Torsional ultrasonic transducer computational design optimization.

Abstract:

:A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predominantly governed by the fluid phase of the tissue, the shear stiffness is dependent on the stroma micro-architecture, which is directly affected by those pathologies. However, diagnostic tools to quantify them are currently not well developed. The first contribution is a new typology of design adapted to quasifluids. A second contribution is the procedure for design optimization, for which an analytical estimate of the Robust Probability Of Detection, called RPOD, is presented for use as optimality criteria. The RPOD is formulated probabilistically to maximize the probability of detecting the least possible pathology while minimizing the effect of noise. The resulting optimal transducer has a resonance frequency of 28 kHz.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Melchor J,Rus G

doi

10.1016/j.ultras.2014.05.001

subject

Has Abstract

pub_date

2014-09-01 00:00:00

pages

1950-62

issue

7

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(14)00119-X

journal_volume

54

pub_type

杂志文章
  • Baseline subtraction technique in the frequency-wavenumber domain for high sensitivity damage detection.

    abstract::This paper suggests a method for high-sensitivity damage detection. The method is based on pitch-catch measurements of Lamb waves combined with a baseline subtraction technique in the frequency-wavenumber domain. Small amplitude converted modes, generated during the interaction of propagating waves with damage, can th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.08.010

    authors: McKeon P,Yaacoubi S,Declercq NF,Ramadan S,Yaacoubi WK

    更新日期:2014-02-01 00:00:00

  • In vivo characterization of the aortic wall stress-strain relationship.

    abstract::Arterial stiffness has been shown to be a good indicator of arterial wall disease. However, a single parameter is insufficient to describe the complex stress-strain relationship of a multi-component, non-linear tissue such as the aorta. We therefore propose a new approach to measure the stress-strain relationship loca...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.01.003

    authors: Danpinid A,Luo J,Vappou J,Terdtoon P,Konofagou EE

    更新日期:2010-06-01 00:00:00

  • Ultrasonic measurements on poroelastic slabs: determination of reflection and transmission coefficients and processing for Biot input parameters.

    abstract::Ultrasonic reflection and transmission measurements on saturated, plane-parallel, poroelastic slabs are presented. A data processing technique is proposed to obtain poroelastic parameters from transmission measurements. A special experimental data acquisition and processing technique is applied to minimize the finite ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.006

    authors: Jocker J,Smeulders D

    更新日期:2009-03-01 00:00:00

  • High-intensity ultrasound irradiation promotes the release of extracellular vesicles from C2C12 myotubes.

    abstract::Skeletal muscle is an important secretory organ in mammals, producing myriad chemical mediators ("myokines") with distinct biological action in different tissues, including anti-inflammatory activity. Extracellular vesicles (EVs) have recently been identified as a mode of myokine transport from muscle, facilitating su...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106243

    authors: Maeshige N,Langston PK,Yuan ZM,Kondo H,Fujino H

    更新日期:2021-02-01 00:00:00

  • Verification of surface wave solutions obtained by the reciprocity theorem.

    abstract::Surface wave motions generated by a time-harmonic point load applied at the surface of an isotropic linearly elastic half-space are conventionally solved by the use of integral transform techniques. The inverse transforms, are often complicated and will not always yield closed-form solutions. In this paper expressions...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.05.003

    authors: Phan H,Cho Y,Achenbach JD

    更新日期:2014-09-01 00:00:00

  • 100 MHz bandwidth planar laser-generated ultrasound source for hydrophone calibration.

    abstract::High-frequency calibration of hydrophones is becoming increasingly important, both for clinical and scientific applications of ultrasound, and user safety. At present, the calibrations available routinely to the user community extend to 60 MHz. However, hydrophones that can measure beyond this are available, and ultra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106218

    authors: Rajagopal S,Cox BT

    更新日期:2020-12-01 00:00:00

  • Surface acoustic waves at the vacuum-thermoviscoelastic solid interface.

    abstract::The present investigation concerns the propagation of surface waves at the vacuum-solid interface of a solid which is isotropic and thermoviscoelastic, i.e., for which the effects of heat conductivity need to be taken into account. Calculations show that, in addition to the Rayleigh wave, a thermal surface wave propag...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00017-2

    authors: Deschamps M,Poncelet O,Dilhaire S,Claeys W

    更新日期:2000-07-01 00:00:00

  • Effects of maximum aggregate size on UPV of brick aggregate concrete.

    abstract::Investigation was carried out to study the effects of maximum aggregate size (MAS) (12.5mm, 19.0mm, 25.0mm, 37.5mm, and 50.0mm) on ultrasonic pulse velocity (UPV) of concrete. For investigation, first class bricks were collected and broken to make coarse aggregate. The aggregates were tested for specific gravity, abso...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.006

    authors: Mohammed TU,Mahmood AH

    更新日期:2016-07-01 00:00:00

  • Experimental and numerical investigations of mechanical displacements in surface acoustic wave bounded beams.

    abstract::The present paper studies experimentally and numerically the surface acoustic wave (SAW) field on a piezoelectric substrate generated by interdigital transducers (IDT). On the one hand, mechanical displacements produced by the SAW are measured with the help of a laser Doppler vibrometer. On the other hand, mechanical ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106077

    authors: Weser R,Darinskii AN,Weihnacht M,Schmidt H

    更新日期:2020-08-01 00:00:00

  • Ultrasonic modification of experimental bruising in the guinea-pig pinna.

    abstract::Both pinnae of anaesthetized male guinea-pigs were contused in a reproducible manner and one immediately treated with 0.75 MHz ultrasound at an average therapeutic intensity of 0.61 W cm-2 for a period of 2 min. The lividity and rate of resorption of the rusultant bruises were measured by a photometric method. The res...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(78)90021-5

    authors: Hustler JE,Zarod AP,Williams AR

    更新日期:1978-09-01 00:00:00

  • Sparse signal representation and its applications in ultrasonic NDE.

    abstract::Many sparse signal representation (SSR) algorithms have been developed in the past decade. The advantages of SSR such as compact representations and super resolution lead to the state of the art performance of SSR for processing ultrasonic non-destructive evaluation (NDE) signals. Choosing a suitable SSR algorithm and...

    journal_title:Ultrasonics

    pub_type: 杂志文章,评审

    doi:10.1016/j.ultras.2011.10.001

    authors: Zhang GM,Zhang CZ,Harvey DM

    更新日期:2012-03-01 00:00:00

  • Fluorescence response of human HER2+ cancer- and MCF-12F normal cells to 200MHz ultrasound microbeam stimulation: a preliminary study of membrane permeability variation.

    abstract::Targeted mechanical cell stimulation has been extensively studied for a better understanding of its effect on cellular mechanotransduction signaling pathways and structures by utilizing a variety of mechanical sources. In this work, an ultrasound-driven single cell stimulation method is thus proposed, and a preliminar...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.03.002

    authors: Hwang JY,Lee J,Lee C,Jakob A,Lemor R,Medina-Kauwe LK,Shung KK

    更新日期:2012-09-01 00:00:00

  • Fundamental wave amplitude difference imaging for detection and characterization of embedded cracks.

    abstract::An ultrasonic technique for imaging nonlinear scatterers, such as partially-closed cracks, buried in a medium has been recently proposed. The method called fundamental wave amplitude difference (FAD) consists of a sequence of acquisitions with different subsets of elements for each line of the image. An image revealin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.02.003

    authors: Haupert S,Ohara Y,Carcreff E,Renaud G

    更新日期:2019-07-01 00:00:00

  • Fast beating null strip during the reflection of pulsed Gaussian beams incident at the Rayleigh angle.

    abstract::It is well known that harmonic bounded Gaussian beams undergo a transformation into two bounded beams upon reflection on a solid immersed in a liquid. The effect is known as the Schoch effect and can be found at the Rayleigh angle for thick plates and at the different Lamb angles for thin plates. Here, a study is made...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.205

    authors: Declercq NF

    更新日期:2006-12-22 00:00:00

  • Sparsity-based beamforming to enhance two-dimensional linear-array photoacoustic tomography.

    abstract::In linear-array photoacoustic imaging (PAI), beamforming methods can be used to reconstruct the images. Delay-and-sum (DAS) beamformer is extensively used due to its simple implementation. However, this algorithm results in high level of sidelobes and low resolution. In this paper, it is proposed to form the photoacou...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.03.010

    authors: Paridar R,Mozaffarzadeh M,Periyasamy V,Pramanik M,Mehrmohammadi M,Orooji M

    更新日期:2019-07-01 00:00:00

  • SH wave propagation in magnetic-electric periodically layered plates.

    abstract::In this paper, dispersive behavior and band structure of SH waves in magnetic-electric (ME) periodically layered plate are investigated by the transfer matrix method. Two kinds of unit cell form, one is piezoelectric (PE)/piezomagnetic (PM)/PE, and the other is PM/PE/PM, are considered in detailed. A peculiar case of ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.01.015

    authors: Pang Y,Gao JS,Liu JX

    更新日期:2014-07-01 00:00:00

  • Picosecond acoustics method for measuring the thermodynamical properties of solids and liquids at high pressure and high temperature.

    abstract::Based on the original combination of picosecond acoustics and diamond anvils cell, recent improvements to accurately measure hypersonic sound velocities of liquids and solids under extreme conditions are described. To illustrate the capability of this technique, results are given on the pressure and temperature depend...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.04.011

    authors: Decremps F,Gauthier M,Ayrinhac S,Bove L,Belliard L,Perrin B,Morand M,Le Marchand G,Bergame F,Philippe J

    更新日期:2015-02-01 00:00:00

  • Ultrasonic strain imaging and reconstructive elastography for biological tissue.

    abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.007

    authors: Khaled W,Reichling S,Bruhns OT,Ermert H

    更新日期:2006-12-22 00:00:00

  • Ultrasonic drawing of tungsten wire for incandescent lamps production.

    abstract::An influence of ultrasonic treatment (drawing) on structure, high temperature durability, evaporation and creep behaviours of tungsten single crystal and wires were investigated. A relation of tungsten wires properties with dislocation distribution was determined. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.02.002

    authors: Mordyuk BN,Mordyuk VS,Buryak VV

    更新日期:2004-04-01 00:00:00

  • An adaptive threshold filter for ultrasound signal rejection.

    abstract::The threshold filter is a frequently used technique in ultrasound B-scan to reject the small echoes contributed from backscattering that blur the tissue interface and reduce the image contrast. Note that using the threshold based on one value would simultaneously destroy local waveform features of the reflection echoe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.007

    authors: Tsui PH,Chang CC,Chang CC,Huang NE,Ho MC

    更新日期:2009-05-01 00:00:00

  • Experimental and numerical study of ultrasonically-assisted drilling.

    abstract::In this study, 3D finite element simulation of ultrasonically-assisted drilling is carried out to analyze the effect of ultrasonic vibrations on common difficulties existed in conventional drilling. Influence of harmonic movement of drill bit on the formation of built-up edge is experimentally evaluated and also discu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.009

    authors: Lotfi M,Amini S

    更新日期:2017-03-01 00:00:00

  • Solder joint failure localization of welded joint based on acoustic emission beamforming.

    abstract::A localization approach of welded joint damage is proposed based on acoustic emission (AE) beamforming. In this method, a uniform line array is introduced to detect the AE signal of welded joints in specified area. In order to investigate the influence of fillet and crimping commonly existing in a welded plate structu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.002

    authors: Liu X,Xiao D,Shan Y,Pan Q,He T,Gao Y

    更新日期:2017-02-01 00:00:00

  • Evidence of dissipative and growing nonlinearity in Lamb waves due to stress-relaxation and material degradation in composites.

    abstract::Experimentally observed dissipated nonlinearity in Lamb wave propagation in composites due to stress-relaxation is reported herein. It was found that the stress relaxation in composite is inherently coupled with the second order nonlinear parameter derived from the Lamb wave modes. Due to the combined effect of intern...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.01.002

    authors: Patra S,Ahmed H,Saadatzi M,Banerjee S

    更新日期:2019-07-01 00:00:00

  • How many times should we repeat measuring liver stiffness using shear wave elastography?: 5-repetition versus 10-repetition protocols.

    abstract::The purpose of this study is to evaluate whether a 5-repetition liver stiffness (LS) measurement as the standard protocol of shear wave elastography (SWE) is comparable to a conventional 10-repetition measurement protocol and to identify factors that influence the reliability of the 5-repetition protocol. A total of 3...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.08.005

    authors: Choi SH,Jeong WK,Kim Y,Lim S,Kwon JW,Kim TY,Kim MY,Sohn JH

    更新日期:2016-12-01 00:00:00

  • A novel ultrasonic micro-dissection technique for biomedicine.

    abstract::Molecular techniques are transforming our understanding of cellular function and disease. However, accurate molecular analysis methods will be limited if the input DNA, RNA, or protein is not derived from pure population of cells or is contaminated by the wrong cells. A novel Ultrasonic Vibration Micro-dissection (UVM...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.010

    authors: Sun L,Wang H,Chen L,Liu Y

    更新日期:2006-12-22 00:00:00

  • Temperature prediction of ultrasonic vibration-assisted milling.

    abstract::Machining temperature is a key factor in ultrasonic vibration-assisted milling as it can significantly influence tool wear rate and residual thermal stresses. In current study, a physics-based analytical predictive model on machining temperature in ultrasonic vibration-assisted milling is proposed, without resorting t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106212

    authors: Feng Y,Hsu FC,Lu YT,Lin YF,Lin CT,Lin CF,Lu YC,Liang SY

    更新日期:2020-12-01 00:00:00

  • Investigation of rat bone fracture healing using pulsed 1.5 MHz, 30 mW/cm(2) burst ultrasound--axial distance dependency.

    abstract::This study investigated the effect of LIPUS on fracture healing when fractures were exposed to ultrasound at three axial distances: z=0 mm, 60 mm, and 130 mm. We applied LIPUS to rat fracture at these three axial distances mimicking the exposure condition of human fractures at different depths under the soft tissue. M...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.10.013

    authors: Fung CH,Cheung WH,Pounder NM,de Ana FJ,Harrison A,Leung KS

    更新日期:2014-03-01 00:00:00

  • Detecting broken-wire flaws at multiple locations in the same wire of prestressing strands using guided waves.

    abstract::Broken wires often occur at multiple locations in the same wire of a strand due to the recovery length, which is defined as the length of the wire taking up its full share of the axial load from the break point. The detection of broken-wire flaws at multiple locations along the same wire is investigated using guided w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.003

    authors: Xu J,Wu X,Sun P

    更新日期:2013-01-01 00:00:00

  • Evaluation of crack parameters by a nonlinear frequency-mixing laser ultrasonics method.

    abstract::The local evaluation of several parameters of a crack is realized with a nonlinear laser ultrasonic method. The method is based on the sample excitation by two laser beams, independently intensity modulated at two cyclic frequencies ωH and ωL (ωH≫ωL) and on the detection of nonlinear frequency-mixing ultrasonic compon...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.005

    authors: Mezil S,Chigarev N,Tournat V,Gusev V

    更新日期:2016-07-01 00:00:00

  • A general model of the axle vibration in piezoelectric motors.

    abstract::In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.080

    authors: Iula A,Pappalardo M

    更新日期:2004-04-01 00:00:00