Spatial-temporal three-dimensional ultrasound plane-by-plane active cavitation mapping for high-intensity focused ultrasound in free field and pulsatile flow.

Abstract:

:Cavitation plays important roles in almost all high-intensity focused ultrasound (HIFU) applications. However, current two-dimensional (2D) cavitation mapping could only provide cavitation activity in one plane. This study proposed a three-dimensional (3D) ultrasound plane-by-plane active cavitation mapping (3D-UPACM) for HIFU in free field and pulsatile flow. The acquisition of channel-domain raw radio-frequency (RF) data in 3D space was performed by sequential plane-by-plane 2D ultrafast active cavitation mapping. Between two adjacent unit locations, there was a waiting time to make cavitation nuclei distribution of the liquid back to the original state. The 3D cavitation map equivalent to the one detected at one time and over the entire volume could be reconstructed by Marching Cube algorithm. Minimum variance (MV) adaptive beamforming was combined with coherence factor (CF) weighting (MVCF) or compressive sensing (CS) method (MVCS) to process the raw RF data for improved beamforming or more rapid data processing. The feasibility of 3D-UPACM was demonstrated in tap-water and a phantom vessel with pulsatile flow. The time interval between temporal evolutions of cavitation bubble cloud could be several microseconds. MVCF beamformer had a signal-to-noise ratio (SNR) at 14.17dB higher, lateral and axial resolution at 2.88times and 1.88times, respectively, which were compared with those of B-mode active cavitation mapping. MVCS beamformer had only 14.94% time penalty of that of MVCF beamformer. This 3D-UPACM technique employs the linear array of a current ultrasound diagnosis system rather than a 2D array transducer to decrease the cost of the instrument. Moreover, although the application is limited by the requirement for a gassy fluid medium or a constant supply of new cavitation nuclei that allows replenishment of nuclei between HIFU exposures, this technique may exhibit a useful tool in 3D cavitation mapping for HIFU with high speed, precision and resolution, especially in a laboratory environment where more careful analysis may be required under controlled conditions.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Ding T,Hu H,Bai C,Guo S,Yang M,Wang S,Wan M

doi

10.1016/j.ultras.2016.04.010

subject

Has Abstract

pub_date

2016-07-01 00:00:00

pages

166-81

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(16)30021-X

journal_volume

69

pub_type

杂志文章
  • Development of a portable 3D ultrasound imaging system for musculoskeletal tissues.

    abstract::3D ultrasound is a promising imaging modality for clinical diagnosis and treatment monitoring. Its cost is relatively low in comparison with CT and MRI, no intensive training and radiation protection is required for its operation, and its hardware is movable and can potentially be portable. In this study, we developed...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.05.003

    authors: Huang QH,Zheng YP,Lu MH,Chi ZR

    更新日期:2005-01-01 00:00:00

  • Micromachined ultrasound transducers with improved coupling factors from a CMOS compatible process

    abstract::For medical high frequency acoustic imaging purposes the reduction in size of a single transducer element for one-dimensional and even more for two-dimensional arrays is more and more limited by fabrication and cabling technology. In the fields of industrial distance measurement and simple object recognition low cost ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00085-2

    authors: Eccardt PC,Niederer K

    更新日期:2000-03-01 00:00:00

  • Miniaturization of surface acoustic waves rotary motor.

    abstract::This paper presents the experimental study of a miniaturized surface acoustic waves (SAWs) rotary motor and the theoretical calculation. After the first success in SAW rotary motor operating at 9.85 MHz, a smaller rotary motor is designed. With the operating frequency of 30 MHz and the driving voltage of 120 V(p-p), t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00264-0

    authors: Cheng LP,Zhang GM,Zhang SY,Yu J,Shui XJ

    更新日期:2002-06-01 00:00:00

  • Effect of lay-up of sub-waveguide on transmission of S(o) mode from main waveguide to sub-waveguides.

    abstract::This paper focuses on transmission characteristics of fundamental symmetric Lamb mode (So) at the junction of a main waveguide and sub-waveguides in composite laminates. Numerical simulations on transmission of So from the main to sub-waveguide revealed that transmission factors of the modes depend on stacking sequenc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.08.003

    authors: Ramadas C

    更新日期:2016-01-01 00:00:00

  • Architectures for ultrasonic planetary sample retrieval tools.

    abstract::Traditional rotary corers and sample retrieval mechanisms for planetary drilling suffer from a variety of technical difficulties. A heavy and rigid drillstring must be assembled on-site and deployed with considerable applied preload and torque, and these mechanical loadings are difficult to react in a low gravity envi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.06.001

    authors: Harkness P,Lucas M,Cardoni A

    更新日期:2011-12-01 00:00:00

  • Interlaboratory evaluation of hydrophone sensitivity calibration from 0.1 to 2 MHz via time delay spectrometry.

    abstract::Knowing the low-frequency response of hydrophones, down to 100 kHz at least, is important for accurate biomedical ultrasound measurements. However, current international standards do not extend below 500 kHz. Furthermore, commercial hydrophone sources typically do not supply sensitivity data below 1-2 MHz. Therefore, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.008

    authors: Harris GR,Gammell PM,Lewin PA,Radulescu EG

    更新日期:2004-04-01 00:00:00

  • Automated quantitative analysis of the shift of frequency spectra generated by attenuated signals from contrast microbubbles.

    abstract::The ultrasound-induced harmonic microbubble response spectrum is known to shift to lower frequencies with increasing tissue attenuation. We hypothesized that this shift could be reproducibly detected in received broadband radiofrequency spectra. We used an automatic Gaussian curve-fitting technique to measure the mean...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00397-9

    authors: Bartleson VB,Viggen K,Asanuma T,Kinnick RR,Belohlavek M

    更新日期:2003-03-01 00:00:00

  • Experimental and numerical study of evanescent waves in the mini stopband of a 1D phononic crystal.

    abstract::This paper deals with the analysis of the guided evanescent waves in stopbands of a 1D phononic crystal (PC). A new numerical implementation is shown in order to get the complex values of the wavenumbers in a frequency range where a gap occurs. The considered phononic system is an aluminum plate with a one-dimensional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.09.009

    authors: Bavencoffe M,Morvan B,Hladky-Hennion AC,Izbicki JL

    更新日期:2013-02-01 00:00:00

  • Natural beam focusing of non-axisymmetric guided waves in large-diameter pipes.

    abstract::The propagation of non-axisymmetric guided waves in larger diameter pipes is studied in this paper by treating the guided waves as corresponding Lamb waves in an unwrapped plate. This approximation leads to a simpler method for calculating the phase velocities of hollow cylinder guided waves, which reveals a beam focu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2005.07.002

    authors: Li J,Rose JL

    更新日期:2006-01-01 00:00:00

  • Ultrasonic measurements on poroelastic slabs: determination of reflection and transmission coefficients and processing for Biot input parameters.

    abstract::Ultrasonic reflection and transmission measurements on saturated, plane-parallel, poroelastic slabs are presented. A data processing technique is proposed to obtain poroelastic parameters from transmission measurements. A special experimental data acquisition and processing technique is applied to minimize the finite ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.006

    authors: Jocker J,Smeulders D

    更新日期:2009-03-01 00:00:00

  • Elastic constants of solids and fluids with initial pressure via a unified approach based on equations-of-state.

    abstract::The second and third-order Brugger elastic constants are obtained for liquids and ideal gases having an initial hydrostatic pressure p1. For liquids the second-order elastic constants are C₁₁=A+p₁, C₁₂=A-p₁, and the third-order constants are C₁₁₁=-(B+5A+3p₁), C₁₁₂=-(B+A-p₁), and C₁₂₃=A-B-p₁, where A and B are the Beye...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.01.012

    authors: Cantrell JH

    更新日期:2014-07-01 00:00:00

  • Location of acoustic emission sources generated by air flow

    abstract::The location of continuous acoustic emission sources is a difficult problem of non-destructive testing. This article describes one-dimensional location of continuous acoustic emission sources by using an intelligent locator. The intelligent locator solves a location problem based on learning from examples. To verify w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00079-7

    authors: Kosel T,Grabec I I,Muzic P

    更新日期:2000-03-01 00:00:00

  • Effect of texture and grain shape on ultrasonic backscattering in polycrystals.

    abstract::An ultrasonic backscattering model is developed for textured polycrystalline materials with orthotropic or trigonal grains of ellipsoidal shape. The model allows us to simulate realistic microstructures and orthotropic macroscopic material textures resulting from thermomechanical processing for a broad variety of mate...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.02.020

    authors: Li J,Yang L,Rokhlin SI

    更新日期:2014-09-01 00:00:00

  • How many times should we repeat measuring liver stiffness using shear wave elastography?: 5-repetition versus 10-repetition protocols.

    abstract::The purpose of this study is to evaluate whether a 5-repetition liver stiffness (LS) measurement as the standard protocol of shear wave elastography (SWE) is comparable to a conventional 10-repetition measurement protocol and to identify factors that influence the reliability of the 5-repetition protocol. A total of 3...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.08.005

    authors: Choi SH,Jeong WK,Kim Y,Lim S,Kwon JW,Kim TY,Kim MY,Sohn JH

    更新日期:2016-12-01 00:00:00

  • Multibubble sonoluminescence enhancement by fluid flow.

    abstract::Forced fluid flow can cause the enhancement of multibubble sonoluminescence (SL) under suitable conditions. The effect of directional flow with a circulator is similar to that of rotating flow with a stirrer. The mechanism of the enhancement is that both flows prevent cavitation bubbles from coalescing and clustering,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.022

    authors: Hatanaka S,Mitome H,Yasui K,Hayashi S

    更新日期:2006-12-22 00:00:00

  • DC effects, sub-harmonics, stochasticity and "memory" for contact acoustic non-linearity.

    abstract::Acoustic wave interaction with non-bonded contacts was found to be inherently non-linear due to asymmetrical stiffness distribution across the interface. A diode-type non-linearity results in local static elastic fields inside the contact, which are shown to be a source of transient longitudinal and shear DC-acoustic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00241-x

    authors: Korshak BA,Solodov IY,Ballad EM

    更新日期:2002-05-01 00:00:00

  • A novel approach to quantitative ultrasonic naked gene delivery and its non-invasive assessment.

    abstract::The purpose of this study was to investigate practical, safe, easy-to-use, non-cytotoxic, and reliable parameters to apply to an ultrasound (US) naked gene therapy system. The ultrasound pressure at the point of cell exposure was measured using a calibrated hydrophone and the intensity calculated. An acoustic power me...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.06.007

    authors: Wei W,Zhengzhong B,Yongjie W,Lafeng Y,Yalin M

    更新日期:2004-12-01 00:00:00

  • Current topics on sonoelectrochemistry.

    abstract::Sonoelectrochemistry is undergoing a reemerging activity in the last years with an increasing number of papers appearing in a wide range of peer review journals. Applied studies which cover environmental treatments, synthesis or characterization of nanostructures, polymeric materials synthesis, analytical procedures, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.022

    authors: González-García J,Esclapez MD,Bonete P,Hernández YV,Garretón LG,Sáez V

    更新日期:2010-02-01 00:00:00

  • Inline ultrasonic rheometry by pulsed Doppler.

    abstract::This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.027

    authors: Pfund DM,Greenwood MS,Bamberger JA,Pappas RA

    更新日期:2006-12-22 00:00:00

  • SH ultrasonic guided waves for the evaluation of interfacial adhesion.

    abstract::Shear-Horizontally (SH) polarized, ultrasonic, guided wave modes are considered in order to infer changes in the adhesive properties at several interfaces located within an adhesive bond joining two metallic plates. Specific aluminium lap-joint samples were produced, with different adhesive properties at up to four in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.002

    authors: Castaings M

    更新日期:2014-09-01 00:00:00

  • Acoustic scattering from complex elastic shells: visualization of S0, A0 and A waves

    abstract::Acoustic scattering phenomena from complex immersed elastic shells are studied by high-speed Schlieren visualization for spark-generated spherical quasi-Dirac excitations. The situations considered are air-filled cylindrical shells under normal insonification and air-filled cylindrical shells soldered at one end with ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00165-1

    authors: Derbesse L,Pernod P,Latard V V,Merlen A,Decultot D,Touraine N,Maze G

    更新日期:2000-03-01 00:00:00

  • Control of the ultrasonic beam transmitted through an irregular profile using a smart flexible transducer: modelling and application.

    abstract::In most of industries as aeronautics, aerospace and nuclear, the main part of the ultrasonic testing is carried out directly in touch with the inspected component. Among others, the cooling piping of French pressurized water reactor comprises many welding components with complex geometry: elbows, butt welds, nozzles. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00145-2

    authors: Roy O,Mahaut S,Casula O

    更新日期:2002-05-01 00:00:00

  • Location of multiple proximate flaws using perpendicular NDT ultrasonic arrays.

    abstract::An improved method for ultrasonic location of multiple flaws using perpendicular ultrasonic arrays, working in near-field conditions, is presented. The method uses the pulse-echo technique and is based on the processing of the information acquired by both the elemental emitting transducers and their adjacent ones. Thi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.107

    authors: Rodríguez MA,Ramos A,San Emeterio JL

    更新日期:2006-12-22 00:00:00

  • Bonding and impedance matching of acoustic transducers using silver epoxy.

    abstract::Silver epoxy was selected to bond transducer plates on glass substrates. The properties and thickness of the bonding medium affect the electrical input impedance of the transducer. Thus, the thickness of the silver epoxy bonding layer was used as a design parameter to optimize the structure for the transducer input im...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.11.010

    authors: Son KT,Lee CC

    更新日期:2012-04-01 00:00:00

  • Rare earth ultrasonic transducer technique research.

    abstract::Transducer is the necessary and most important part in the maxonics. New applications demand for new transducer, and the renovation of the transducer will open a new field for the application of the maxonics. The important method to develop new transducer is to find and develop new material. The rare earth giant magne...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.128

    authors: Liu W,Zhou L,Xia T,Yu H

    更新日期:2006-12-22 00:00:00

  • Surface acoustic waves at the vacuum-thermoviscoelastic solid interface.

    abstract::The present investigation concerns the propagation of surface waves at the vacuum-solid interface of a solid which is isotropic and thermoviscoelastic, i.e., for which the effects of heat conductivity need to be taken into account. Calculations show that, in addition to the Rayleigh wave, a thermal surface wave propag...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00017-2

    authors: Deschamps M,Poncelet O,Dilhaire S,Claeys W

    更新日期:2000-07-01 00:00:00

  • Guided waves in anisotropic and quasi-isotropic aerospace composites: three-dimensional simulation and experiment.

    abstract::Three-dimensional (3D) elastic wave simulations can be used to investigate and optimize nondestructive evaluation (NDE) and structural health monitoring (SHM) ultrasonic damage detection techniques for aerospace materials. 3D anisotropic elastodynamic finite integration technique (EFIT) has been implemented for ultras...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.05.007

    authors: Leckey CA,Rogge MD,Raymond Parker F

    更新日期:2014-01-01 00:00:00

  • Nondestructive testing using air-borne ultrasound.

    abstract::Over the last two decades, more efficient transducers were developed for the generation and reception of air-borne ultrasound, thus enabling the non-contact, non-contaminating inspection of composite laminates and honeycomb structures widely used in the aerospace industry. This paper presents the fundamentals of makin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.091

    authors: Hsu DK

    更新日期:2006-12-22 00:00:00

  • Characterization of air-coupled ultrasound transducers in the frequency range 40 kHz-2 mHz using light diffraction tomography.

    abstract::The aim of this work was to show the applicability of light diffraction tomography on airborne ultrasound in the frequency range 40 kHz-2 MHz. Seven different air-coupled transducers were measured to show the method's performance regarding linearity, absolute pressure measurements, phase measurements, frequency respon...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00168-7

    authors: Almqvist M,Holm A,Persson HW,Lindström K

    更新日期:2000-01-01 00:00:00

  • Investigating the absolute phase information in acoustic wave resonance scattering.

    abstract::The aim of this work is to investigate the absolute phase information in resonance acoustic scattering by spheres and cylinders and place this work in the broader context of scattering in which the properties of the magnitude and (processed) phase have been examined in a more general way than in the classical resonanc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.01.002

    authors: Mitri FG,Greenleaf JF,Fellah ZE,Fatemi M

    更新日期:2008-07-01 00:00:00