Stiffness evaluation of contacting surfaces by bulk and interface waves.

Abstract:

:This paper describes ultrasonic measurements of normal and tangential stiffnesses of the contacting interface between polished aluminum blocks subjected to nominal contact pressures up to about 3.8 MPa. These stiffnesses were evaluated by ultrasonic spectroscopy methods for the bulk (longitudinal and transverse) wave reflection coefficients and the anti-symmetric mode interface wave velocity. The measurements revealed the interfacial stiffnesses as functions of the frequency as well as the applied contact pressure. The ratio of the tangential and normal stiffnesses is discussed in the light of foregoing theoretical and experimental findings. Furthermore, possible explanations for the frequency dependence of the measured stiffnesses are reviewed, invoking the spatial inhomogeneity of the interfacial stiffness as well as its lossy nature.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Biwa S,Hiraiwa S,Matsumoto E

doi

10.1016/j.ultras.2007.08.005

subject

Has Abstract

pub_date

2007-12-01 00:00:00

pages

123-9

issue

1-4

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(07)00076-5

journal_volume

47

pub_type

杂志文章
  • Rare earth ultrasonic transducer technique research.

    abstract::Transducer is the necessary and most important part in the maxonics. New applications demand for new transducer, and the renovation of the transducer will open a new field for the application of the maxonics. The important method to develop new transducer is to find and develop new material. The rare earth giant magne...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.128

    authors: Liu W,Zhou L,Xia T,Yu H

    更新日期:2006-12-22 00:00:00

  • Research on adaptive temperature control in sound field induced by self-focused concave spherical transducer.

    abstract::Temperature control of hyperthermia treatments is generally implemented with multipoint feedback system comprised of phased-array transducer, which is complicated and high cost. Our simulations to the acoustic field induced by a self-focused concave spherical transducer (0.5MHz, 9cm aperture width, 8.0cm focal length)...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.01.006

    authors: Hu J,Qian S,Ding Y

    更新日期:2010-05-01 00:00:00

  • Inline ultrasonic rheometry by pulsed Doppler.

    abstract::This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.027

    authors: Pfund DM,Greenwood MS,Bamberger JA,Pappas RA

    更新日期:2006-12-22 00:00:00

  • Excitation and detection of evanescent acoustic waves in piezoelectric plates: Theoretical and 2D FEM modeling.

    abstract::This paper presents the results of the theoretical and 2D FEM modeling excitation and detection of evanescent acoustic waves in piezoelectric plates. By application of 2D ordinary differential equations derived by Auld, we obtained the dispersion curves of A1 and SH1 waves in YX LiNbO3 and YX KNbO3 plates in proximity...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105961

    authors: Kuznetsova I,Nedospasov I,Smirnov A,Qian ZH,Wang B,Dai XY

    更新日期:2019-11-01 00:00:00

  • The quasi-harmonic ultrasonic polar scan for material characterization: experiment and numerical modeling.

    abstract::Conventionally, the ultrasonic polar scan (UPS) records the amplitude or time-of-flight in transmission using short ultrasonic pulses for a wide range of incidence angles, resulting in a fingerprint of the critical bulk wave angles of the material at the insonified spot. Here, we investigate the use of quasi-harmonic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.002

    authors: Kersemans M,Martens A,Van Den Abeele K,Degrieck J,Pyl L,Zastavnik F,Sol H,Van Paepegem W

    更新日期:2015-04-01 00:00:00

  • Interlaboratory evaluation of hydrophone sensitivity calibration from 0.1 to 2 MHz via time delay spectrometry.

    abstract::Knowing the low-frequency response of hydrophones, down to 100 kHz at least, is important for accurate biomedical ultrasound measurements. However, current international standards do not extend below 500 kHz. Furthermore, commercial hydrophone sources typically do not supply sensitivity data below 1-2 MHz. Therefore, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.008

    authors: Harris GR,Gammell PM,Lewin PA,Radulescu EG

    更新日期:2004-04-01 00:00:00

  • Absence of biological damage from prolonged exposure to intravascular ultrasound: a swine model.

    abstract::Ultrasound (US) has been used in IMS II (intravascular US) and CLOTBUST (transcranial US) clinical trials for thrombolysis. During the treatment, in addition to the targeted thrombus, other biological components, such as blood and vessel walls are subjected to long durations of US exposure. In this study we explored e...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.10.004

    authors: Soltani A,Singhal R,Garcia JL,Raju NR

    更新日期:2007-03-01 00:00:00

  • Nitric oxide delivery by ultrasonic cracking: some limitations.

    abstract::Nitric oxide (NO) has been implicated in smooth muscle relaxation. Its use has been widespread in cardiology. Due to the effective scavenging of NO by hemoglobin, however, the drug has to be applied locally or in large quantities, to have the effect desired. We propose the use of encapsulated microbubbles that act as ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.003

    authors: Postema M,Bouakaz A,ten Cate FJ,Schmitz G,de Jong N,van Wamel A

    更新日期:2006-12-22 00:00:00

  • Experimental and numerical investigations of mechanical displacements in surface acoustic wave bounded beams.

    abstract::The present paper studies experimentally and numerically the surface acoustic wave (SAW) field on a piezoelectric substrate generated by interdigital transducers (IDT). On the one hand, mechanical displacements produced by the SAW are measured with the help of a laser Doppler vibrometer. On the other hand, mechanical ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106077

    authors: Weser R,Darinskii AN,Weihnacht M,Schmidt H

    更新日期:2020-08-01 00:00:00

  • Determining sodium diffusion through acoustic impedance measurements using 80 MHz Scanning Acoustic Microscopy: Agarose phantom verification.

    abstract::The purpose of this study is to explore the feasibility of time-dependent acoustic impedance measurement by Scanning Acoustic Microscopy (SAM) for analyzing the sodium diffusion. The purpose is motivated by the fact that sodium monitoring is challenging and still in the area of exploratory analysis despite its biologi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.12.013

    authors: Demirkan I,Unlu MB,Bilen B

    更新日期:2019-04-01 00:00:00

  • Torsional ultrasonic transducer computational design optimization.

    abstract::A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predomina...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.05.001

    authors: Melchor J,Rus G

    更新日期:2014-09-01 00:00:00

  • Improving accuracy of acoustic source localization in anisotropic plates.

    abstract::The acoustic source localization technique for anisotropic plates proposed by the authors in an earlier publication ([1] Kundu et al., 2012) is improved in this paper by adopting some modifications. The improvements are experimentally verified on anisotropic flat and curved composite plates. Difficulties associated wi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.001

    authors: Nakatani H,Kundu T,Takeda N

    更新日期:2014-09-01 00:00:00

  • Development of an ultra-portable echo device connected to USB port.

    abstract::In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.11.009

    authors: Saijo Y,Nitta S,Kobayashi K,Arai H,Nemoto Y

    更新日期:2004-04-01 00:00:00

  • Temperature prediction of ultrasonic vibration-assisted milling.

    abstract::Machining temperature is a key factor in ultrasonic vibration-assisted milling as it can significantly influence tool wear rate and residual thermal stresses. In current study, a physics-based analytical predictive model on machining temperature in ultrasonic vibration-assisted milling is proposed, without resorting t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106212

    authors: Feng Y,Hsu FC,Lu YT,Lin YF,Lin CT,Lin CF,Lu YC,Liang SY

    更新日期:2020-12-01 00:00:00

  • Health monitoring of a composite wingbox structure.

    abstract::This work was devoted to the development of a health monitoring system assigned to aerospace applications. Those applications concerned the detection of damaging impacts and debonding between stiffeners and composite skins, since they are the major causes of in-service damage of aircraft structures. The chosen health ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.058

    authors: Grondel S,Assaad J,Delebarre C,Moulin E

    更新日期:2004-04-01 00:00:00

  • Speckle tracking for multi-dimensional flow estimation.

    abstract::Speckle tracking methods overcome the major limitations of current Doppler methods for flow imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages and limitations of two-dimensional algorithms that use a singl...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00182-1

    authors: Bohs LN,Geiman BJ,Anderson ME,Gebhart SC,Trahey GE

    更新日期:2000-03-01 00:00:00

  • Ultrasonic digital interferometer for investigation of blood clotting.

    abstract::The digital ultrasonic fixed path interferometer designed for testing small amounts of sample was used for the investigation of whole blood coagulation, retraction and clot melting processes. The ultrasound velocity and absorption are determined from the characteristics of an acoustic resonator consisting of an emitte...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(78)90007-0

    authors: Grybauskas P,Kundrotas K,Sukackas V,Yaronis E

    更新日期:1978-01-01 00:00:00

  • A multiscale poromicromechanical approach to wave propagation and attenuation in bone.

    abstract::Ultrasonics is an important diagnostic tool for bone diseases, as it allows for non-invasive assessment of bone tissue quality through mass density-elasticity relationships. The latter are, however, quite complex for fluid-filled porous media, which motivates us to develop a rigorous multiscale poromicrodynamics appro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.12.005

    authors: Morin C,Hellmich C

    更新日期:2014-07-01 00:00:00

  • Three-dimensional modelling of micromachined-ultrasonic-transducer arrays operating in water.

    abstract::We report on the 3-D modelling of periodic arrays of capacitive micromachined ultrasonic transducers (cMUTs) operating in fluid. Specific developments have been performed to model biperiodic transducer arrays and to take into account radiation into any stratified media at the front-side as well as the back-side of the...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.09.006

    authors: Wilm M,Reinhardt A,Laude V,Armati R,Daniau W,Ballandras S

    更新日期:2005-05-01 00:00:00

  • Experimental and numerical study of ultrasonically-assisted drilling.

    abstract::In this study, 3D finite element simulation of ultrasonically-assisted drilling is carried out to analyze the effect of ultrasonic vibrations on common difficulties existed in conventional drilling. Influence of harmonic movement of drill bit on the formation of built-up edge is experimentally evaluated and also discu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.009

    authors: Lotfi M,Amini S

    更新日期:2017-03-01 00:00:00

  • Tandem shock waves to enhance genetic transformation of Aspergillus niger.

    abstract::Filamentous fungi are used in several industries and in academia to produce antibiotics, metabolites, proteins and pharmaceutical compounds. The development of valuable strains usually requires the insertion of recombinant deoxyribonucleic acid; however, the protocols to transfer DNA to fungal cells are highly ineffic...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.003

    authors: Loske AM,Fernández F,Magaña-Ortíz D,Coconi-Linares N,Ortíz-Vázquez E,Gómez-Lim MA

    更新日期:2014-08-01 00:00:00

  • Phonophoresis: an in vivo evaluation using three topical anaesthetic preparations.

    abstract::An electrical sensory perception threshold technique has been developed for use with human volunteers. This technique has been used to reproducibly quantify the effects of three different commercially available topical anaesthetic preparations on superficial sensory cells (nociceptors) in the skin. Low intensities (0....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(90)90075-y

    authors: Williams AR

    更新日期:1990-05-01 00:00:00

  • 100 MHz bandwidth planar laser-generated ultrasound source for hydrophone calibration.

    abstract::High-frequency calibration of hydrophones is becoming increasingly important, both for clinical and scientific applications of ultrasound, and user safety. At present, the calibrations available routinely to the user community extend to 60 MHz. However, hydrophones that can measure beyond this are available, and ultra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106218

    authors: Rajagopal S,Cox BT

    更新日期:2020-12-01 00:00:00

  • A prosthetic aid for a developing blind child.

    abstract::An experimental ultrasonic sonar for use as a sensory aid with blind children is described. Novel signal processing techniques make the aid relatively simple to construct, yet allow many of its parameters to be changed in the field. In particular, the aid has two features, a variable range code and an automatic level...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(79)90010-6

    authors: Boys JT,Strelow ER,Clark GR

    更新日期:1979-01-01 00:00:00

  • Finite element modeling of grain size effects on the ultrasonic microstructural noise backscattering in polycrystalline materials.

    abstract::The correlation between ultrasonic wave propagation and polycrystalline microstructures has significant implications in nondestructive evaluation. An original numerical approach using the finite element method to quantify in both time and frequency domains the ultrasonic noise scattering due to the elastic heterogenei...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.02.008

    authors: Bai X,Tie B,Schmitt JH,Aubry D

    更新日期:2018-07-01 00:00:00

  • Estimation of dispersion curves of water-loaded structures by using approximated acoustic mass.

    abstract::For coupled structures surrounded by heavy fluids, it is difficult to obtain dispersion curves from an eigenvalue analysis, because the external fluid term in the coupled equation includes transcendental functions for frequency and wavenumber. Thus, in this study, the acoustic mass of the external fluid was approximat...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.12.009

    authors: Jung BK,Ryue J,Hong C,Jeong WB,Shin KK

    更新日期:2018-04-01 00:00:00

  • Effects of ultrasonic vibrations in micro-groove turning.

    abstract::Ultrasonic vibration cutting is an efficient cutting process for mechanical micro-machining. This process can generate intricate surface textures with different geometric characteristics. Micro-grooves/micro-channels are among the most frequently encountered micro-structures and, as such, are the focus of this paper. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.12.016

    authors: Zhang C,Guo P,Ehmann KF,Li Y

    更新日期:2016-04-01 00:00:00

  • Investigation of ultrasonic absorption in the MHz frequency range by silicon substrates with a built-in porous silicon layer.

    abstract::The present study is focused on the development and characterization of an innovative substrate to optimize the axial resolution of ultrasonic transducers on a silicon substrate that is dedicated to ultrasound imaging. The substrate must efficiently dampen wave propagation to avoid degradation of the axial resolution ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.01.006

    authors: Lascaud J,Defforge T,Gautier G,Certon D

    更新日期:2019-07-01 00:00:00

  • Generation of microbubbles from hollow cylindrical ultrasonic horn.

    abstract::In this study, we found that microbubbles with diameters of less than 100μm can be easily generated by using a hollow cylindrical ultrasonic horn. Consecutive images of bubbles obtained by using high-speed and high-resolution cameras reveal that a capillary wave is formed on the gas-liquid interface under weak ultraso...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.010

    authors: Makuta T,Suzuki R,Nakao T

    更新日期:2013-01-01 00:00:00

  • SH ultrasonic guided waves for the evaluation of interfacial adhesion.

    abstract::Shear-Horizontally (SH) polarized, ultrasonic, guided wave modes are considered in order to infer changes in the adhesive properties at several interfaces located within an adhesive bond joining two metallic plates. Specific aluminium lap-joint samples were produced, with different adhesive properties at up to four in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.002

    authors: Castaings M

    更新日期:2014-09-01 00:00:00