Abstract:
:The purpose of this study was to investigate practical, safe, easy-to-use, non-cytotoxic, and reliable parameters to apply to an ultrasound (US) naked gene therapy system. The ultrasound pressure at the point of cell exposure was measured using a calibrated hydrophone and the intensity calculated. An acoustic power meter calibrated using a hydrophone was used to measure the power of the transducer. Four cell types were exposed to US with different exposure times and intensities. Fluorescent microscopy, spectrophotometry, scanning electron microscope, laser scanning confocal microscopy, flow cytometry and histogram analysis were used to evaluate the results of the study. The plasmid of green fluorescent protein (GFP) served as the reporter gene. The energy accumulation E in US gene delivery for 90% cell survival was defined as the optimal parameters (E=3.56+/-0.06), and at 80% cell survival was defined as the damage threshold (E=59.67+/-3.54). US safely delivered GFP into S180 cells (35.1 kHz) at these optimal parameters without obvious damage or cytotoxity in vitro. Exposed cell function was proved normal in vivo. The transfection rate was 35.83+/-2.53% (n=6) in viable cells, corresponding to 90.17+/-1.47% (n=6) cell viability. The intensity of GFP expression showed a higher fluorescent peak in the group of adeno-associated virus GFP vector (AVV-GFP) than in the control group (P<0.001). The effect of US gene delivery and cell viability correlated as a fifth order polynomial with US intensity and exposure time. With optimal parameters, US can safely deliver naked a gene into a cell without damage to cell function. Both optimal uptake and expression of gene depend on the energy E at 90% cell survival. E can be applied as a control factor for bioeffects when combined with other parameters. Stable caviation results in optimal parameters for gene delivery and the transient caviation may cause cell damage, which will bring about a sharp rise of permeabilization. The results may be applied to the development of a novel clinical gene therapeutic system.
journal_name
Ultrasonicsjournal_title
Ultrasonicsauthors
Wei W,Zhengzhong B,Yongjie W,Lafeng Y,Yalin Mdoi
10.1016/j.ultras.2004.06.007subject
Has Abstractpub_date
2004-12-01 00:00:00pages
69-77issue
2eissn
0041-624Xissn
1874-9968pii
S0041-624X(04)00240-9journal_volume
43pub_type
杂志文章相关文献
ULTRASONICS文献大全abstract::In a recent report [F.G. Mitri, Z.E.A. Fellah, Ultrasonics 51 (2011) 719-724], it has been found that the instantaneous axial force (i.e. acting along the axis of wave propagation) of a Bessel acoustic beam centered on a sphere is only determined for the fundamental order (i.e. m=0) but vanishes when the beam is of vo...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.07.009
更新日期:2012-01-01 00:00:00
abstract::In most applications of MEMS the mechanical properties of the used materials are key parameters for the perfect working of the microsystems. Measuring bulk acoustic waves excited in MEMS structures with ultra-short laser pulses is a powerful method for the accurate and non-destructive evaluation as well as for the cha...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.049
更新日期:2004-04-01 00:00:00
abstract::Ultrasonic vibration cutting is an efficient cutting process for mechanical micro-machining. This process can generate intricate surface textures with different geometric characteristics. Micro-grooves/micro-channels are among the most frequently encountered micro-structures and, as such, are the focus of this paper. ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.12.016
更新日期:2016-04-01 00:00:00
abstract::Many sparse signal representation (SSR) algorithms have been developed in the past decade. The advantages of SSR such as compact representations and super resolution lead to the state of the art performance of SSR for processing ultrasonic non-destructive evaluation (NDE) signals. Choosing a suitable SSR algorithm and...
journal_title:Ultrasonics
pub_type: 杂志文章,评审
doi:10.1016/j.ultras.2011.10.001
更新日期:2012-03-01 00:00:00
abstract::In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.080
更新日期:2004-04-01 00:00:00
abstract::Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. P...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.02.012
更新日期:2017-05-01 00:00:00
abstract::Ultrasonic non-destructive testing of polycrystalline structures can be disturbed by scattering at grain boundaries. Understanding and modeling this so-called "structural noise" is crucial for characterization as well as detection purposes. Structural noise can be considered as a fingerprint of the material under inve...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.06.012
更新日期:2014-01-01 00:00:00
abstract::Investigation was carried out to study the effects of maximum aggregate size (MAS) (12.5mm, 19.0mm, 25.0mm, 37.5mm, and 50.0mm) on ultrasonic pulse velocity (UPV) of concrete. For investigation, first class bricks were collected and broken to make coarse aggregate. The aggregates were tested for specific gravity, abso...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.04.006
更新日期:2016-07-01 00:00:00
abstract::Current medical ultrasonic scanning instrumentation permits the display of fine image detail (speckle) which does not transfer useful information but degrades the apparent low contrast resolution in the image. An adaptive two-dimensional filter has been developed which uses local features of image texture to recognize...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(86)90072-7
更新日期:1986-01-01 00:00:00
abstract::In spite of many advances in analytical and numerical modeling techniques for solving different engineering problems, an efficient solution technique for wave propagation modeling of an electromagnetic acoustic transducer (EMAT) system is still missing. Distributed point source method (DPSM) is a newly developed semi-...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2009.12.003
更新日期:2010-05-01 00:00:00
abstract::This paper reports the development of a two-dimensional thick film lead zirconate titanate (PZT) ultrasonic transducer array, operating at frequency approximately 7.5MHz, to demonstrate the potential of this fabrication technique for microparticle manipulation. All layers of the array are screen-printed then sintered ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.05.010
更新日期:2015-09-01 00:00:00
abstract::In general, the design and analysis of ultrasonic motor and motor's control strategy are based on mathematical model. The academic model is widely used in the analysis of traveling wave ultrasonic motor (TWUSM). But the dispersive characteristic of piezoelectric ceramics and other complicated process, such as the fric...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.09.012
更新日期:2014-02-01 00:00:00
abstract::It is shown that a diffuse field is not devoid of phase information, but has a correlation function equal to the Green's function. More specifically, the cross-correlation between diffuse signals in two transducers is very nearly equal to the direct response of one transducer to an impulse applied to the other. This i...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00156-7
更新日期:2002-05-01 00:00:00
abstract::This paper deals with the influence of gas law on ultrasonic behaviour of porous media when the saturating fluid is high pressured. Previous works have demonstrated that ultrasonic transmission through a porous sample with variations of the static pressure (up to 18 bars) of the saturating fluid allows the characteriz...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.02.003
更新日期:2010-06-01 00:00:00
abstract::Cones and wedges inserted between an ultrasonic transducer and the specimen provide the transducer (circular or rectangular shape) with enhanced capability for point or line contact with the specimen. Such an arrangement is useful in that the transducer can be used for transmitting to and receiving from a point (or li...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.10.002
更新日期:2005-03-01 00:00:00
abstract::An ultrasonic backscattering model is developed for textured polycrystalline materials with orthotropic or trigonal grains of ellipsoidal shape. The model allows us to simulate realistic microstructures and orthotropic macroscopic material textures resulting from thermomechanical processing for a broad variety of mate...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.02.020
更新日期:2014-09-01 00:00:00
abstract::In this newly developed method, the ultrasonic diagnosis has become quantitative. The data will remain quantitative so far as an image storage tube is used. With the conventional storage type CRT, it is impossible to memorize the reflected echo signals of different strength levels. But with our method, it becomes poss...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(75)90036-0
更新日期:1975-09-01 00:00:00
abstract::A surface ultrasonic wave approach was presented for measuring surface stress of brush electro-plating nickel coating specimen, and the influence of coating thickness on surface stress measurement was discussed. In this research, two Rayleigh wave transducers with 5MHz frequency were employed to collect Rayleigh wave ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.02.003
更新日期:2012-09-01 00:00:00
abstract::In this work, the existence of the optimal working frequency for ultrasonic motors (USMs) is theoretically and experimentally verified for the first time, at which working point the power dissipation of the motors arrives at its minimum value. The mathematical model of the mechanical quality factor is initially deduce...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.04.015
更新日期:2016-08-01 00:00:00
abstract::The motivation for this research stems from a need for providing a non-destructive testing method capable of detecting and locating any defects and microstructural variations within armour ceramic components before issuing them to the soldiers who rely on them for their survival. The development of an automated ultras...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.05.027
更新日期:2015-09-01 00:00:00
abstract::In acoustic and ultrasonic non-destructive testing techniques, it is sometimes beneficial to concentrate sound energy at a chosen location in space and at a specific instance in time, for example to improve the signal-to-noise ratio or activate the nonlinearity of damage features. Time Reversal (TR) techniques, taking...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.01.010
更新日期:2016-04-01 00:00:00
abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.06.007
更新日期:2006-12-22 00:00:00
abstract::The second and third-order Brugger elastic constants are obtained for liquids and ideal gases having an initial hydrostatic pressure p1. For liquids the second-order elastic constants are C₁₁=A+p₁, C₁₂=A-p₁, and the third-order constants are C₁₁₁=-(B+5A+3p₁), C₁₁₂=-(B+A-p₁), and C₁₂₃=A-B-p₁, where A and B are the Beye...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.01.012
更新日期:2014-07-01 00:00:00
abstract::Interference noising originating from the ultrasonic testing defect signal seriously influences the accuracy of the signal extraction and defect location. Time-frequency analysis methods are mainly used to improve the defects detection resolution. In fact, the S-transform, a hybrid of the Short time Fourier transform ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.09.004
更新日期:2014-02-01 00:00:00
abstract::Lactic acid, psychrophilic, and mesophilic bacteria, Escherichia coli, Salmonella spp. and Staphylococcus aureus were enumerated on chicken breasts after treatment with different high intensity ultrasound (frequency 40 kHz, intensity 9.6 W/cm-2) application times (0, 30, and 50 min) and packaging atmospheres (aerobic ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2018.01.001
更新日期:2020-03-01 00:00:00
abstract::An inversion algorithm (termed AEDep) is proposed for estimating the depth of acoustic emission (AE) sources in plate-like structural components. The work is motivated by the need for characterizing early-stage fatigue crack growth in such components. The algorithm achieves depth estimation by automatically extracting...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.105975
更新日期:2019-11-01 00:00:00
abstract::B-Scan images have been used as a means of detecting the onset of cavitation in tissues. New echoes appearing during simultaneous sonication with therapeutic ultrasound have often been attributed to bubble formation. In this study temperature rises up to 15 degrees C W-1 cm2 in guinea pig leg (post-mortem) were found,...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(91)90028-7
更新日期:1991-07-01 00:00:00
abstract::Human umbilical cords were exposed to high amplitude focussed ultrasonic pulses with focal energy densities 0.6 and 0.4 mJ mm-2. The endothelium of the exposed vessel (vein) was examined by means of confocal laser scanning microscopy and scanning electron microscopy. The degree of tissue change ranged from the inducti...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(94)90111-2
更新日期:1994-09-01 00:00:00
abstract::Broken wires often occur at multiple locations in the same wire of a strand due to the recovery length, which is defined as the length of the wire taking up its full share of the axial load from the break point. The detection of broken-wire flaws at multiple locations along the same wire is investigated using guided w...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.05.003
更新日期:2013-01-01 00:00:00
abstract::Aluminium sheet thickness has been calculated from ultrasonic data obtained using a send-receive, radially polarised electromagnetic acoustic transducer (EMAT). Sheets in the thickness range between 0.1 and 0.5 mm have been measured using this non-contact approach at a stand-off of up to 1.5 mm. Normal incidence shear...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(01)00083-x
更新日期:2001-10-01 00:00:00