A general model of the axle vibration in piezoelectric motors.

Abstract:

:In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center of a rotating traveling wave generator. A piezoelectric membrane, vibrating in a flexural anti-symmetrical mode, or a thick disk, vibrating in a radial anti-symmetrical mode, can be exploited as traveling wave generators. In the first case a bending moment, in the second case a transverse force is applied to the axle. In both cases, if the driving frequency coincides with a resonance frequency of the axle, the axle acts as a resonant displacement amplifier; a continuous slipping takes place between the axle and the rotor, and a torque is transmitted to the rotor. The proposed model is able to describe the axle vibrational behavior when it is excited by a bending moment, by a transverse force, and also when these two excitations are simultaneously applied. The axle is modeled as a four-port system and all its transfer functions, as well as the transversal displacement along the axle at each frequency can be easily computed. Computed results have been compared with experimental measurements carried out on two motor prototypes that exploit as traveling wave generators a membrane and a disk, respectively. A good agreement was obtained by properly taking into account the loading effect of the generator on the axle.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Iula A,Pappalardo M

doi

10.1016/j.ultras.2004.01.080

subject

Has Abstract

pub_date

2004-04-01 00:00:00

pages

291-6

issue

1-9

eissn

0041-624X

issn

1874-9968

pii

S0041624X04000319

journal_volume

42

pub_type

杂志文章
  • Ultrasonic characterization of Cu-Al-Ni single crystals lattice stability in the vicinity of the phase transition.

    abstract::Measurements of elastic constants of the austenite phase when approaching the phase transformation either upon cooling or stressing is of the crucial interest for the shape memory alloy field. Acoustic properties (wave velocity and also attenuation changes) of the Cu-Al-Ni single crystal were investigated in situ duri...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.029

    authors: Landa M,Novák V,Sedlák P,Sittner P

    更新日期:2004-04-01 00:00:00

  • Ultrasonic measurements on poroelastic slabs: determination of reflection and transmission coefficients and processing for Biot input parameters.

    abstract::Ultrasonic reflection and transmission measurements on saturated, plane-parallel, poroelastic slabs are presented. A data processing technique is proposed to obtain poroelastic parameters from transmission measurements. A special experimental data acquisition and processing technique is applied to minimize the finite ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.006

    authors: Jocker J,Smeulders D

    更新日期:2009-03-01 00:00:00

  • Wide bandwidth fiber-optic ultrasound probe in MOMS technology: Preliminary signal processing results.

    abstract::An ultrasonic probe consisting of two optical fiber-based miniaturized transducers for wideband ultrasound emission and detection is employed for the characterization of in vitro biological tissues. In the probe, ultrasound generation is obtained by thermoelastic emission from patterned carbon films in Micro-Opto-Mech...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.024

    authors: Vannacci E,Granchi S,Belsito L,Roncaglia A,Biagi E

    更新日期:2017-03-01 00:00:00

  • Sound field separating on arbitrary surfaces enclosing a sound scatterer based on combined integral equations.

    abstract::To eliminate the limitations of the conventional sound field separation methods which are only applicable to regular surfaces, a sound field separation method based on combined integral equations is proposed to separate sound fields directly in the spatial domain. In virtue of the Helmholtz integral equations for the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.06.007

    authors: Fan Z,Mei D,Yang K,Chen Z

    更新日期:2014-12-01 00:00:00

  • Automatic dynamic range adjustment for ultrasound B-mode imaging.

    abstract::In medical ultrasound imaging, dynamic range (DR) is defined as the difference between the maximum and minimum values of the displayed signal to display and it is one of the most essential parameters that determine its image quality. Typically, DR is given with a fixed value and adjusted manually by operators, which l...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.09.012

    authors: Lee Y,Kang J,Yoo Y

    更新日期:2015-02-01 00:00:00

  • Ultrasonic system for accurate distance measurement in the air.

    abstract::This paper presents a system that accurately measures the distance travelled by ultrasound waves through the air. The simple design of the system and its obtained accuracy provide a tool for non-contact distance measurements required in the laser's optical system that investigates the surface of the eyeball. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.05.011

    authors: Licznerski TJ,Jaroński J,Kosz D

    更新日期:2011-12-01 00:00:00

  • Determination of the material properties of microstructures by laser based ultrasound.

    abstract::In most applications of MEMS the mechanical properties of the used materials are key parameters for the perfect working of the microsystems. Measuring bulk acoustic waves excited in MEMS structures with ultra-short laser pulses is a powerful method for the accurate and non-destructive evaluation as well as for the cha...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.049

    authors: Profunser DM,Vollmann J,Dual J

    更新日期:2004-04-01 00:00:00

  • In vitro chronic hepatic disease characterization with a multiparametric ultrasonic approach.

    abstract::Although, high resolution, real-time ultrasonic (US) imaging is routinely available, image interpretation is based on grey-level and texture and quantitative evaluation is limited. Other potentially useful diagnostic information from US echoes may include modifications in tissue acoustic parameters (speed, attenuation...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.09.002

    authors: Meziri M,Pereira WC,Abdelwahab A,Degott C,Laugier P

    更新日期:2005-03-01 00:00:00

  • Nonlinear surface acoustic waves: realization of solitary pulses and fracture.

    abstract::A laser-based technique for the contact-free generation and detection of strongly nonlinear surface acoustic wave (SAW) pulses with amplitudes limited by the materials strength has been developed. The effects of nonlinear propagation of short elastic surface pulses with finite strength in isotropic solids, such as fus...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.06.002

    authors: Lomonosov AM,Hess P

    更新日期:2008-11-01 00:00:00

  • Axial vibration characteristics of a cylindrical, radially polarized piezoelectric transducer with different electrode patterns.

    abstract::A circular cylindrical piezoelectric transducer with radial polarization is proposed. The axial vibration characteristics of the transducer are studied by three different methods: analytical calculation, FEM simulation and experiment. The symmetric and asymmetric excitation conditions are discussed in the Haskins and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.008

    authors: Sun D,Wang S,Hata S,Shimokohbe A

    更新日期:2010-03-01 00:00:00

  • Fabrication and comparison of PMN-PT single crystal, PZT and PZT-based 1-3 composite ultrasonic transducers for NDE applications.

    abstract::This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acousti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.04.001

    authors: Kim KB,Hsu DK,Ahn B,Kim YG,Barnard DJ

    更新日期:2010-08-01 00:00:00

  • Ultrasonic spectroscopy of pure cyclic compounds.

    abstract::Ultrasonic studies of the group of halogens of benzene and particularly dependence of acoustic parameters on the structure of organic liquids, demonstrate some interesting regularities in the group of these compounds in gas and liquid states. In this paper results for five cyclic liquids: bromo-, chloro-, fluoro- and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.146

    authors: Linde BB,Lezhnev NB

    更新日期:2006-12-22 00:00:00

  • Effect of carrier and particle concentration on ultrasound properties of magnetic nanofluids.

    abstract::Ultrasound wave propagation in nanofluids and its rheological behavior has been studied as a function of solid volume fraction, temperature and magnetic field for magnetic nanofluids synthesized in kerosene and transformer oil. Ultrasonic velocity decreases while viscosity increases with increasing volume fraction. Th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.08.017

    authors: Patel JK,Parekh K

    更新日期:2015-01-01 00:00:00

  • Stability of alteplase in presence of cavitation.

    abstract::Several experimental studies have demonstrated that ultrasound (US) can accelerate enzymatic fibrinolysis and this effect is further enhanced in the presence of ultrasound contrast agents (UCA). Although UCA have been shown to be safe when administered to ischemic stroke patients, safety information of these agents in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.10.003

    authors: Soltani A,Prokop AF,Vaezy S

    更新日期:2008-04-01 00:00:00

  • Microbiological properties of poultry breast meat treated with high-intensity ultrasound.

    abstract::Lactic acid, psychrophilic, and mesophilic bacteria, Escherichia coli, Salmonella spp. and Staphylococcus aureus were enumerated on chicken breasts after treatment with different high intensity ultrasound (frequency 40 kHz, intensity 9.6 W/cm-2) application times (0, 30, and 50 min) and packaging atmospheres (aerobic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.01.001

    authors: Piñon MI,Alarcon-Rojo AD,Renteria AL,Carrillo-Lopez LM

    更新日期:2020-03-01 00:00:00

  • Investigation of rat bone fracture healing using pulsed 1.5 MHz, 30 mW/cm(2) burst ultrasound--axial distance dependency.

    abstract::This study investigated the effect of LIPUS on fracture healing when fractures were exposed to ultrasound at three axial distances: z=0 mm, 60 mm, and 130 mm. We applied LIPUS to rat fracture at these three axial distances mimicking the exposure condition of human fractures at different depths under the soft tissue. M...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.10.013

    authors: Fung CH,Cheung WH,Pounder NM,de Ana FJ,Harrison A,Leung KS

    更新日期:2014-03-01 00:00:00

  • Differentiate low impedance media in closed steel tank using ultrasonic wave tunneling.

    abstract::Ultrasonic wave tunneling through seriously mismatched media, such as steel and water, is possible only when the frequency matches the resonance of the steel plate. But it is nearly impossible to realize continuous wave tunneling if the low acoustic impedance media is air because the transducer frequency cannot be mad...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.07.018

    authors: Wang C,Chen Z,Cao W

    更新日期:2018-01-01 00:00:00

  • Weighted non-linear beamformers for low cost 2-element receive ultrasound imaging system.

    abstract::In this paper, the development of modified beamforming methods, Filtered Delay Weight Multiply and Sum (F-DwMAS) and Filtered Delay Euclidian-Weighted Multiply and Sum (F-DewMAS), are reported. These methods were investigated on a minimum-redundancy synthetic aperture technique, called as 2 element Receive Synthetic A...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106293

    authors: Vayyeti A,Thittai AK

    更新日期:2021-02-01 00:00:00

  • Study on chemical mechanical polishing of silicon wafer with megasonic vibration assisted.

    abstract::Chemical mechanical polishing (CMP) is the primary method to realize the global planarization of silicon wafer. In order to improve this process, a novel method which combined megasonic vibration to assist chemical mechanical polishing (MA-CMP) is developed in this paper. A matching layer structure of polishing head w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.04.005

    authors: Zhai K,He Q,Li L,Ren Y

    更新日期:2017-09-01 00:00:00

  • Numerical investigation of dispersive behaviors for helical thread waveguides using the semi-analytical isogeometric analysis method.

    abstract::In this paper, we propose a semi-analytical isogeometric analysis(S-IGA) approach in the twist space to investigate the dispersive properties in helical thread waveguides, which combines the advantages of the spectral approach and IGA. The convergence and accuracy of the proposed method are discussed, by comparing S-I...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.06.004

    authors: Liu Y,Han Q,Liang Y,Xu G

    更新日期:2018-02-01 00:00:00

  • Diversity of acoustic streaming in a rectangular acoustofluidic field.

    abstract::Diversity of acoustic streaming field in a 2D rectangular chamber with a traveling wave and using water as the acoustic medium is numerically investigated by the finite element method. It is found that the working frequency, the vibration excitation source length, and the distance and phase difference between two sepa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.11.015

    authors: Tang Q,Hu J

    更新日期:2015-04-01 00:00:00

  • Sensitivity of a miniaturized touch probe sensor using PZT thin film vibrator.

    abstract::In this paper, an improved touch probe sensor device for higher sensitivity and low contact force is reported. In order to improve the resolution, we have evaluated the sensitivity and fabricated a miniaturized sensor. The sensor transducer was 3 mm long and had higher resonance frequency. The resonance frequency of t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00091-4

    authors: Kanda T,Kurosawa MK,Higuchi T

    更新日期:2002-05-01 00:00:00

  • Inversion of synthetic and experimental acoustical scattering data for the comparison of two reconstruction methods employing the Born approximation.

    abstract::This work is concerned with the reconstruction, from measured (synthetic or real) data, of a 2D penetrable fluid-like object of arbitrary cross-section embedded in a fluid of infinite extent and insonified by a plane acoustic wave. Green's theorem is used to provide a domain integral representation of the scattered fi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00054-8

    authors: Guillermin R,Lasaygues P,Sessarego JP,Wirgin A

    更新日期:2001-03-01 00:00:00

  • In vivo characterization of the aortic wall stress-strain relationship.

    abstract::Arterial stiffness has been shown to be a good indicator of arterial wall disease. However, a single parameter is insufficient to describe the complex stress-strain relationship of a multi-component, non-linear tissue such as the aorta. We therefore propose a new approach to measure the stress-strain relationship loca...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.01.003

    authors: Danpinid A,Luo J,Vappou J,Terdtoon P,Konofagou EE

    更新日期:2010-06-01 00:00:00

  • Ultrasonic monitoring of film condensation for applications in reduced gravity

    abstract::The film condensation of vapor on a cooled, downward-facing surface is a complex dynamic fluid phenomenon. This paper will describe the theoretical basis, instrumentation approach, and experimental results for a method for ultrasonic monitoring of film condensation. The ultrasound measurement system utilizes a 10 MHz ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00214-0

    authors: Pedersen PC,Cakareski Z,Hermanson JC

    更新日期:2000-03-01 00:00:00

  • Characterization of mechanical and geometrical properties of a tube with axial and circumferential guided waves.

    abstract::Guided waves propagating in cylindrical tubes are frequently applied for the characterization of material or geometrical properties of tubes. In a tube, guided waves can propagate in the axial direction and called axial guided waves, or in the circumferential direction called circumferential guided waves. Dispersion s...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.11.013

    authors: Yeh CH,Yang CH

    更新日期:2011-05-01 00:00:00

  • Surface vibrational modes in disk-shaped resonators.

    abstract::The natural frequencies and distributions of displacement components for the surface vibrational modes in thin isotropic elastic disks are calculated. In particular, the research is focused on even solutions for low-lying resonant vibrations with large angular wave numbers. Several families of modes are found which ar...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.11.002

    authors: Dmitriev AV,Gritsenko DS,Mitrofanov VP

    更新日期:2014-03-01 00:00:00

  • Evidence of a broadband gap in a phononic crystal strip.

    abstract::We experimentally demonstrate a very large ultrasonic band gap in a one-dimensional phononic crystal. The structure consists of periodic tungsten pillars fixed to a tailored silicon strip with a layer of epoxy. Combining local resonances and Bragg scattering, the gap ranges from 450kHz to 1250kHz, which corresponds to...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.003

    authors: Coffy E,Euphrasie S,Addouche M,Vairac P,Khelif A

    更新日期:2017-07-01 00:00:00

  • Long-path measurements of ultrasonic attenuation and velocity for very dilute slurries and liquids and detection of contaminates.

    abstract::The objective was to use multiple paths through the slurry to determine the lowest concentration that provided accurate attenuation measurements and to measure the velocity of sound through an effective long path. Ultrasonic attenuation measurements were obtained for slurries of silica (10 microm diameter) in water fo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.024

    authors: Greenwood MS,Adamson JD,Bamberger JA

    更新日期:2006-12-22 00:00:00

  • Numerical predictions and experiments on the free-plate edge mode.

    abstract::In this paper, te edge mode variation is studied with three different methods: the reciprocal work method, already used by Torvik [J. Acoust. Soc. Am. 41 (1967) 346] to model this phenomenon, the S-parameter method and a finite element model that are applied for the first time to the study of the edge resonance. Moreo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00391-8

    authors: Le Clezio E,Predoi MV,Castaings M,Hosten B,Rousseau M

    更新日期:2003-01-01 00:00:00