Abstract:
:This paper reports the development of a two-dimensional thick film lead zirconate titanate (PZT) ultrasonic transducer array, operating at frequency approximately 7.5MHz, to demonstrate the potential of this fabrication technique for microparticle manipulation. All layers of the array are screen-printed then sintered on an alumina substrate without any subsequent patterning processes. The thickness of the thick film PZT is 139±2μm, the element pitch of the array is 2.3mm, and the dimension of each individual PZT element is 2×2mm(2) with top electrode 1.7×1.7mm(2). The measured relative dielectric constant of the PZT is 2250±100 and the dielectric loss is 0.09±0.005 at 10kHz. Finite element analysis was used to predict the behaviour of the array and to optimise its configuration. Electrical impedance spectroscopy and laser vibrometry were used to characterise the array experimentally. The measured surface motion of a single element is on the order of tens of nanometres with a 10Vpeak continuous sinusoidal excitation. Particle manipulation experiments have been demonstrated with the array by manipulating Ø10μm polystyrene microspheres in degassed water. The simplified array fabrication process and the bulk production capability of screen-printing suggest potential for the commercialisation of multilayer planar resonant devices for ultrasonic particle manipulation.
journal_name
Ultrasonicsjournal_title
Ultrasonicsauthors
Qiu Y,Wang H,Gebhardt S,Bolhovitins A,Démoré CE,Schönecker A,Cochran Sdoi
10.1016/j.ultras.2015.05.010subject
Has Abstractpub_date
2015-09-01 00:00:00pages
136-46eissn
0041-624Xissn
1874-9968pii
S0041-624X(15)00129-8journal_volume
62pub_type
杂志文章相关文献
ULTRASONICS文献大全abstract::Theoretical formulation for the problem of second harmonic guided waves in pipes is presented from the principles of continuum mechanics. The formulation is carried out in the reference configuration of the pipe with an emphasis on the correct use of the "Divergence" operator in the reference configuration. Second har...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.12.007
更新日期:2013-04-01 00:00:00
abstract::Ultrasound image guided brain surgery (UGBS) requires an automatic and fast image segmentation method. The level-set and active contour based algorithms have been found to be useful for obtaining topology-independent boundaries between different image regions. But slow convergence limits their use in online US image s...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106304
更新日期:2021-03-01 00:00:00
abstract::Targeted mechanical cell stimulation has been extensively studied for a better understanding of its effect on cellular mechanotransduction signaling pathways and structures by utilizing a variety of mechanical sources. In this work, an ultrasound-driven single cell stimulation method is thus proposed, and a preliminar...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.03.002
更新日期:2012-09-01 00:00:00
abstract::The properties of optical to acoustic transduction of semiconductor superlattices have been explored for several years in the sub terahertz frequency range. Using femtosecond laser pulses focused on these structures, acoustic modes are excited with a frequency related to the periodicity of the structure stacking. We h...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.07.009
更新日期:2015-02-01 00:00:00
abstract::As biotechnology develops, techniques for manipulating and separating small particles such as cells and DNA are required in the life sciences. This paper investigates on-chip manipulation of microparticles in small channels by using ultrasonic vibration. The chip consists of a rectangular glass substrate with a cross-...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.11.026
更新日期:2017-08-01 00:00:00
abstract::The purpose of this study was to investigate practical, safe, easy-to-use, non-cytotoxic, and reliable parameters to apply to an ultrasound (US) naked gene therapy system. The ultrasound pressure at the point of cell exposure was measured using a calibrated hydrophone and the intensity calculated. An acoustic power me...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.06.007
更新日期:2004-12-01 00:00:00
abstract::The present study is focused on the development and characterization of an innovative substrate to optimize the axial resolution of ultrasonic transducers on a silicon substrate that is dedicated to ultrasound imaging. The substrate must efficiently dampen wave propagation to avoid degradation of the axial resolution ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.01.006
更新日期:2019-07-01 00:00:00
abstract::This paper deals with the influence of gas law on ultrasonic behaviour of porous media when the saturating fluid is high pressured. Previous works have demonstrated that ultrasonic transmission through a porous sample with variations of the static pressure (up to 18 bars) of the saturating fluid allows the characteriz...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.02.003
更新日期:2010-06-01 00:00:00
abstract::The propagation of non-axisymmetric guided waves in larger diameter pipes is studied in this paper by treating the guided waves as corresponding Lamb waves in an unwrapped plate. This approximation leads to a simpler method for calculating the phase velocities of hollow cylinder guided waves, which reveals a beam focu...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2005.07.002
更新日期:2006-01-01 00:00:00
abstract::This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acousti...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.04.001
更新日期:2010-08-01 00:00:00
abstract::A nonlinear acoustic method to assess the damage level of a complex medium is discussed herein. Thanks to the highly nonlinear elastic signatures of cracks or, more generally, internal solid contacts, this method is able to distinguish between contributions from linear wave scattering by a heterogeneity and contributi...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.09.015
更新日期:2017-01-01 00:00:00
abstract::The attenuation of ultrasound in homogenates of bovine skeletal muscle and suspensions of myofibrils was measured over the frequency range 1.5-7 MHz, and found to be proportional to protein concentration in both. In the homogenates it varied with frequency and temperature in a similar way to the attenuation in post ri...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(88)90071-6
更新日期:1988-07-01 00:00:00
abstract::Silver epoxy was selected to bond transducer plates on glass substrates. The properties and thickness of the bonding medium affect the electrical input impedance of the transducer. Thus, the thickness of the silver epoxy bonding layer was used as a design parameter to optimize the structure for the transducer input im...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.11.010
更新日期:2012-04-01 00:00:00
abstract::In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.080
更新日期:2004-04-01 00:00:00
abstract::Speckle tracking methods overcome the major limitations of current Doppler methods for flow imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages and limitations of two-dimensional algorithms that use a singl...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(99)00182-1
更新日期:2000-03-01 00:00:00
abstract::The aim of this work is to investigate the absolute phase information in resonance acoustic scattering by spheres and cylinders and place this work in the broader context of scattering in which the properties of the magnitude and (processed) phase have been examined in a more general way than in the classical resonanc...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.01.002
更新日期:2008-07-01 00:00:00
abstract::In a recent report [F.G. Mitri, Z.E.A. Fellah, Ultrasonics 51 (2011) 719-724], it has been found that the instantaneous axial force (i.e. acting along the axis of wave propagation) of a Bessel acoustic beam centered on a sphere is only determined for the fundamental order (i.e. m=0) but vanishes when the beam is of vo...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.07.009
更新日期:2012-01-01 00:00:00
abstract::This paper presents the results of the theoretical and 2D FEM modeling excitation and detection of evanescent acoustic waves in piezoelectric plates. By application of 2D ordinary differential equations derived by Auld, we obtained the dispersion curves of A1 and SH1 waves in YX LiNbO3 and YX KNbO3 plates in proximity...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.105961
更新日期:2019-11-01 00:00:00
abstract::Effective receive beamforming in medical ultrasound imaging is important for enhancing spatial and contrast resolution. In current ultrasound receive beamforming, a constant sound speed (e.g., 1540m/s) is assumed. However, the variations of sound speed in soft tissues could introduce phase distortions, leading to degr...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.03.007
更新日期:2011-10-01 00:00:00
abstract::In medical ultrasound imaging, dynamic range (DR) is defined as the difference between the maximum and minimum values of the displayed signal to display and it is one of the most essential parameters that determine its image quality. Typically, DR is given with a fixed value and adjusted manually by operators, which l...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.09.012
更新日期:2015-02-01 00:00:00
abstract::A noble method for continuous leakage source location with one sensor in gas-filled pipe and noisy environment is proposed based on wavelet analysis and modal location theory. The leakage signals were analyzed into high and low frequencies by wavelet decomposition and noises and reflected waves were omitted. Then the ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.06.004
更新日期:2015-09-01 00:00:00
abstract::The T-matrix approach is used to calculate the scattering of sound waves by an ellipsoidal void in a fluid. Results are presented for the total cross-section of a sphere as a function of frequency; this is related to the detection of the onset of bends in divers. Results are also presented for the angular variation in...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(83)90073-2
更新日期:1983-07-01 00:00:00
abstract::Both pinnae of anaesthetized male guinea-pigs were contused in a reproducible manner and one immediately treated with 0.75 MHz ultrasound at an average therapeutic intensity of 0.61 W cm-2 for a period of 2 min. The lividity and rate of resorption of the rusultant bruises were measured by a photometric method. The res...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(78)90021-5
更新日期:1978-09-01 00:00:00
abstract::Electromagnetic-acoustic transducers (EMATs) consist of a magnet and a coil. They are advantageous in some non-destructive evaluation (NDE) applications because no direct contact with the specimen is needed to send and receive ultrasonic waves. However, EMATs commonly require excitation peak powers greater than 1kW an...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.02.009
更新日期:2017-07-01 00:00:00
abstract::In this study, 3D finite element simulation of ultrasonically-assisted drilling is carried out to analyze the effect of ultrasonic vibrations on common difficulties existed in conventional drilling. Influence of harmonic movement of drill bit on the formation of built-up edge is experimentally evaluated and also discu...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.11.009
更新日期:2017-03-01 00:00:00
abstract::The present study investigated the effect of geometric parameters of the ultrasound instrument during meat salting in order to enhance salt diffusion and salt distribution in pork meat on a lab scale. The effects of probe size (∅2.5 and 1.3cm) and of different distances between the transducer and the meat sample (0.3,...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.03.017
更新日期:2018-02-01 00:00:00
abstract::An improved method for ultrasonic location of multiple flaws using perpendicular ultrasonic arrays, working in near-field conditions, is presented. The method uses the pulse-echo technique and is based on the processing of the information acquired by both the elemental emitting transducers and their adjacent ones. Thi...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.107
更新日期:2006-12-22 00:00:00
abstract::In this paper, an optimization method aimed at designing aperiodic linear sparse arrays is proposed that is based on the stochastic optimization methodology called simulated annealing. Such a method optimizes the positions and the weight coefficients of each element of a linear array in order to obtain a beam pattern ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(99)00089-x
更新日期:2000-03-01 00:00:00
abstract::The Mössbauer and X-rays analysis of as-received Fe-powder and Fe-powder mechanically alloyed with C using high power ultrasonics were carried out. The powder blend of Fe-powder and graphite was processed in He environment during 5 to 50 h. The dissolution of carbon in iron particles and inhomogeneous distribution of ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.002
更新日期:2004-04-01 00:00:00
abstract::Ultrasonic techniques have been used to measure the elastic properties of bone. Eight human tibiae were used to determine and map the elastic properties of cortical and cancellous bone. The present study shows cortical bone to be at least orthotropic in its material symmetry. The mechanical properties of cortical bone...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(96)00078-9
更新日期:1996-12-01 00:00:00