Abstract:
:Both pinnae of anaesthetized male guinea-pigs were contused in a reproducible manner and one immediately treated with 0.75 MHz ultrasound at an average therapeutic intensity of 0.61 W cm-2 for a period of 2 min. The lividity and rate of resorption of the rusultant bruises were measured by a photometric method. The results fell into two distinct classes. In the majority of cases, the bruises formed on the insonated pinnae were significantly less intense and were resorbed at the same rate as their corresponding controls. In the remaining cases, ultrasonic irradiation resulted in an increased initial lividity and a significantly greater rate of resorption.
journal_name
Ultrasonicsjournal_title
Ultrasonicsauthors
Hustler JE,Zarod AP,Williams ARdoi
10.1016/0041-624x(78)90021-5subject
Has Abstractpub_date
1978-09-01 00:00:00pages
223-8issue
5eissn
0041-624Xissn
1874-9968pii
0041-624X(78)90021-5journal_volume
16pub_type
杂志文章相关文献
ULTRASONICS文献大全abstract::The therapeutic benefits of several existing ultrasound-based therapies such as facilitated drug delivery, tumor ablation and thrombolysis derive largely from physical or mechanical effects. In contrast, ultrasound can also trigger various time-dependent biochemical responses in the exposed biological milieu. Several ...
journal_title:Ultrasonics
pub_type: 杂志文章,评审
doi:10.1016/j.ultras.2008.02.002
更新日期:2008-08-01 00:00:00
abstract::In this paper, te edge mode variation is studied with three different methods: the reciprocal work method, already used by Torvik [J. Acoust. Soc. Am. 41 (1967) 346] to model this phenomenon, the S-parameter method and a finite element model that are applied for the first time to the study of the edge resonance. Moreo...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00391-8
更新日期:2003-01-01 00:00:00
abstract::A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predomina...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.05.001
更新日期:2014-09-01 00:00:00
abstract::Traditional rotary corers and sample retrieval mechanisms for planetary drilling suffer from a variety of technical difficulties. A heavy and rigid drillstring must be assembled on-site and deployed with considerable applied preload and torque, and these mechanical loadings are difficult to react in a low gravity envi...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.06.001
更新日期:2011-12-01 00:00:00
abstract::In this study, we present a model study of guided wave dispersion and resonance behavior of an array of piezoelectric plates with arbitrary cross-sections. The objective of this work is to analyze the influence of the geometry of an element of a 1D-array ultrasound transducer on generating multi-resonance frequency so...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2009.08.006
更新日期:2010-03-01 00:00:00
abstract::In this paper, we investigated theoretically and experimentally the effect of the conductivity of the film located in the immediate vicinity of the free side of a piezoelectric resonator based on the PZT ceramics on its characteristics. It is shown that with increasing the conductivity of the film at first the paralle...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2018.09.016
更新日期:2019-04-01 00:00:00
abstract:BACKGROUND:Ultrasound tissue harmonic signal generally provides superior image quality as compared to the linear signal. However, since the generation of the tissue harmonic signal is based on finite amplitude distortion of the propagating waveform, the penetration and the sensitivity in tissue harmonic imaging are mar...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.12.008
更新日期:2011-07-01 00:00:00
abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106291
更新日期:2021-02-01 00:00:00
abstract::The study is aimed to perform dynamic modeling of a part feeder powered by piezoelectric actuation. This part feeder consists mainly of a horizontal platform vibrated by a pair of parallel piezoelectric bimorph beams. Owing to intermittent impacts with the platform, the transported part on the platform is able to marc...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2007.02.002
更新日期:2007-06-01 00:00:00
abstract::Ultrasonic flaw classification in weldment is an active area of research and many artificial intelligence approaches have been applied to automate this process. However, in the industrial applications, the ultrasonic flaw signals are not noise free and automatic intelligent defect classification algorithms show relati...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2018.12.001
更新日期:2019-04-01 00:00:00
abstract::This paper is concerned with the probing of the transversal envelope solitons propagation in circular waveguides when a set of requirements (non-linearity and dispersion) are fulfilled in the waveguide and balanced. The basic idea is to analyze the shape of an acoustic pulse after it has traveled one or few trips thro...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.01.016
更新日期:2014-07-01 00:00:00
abstract::This paper establishes a model evaluating the signal loss of double transmitted acoustic beams through random rough liquid-solid surfaces based on Fresnel approximation and the phase-screen approximation. The numerical solution is replaced with a simple analytical solution through using the exponential substitution ap...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.05.007
更新日期:2011-01-01 00:00:00
abstract::The conventional acoustic nonlinear technique to evaluate the contact acoustic nonlinearity (CAN) at solid-solid contact interfaces (e.g., closed cracks), which uses the through-transmission of normally incident bulk waves, is limited in that access to both the inner and outer surfaces of structures for attaching puls...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.02.008
更新日期:2012-08-01 00:00:00
abstract::In cancellous bone, longitudinal waves often separate into fast and slow waves depending on the alignment of bone trabeculae in the propagation path. This interesting phenomenon becomes an effective tool for the diagnosis of osteoporosis because wave propagation behavior depends on the bone structure. Since the fast w...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.04.011
更新日期:2008-11-01 00:00:00
abstract::Conventionally, the ultrasonic polar scan (UPS) records the amplitude or time-of-flight in transmission using short ultrasonic pulses for a wide range of incidence angles, resulting in a fingerprint of the critical bulk wave angles of the material at the insonified spot. Here, we investigate the use of quasi-harmonic ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.01.002
更新日期:2015-04-01 00:00:00
abstract::The design of a novel, single-axis ultrasonic actuating stage has been proposed. It consists of a movable plate, an edge-driving ultrasonic actuator as an actuating device, and a magnetic Magi encoder as a position sensor. The stage is impelled using a friction-contact mechanism by the ultrasonic actuator with long di...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2007.06.005
更新日期:2007-12-01 00:00:00
abstract::This paper describes an optimization method of the top electrode size for a thin film matrix ultrasonic transducer (M-UT) in the frequency range above 200 MHz. The goal of this work is to design an optimal top electrode size for an M-UT providing the maximal output peak-peak voltage (V(PP)) and the maximal signal-to-n...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.10.018
更新日期:2013-03-01 00:00:00
abstract::In most applications of MEMS the mechanical properties of the used materials are key parameters for the perfect working of the microsystems. Measuring bulk acoustic waves excited in MEMS structures with ultra-short laser pulses is a powerful method for the accurate and non-destructive evaluation as well as for the cha...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.049
更新日期:2004-04-01 00:00:00
abstract:OBJECTIVES:This paper aims to apply median filters for reducing interpolation error and improving the quality of 3D images in a freehand 3D ultrasound (US) system. BACKGROUND AND MOTIVATION:Freehand 3D US imaging has been playing an important role in obtaining the entire 3D impression of tissues and organs. Reconstruc...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2007.11.005
更新日期:2008-07-01 00:00:00
abstract::The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in t...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2009.09.010
更新日期:2010-02-01 00:00:00
abstract::An influence of ultrasonic treatment (drawing) on structure, high temperature durability, evaporation and creep behaviours of tungsten single crystal and wires were investigated. A relation of tungsten wires properties with dislocation distribution was determined. ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.02.002
更新日期:2004-04-01 00:00:00
abstract::A numerical study is presented to show the potential for using vibroacoustic-based experiments to identify elastic material properties of orthotropic cylindrical vessels immersed in fluids. Sensitivity analyses and a simulated inverse problem are shown to quantify the potential for material characterization through th...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.07.004
更新日期:2008-11-01 00:00:00
abstract::Investigation was carried out to study the effects of maximum aggregate size (MAS) (12.5mm, 19.0mm, 25.0mm, 37.5mm, and 50.0mm) on ultrasonic pulse velocity (UPV) of concrete. For investigation, first class bricks were collected and broken to make coarse aggregate. The aggregates were tested for specific gravity, abso...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.04.006
更新日期:2016-07-01 00:00:00
abstract::This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acousti...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.04.001
更新日期:2010-08-01 00:00:00
abstract::Steel-concrete modular construction is increasingly used in nuclear structure construction. Conventional nondestructive testing methods are not able to detect internal concrete defects because the thick concrete wall is covered by steel plates. An ultrasonic guided method is proposed to detect honeycombs and voids aro...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106096
更新日期:2020-04-01 00:00:00
abstract::In medical ultrasound imaging, dynamic range (DR) is defined as the difference between the maximum and minimum values of the displayed signal to display and it is one of the most essential parameters that determine its image quality. Typically, DR is given with a fixed value and adjusted manually by operators, which l...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.09.012
更新日期:2015-02-01 00:00:00
abstract::In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.080
更新日期:2004-04-01 00:00:00
abstract::Spatial dispersion is the variation of wave speed with wavelength. It sets in when the acoustic wavelength approaches the natural scale of length of the medium, which could, for example, be the lattice constant of a crystal, the repeat distance in a superlattice, or the grain size in a granular material. In centrosymm...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.215
更新日期:2006-12-22 00:00:00
abstract::An ultrasonic backscattering model is developed for textured polycrystalline materials with orthotropic or trigonal grains of ellipsoidal shape. The model allows us to simulate realistic microstructures and orthotropic macroscopic material textures resulting from thermomechanical processing for a broad variety of mate...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.02.020
更新日期:2014-09-01 00:00:00
abstract::In general, the design and analysis of ultrasonic motor and motor's control strategy are based on mathematical model. The academic model is widely used in the analysis of traveling wave ultrasonic motor (TWUSM). But the dispersive characteristic of piezoelectric ceramics and other complicated process, such as the fric...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.09.012
更新日期:2014-02-01 00:00:00