Speckle tracking for multi-dimensional flow estimation.

Abstract:

:Speckle tracking methods overcome the major limitations of current Doppler methods for flow imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages and limitations of two-dimensional algorithms that use a single transducer aperture. Ensemble tracking, a recent speckle tracking method based upon parallel receive processing, is described. Experimental results with ensemble tracking indicate the ability to measure laminar flow in a phantom at a beam-vessel angle of 60 degrees, which had not been possible with previous 2D speckle tracking methods. Finally, important areas for future research in speckle tracking are briefly summarized.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Bohs LN,Geiman BJ,Anderson ME,Gebhart SC,Trahey GE

doi

10.1016/s0041-624x(99)00182-1

subject

Has Abstract

pub_date

2000-03-01 00:00:00

pages

369-75

issue

1-8

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(99)00182-1

journal_volume

38

pub_type

杂志文章
  • Experiment and numerical simulation for laser ultrasonic measurement of residual stress.

    abstract::Laser ultrasonic is a most promising method for non-destructive evaluation of residual stress. The residual stress of thin steel plate is measured by laser ultrasonic technique. The pre-stress loading device is designed which can easily realize the condition of the specimen being laser ultrasonic tested at the same ti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.08.013

    authors: Zhan Y,Liu C,Kong X,Lin Z

    更新日期:2017-01-01 00:00:00

  • Sensitivity improvement of a pump-probe set-up for thin film and microstructure metrology.

    abstract::This investigation deals with various new aspects of the sensitivity improvement of a pump-probe laser based acoustic method. A short laser pulse is used to excite a mechanical pulse thermo-elastically. Echoes of these mechanical pulses reaching the surface are causing a slight change of the optical reflectivity. The ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00207-x

    authors: Vollmann J,Profunser DM,Dual J

    更新日期:2002-05-01 00:00:00

  • 100 MHz bandwidth planar laser-generated ultrasound source for hydrophone calibration.

    abstract::High-frequency calibration of hydrophones is becoming increasingly important, both for clinical and scientific applications of ultrasound, and user safety. At present, the calibrations available routinely to the user community extend to 60 MHz. However, hydrophones that can measure beyond this are available, and ultra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106218

    authors: Rajagopal S,Cox BT

    更新日期:2020-12-01 00:00:00

  • A sparse digital signal model for ultrasonic nondestructive evaluation of layered materials.

    abstract::Signal modeling has been proven to be an useful tool to characterize damaged materials under ultrasonic nondestructive evaluation (NDE). In this paper, we introduce a novel digital signal model for ultrasonic NDE of multilayered materials. This model borrows concepts from lattice filter theory, and bridges them to the...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.05.013

    authors: Bochud N,Gomez AM,Rus G,Peinado AM

    更新日期:2015-09-01 00:00:00

  • Fast beating null strip during the reflection of pulsed Gaussian beams incident at the Rayleigh angle.

    abstract::It is well known that harmonic bounded Gaussian beams undergo a transformation into two bounded beams upon reflection on a solid immersed in a liquid. The effect is known as the Schoch effect and can be found at the Rayleigh angle for thick plates and at the different Lamb angles for thin plates. Here, a study is made...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.205

    authors: Declercq NF

    更新日期:2006-12-22 00:00:00

  • Attenuation of ultrasound in homogenates of bovine skeletal muscle and other tissues.

    abstract::The attenuation of ultrasound in homogenates of bovine skeletal muscle and suspensions of myofibrils was measured over the frequency range 1.5-7 MHz, and found to be proportional to protein concentration in both. In the homogenates it varied with frequency and temperature in a similar way to the attenuation in post ri...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(88)90071-6

    authors: Shore D,Miles CA

    更新日期:1988-07-01 00:00:00

  • Screen-printed ultrasonic 2-D matrix array transducers for microparticle manipulation.

    abstract::This paper reports the development of a two-dimensional thick film lead zirconate titanate (PZT) ultrasonic transducer array, operating at frequency approximately 7.5MHz, to demonstrate the potential of this fabrication technique for microparticle manipulation. All layers of the array are screen-printed then sintered ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.05.010

    authors: Qiu Y,Wang H,Gebhardt S,Bolhovitins A,Démoré CE,Schönecker A,Cochran S

    更新日期:2015-09-01 00:00:00

  • Wide bandwidth fiber-optic ultrasound probe in MOMS technology: Preliminary signal processing results.

    abstract::An ultrasonic probe consisting of two optical fiber-based miniaturized transducers for wideband ultrasound emission and detection is employed for the characterization of in vitro biological tissues. In the probe, ultrasound generation is obtained by thermoelastic emission from patterned carbon films in Micro-Opto-Mech...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.024

    authors: Vannacci E,Granchi S,Belsito L,Roncaglia A,Biagi E

    更新日期:2017-03-01 00:00:00

  • DC effects, sub-harmonics, stochasticity and "memory" for contact acoustic non-linearity.

    abstract::Acoustic wave interaction with non-bonded contacts was found to be inherently non-linear due to asymmetrical stiffness distribution across the interface. A diode-type non-linearity results in local static elastic fields inside the contact, which are shown to be a source of transient longitudinal and shear DC-acoustic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00241-x

    authors: Korshak BA,Solodov IY,Ballad EM

    更新日期:2002-05-01 00:00:00

  • Real-time on-line ultrasonic monitoring for bubbles in ceramic 'slip' in pottery pipelines.

    abstract::When casting ceramic items in potteries, liquid 'slip' is passed from a settling tank, through overhead pipelines, before being pumped manually into the moulds. It is not uncommon for bubbles to be introduced into the slip as it passes through the complex piping network, and indeed the presence of bubbles is a major s...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.07.008

    authors: Yim GT,Leighton TG

    更新日期:2010-01-01 00:00:00

  • Micro-scale finite element modeling of ultrasound propagation in aluminum trabecular bone-mimicking phantoms: A comparison between numerical simulation and experimental results.

    abstract::The present study investigated the accuracy of micro-scale finite element modeling for simulating broadband ultrasound propagation in water-saturated trabecular bone-mimicking phantoms. To this end, five commercially manufactured aluminum foam samples as trabecular bone-mimicking phantoms were utilized for ultrasonic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.01.014

    authors: Vafaeian B,Le LH,Tran TN,El-Rich M,El-Bialy T,Adeeb S

    更新日期:2016-05-01 00:00:00

  • 1-60 MHz measurements in focused acoustic fields using spatial averaging corrections.

    abstract::The purpose of this research was to develop, implement and verify a measurement technique enabling rapid and dependable characterization of ultrasound hydrophone probes beyond 20 MHz. The technique employs focused acoustic sources to optimize signal-to-noise ratio and spatial averaging correction model to account for ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00166-x

    authors: Radulescu EG,Lewin PA,Nowicki A

    更新日期:2002-05-01 00:00:00

  • Effect of texture and grain shape on ultrasonic backscattering in polycrystals.

    abstract::An ultrasonic backscattering model is developed for textured polycrystalline materials with orthotropic or trigonal grains of ellipsoidal shape. The model allows us to simulate realistic microstructures and orthotropic macroscopic material textures resulting from thermomechanical processing for a broad variety of mate...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.02.020

    authors: Li J,Yang L,Rokhlin SI

    更新日期:2014-09-01 00:00:00

  • Ultrasonic excitation affects friction interactions between food materials and cutting tools.

    abstract::In the food industry, ultrasonic cutting is used to improve separation by a reduction of the cutting force. This reduction can be attributed to the modification of tool-workpiece interactions at the cutting edge and along the tool flanks because of the superposition of the cutting movement with ultrasonic vibration of...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.03.001

    authors: Schneider Y,Zahn S,Schindler C,Rohm H

    更新日期:2009-06-01 00:00:00

  • Sonothrombolysis with magnetic microbubbles under a rotational magnetic field.

    abstract::Thrombosis is an extremely critical clinical condition where a clot forms inside a blood vessel which blocks the blood flow through the cardiovascular system. Previous sonothrombolysis methods using ultrasound and microbubbles (MBs) often have a relatively low lysis rate due to the low microbubbles concentration at cl...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.06.004

    authors: Zhang B,Kim H,Wu H,Gao Y,Jiang X

    更新日期:2019-09-01 00:00:00

  • Experimental and numerical study of ultrasonically-assisted drilling.

    abstract::In this study, 3D finite element simulation of ultrasonically-assisted drilling is carried out to analyze the effect of ultrasonic vibrations on common difficulties existed in conventional drilling. Influence of harmonic movement of drill bit on the formation of built-up edge is experimentally evaluated and also discu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.009

    authors: Lotfi M,Amini S

    更新日期:2017-03-01 00:00:00

  • Ultrasonic strain imaging and reconstructive elastography for biological tissue.

    abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.007

    authors: Khaled W,Reichling S,Bruhns OT,Ermert H

    更新日期:2006-12-22 00:00:00

  • A critical assessment of the in-vitro measurement of cortical bone stiffness with ultrasound.

    abstract::Elasticity assessment based on bulk wave velocity (BWV) measurements is the most popular technique to characterize the anisotropic stiffness tensor in cortical bone. Typically, a cuboid bone specimen is cut with its sides along the different anatomical directions. Then, the velocity of shear and longitudinal waves pro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.05.009

    authors: Peralta L,Cai X,Laugier P,Grimal Q

    更新日期:2017-09-01 00:00:00

  • Some studies on evaluation of degradation in composite adhesive joints using ultrasonic techniques.

    abstract::Experimental and theoretical studies on degradation of composite-epoxy adhesive joints were carried out on samples having different interfacial and cohesive properties. Oblique incidence ultrasonic inspection of bonded joints revealed that degradation in the adhesive can be measured by significant variation in reflect...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.01.014

    authors: Vijaya Kumar RL,Bhat MR,Murthy CR

    更新日期:2013-08-01 00:00:00

  • Generation of sub-microsecond quasi-unipolar pressure pulses.

    abstract::We present a method to generate sub-microsecond quasi-unipolar pressure pulses. Our approach is based on the laser irradiation of a thin copper wire submerged in water. The acoustic waveforms were recorded using two different, well characterized, wideband detection techniques: piezoelectric and optical interferometry....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.05.002

    authors: González MG,Riobó LM,Ciocci Brazzano L,Veiras FE,Sorichetti PA,Santiago GD

    更新日期:2019-09-01 00:00:00

  • Nondestructive testing using air-borne ultrasound.

    abstract::Over the last two decades, more efficient transducers were developed for the generation and reception of air-borne ultrasound, thus enabling the non-contact, non-contaminating inspection of composite laminates and honeycomb structures widely used in the aerospace industry. This paper presents the fundamentals of makin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.091

    authors: Hsu DK

    更新日期:2006-12-22 00:00:00

  • Location of acoustic emission sources generated by air flow

    abstract::The location of continuous acoustic emission sources is a difficult problem of non-destructive testing. This article describes one-dimensional location of continuous acoustic emission sources by using an intelligent locator. The intelligent locator solves a location problem based on learning from examples. To verify w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00079-7

    authors: Kosel T,Grabec I I,Muzic P

    更新日期:2000-03-01 00:00:00

  • An improved Richardson-Lucy iterative algorithm for C-scan image restoration and inclusion size measurement.

    abstract::The accuracy of measuring inclusion size in direct C-scan image of immersion ultrasonic testing is restricted by the lateral resolution of the focused transducer, even if a high frequency is used, and the blurred edge due to scattering of sound waves at inclusions. In this work, an improved image restoration method th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.07.021

    authors: Chen D,Xiao H,Xu J

    更新日期:2019-01-01 00:00:00

  • Excitation and detection of evanescent acoustic waves in piezoelectric plates: Theoretical and 2D FEM modeling.

    abstract::This paper presents the results of the theoretical and 2D FEM modeling excitation and detection of evanescent acoustic waves in piezoelectric plates. By application of 2D ordinary differential equations derived by Auld, we obtained the dispersion curves of A1 and SH1 waves in YX LiNbO3 and YX KNbO3 plates in proximity...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105961

    authors: Kuznetsova I,Nedospasov I,Smirnov A,Qian ZH,Wang B,Dai XY

    更新日期:2019-11-01 00:00:00

  • On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent.

    abstract::The goal standard of contrast echocardiography is the absolute measure of myocardial perfusion using a contrast agent. Actually, several contrast agents are developed. All these agents show left ventricular opacification after intravenous injection. However, none of these agents shows an acceptable enhancement of the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(97)00137-6

    authors: Bouakaz A,de Jong N,Cachard C,Jouini K

    更新日期:1998-02-01 00:00:00

  • Ultrasonic drawing of tungsten wire for incandescent lamps production.

    abstract::An influence of ultrasonic treatment (drawing) on structure, high temperature durability, evaporation and creep behaviours of tungsten single crystal and wires were investigated. A relation of tungsten wires properties with dislocation distribution was determined. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.02.002

    authors: Mordyuk BN,Mordyuk VS,Buryak VV

    更新日期:2004-04-01 00:00:00

  • Verification of surface wave solutions obtained by the reciprocity theorem.

    abstract::Surface wave motions generated by a time-harmonic point load applied at the surface of an isotropic linearly elastic half-space are conventionally solved by the use of integral transform techniques. The inverse transforms, are often complicated and will not always yield closed-form solutions. In this paper expressions...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.05.003

    authors: Phan H,Cho Y,Achenbach JD

    更新日期:2014-09-01 00:00:00

  • Torsional ultrasonic transducer computational design optimization.

    abstract::A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predomina...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.05.001

    authors: Melchor J,Rus G

    更新日期:2014-09-01 00:00:00

  • Evidence of dissipative and growing nonlinearity in Lamb waves due to stress-relaxation and material degradation in composites.

    abstract::Experimentally observed dissipated nonlinearity in Lamb wave propagation in composites due to stress-relaxation is reported herein. It was found that the stress relaxation in composite is inherently coupled with the second order nonlinear parameter derived from the Lamb wave modes. Due to the combined effect of intern...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.01.002

    authors: Patra S,Ahmed H,Saadatzi M,Banerjee S

    更新日期:2019-07-01 00:00:00

  • Propagation of thickness shear waves in a periodically corrugated quartz crystal plate and its application exploration in acoustic wave filters.

    abstract::The propagation of thickness shear waves in a periodically corrugated quartz crystal plate is investigated in the present paper using a power series expansion technique. In the proposed simulation model, an equivalent continuity of shear stress moment is introduced as an approximation to handle sectional interfaces wi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.004

    authors: Li P,Cheng L

    更新日期:2017-05-01 00:00:00