2D array design based on Fermat spiral for ultrasound imaging.

Abstract:

:The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in the last years. Nowadays, array technology has made viable the production of 2D arrays with larger flexibility on elements size, shape and position, allowing to study other configurations different to the classical matrix organisation, such as circular, archimedes spiral or polygonal layout between others. In this work, the problem of designing an imaging system array with large apertures and a very limited number of active elements (N(e)=128 and N(e)=256) using the Fermat spiral layout has been studied. As summary, a general discussion about the most interesting cases is presented.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Martínez-Graullera O,Martín CJ,Godoy G,Ullate LG

doi

10.1016/j.ultras.2009.09.010

subject

Has Abstract

pub_date

2010-02-01 00:00:00

pages

280-9

issue

2

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(09)00111-5

journal_volume

50

pub_type

杂志文章
  • Ultrasonic drawing of tungsten wire for incandescent lamps production.

    abstract::An influence of ultrasonic treatment (drawing) on structure, high temperature durability, evaporation and creep behaviours of tungsten single crystal and wires were investigated. A relation of tungsten wires properties with dislocation distribution was determined. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.02.002

    authors: Mordyuk BN,Mordyuk VS,Buryak VV

    更新日期:2004-04-01 00:00:00

  • Development of an ultra-portable echo device connected to USB port.

    abstract::In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.11.009

    authors: Saijo Y,Nitta S,Kobayashi K,Arai H,Nemoto Y

    更新日期:2004-04-01 00:00:00

  • Inline ultrasonic rheometry by pulsed Doppler.

    abstract::This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.027

    authors: Pfund DM,Greenwood MS,Bamberger JA,Pappas RA

    更新日期:2006-12-22 00:00:00

  • New applications for ultrasonic sensors in process industries.

    abstract::Today, sophisticated instruments and algorithms used for process control allow the efficient production of substances with the quality guaranteed to the customer. However, production and management techniques are changing. This article aims to analyze trends resulting from those changes from the point of view of ultra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.047

    authors: Püttmer A

    更新日期:2006-12-22 00:00:00

  • Spectral analysis of Doppler ultrasonic decompression data.

    abstract::Several aspects of spectral analysis of bubble transients in Doppler ultrasonic decompression data are discussed. The computation of energy density spectra, using fast Fourier transform techniques for analyzing bubble transients, is described. Spectral analysis of data from probes implanted within animals, using a con...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(77)90026-9

    authors: Kisman K

    更新日期:1977-05-01 00:00:00

  • Numerical investigation of dispersive behaviors for helical thread waveguides using the semi-analytical isogeometric analysis method.

    abstract::In this paper, we propose a semi-analytical isogeometric analysis(S-IGA) approach in the twist space to investigate the dispersive properties in helical thread waveguides, which combines the advantages of the spectral approach and IGA. The convergence and accuracy of the proposed method are discussed, by comparing S-I...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.06.004

    authors: Liu Y,Han Q,Liang Y,Xu G

    更新日期:2018-02-01 00:00:00

  • Ultrasonic measurements on poroelastic slabs: determination of reflection and transmission coefficients and processing for Biot input parameters.

    abstract::Ultrasonic reflection and transmission measurements on saturated, plane-parallel, poroelastic slabs are presented. A data processing technique is proposed to obtain poroelastic parameters from transmission measurements. A special experimental data acquisition and processing technique is applied to minimize the finite ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.006

    authors: Jocker J,Smeulders D

    更新日期:2009-03-01 00:00:00

  • Stability of alteplase in presence of cavitation.

    abstract::Several experimental studies have demonstrated that ultrasound (US) can accelerate enzymatic fibrinolysis and this effect is further enhanced in the presence of ultrasound contrast agents (UCA). Although UCA have been shown to be safe when administered to ischemic stroke patients, safety information of these agents in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.10.003

    authors: Soltani A,Prokop AF,Vaezy S

    更新日期:2008-04-01 00:00:00

  • Evaluation of crack parameters by a nonlinear frequency-mixing laser ultrasonics method.

    abstract::The local evaluation of several parameters of a crack is realized with a nonlinear laser ultrasonic method. The method is based on the sample excitation by two laser beams, independently intensity modulated at two cyclic frequencies ωH and ωL (ωH≫ωL) and on the detection of nonlinear frequency-mixing ultrasonic compon...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.005

    authors: Mezil S,Chigarev N,Tournat V,Gusev V

    更新日期:2016-07-01 00:00:00

  • Picosecond acoustics method for measuring the thermodynamical properties of solids and liquids at high pressure and high temperature.

    abstract::Based on the original combination of picosecond acoustics and diamond anvils cell, recent improvements to accurately measure hypersonic sound velocities of liquids and solids under extreme conditions are described. To illustrate the capability of this technique, results are given on the pressure and temperature depend...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.04.011

    authors: Decremps F,Gauthier M,Ayrinhac S,Bove L,Belliard L,Perrin B,Morand M,Le Marchand G,Bergame F,Philippe J

    更新日期:2015-02-01 00:00:00

  • Thickness-shear vibration of a quartz plate connected to piezoelectric plates and electric field sensing.

    abstract::We study thickness-shear vibration of a quartz plate connected to two piezoelectric ceramic plates with initial deformations caused by a biasing electric field. The theory for small deformations superposed on finite biasing deformations in an electroelastic body is used. It is shown that the resonant frequencies of th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.07.002

    authors: Zhou Y,Chen W,Yang J,Du J

    更新日期:2011-02-01 00:00:00

  • Baseline subtraction technique in the frequency-wavenumber domain for high sensitivity damage detection.

    abstract::This paper suggests a method for high-sensitivity damage detection. The method is based on pitch-catch measurements of Lamb waves combined with a baseline subtraction technique in the frequency-wavenumber domain. Small amplitude converted modes, generated during the interaction of propagating waves with damage, can th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.08.010

    authors: McKeon P,Yaacoubi S,Declercq NF,Ramadan S,Yaacoubi WK

    更新日期:2014-02-01 00:00:00

  • Arbitrary shaped, liquid filled reverberators with non-resonant transducers for broadband focusing of ultrasound using Time Reversed Acoustics.

    abstract::The ability to generate short focused ultrasonic pulses with duration on the order of one period of carrier frequency depends on the bandwidth of the transmitter as the pulse duration is inversely proportional to the bandwidth. Conventional focusing arrays used for focusing ultrasound have limited bandwidth due to the...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.008

    authors: Sarvazyan A,Fillinger L

    更新日期:2009-03-01 00:00:00

  • Y-shaped jets driven by an ultrasonic beam reflecting on a wall.

    abstract::This paper presents an original experimental and numerical investigation of acoustic streaming driven by an acoustic beam reflecting on a wall. The water experiment features a 2 MHz acoustic beam totally reflecting on one of the tank glass walls. The velocity field in the plane containing the incident and reflected be...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.02.003

    authors: Moudjed B,Botton V,Henry D,Millet S,Ben Hadid H

    更新日期:2016-05-01 00:00:00

  • Microbubble-enhanced hemorrhage control using high intensity focused ultrasound.

    abstract::Our objective was to investigate whether hemorrhage control can be achieved faster when high-intensity focused ultrasound (HIFU) is applied in the presence of ultrasound contrast agents (UCA) as compared to HIFU only application. Incisions (3 cm long and 0.5 cm deep) were produced in the livers of anesthetized rabbits...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.018

    authors: Zderic V,Brayman AA,Sharar SR,Crum LA,Vaezy S

    更新日期:2006-12-01 00:00:00

  • Investigations of the barbell ultrasonic transducer operated in the full-wave vibrational mode.

    abstract::In this paper, the resonance frequency equation and expression of displacement amplitude magnifications of a full-wave barber ultrasonic horn are obtained. By discussing the relationships between the displacement amplitude magnifications and the geometrical dimensions, the optimized design of the horn for the largest ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.12.006

    authors: Fu Z,Xian X,Lin S,Wang C,Hu W,Li G

    更新日期:2012-07-01 00:00:00

  • Fast beating null strip during the reflection of pulsed Gaussian beams incident at the Rayleigh angle.

    abstract::It is well known that harmonic bounded Gaussian beams undergo a transformation into two bounded beams upon reflection on a solid immersed in a liquid. The effect is known as the Schoch effect and can be found at the Rayleigh angle for thick plates and at the different Lamb angles for thin plates. Here, a study is made...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.205

    authors: Declercq NF

    更新日期:2006-12-22 00:00:00

  • Calculations of acoustic scattering from ellipsoidal voids: bends, krill and fish.

    abstract::The T-matrix approach is used to calculate the scattering of sound waves by an ellipsoidal void in a fluid. Results are presented for the total cross-section of a sphere as a function of frequency; this is related to the detection of the onset of bends in divers. Results are also presented for the angular variation in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(83)90073-2

    authors: Cooper G,Temple JA

    更新日期:1983-07-01 00:00:00

  • Investigation of rat bone fracture healing using pulsed 1.5 MHz, 30 mW/cm(2) burst ultrasound--axial distance dependency.

    abstract::This study investigated the effect of LIPUS on fracture healing when fractures were exposed to ultrasound at three axial distances: z=0 mm, 60 mm, and 130 mm. We applied LIPUS to rat fracture at these three axial distances mimicking the exposure condition of human fractures at different depths under the soft tissue. M...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.10.013

    authors: Fung CH,Cheung WH,Pounder NM,de Ana FJ,Harrison A,Leung KS

    更新日期:2014-03-01 00:00:00

  • 1-60 MHz measurements in focused acoustic fields using spatial averaging corrections.

    abstract::The purpose of this research was to develop, implement and verify a measurement technique enabling rapid and dependable characterization of ultrasound hydrophone probes beyond 20 MHz. The technique employs focused acoustic sources to optimize signal-to-noise ratio and spatial averaging correction model to account for ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00166-x

    authors: Radulescu EG,Lewin PA,Nowicki A

    更新日期:2002-05-01 00:00:00

  • Analysis of second harmonic guided waves in pipes using a large-radius asymptotic approximation for axis-symmetric longitudinal modes.

    abstract::Theoretical formulation for the problem of second harmonic guided waves in pipes is presented from the principles of continuum mechanics. The formulation is carried out in the reference configuration of the pipe with an emphasis on the correct use of the "Divergence" operator in the reference configuration. Second har...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.12.007

    authors: Chillara VK,Lissenden CJ

    更新日期:2013-04-01 00:00:00

  • Nondestructive testing using air-borne ultrasound.

    abstract::Over the last two decades, more efficient transducers were developed for the generation and reception of air-borne ultrasound, thus enabling the non-contact, non-contaminating inspection of composite laminates and honeycomb structures widely used in the aerospace industry. This paper presents the fundamentals of makin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.091

    authors: Hsu DK

    更新日期:2006-12-22 00:00:00

  • Automated quantitative analysis of the shift of frequency spectra generated by attenuated signals from contrast microbubbles.

    abstract::The ultrasound-induced harmonic microbubble response spectrum is known to shift to lower frequencies with increasing tissue attenuation. We hypothesized that this shift could be reproducibly detected in received broadband radiofrequency spectra. We used an automatic Gaussian curve-fitting technique to measure the mean...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00397-9

    authors: Bartleson VB,Viggen K,Asanuma T,Kinnick RR,Belohlavek M

    更新日期:2003-03-01 00:00:00

  • Two approaches to multiple specular echo detection using split spectrum processing: moving bandwidth minimization and mathematical morphology.

    abstract::A split spectrum processing technique using a novel moving bandwidth minimization (MBM) method was developed to detect multiple specular targets having different spectral characteristics. Mathematical morphology (MM) algorithms were also implemented in order to compare the results. An experimental approach to optimal ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00024-4

    authors: Grevillot M,Cudel C,Meyer JJ,Jacquey S

    更新日期:1999-09-01 00:00:00

  • Non-contact measurement of the thickness of a surface film using a superimposed ultrasonic standing wave.

    abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106291

    authors: Kanja J,Mills R,Li X,Brunskill H,Hunter AK,Dwyer-Joyce RS

    更新日期:2021-02-01 00:00:00

  • Acoustic resonance scattering from a multilayered cylindrical shell with imperfect bonding.

    abstract::The method of wave function expansion is adopted to study the three dimensional scattering of a time-harmonic plane progressive sound field obliquely incident upon a multi-layered hollow cylinder with interlaminar bonding imperfection. For the generality of solution, each layer is assumed to be cylindrically orthotrop...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.05.007

    authors: Rajabi M,Hasheminejad SM

    更新日期:2009-12-01 00:00:00

  • Needle and seed segmentation in intra-operative 3D ultrasound-guided prostate brachytherapy.

    abstract::In order to guide the needle to the correct location in 3D US-guided brachytherapy, the needle is continuously tracked as it is being inserted. A pre-scan before the needle insertion and a post-scan after the needle insertion are subtracted to obtain a difference image containing the needle. The image is projected alo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.003

    authors: Ding M,Wei Z,Gardi L,Downey DB,Fenster A

    更新日期:2006-12-22 00:00:00

  • Applications of a nanocomposite-inspired in-situ broadband ultrasonic sensor to acousto-ultrasonics-based passive and active structural health monitoring.

    abstract::A novel nanocomposite-inspired in-situ broadband ultrasonic sensor previously developed, with carbon black as the nanofiller and polyvinylidene fluoride as the matrix, was networked for acousto-ultrasonic wave-based passive and active structural health monitoring (SHM). Being lightweight and small, this kind of sensor...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.007

    authors: Liu M,Zeng Z,Xu H,Liao Y,Zhou L,Zhang Z,Su Z

    更新日期:2017-07-01 00:00:00

  • High nonlinearities in Langevin transducer: a comprehensive model.

    abstract::The design and simulation of power transducers are difficult since piezoelectric, dielectric and elastic properties of ferroelectric materials differ from linear behavior when driven at large levels. This paper is devoted to modeling of a resonant power transducer at a high level of dynamic mechanical stress. The powe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.05.017

    authors: Guyomar D,Ducharne B,Sebald G

    更新日期:2011-12-01 00:00:00

  • A fast technique for hyper-echoic region separation from brain ultrasound images using patch based thresholding and cubic B-spline based contour smoothing.

    abstract::Ultrasound image guided brain surgery (UGBS) requires an automatic and fast image segmentation method. The level-set and active contour based algorithms have been found to be useful for obtaining topology-independent boundaries between different image regions. But slow convergence limits their use in online US image s...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106304

    authors: Chel H,Bora PK,Ramchiary KK

    更新日期:2021-03-01 00:00:00