:00:00

  • Lack of comparability of intact parathyroid hormone measurements among commercial assays for end-stage renal disease patients: implication for treatment decisions.

    abstract:BACKGROUND:Variability among assays used to measure intact parathyroid hormone (iPTH) is of particular concern because of the routine use of iPTH assay results to guide management of osteodystrophy and calcium metabolism in patients with end-stage renal disease (ESRD). The aim of this study was to determine the extent ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.071589

    authors: Cantor T,Yang Z,Caraiani N,Ilamathi E

    更新日期:2006-09-01 00:00:00

  • Inadequate hemolysis of erythrocytes on reagent strips at low pH causes false-negative readings.

    abstract::Patients' urines gave an unexpectedly high percentage of false-negative results for erythrocytes on a reagent strip, even when the test field for ascorbic acid indicated that none of this substance was present to inhibit the test reaction. By adding known amounts of erythrocytes to normal urines, we found that this ph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levin K,Engström I

    更新日期:1984-11-01 00:00:00

  • Energy-dispersive x-ray fluorescence spectroscopy and inductively coupled plasma emission spectrometry evaluated for multielement analysis in complex biological matrices.

    abstract::Energy-dispersive x-ray spectroscopy and inductively coupled plasma emission spectrometry were evaluated as methods for routine multielement analysis of biological material. Standard samples included Standard Reference Materials (National Bureau of Standards), compounded mixtures, and supplements that provided a wide ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Irons RD,Schenk EA,Giauque RD

    更新日期:1976-12-01 00:00:00

  • Bias in sensitivity and specificity caused by data-driven selection of optimal cutoff values: mechanisms, magnitude, and solutions.

    abstract:BACKGROUND:Optimal cutoff values for tests results involving continuous variables are often derived in a data-driven way. This approach, however, may lead to overly optimistic measures of diagnostic accuracy. We evaluated the magnitude of the bias in sensitivity and specificity associated with data-driven selection of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.096032

    authors: Leeflang MM,Moons KG,Reitsma JB,Zwinderman AH

    更新日期:2008-04-01 00:00:00

  • Mitochondrial aspartate aminotransferase determined by "Fast Protein Liquid Chromatography".

    abstract::We describe an improved separation of the isoenzymes of aspartate aminotransferase (EC 2.6.1.1), based on ion-exchange chromatography. Involving the "Fast Protein Liquid Chromatography" system (Pharmacia) with a MonoQ column, this rapid, reproducible method for quantifying the mitochondrial enzyme shows good resolutio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Grøstad M,Rej R,Huseby NE

    更新日期:1990-02-01 00:00:00

  • Molecular diagnosis of medium-chain acyl-CoA dehydrogenase deficiency by oligonucleotide ligation assay.

    abstract::Medium-chain acyl-CoA dehydrogenase (MCAD) deficiency is a recessively inherited defect in the mitochondrial beta-oxidation of fatty acids. A single nucleotide change, the A985 --> G transition, in the MCAD gene accounts for approximately 90% of all the disease-causing mutations in the patients. We have used PCR to am...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Romppanen EL,Mononen T,Mononen I

    更新日期:1998-01-01 00:00:00

  • Detection of heterozygotes for phenylketonuria by constant intravenous infusion of L-phenylalanine.

    abstract::We measured the rate of elimination of phenylalanine by constant intravenous infusion of L-phenylalanine in 14 parents of children with phenylketonuria and in 21 subjects with a negative family history for this disease. When reciprocals of the observed elimination rates were plotted against the reciprocals of the incr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jagenburg R,Rödjer S

    更新日期:1977-09-01 00:00:00

  • Improved column-chromatographic isolation of glycosylated hemoglobin S.

    abstract::We investigated glycosylated hemoglobin S by means of chromatography on Bio-Rex 70. The selected elution conditions were similar to those described by Trivelli et al. (N Engl J Med 284: 353-357, 1971), except for modified ionic strength and accurate temperature control. This enabled us to isolate a minor hemoglobin fr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cirotto C,Allegrucci M,Cartechini MG,Compagnucci P,Santeusanio F,Bolli G

    更新日期:1985-04-01 00:00:00

  • Disease-related metabolites in culture medium of fibroblasts from patients with D-2-hydroxyglutaric aciduria, L-2-hydroxyglutaric aciduria, and combined D/L-2-hydroxyglutaric aciduria.

    abstract:BACKGROUND:D-2-Hydroxyglutaric aciduria (D-2-HGA), L-2-hydroxyglutaric aciduria (L-2-HGA), and the combined D/L-2-hydroxyglutaric aciduria (D/L-2-HGA) are poorly understood organic acidurias. To investigate the usefulness of cultured human skin fibroblasts for both diagnostic and research purposes, we measured disease-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.7.1133

    authors: Struys EA,Verhoeven NM,Roos B,Jakobs C

    更新日期:2003-07-01 00:00:00

  • Immunofluorometric demonstration and quantification of placental protein 5 in the absence of pregnancy.

    abstract::This time-resolved immunofluorometric assay (IFMA) developed for measurement of placental protein 5 (PP5) involves two antibodies: a monoclonal anti-PP5 antibody attached to a solid phase and an europium(III) chelate-labeled polyclonal anti-PP5 antibody as a tracer. The measuring range is 0.05-100 micrograms/L and the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bützow R,Alfthan H,Stenman UH,Suikkari AM,Bohn H,Seppälä M

    更新日期:1988-08-01 00:00:00

  • Development of a marker of estrogenic exposure in human serum.

    abstract::The deleterious, disruptive effects of estrogen mimics on the endocrine system were discovered after the compounds were released into the environment. Their chemical structure does not obviously resemble that of steroid hormones; hence, their estrogenic effects were totally unexpected. In addition to occupational expo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sonnenschein C,Soto AM,Fernandez MF,Olea N,Olea-Serrano MF,Ruiz-Lopez MD

    更新日期:1995-12-01 00:00:00

  • A tandem mass spectrometry triplex assay for the detection of Fabry, Pompe, and mucopolysaccharidosis-I (Hurler).

    abstract:BACKGROUND:We sought to develop a tandem mass spectrometry assay in which the enzymatic activities of 3 lysosomal enzymes (α-glucosidase, α-galactosidase A, and α-l-iduronidase) could be quantified in dried blood spots by using a single assay buffer. METHODS:A 3-mm dried blood spot punch was incubated in a single assa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.152009

    authors: Duffey TA,Bellamy G,Elliott S,Fox AC,Glass M,Turecek F,Gelb MH,Scott CR

    更新日期:2010-12-01 00:00:00

  • Cholesterol and risk of coronary heart disease and mortality in men.

    abstract::Extensive data implicate cholesterol in the atherosclerotic process responsible for coronary disease. Of the atherosclerotic disease outcomes, serum cholesterol is most strongly related to coronary disease. A significant relationship of serum cholesterol to all clinical manifestations of coronary heart disease has bee...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Kannel WB

    更新日期:1988-01-01 00:00:00

  • Comparison of calculated and measured free thyroid hormones in serum in health and in abnormal states.

    abstract::To evaluate a theoretical model for calculating free thyroid hormones, based on the law of mass action, we compared values for both calculated and measured free thyroxin and free triiodothyronine in a group of normal subjects. To determine whether the concentrations of circulating free hormones were also predictable f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fresco G,Curti G,Biggi A,Fontana B

    更新日期:1982-06-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Radioimmunoassay of cortisone in serum, urine, and saliva to assess the status of the cortisol-cortisone shuttle.

    abstract::We have developed a new assay for cortisone (E) in serum, saliva, and urine involving Celite chromatography followed by RIA with 125I-labeled E and scintillation proximity assay. The chromatography step separates cortisol (F) from E, and in combination with their RIAs, permits assessment of the status of the F-E shutt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morineau G,Boudi A,Barka A,Gourmelen M,Degeilh F,Hardy N,al-Halnak A,Soliman H,Gosling JP,Julien R,Brerault JL,Boudou P,Aubert P,Villette JM,Pruna A,Galons H,Fiet J

    更新日期:1997-08-01 00:00:00

  • Cross reactivity of digitoxin and spironolactone in two radioimmunoassays for serum digoxin.

    abstract::We measured the cross reactivity of two medications--digitoxin and spironolactone--in two digoxin radioimmunoassay (liquid and solid-phase) kit procedures. Both tests showed similar average percentages of cross reactivity with digitoxin (7.2 and 8.9% for intravenous, and 11.9 and 10.9% for oral administration), but no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Müller H,Bräuer H,Resch B

    更新日期:1978-04-01 00:00:00

  • Gas-chromatographic measurement of carboxyhemoglobin in blood from mothers and newborns.

    abstract::HbCO in blood sampled from 20 mothers and newborns immediately after birth was measured with a new, simple gas-chromatographic method for CO. The mean ratio of HbCO to total hemoglobin for 13 non-smoking mothers did not differ significantly from that for their infants (mean 0.38%, SD 0.26% vs 0.38%, SD 0.13%), but the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fogh-Andersen N,Eriksen PS,Grinsted J,Siggaard-Andersen O

    更新日期:1988-01-01 00:00:00

  • A homogeneous method for genotyping with fluorescence polarization.

    abstract::We combined the amplification refractory mutation system (ARMS) and fluorescence polarization (FP) to give a homogeneous genomic DNA genotype analysis method. Oligonucleotide probes labeled with the fluorescein dyes fluorescein isothiocyanate and 5-([4,6-dichlorotriazin-2-yl]amino)fluorescein and the rhodamine dye 6-c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gibson NJ,Gillard HL,Whitcombe D,Ferrie RM,Newton CR,Little S

    更新日期:1997-08-01 00:00:00

  • Polyacrylamide gel electrophoresis in quantification of high-density lipoprotein cholesterol.

    abstract::We evaluated a method for quantifying high-density lipoprotein cholesterol in plasma, based on electrophoretic migration of the prestained (with Sudan Black III) sample through a discontinuous polyacrylamide++ gel and densitometric integration of the stain associated with each class of lipoprotein. With this method, o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Roche D,Atger V,Le Quang NT,Girard A,Ekindjian OG

    更新日期:1985-11-01 00:00:00

  • Analytical performance of Bayer Immuno 1 estradiol and progesterone assays.

    abstract::We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lévesque A,Letellier M,Dillon PW,Grant A