Influence of extrinsic operational parameters on salt diffusion during ultrasound assisted meat curing.

Abstract:

:The present study investigated the effect of geometric parameters of the ultrasound instrument during meat salting in order to enhance salt diffusion and salt distribution in pork meat on a lab scale. The effects of probe size (∅2.5 and 1.3cm) and of different distances between the transducer and the meat sample (0.3, 0.5, and 0.8cm) on NaCl diffusion were investigated. Changes in the moisture content and NaCl gain were used to evaluate salt distribution and diffusion in the samples, parallel and perpendicular to ultrasound propagation direction. Results showed that 0.3cm was the most efficient distance between the probe and the sample to ensure a higher salt diffusion rate. A distance of 0.5cm was however considered as a trade-off distance to ensure salt diffusion and maintenance of meat quality parameters. The enhancement of salt diffusion by ultrasound was observed to decrease with increased horizontal distance from the probe. This study is of valuable importance for meat processing industries willing to apply new technologies on a larger scale and with defined operational standards. The data suggest that the geometric parameters of ultrasound systems can have strong influence on the efficiency of ultrasonic enhancement of NaCl uptake in meat and can be a crucial element in determining salt uptake during meat processing.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Inguglia ES,Zhang Z,Burgess C,Kerry JP,Tiwari BK

doi

10.1016/j.ultras.2017.03.017

subject

Has Abstract

pub_date

2018-02-01 00:00:00

pages

164-170

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(16)30375-4

journal_volume

83

pub_type

杂志文章
  • Estimation methods for flow imaging with high frequency ultrasound.

    abstract::This article proposes to estimate slow blood flow with high frequency ultrasound imaging. The proposed technique combines 2 methods. First, a statistical method, called Speckle Flow Imaging (SFI) based on the analysis of changes in the speckle pattern along time, gives an index directly related to the total velocity v...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.025

    authors: Aoudi W,Liebgott H,Needles A,Yang V,Foster FS,Vray D

    更新日期:2006-12-22 00:00:00

  • Speckle tracking for multi-dimensional flow estimation.

    abstract::Speckle tracking methods overcome the major limitations of current Doppler methods for flow imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages and limitations of two-dimensional algorithms that use a singl...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00182-1

    authors: Bohs LN,Geiman BJ,Anderson ME,Gebhart SC,Trahey GE

    更新日期:2000-03-01 00:00:00

  • Ultrasonic spectroscopy of pure cyclic compounds.

    abstract::Ultrasonic studies of the group of halogens of benzene and particularly dependence of acoustic parameters on the structure of organic liquids, demonstrate some interesting regularities in the group of these compounds in gas and liquid states. In this paper results for five cyclic liquids: bromo-, chloro-, fluoro- and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.146

    authors: Linde BB,Lezhnev NB

    更新日期:2006-12-22 00:00:00

  • Suppression of human 8-oxoguanine DNA glycosylase (OGG1) augments ultrasound-induced apoptosis in cervical cancer cells.

    abstract:PURPOSE:Human 8-oxoguanine DNA glycosylase (OGG1) is a major base excision repair enzyme, and it was reported to suppress the activation of intrinsic apoptotic signaling pathway in response to oxidative stress. In this study, our aim was to investigate the effects of OGG1 downregulation on ultrasound-induced apoptosis ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.07.005

    authors: Xu T,Nie Y,Bai J,Li L,Yang B,Zheng G,Zhang J,Yu J,Cheng X,Jiao J,Jing H

    更新日期:2016-12-01 00:00:00

  • Characterization of mechanical and geometrical properties of a tube with axial and circumferential guided waves.

    abstract::Guided waves propagating in cylindrical tubes are frequently applied for the characterization of material or geometrical properties of tubes. In a tube, guided waves can propagate in the axial direction and called axial guided waves, or in the circumferential direction called circumferential guided waves. Dispersion s...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.11.013

    authors: Yeh CH,Yang CH

    更新日期:2011-05-01 00:00:00

  • Ultrasonic characterization of Cu-Al-Ni single crystals lattice stability in the vicinity of the phase transition.

    abstract::Measurements of elastic constants of the austenite phase when approaching the phase transformation either upon cooling or stressing is of the crucial interest for the shape memory alloy field. Acoustic properties (wave velocity and also attenuation changes) of the Cu-Al-Ni single crystal were investigated in situ duri...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.029

    authors: Landa M,Novák V,Sedlák P,Sittner P

    更新日期:2004-04-01 00:00:00

  • Ultrasonic monitoring of film condensation for applications in reduced gravity

    abstract::The film condensation of vapor on a cooled, downward-facing surface is a complex dynamic fluid phenomenon. This paper will describe the theoretical basis, instrumentation approach, and experimental results for a method for ultrasonic monitoring of film condensation. The ultrasound measurement system utilizes a 10 MHz ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00214-0

    authors: Pedersen PC,Cakareski Z,Hermanson JC

    更新日期:2000-03-01 00:00:00

  • The performance and design of ultrasonic vibration system for flexural mode.

    abstract::The matrix method for analyzing flexural vibration system is outlined. The displacement, stress and velocity gain of ultrasonic flexural vibration systems are investigated by transfer matrix method. A design method is given for flexural transducer and vibration system. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00034-2

    authors: Zhou G

    更新日期:2000-11-01 00:00:00

  • Limited damage of tissue mimic caused by a collapsing bubble under low-frequency ultrasound exposure.

    abstract::In this study, we investigated the bubble induced serious damage to tissue mimic exposed to 27-kHz ultrasound. The initial bubble radius ranged from 80 to 100 μm, which corresponded approximately to the experimentally-evaluated resonant radius of the given ultrasound frequency. The tissue mimic consisted of 10 wt% gel...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.011

    authors: Yoshida K,Obata K,Tsukamoto A,Ushida T,Watanabe Y

    更新日期:2014-08-01 00:00:00

  • Development of an optical fiber hydrophone with fiber Bragg grating

    abstract::A new type of optical fiber hydrophone is constructed with a fiber Bragg grating (FBG) based on the intensity modulation of laser light in an FBG under the influence of sound pressure. The FBG hydrophone shows linearity, with dynamic range about 70 dB. It can measure amplitude and phase of an acoustic field in real ti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00105-5

    authors: Takahashi N,Yoshimura K,Takahashi S,Imamura K

    更新日期:2000-03-01 00:00:00

  • Investigation of ultrasonic absorption in the MHz frequency range by silicon substrates with a built-in porous silicon layer.

    abstract::The present study is focused on the development and characterization of an innovative substrate to optimize the axial resolution of ultrasonic transducers on a silicon substrate that is dedicated to ultrasound imaging. The substrate must efficiently dampen wave propagation to avoid degradation of the axial resolution ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.01.006

    authors: Lascaud J,Defforge T,Gautier G,Certon D

    更新日期:2019-07-01 00:00:00

  • Depth-of-field enhancement in Filtered-Delay Multiply and Sum beamformed images using Synthetic Aperture Focusing.

    abstract::The Synthetic Aperture Focusing (SAF) technique makes it possible to achieve a higher and more uniform quality of ultrasound images throughout depth, as if both transmit and receive dynamic focusing were applied. In this work we combine a particular implementation of SAF, called Synthetic Transmit Aperture (STA) techn...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.022

    authors: Matrone G,Savoia AS,Caliano G,Magenes G

    更新日期:2017-03-01 00:00:00

  • Architectures for ultrasonic planetary sample retrieval tools.

    abstract::Traditional rotary corers and sample retrieval mechanisms for planetary drilling suffer from a variety of technical difficulties. A heavy and rigid drillstring must be assembled on-site and deployed with considerable applied preload and torque, and these mechanical loadings are difficult to react in a low gravity envi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.06.001

    authors: Harkness P,Lucas M,Cardoni A

    更新日期:2011-12-01 00:00:00

  • A new topological structure for the Langevin-type ultrasonic transducer.

    abstract::In this paper, a new topological structure for the Langevin-type ultrasonic transducer is proposed and investigated. The two cylindrical terminal blocks are conically shaped with four supporting plates each, and two cooling fins are disposed at the bottom of terminal blocks, adjacent to the piezoelectric rings. Experi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.008

    authors: Lu X,Hu J,Peng H,Wang Y

    更新日期:2017-03-01 00:00:00

  • Axial acoustic radiation force of progressive cylindrical diverging waves on a rigid and a soft cylinder immersed in an ideal compressible fluid.

    abstract:BACKGROUND AND MOTIVATION:Previous works investigating the radiation force of diverging spherical progressive waves incident upon spherical particles have demonstrated the direction of reversal of the force when the particle is subjected to a curved wave-front. In this communication, the analysis is extended to the cas...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.12.004

    authors: Mitri FG,Fellah ZE

    更新日期:2011-07-01 00:00:00

  • Dependence of sonochemical luminescence on various sound fields

    abstract::To understand the effect of the sound field on sonochemical luminescence, the exact sound pressure must be determined in each field. In this study it was determined by the Shlieren method, which measures the sound pressure without mixing the sound fields. We compared the efficiency of the sonochemical luminescence in ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00203-6

    authors: Yanagida H,Masubuchi Y,Minagawa K,Takimoto J,Ogata T,Koyama K

    更新日期:2000-03-01 00:00:00

  • Inversion algorithm for Lamb-wave-based depth characterization of acoustic emission sources in plate-like structures.

    abstract::An inversion algorithm (termed AEDep) is proposed for estimating the depth of acoustic emission (AE) sources in plate-like structural components. The work is motivated by the need for characterizing early-stage fatigue crack growth in such components. The algorithm achieves depth estimation by automatically extracting...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105975

    authors: Dubuc B,Ebrahimkhanlou A,Livadiotis S,Salamone S

    更新日期:2019-11-01 00:00:00

  • The echocardiophone: a new means for observing spatial movement of the heart.

    abstract::The paper describes a new pocket size instrument called the "Cardiophone" for the diagnosis of cardiac dysfunction. It is a continuous wave swept frequency ultrasonic echo-location system which produces dynamic auditory signals corresponding to the positional change of internal structures of the heart. The four valves...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(77)90031-2

    authors: Kay L,Boys J,Clark G,Mason J

    更新日期:1977-05-01 00:00:00

  • Multibubble sonoluminescence enhancement by fluid flow.

    abstract::Forced fluid flow can cause the enhancement of multibubble sonoluminescence (SL) under suitable conditions. The effect of directional flow with a circulator is similar to that of rotating flow with a stirrer. The mechanism of the enhancement is that both flows prevent cavitation bubbles from coalescing and clustering,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.022

    authors: Hatanaka S,Mitome H,Yasui K,Hayashi S

    更新日期:2006-12-22 00:00:00

  • Excitation and detection of evanescent acoustic waves in piezoelectric plates: Theoretical and 2D FEM modeling.

    abstract::This paper presents the results of the theoretical and 2D FEM modeling excitation and detection of evanescent acoustic waves in piezoelectric plates. By application of 2D ordinary differential equations derived by Auld, we obtained the dispersion curves of A1 and SH1 waves in YX LiNbO3 and YX KNbO3 plates in proximity...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105961

    authors: Kuznetsova I,Nedospasov I,Smirnov A,Qian ZH,Wang B,Dai XY

    更新日期:2019-11-01 00:00:00

  • The applicability of a material-treatment laser pulse in non-destructive evaluations.

    abstract::A practical optodynamic study was performed to determine the usability of different lengths of laser pulses for the generation of ultrasonic transients in a solid material. The aim of the study was to evaluate the possibility of a dual use for a laser pulse-for laser material processing, on the one hand, and for the u...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.071

    authors: Hrovatin R,Petkovsek R,Diaci J,Mozina J

    更新日期:2006-12-22 00:00:00

  • Ultrasonic modification of experimental bruising in the guinea-pig pinna.

    abstract::Both pinnae of anaesthetized male guinea-pigs were contused in a reproducible manner and one immediately treated with 0.75 MHz ultrasound at an average therapeutic intensity of 0.61 W cm-2 for a period of 2 min. The lividity and rate of resorption of the rusultant bruises were measured by a photometric method. The res...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(78)90021-5

    authors: Hustler JE,Zarod AP,Williams AR

    更新日期:1978-09-01 00:00:00

  • Scattering of Airy elastic sheets by a cylindrical cavity in a solid.

    abstract::The prediction of the elastic scattering by voids (and cracks) in materials is an important process in structural health monitoring, phononic crystals, metamaterials and non-destructive evaluation/imaging to name a few examples. Earlier analytical theories and numerical computations considered the elastic scattering b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.06.010

    authors: Mitri FG

    更新日期:2017-11-01 00:00:00

  • Quantification of guided mode propagation in fractured long bones.

    abstract::Guided modes propagation in intact, fractured and healing long bone has drawn significant research interests. However, mode quantifications for the direct comparison are still necessary to address. The aim of the study is to analyze the mode interaction with a notch-fracture in the long bone and find quantitative ultr...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.015

    authors: Xu K,Liu D,Ta D,Hu B,Wang W

    更新日期:2014-07-01 00:00:00

  • Ultrasound in arc welding: a review.

    abstract::During the last decade, the introduction of ultrasound techniques in arc welding with the intention of improving the operational performance and technical characteristics of the welding processes have been studied intensively. In this work is presented a broad review of the literature surrounding the utilization of th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.10.007

    authors: da Cunha TV,Bohórquez CE

    更新日期:2015-02-01 00:00:00

  • Research interface on a programmable ultrasound scanner.

    abstract:MOTIVATION:Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. OBJECTIVES:Recently, we developed a flexible ultrasound back-end where all th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.11.009

    authors: Shamdasani V,Bae U,Sikdar S,Yoo YM,Karadayi K,Managuli R,Kim Y

    更新日期:2008-07-01 00:00:00

  • SH wave propagation in magnetic-electric periodically layered plates.

    abstract::In this paper, dispersive behavior and band structure of SH waves in magnetic-electric (ME) periodically layered plate are investigated by the transfer matrix method. Two kinds of unit cell form, one is piezoelectric (PE)/piezomagnetic (PM)/PE, and the other is PM/PE/PM, are considered in detailed. A peculiar case of ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.01.015

    authors: Pang Y,Gao JS,Liu JX

    更新日期:2014-07-01 00:00:00

  • Experimental study of the influence of different resonators on thermoacoustic conversion performance of a thermoacoustic-Stirling heat engine.

    abstract::In this paper, an experimental study of the effect of the resonator shape on the performance of a traveling-wave thermoacoustic engine is presented. Two different resonators were tested in the thermoacoustic-Stirling heat. One resonator is an iso-diameter one, and the other is a tapered one. To have a reasonable compa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.08.008

    authors: Luo EC,Ling H,Dai W,Yu GY

    更新日期:2006-12-22 00:00:00

  • The design of a high power ultrasonic test cell using finite element modelling techniques.

    abstract::This paper will describe the application of a finite element (FE) code to design a test cell, in which a single transducer is used to generate acoustic cavitation. The FE model comprises a 2-D slice through the centre of the test cell and was used to evaluate the generated pressure fields as a function of frequency. I...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00453-5

    authors: Gachagan A,Speirs D,McNab A

    更新日期:2003-06-01 00:00:00

  • SH ultrasonic guided waves for the evaluation of interfacial adhesion.

    abstract::Shear-Horizontally (SH) polarized, ultrasonic, guided wave modes are considered in order to infer changes in the adhesive properties at several interfaces located within an adhesive bond joining two metallic plates. Specific aluminium lap-joint samples were produced, with different adhesive properties at up to four in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.002

    authors: Castaings M

    更新日期:2014-09-01 00:00:00