An uncovered risk factor of sonothrombolysis: Substantial fluctuation of ultrasound transmittance through the human skull.

Abstract:

:Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. Previously, we reported substantial and periodic fluctuation of ultrasound transmittance through a bone-phantom plate following changes to ultrasound frequency, the thickness of the bone-phantom plate, and the distance between a transducer and the bone-phantom plate. In the present study, we clarify the transmittance behavior of medium-frequency ultrasound (from 400kHz to 600kHz) through the human skull, and examine reduction of the transmittance fluctuation. For the study, we measured transmittance of sinusoidal ultrasound waves at 400kHz, 500kHz, and 600kHz at 13 temple spots on 3 human skulls by changing the distance between a transducer and the skull bone, and found substantial and periodic fluctuation in the transmittance behaviors for these sinusoidal voltage excitations. Degrees of the fluctuation varied depending on the measurement spots. A fluctuation ratio between the maximum transmittance and the minimum transmittance reached 3 in some spots. This large transmittance fluctuation is considered to be a risk factor for sonothrombolysis therapies. We examined a modulated ultrasound wave to reduce the fluctuation, and succeeded in obtaining considerable reduction. The average fluctuation ratios for 400-kHz, 500-kHz, and 600-kHz waves were 2.38, 2.38, and 2.07, respectively. We successfully reduced the ratio to 1.72 by using a periodic selection of random frequency (PSRF)-type of modulation wave. The thus obtained results indicate that attention to the fluctuation in ultrasound transmittance through the skull is necessary for safe and effective sonothrombolysis therapies, and that modulated ultrasound waves constitute a powerful method for reducing the risk of fluctuation.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Wang Z,Komatsu T,Mitsumura H,Nakata N,Ogawa T,Iguchi Y,Yokoyama M

doi

10.1016/j.ultras.2017.02.012

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

168-175

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(17)30150-6

journal_volume

77

pub_type

杂志文章
  • Sound field separating on arbitrary surfaces enclosing a sound scatterer based on combined integral equations.

    abstract::To eliminate the limitations of the conventional sound field separation methods which are only applicable to regular surfaces, a sound field separation method based on combined integral equations is proposed to separate sound fields directly in the spatial domain. In virtue of the Helmholtz integral equations for the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.06.007

    authors: Fan Z,Mei D,Yang K,Chen Z

    更新日期:2014-12-01 00:00:00

  • Feature selection for neural network based defect classification of ceramic components using high frequency ultrasound.

    abstract::The motivation for this research stems from a need for providing a non-destructive testing method capable of detecting and locating any defects and microstructural variations within armour ceramic components before issuing them to the soldiers who rely on them for their survival. The development of an automated ultras...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.05.027

    authors: Kesharaju M,Nagarajah R

    更新日期:2015-09-01 00:00:00

  • Eight-channel ultrasonic device for non-invasive quality evaluation in packed milk.

    abstract::An eight-channel ultrasonic detecting device for microbiological quality evaluation of packed liquid foods is presented in this paper. This device makes possible a non-invasive detection of the microbial growth in liquid foods with no need to open the carton-based packages where they are contained. Thermal and humidit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.011

    authors: Elvira L,Sampedro L,Montero de Espinosa F,Matesanz J,Gómez-Ullate Y,Resa P,Echevarría FJ,Iglesias JR

    更新日期:2006-12-01 00:00:00

  • Annular phased array transducer for preclinical testing of anti-cancer drug efficacy on small animals.

    abstract::A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.12.008

    authors: Kujawska T,Secomski W,Byra M,Postema M,Nowicki A

    更新日期:2017-04-01 00:00:00

  • Non-contact measurement of the thickness of a surface film using a superimposed ultrasonic standing wave.

    abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106291

    authors: Kanja J,Mills R,Li X,Brunskill H,Hunter AK,Dwyer-Joyce RS

    更新日期:2021-02-01 00:00:00

  • A new optical method for the detection of in-plane motion of ultrasound propagating in metals.

    abstract::This paper describes a laser optical technique for the detection of in-plane (IP) motion of ultrasonic waves propagating in solids. This interference-based laser optical technique includes a tiny square indentation with a width of about 30 microm on the sample surface and a relatively simple optical arrangement. The c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.076

    authors: Yang CH,Tsai YC

    更新日期:2006-12-22 00:00:00

  • The analysis of the effect of homogeneous mechanical stress on the acoustic wave propagation in the "La3Ga5SiO14/fused silica" piezoelectric layered structure.

    abstract::The results of computer simulation taking into account the linear and nonlinear material constants have been presented. Study of the influence of external uniaxial mechanical stress on the dispersive characteristics of elastic waves in piezoelectric structures as "La3Ga5SiO14/fused silica" has been executed. The compa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.07.007

    authors: Burkov SI,Zolotova OP,Sorokin BP,Turchin PP

    更新日期:2015-01-01 00:00:00

  • A new beamforming method and hardware architecture for real time two way dynamic depth focusing.

    abstract::The Total Focusing Method (TFM) yields a focused image in emission and in reception while Phased Array (PA) imaging provides Dynamic Depth Focusing (DDF) in reception only. Besides, most NDE applications have two propagation media, where refraction at the interface complicates time-of-flight (TOF) and focal law comput...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105965

    authors: Cruza JF,Camacho J,Mateos R,Fritsch C

    更新日期:2019-11-01 00:00:00

  • Y-shaped jets driven by an ultrasonic beam reflecting on a wall.

    abstract::This paper presents an original experimental and numerical investigation of acoustic streaming driven by an acoustic beam reflecting on a wall. The water experiment features a 2 MHz acoustic beam totally reflecting on one of the tank glass walls. The velocity field in the plane containing the incident and reflected be...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.02.003

    authors: Moudjed B,Botton V,Henry D,Millet S,Ben Hadid H

    更新日期:2016-05-01 00:00:00

  • Automated quantitative analysis of the shift of frequency spectra generated by attenuated signals from contrast microbubbles.

    abstract::The ultrasound-induced harmonic microbubble response spectrum is known to shift to lower frequencies with increasing tissue attenuation. We hypothesized that this shift could be reproducibly detected in received broadband radiofrequency spectra. We used an automatic Gaussian curve-fitting technique to measure the mean...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00397-9

    authors: Bartleson VB,Viggen K,Asanuma T,Kinnick RR,Belohlavek M

    更新日期:2003-03-01 00:00:00

  • Absence of biological damage from prolonged exposure to intravascular ultrasound: a swine model.

    abstract::Ultrasound (US) has been used in IMS II (intravascular US) and CLOTBUST (transcranial US) clinical trials for thrombolysis. During the treatment, in addition to the targeted thrombus, other biological components, such as blood and vessel walls are subjected to long durations of US exposure. In this study we explored e...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.10.004

    authors: Soltani A,Singhal R,Garcia JL,Raju NR

    更新日期:2007-03-01 00:00:00

  • Investigating the absolute phase information in acoustic wave resonance scattering.

    abstract::The aim of this work is to investigate the absolute phase information in resonance acoustic scattering by spheres and cylinders and place this work in the broader context of scattering in which the properties of the magnitude and (processed) phase have been examined in a more general way than in the classical resonanc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.01.002

    authors: Mitri FG,Greenleaf JF,Fellah ZE,Fatemi M

    更新日期:2008-07-01 00:00:00

  • Quantification of elasticity changes in the myometrium during labor using Supersonic Shear Imaging: a feasibility study.

    abstract::Very little is known about the myometrium's physiology in terms of its elasticity but shear wave elastography could be an efficient tool to better understand it. This could considerably help the prevention of difficult births, the consequences of which are tremendous for neonate morbidity and pathologies. The purpose ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.07.013

    authors: Gennisson JL,Muller M,Gabor P,Frydman R,Musset D,Tanter M,Ami O

    更新日期:2015-02-01 00:00:00

  • Current topics on sonoelectrochemistry.

    abstract::Sonoelectrochemistry is undergoing a reemerging activity in the last years with an increasing number of papers appearing in a wide range of peer review journals. Applied studies which cover environmental treatments, synthesis or characterization of nanostructures, polymeric materials synthesis, analytical procedures, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.022

    authors: González-García J,Esclapez MD,Bonete P,Hernández YV,Garretón LG,Sáez V

    更新日期:2010-02-01 00:00:00

  • Optimal working frequency of ultrasonic motors.

    abstract::In this work, the existence of the optimal working frequency for ultrasonic motors (USMs) is theoretically and experimentally verified for the first time, at which working point the power dissipation of the motors arrives at its minimum value. The mathematical model of the mechanical quality factor is initially deduce...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.015

    authors: Shi W,Zhao H,Ma J,Yao Y

    更新日期:2016-08-01 00:00:00

  • Acousto-optic interaction with leaky surface acoustic waves in Y-cut LiTaO3 crystals.

    abstract::The acousto-optic interaction with leaky surface acoustic wave radiation into the bulk of YX-cut LiTaO(3) crystals has been investigated. The light incidence and diffraction angles corresponding to the strongest acousto-optic interaction were calculated and measured as functions of the acoustic wave frequency. The dep...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.12.004

    authors: Belovickis J,Rimeika R,Ciplys D

    更新日期:2012-07-01 00:00:00

  • Biomechanical characterization of ex vivo human brain using ultrasound shear wave spectroscopy.

    abstract::The characterization of brain tissue is crucial to better understand neurological disorders. Mechanical characterization is an emerging tool in that field. The purpose of this work was to validate a transient ultrasound technique aimed at measuring dispersion of mechanical parameters of the brain tissue. The first par...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.10.009

    authors: Nicolas E,Callé S,Nicolle S,Mitton D,Remenieras JP

    更新日期:2018-03-01 00:00:00

  • Experimental estimation of the viscous component of ultrasound attenuation in suspensions of bovine skeletal muscle myofibrils.

    abstract::It has been suggested that viscous losses, caused by the motion of myofibrils relative to their environmental fluid, could be the major cause of ultrasound attenuation in muscle. This Paper presents theoretical and experimental estimates of the viscous component of attenuation in suspensions of myofibrils. Experimenta...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(88)90046-7

    authors: Shore D,Miles CA

    更新日期:1988-01-01 00:00:00

  • Guided waves in anisotropic and quasi-isotropic aerospace composites: three-dimensional simulation and experiment.

    abstract::Three-dimensional (3D) elastic wave simulations can be used to investigate and optimize nondestructive evaluation (NDE) and structural health monitoring (SHM) ultrasonic damage detection techniques for aerospace materials. 3D anisotropic elastodynamic finite integration technique (EFIT) has been implemented for ultras...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.05.007

    authors: Leckey CA,Rogge MD,Raymond Parker F

    更新日期:2014-01-01 00:00:00

  • Application of the ultrasonic waves in structural investigation of ferrofluid.

    abstract::It has been established that structural changes in a ferrofluid (formation of clusters) upon the effect of an external magnetic field can be effectively studied by ultrasound spectroscopy. In particular, the resonance absorption of ultrasonic waves enables detection and determination of the size of spherical clusters....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00117-8

    authors: Józefczak A,Skumiel A,Hornowski T

    更新日期:2002-05-01 00:00:00

  • Characterization of air-coupled ultrasound transducers in the frequency range 40 kHz-2 mHz using light diffraction tomography.

    abstract::The aim of this work was to show the applicability of light diffraction tomography on airborne ultrasound in the frequency range 40 kHz-2 MHz. Seven different air-coupled transducers were measured to show the method's performance regarding linearity, absolute pressure measurements, phase measurements, frequency respon...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00168-7

    authors: Almqvist M,Holm A,Persson HW,Lindström K

    更新日期:2000-01-01 00:00:00

  • A novel approach to quantitative ultrasonic naked gene delivery and its non-invasive assessment.

    abstract::The purpose of this study was to investigate practical, safe, easy-to-use, non-cytotoxic, and reliable parameters to apply to an ultrasound (US) naked gene therapy system. The ultrasound pressure at the point of cell exposure was measured using a calibrated hydrophone and the intensity calculated. An acoustic power me...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.06.007

    authors: Wei W,Zhengzhong B,Yongjie W,Lafeng Y,Yalin M

    更新日期:2004-12-01 00:00:00

  • Quantitative colour-ultrasonography by means of a computer aided simultaneous tomogram.

    abstract::In this newly developed method, the ultrasonic diagnosis has become quantitative. The data will remain quantitative so far as an image storage tube is used. With the conventional storage type CRT, it is impossible to memorize the reflected echo signals of different strength levels. But with our method, it becomes poss...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(75)90036-0

    authors: Yokoi H,Tatsumi T,Ito K

    更新日期:1975-09-01 00:00:00

  • Sparsity-based beamforming to enhance two-dimensional linear-array photoacoustic tomography.

    abstract::In linear-array photoacoustic imaging (PAI), beamforming methods can be used to reconstruct the images. Delay-and-sum (DAS) beamformer is extensively used due to its simple implementation. However, this algorithm results in high level of sidelobes and low resolution. In this paper, it is proposed to form the photoacou...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.03.010

    authors: Paridar R,Mozaffarzadeh M,Periyasamy V,Pramanik M,Mehrmohammadi M,Orooji M

    更新日期:2019-07-01 00:00:00

  • Investigation of diamond wheel topography in Elliptical Ultrasonic Assisted Grinding (EUAG) of monocrystal sapphire using fractal analysis method.

    abstract::The wear behaviors of grinding wheel have significant influence on the work-surface topography. However, a comprehensive and quantitative method is lacking for evaluating the wear conditions of grinding wheel. In this paper, a fractal analysis method is used to investigate the wear behavior of resin-bonded diamond whe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.10.012

    authors: Wang Q,Zhao W,Liang Z,Wang X,Zhou T,Wu Y,Jiao L

    更新日期:2018-03-01 00:00:00

  • Some studies on evaluation of degradation in composite adhesive joints using ultrasonic techniques.

    abstract::Experimental and theoretical studies on degradation of composite-epoxy adhesive joints were carried out on samples having different interfacial and cohesive properties. Oblique incidence ultrasonic inspection of bonded joints revealed that degradation in the adhesive can be measured by significant variation in reflect...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.01.014

    authors: Vijaya Kumar RL,Bhat MR,Murthy CR

    更新日期:2013-08-01 00:00:00

  • Influence of extrinsic operational parameters on salt diffusion during ultrasound assisted meat curing.

    abstract::The present study investigated the effect of geometric parameters of the ultrasound instrument during meat salting in order to enhance salt diffusion and salt distribution in pork meat on a lab scale. The effects of probe size (∅2.5 and 1.3cm) and of different distances between the transducer and the meat sample (0.3,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.017

    authors: Inguglia ES,Zhang Z,Burgess C,Kerry JP,Tiwari BK

    更新日期:2018-02-01 00:00:00

  • Ultrasonic strain imaging and reconstructive elastography for biological tissue.

    abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.007

    authors: Khaled W,Reichling S,Bruhns OT,Ermert H

    更新日期:2006-12-22 00:00:00

  • Propagation of elastic waves through two-dimensional lattices of cylindrical empty or water-filled inclusions in an aluminum matrix.

    abstract::The layer-multiple-scattering method is developed to study wave propagation through two-dimensional lattices of cylindrical inclusions in an elastic medium. The lattices are a series of periodically spaced infinite one-dimensional periodic gratings (or rows) of inclusions. The layer-multiple-scattering method allows t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.002

    authors: Robert S,Conoir JM,Franklin H

    更新日期:2006-12-01 00:00:00

  • Baseline subtraction technique in the frequency-wavenumber domain for high sensitivity damage detection.

    abstract::This paper suggests a method for high-sensitivity damage detection. The method is based on pitch-catch measurements of Lamb waves combined with a baseline subtraction technique in the frequency-wavenumber domain. Small amplitude converted modes, generated during the interaction of propagating waves with damage, can th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.08.010

    authors: McKeon P,Yaacoubi S,Declercq NF,Ramadan S,Yaacoubi WK

    更新日期:2014-02-01 00:00:00