Interlaboratory evaluation of hydrophone sensitivity calibration from 0.1 to 2 MHz via time delay spectrometry.

Abstract:

:Knowing the low-frequency response of hydrophones, down to 100 kHz at least, is important for accurate biomedical ultrasound measurements. However, current international standards do not extend below 500 kHz. Furthermore, commercial hydrophone sources typically do not supply sensitivity data below 1-2 MHz. Therefore, to help identify and validate practical calibration methods below 2 MHz, the authors have extended their previous individual efforts in an interlaboratory evaluation of sensitivity calibration using the swept-frequency technique, time delay spectrometry (TDS). Calibrations were performed for needle and membrane PVDF hydrophones using each laboratory's TDS system. Each site employed the same purpose-built broadband source transducers, comprising both plano-concave and biconcave 1-3 piezocomposite elements 4 cm in diameter, with maximum and minimum thicknesses of approximately 1.5 and 0.1 cm. Agreement between laboratories was within the estimated measurement precision of +/-0.6 dB. The results demonstrated that a TDS system employing such transducers constitutes a viable method for hydrophone calibrations in this frequency range.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Harris GR,Gammell PM,Lewin PA,Radulescu EG

doi

10.1016/j.ultras.2003.12.008

subject

Has Abstract

pub_date

2004-04-01 00:00:00

pages

349-53

issue

1-9

eissn

0041-624X

issn

1874-9968

pii

S0041624X03002300

journal_volume

42

pub_type

杂志文章
  • On-chip ultrasonic manipulation of microparticles by using the flexural vibration of a glass substrate.

    abstract::As biotechnology develops, techniques for manipulating and separating small particles such as cells and DNA are required in the life sciences. This paper investigates on-chip manipulation of microparticles in small channels by using ultrasonic vibration. The chip consists of a rectangular glass substrate with a cross-...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.026

    authors: Yamamoto R,Koyama D,Matsukawa M

    更新日期:2017-08-01 00:00:00

  • Influence of bubble clustering on multibubble sonoluminescence.

    abstract::Influence of clustering of cavitation bubbles on multibubble sonoluminescence (MBSL) in standing wave fields is studied through measurement of MBSL intensity with a photomultiplier tube and observation of corresponding bubble behavior with a high-speed video camera and an intensified charge-coupled device one. It is c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00193-2

    authors: Hatanaka S,Yasui K,Kozuka T,Tuziuti T,Mitome H

    更新日期:2002-05-01 00:00:00

  • Speckle tracking for multi-dimensional flow estimation.

    abstract::Speckle tracking methods overcome the major limitations of current Doppler methods for flow imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages and limitations of two-dimensional algorithms that use a singl...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00182-1

    authors: Bohs LN,Geiman BJ,Anderson ME,Gebhart SC,Trahey GE

    更新日期:2000-03-01 00:00:00

  • Influence of extrinsic operational parameters on salt diffusion during ultrasound assisted meat curing.

    abstract::The present study investigated the effect of geometric parameters of the ultrasound instrument during meat salting in order to enhance salt diffusion and salt distribution in pork meat on a lab scale. The effects of probe size (∅2.5 and 1.3cm) and of different distances between the transducer and the meat sample (0.3,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.017

    authors: Inguglia ES,Zhang Z,Burgess C,Kerry JP,Tiwari BK

    更新日期:2018-02-01 00:00:00

  • Surface and quasi-longitudinal acoustic waves in KTiOAsO₄ single crystals.

    abstract::Surface and quasi-longitudinal acoustic wave properties have been investigated in potassium titanyl arsenate (KTiOAsO₄, KTA) single crystals for the first time. Surface acoustic wave (SAW) velocity, electromechanical coupling coefficient and power flow angle characteristics have been obtained in rotated Y-cut of KTA c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.019

    authors: Taziev RM

    更新日期:2014-02-01 00:00:00

  • Spatial-temporal three-dimensional ultrasound plane-by-plane active cavitation mapping for high-intensity focused ultrasound in free field and pulsatile flow.

    abstract::Cavitation plays important roles in almost all high-intensity focused ultrasound (HIFU) applications. However, current two-dimensional (2D) cavitation mapping could only provide cavitation activity in one plane. This study proposed a three-dimensional (3D) ultrasound plane-by-plane active cavitation mapping (3D-UPACM)...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.010

    authors: Ding T,Hu H,Bai C,Guo S,Yang M,Wang S,Wan M

    更新日期:2016-07-01 00:00:00

  • Arbitrary scattering of an acoustical high-order Bessel trigonometric (non-vortex) beam by a compressible soft fluid sphere.

    abstract::The present analysis extends the previous work on the axial acoustic scattering of a high-order Bessel trigonometric beam (HOBTB) from a fluid sphere [F.G. Mitri, J. Appl. Phys. 109 (2011) 014916] to the generalized case of arbitrary scattering from a fluid sphere placed off-axially. The scattered pressure is expresse...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.12.008

    authors: Mitri FG

    更新日期:2013-07-01 00:00:00

  • The wavelet response as a multiscale characterization of scattering processes at granular interfaces.

    abstract::We perform a multiscale analysis of the backscattering properties of a complex interface between water and a layer of randomly arranged glass beads with diameter D=1 mm. An acoustical experiment is done to record the wavelet response of the interface in a large frequency range from lambda/D=0.3 to lambda/D=15. The wav...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.212

    authors: Le Gonidec Y,Gibert D

    更新日期:2006-11-01 00:00:00

  • 1-3 connectivity lithium niobate composites for high temperature operation.

    abstract::Lithium niobate, LiNbO(3), is a piezoelectric material well known for its high Curie temperature. However, it has often been neglected for use in ultrasonic transducers because of its low electro-mechanical coupling coefficients. Recent advances in signal processing have made this disadvantage less significant and we ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.06.001

    authors: Schmarje N,Kirk KJ,Cochran S

    更新日期:2007-12-01 00:00:00

  • A cylindrical standing wave ultrasonic motor using bending vibration transducer.

    abstract::A cylindrical standing wave ultrasonic motor using bending vibration transducer was proposed in this paper. The proposed stator contains a cylinder and a bending vibration transducer. The two combining sites between the cylinder and the transducer locate at the adjacent wave loops of bending vibration of the transduce...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.12.007

    authors: Liu Y,Chen W,Liu J,Shi S

    更新日期:2011-07-01 00:00:00

  • Characteristic model of travelling wave ultrasonic motor.

    abstract::In general, the design and analysis of ultrasonic motor and motor's control strategy are based on mathematical model. The academic model is widely used in the analysis of traveling wave ultrasonic motor (TWUSM). But the dispersive characteristic of piezoelectric ceramics and other complicated process, such as the fric...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.012

    authors: Jingzhuo S,Dongmei Y

    更新日期:2014-02-01 00:00:00

  • Some studies on evaluation of degradation in composite adhesive joints using ultrasonic techniques.

    abstract::Experimental and theoretical studies on degradation of composite-epoxy adhesive joints were carried out on samples having different interfacial and cohesive properties. Oblique incidence ultrasonic inspection of bonded joints revealed that degradation in the adhesive can be measured by significant variation in reflect...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.01.014

    authors: Vijaya Kumar RL,Bhat MR,Murthy CR

    更新日期:2013-08-01 00:00:00

  • Absence of biological damage from prolonged exposure to intravascular ultrasound: a swine model.

    abstract::Ultrasound (US) has been used in IMS II (intravascular US) and CLOTBUST (transcranial US) clinical trials for thrombolysis. During the treatment, in addition to the targeted thrombus, other biological components, such as blood and vessel walls are subjected to long durations of US exposure. In this study we explored e...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.10.004

    authors: Soltani A,Singhal R,Garcia JL,Raju NR

    更新日期:2007-03-01 00:00:00

  • Depth-of-field enhancement in Filtered-Delay Multiply and Sum beamformed images using Synthetic Aperture Focusing.

    abstract::The Synthetic Aperture Focusing (SAF) technique makes it possible to achieve a higher and more uniform quality of ultrasound images throughout depth, as if both transmit and receive dynamic focusing were applied. In this work we combine a particular implementation of SAF, called Synthetic Transmit Aperture (STA) techn...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.022

    authors: Matrone G,Savoia AS,Caliano G,Magenes G

    更新日期:2017-03-01 00:00:00

  • A fast technique for hyper-echoic region separation from brain ultrasound images using patch based thresholding and cubic B-spline based contour smoothing.

    abstract::Ultrasound image guided brain surgery (UGBS) requires an automatic and fast image segmentation method. The level-set and active contour based algorithms have been found to be useful for obtaining topology-independent boundaries between different image regions. But slow convergence limits their use in online US image s...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106304

    authors: Chel H,Bora PK,Ramchiary KK

    更新日期:2021-03-01 00:00:00

  • Backward waves and energy fluxes excited in acoustic medium with an immersed plate.

    abstract::Explicit integral representations for the wave fields generated by air-coupled or underwater transducers in an acoustic medium with a submerged elastic (metallic or laminate composite) plate are obtained in the form of path Fourier integrals. Together with the far-field asymptotics for the incident, reflected, transmi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.10.001

    authors: Glushkov EV,Glushkova NV,Miakisheva OA

    更新日期:2019-04-01 00:00:00

  • Dependence of sonochemical luminescence on various sound fields

    abstract::To understand the effect of the sound field on sonochemical luminescence, the exact sound pressure must be determined in each field. In this study it was determined by the Shlieren method, which measures the sound pressure without mixing the sound fields. We compared the efficiency of the sonochemical luminescence in ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00203-6

    authors: Yanagida H,Masubuchi Y,Minagawa K,Takimoto J,Ogata T,Koyama K

    更新日期:2000-03-01 00:00:00

  • Spectral analysis of Doppler ultrasonic decompression data.

    abstract::Several aspects of spectral analysis of bubble transients in Doppler ultrasonic decompression data are discussed. The computation of energy density spectra, using fast Fourier transform techniques for analyzing bubble transients, is described. Spectral analysis of data from probes implanted within animals, using a con...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(77)90026-9

    authors: Kisman K

    更新日期:1977-05-01 00:00:00

  • Impact of localized inhomogeneity on the surface-wave velocity and bulk-wave reflection in solids.

    abstract::The effect of a weak surface, near-surface and interfacial inhomogeneity on the frequency dependence of the surface wave velocity and of the SH (shear horizontal) wave reflectivity in isotropic elastic media is studied analytically and numerically. The inhomogeneity is modeled as an infinite planar layer with continuo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.001

    authors: Baron C,Shuvalov AL,Poncelet O

    更新日期:2007-03-01 00:00:00

  • Ultrasonic flaw detection using threshold modified S-transform.

    abstract::Interference noising originating from the ultrasonic testing defect signal seriously influences the accuracy of the signal extraction and defect location. Time-frequency analysis methods are mainly used to improve the defects detection resolution. In fact, the S-transform, a hybrid of the Short time Fourier transform ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.004

    authors: Benammar A,Drai R,Guessoum A

    更新日期:2014-02-01 00:00:00

  • Viability of plant cell suspensions exposed to homogeneous ultrasonic fields of different energy density and wave type.

    abstract::Exposure of Petunia hybrida cell suspensions to ultrasound at a frequency of 2.43 MHz in a standing wave field at an energy density of 70 Jm-3 (pressure amplitude of 0.78 MPa) decreased their mean viability to 35% after 20 min of sonication. A comparison of propagating wave and standing wave treatments at equal freque...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00166-3

    authors: Böhm H,Anthony P,Davey MR,Briarty LG,Power JB,Lowe KC,Benes E,Gröschl M

    更新日期:2000-03-01 00:00:00

  • Remote characterization of defects in plates with viscoelastic coatings using guided waves.

    abstract::The remote inspection for defects in large metallic elements such as pipes, tubes and plates is a field where guided waves are being applied with success. There are a number of situations where a surface coating is added for corrosion protection or insulation purposes. Since the coating materials are usually viscoelas...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.072

    authors: Galán JM,Abascal R

    更新日期:2004-04-01 00:00:00

  • Perspectives in clinical uses of high-intensity focused ultrasound.

    abstract::Focused ultrasound holds promise in a large number of therapeutic applications. It has long been known that high intensity focused ultrasound can kill tissue through coagulative necrosis. However, it is only in recent years that practical clinical applications are becoming possible, with the development of high power ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.04.003

    authors: Clement GT

    更新日期:2004-08-01 00:00:00

  • Focused ultrasound phantom model for blood brain barrier disruption.

    abstract::In this paper a high intensity focused ultrasound (FUS) phantom model was developed, in order to be used in experiments for Blood Brain Barrier (BBB) disruption. The target was to create a phantom model that represents the disruption of the BBB during ultrasound application. An appropriate experimental setup was creat...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106244

    authors: Alekou T,Giannakou M,Damianou C

    更新日期:2021-02-01 00:00:00

  • Ultrasonic excitation affects friction interactions between food materials and cutting tools.

    abstract::In the food industry, ultrasonic cutting is used to improve separation by a reduction of the cutting force. This reduction can be attributed to the modification of tool-workpiece interactions at the cutting edge and along the tool flanks because of the superposition of the cutting movement with ultrasonic vibration of...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.03.001

    authors: Schneider Y,Zahn S,Schindler C,Rohm H

    更新日期:2009-06-01 00:00:00

  • Influence of nesting shell size on brightness longevity and resistance to ultrasound-induced dissolution during enhanced B-mode contrast imaging.

    abstract::This study aims to bridge the gap between transport mechanisms of an improved ultrasound contrast agent (UCA) and its resulting behavior in a clinical imaging study. Phospholipid-shelled microbubbles nested within the aqueous core of a polymer microcapsule are examined for their use and feasibility as an improved UCA....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.06.019

    authors: Wallace N,Dicker S,Lewin P,Wrenn SP

    更新日期:2014-12-01 00:00:00

  • High-intensity ultrasound irradiation promotes the release of extracellular vesicles from C2C12 myotubes.

    abstract::Skeletal muscle is an important secretory organ in mammals, producing myriad chemical mediators ("myokines") with distinct biological action in different tissues, including anti-inflammatory activity. Extracellular vesicles (EVs) have recently been identified as a mode of myokine transport from muscle, facilitating su...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106243

    authors: Maeshige N,Langston PK,Yuan ZM,Kondo H,Fujino H

    更新日期:2021-02-01 00:00:00

  • Natural beam focusing of non-axisymmetric guided waves in large-diameter pipes.

    abstract::The propagation of non-axisymmetric guided waves in larger diameter pipes is studied in this paper by treating the guided waves as corresponding Lamb waves in an unwrapped plate. This approximation leads to a simpler method for calculating the phase velocities of hollow cylinder guided waves, which reveals a beam focu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2005.07.002

    authors: Li J,Rose JL

    更新日期:2006-01-01 00:00:00

  • Fundamental wave amplitude difference imaging for detection and characterization of embedded cracks.

    abstract::An ultrasonic technique for imaging nonlinear scatterers, such as partially-closed cracks, buried in a medium has been recently proposed. The method called fundamental wave amplitude difference (FAD) consists of a sequence of acquisitions with different subsets of elements for each line of the image. An image revealin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.02.003

    authors: Haupert S,Ohara Y,Carcreff E,Renaud G

    更新日期:2019-07-01 00:00:00

  • Ultrasonic strain imaging and reconstructive elastography for biological tissue.

    abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.007

    authors: Khaled W,Reichling S,Bruhns OT,Ermert H

    更新日期:2006-12-22 00:00:00