Experimental estimation of the viscous component of ultrasound attenuation in suspensions of bovine skeletal muscle myofibrils.

Abstract:

:It has been suggested that viscous losses, caused by the motion of myofibrils relative to their environmental fluid, could be the major cause of ultrasound attenuation in muscle. This Paper presents theoretical and experimental estimates of the viscous component of attenuation in suspensions of myofibrils. Experimental estimates were made by monitoring the effects of varying the viscosity and density of the suspending fluid and ranged from 0.55 to 0.72 cm2 g-1 protein at 7 MHz, when expressed as mass attenuation coefficients. This represented 16-22% of the total attenuation measured in suspensions. Corresponding theoretical calculations were lower: 0.44 and 0.21 cm2 g-1 protein, respectively, for suspensions with the myofibrils aligned along and across the direction of sound propagation. It was concluded that most of the attenuation was caused by other absorption processes.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Shore D,Miles CA

doi

10.1016/0041-624x(88)90046-7

subject

Has Abstract

pub_date

1988-01-01 00:00:00

pages

31-6

issue

1

eissn

0041-624X

issn

1874-9968

pii

0041-624X(88)90046-7

journal_volume

26

pub_type

杂志文章
  • Nonlinear coda wave interferometry for the global evaluation of damage levels in complex solids.

    abstract::A nonlinear acoustic method to assess the damage level of a complex medium is discussed herein. Thanks to the highly nonlinear elastic signatures of cracks or, more generally, internal solid contacts, this method is able to distinguish between contributions from linear wave scattering by a heterogeneity and contributi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.09.015

    authors: Zhang Y,Tournat V,Abraham O,Durand O,Letourneur S,Le Duff A,Lascoup B

    更新日期:2017-01-01 00:00:00

  • An uncovered risk factor of sonothrombolysis: Substantial fluctuation of ultrasound transmittance through the human skull.

    abstract::Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. P...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.012

    authors: Wang Z,Komatsu T,Mitsumura H,Nakata N,Ogawa T,Iguchi Y,Yokoyama M

    更新日期:2017-05-01 00:00:00

  • Understanding the effect of methane gas sensitivity using ultrasonic sensors and multi-matching layers inside a natural gas vehicle tank.

    abstract::This research paper is the experimental study to investigate the effect of ultrasound sensitivity in the pure methane gas space as the pressure and sensor distance increases. We offer the solution to overcome the low sensitivity characteristics of ultrasonic sensors in the methane gas space. This proposal shows the ph...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105970

    authors: Kim K,Choi D,Im S

    更新日期:2019-11-01 00:00:00

  • Automated quantitative analysis of the shift of frequency spectra generated by attenuated signals from contrast microbubbles.

    abstract::The ultrasound-induced harmonic microbubble response spectrum is known to shift to lower frequencies with increasing tissue attenuation. We hypothesized that this shift could be reproducibly detected in received broadband radiofrequency spectra. We used an automatic Gaussian curve-fitting technique to measure the mean...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00397-9

    authors: Bartleson VB,Viggen K,Asanuma T,Kinnick RR,Belohlavek M

    更新日期:2003-03-01 00:00:00

  • Reconstruction of ultrasonic fields by deconvolving the hydrophone aperture effects. I. Theory and simulation.

    abstract::In many ultrasound applications-especially in the area of medical diagnostics-conventional sensors and particularly piezoelectric hydrophones do not comply with the requirements for "point detectors". It therefore suggests itself to develop methods, which allow ultrasonic fields to be reconstructed from the spatially ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00346-3

    authors: Boutkedjirt T,Reibold R

    更新日期:2002-08-01 00:00:00

  • Feature selection for neural network based defect classification of ceramic components using high frequency ultrasound.

    abstract::The motivation for this research stems from a need for providing a non-destructive testing method capable of detecting and locating any defects and microstructural variations within armour ceramic components before issuing them to the soldiers who rely on them for their survival. The development of an automated ultras...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.05.027

    authors: Kesharaju M,Nagarajah R

    更新日期:2015-09-01 00:00:00

  • Surface and friction characterization by thermoelectric measurements during ultrasonic friction processes

    abstract::Even though friction is one of the oldest problems in physics many aspects of friction processes are not clear today. We present an experimental setup, which permits the study of tribological systems by measuring the dissipated heat at the interface of two surfaces during a friction process with a time resolution of 1...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00062-1

    authors: Schwaller P,Groning P,Schneuwly A,Boschung P,Muller E,Blanc M,Schlapbach L

    更新日期:2000-03-01 00:00:00

  • Ultrasonic spectroscopy of pure cyclic compounds.

    abstract::Ultrasonic studies of the group of halogens of benzene and particularly dependence of acoustic parameters on the structure of organic liquids, demonstrate some interesting regularities in the group of these compounds in gas and liquid states. In this paper results for five cyclic liquids: bromo-, chloro-, fluoro- and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.146

    authors: Linde BB,Lezhnev NB

    更新日期:2006-12-22 00:00:00

  • Screen-printed ultrasonic 2-D matrix array transducers for microparticle manipulation.

    abstract::This paper reports the development of a two-dimensional thick film lead zirconate titanate (PZT) ultrasonic transducer array, operating at frequency approximately 7.5MHz, to demonstrate the potential of this fabrication technique for microparticle manipulation. All layers of the array are screen-printed then sintered ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.05.010

    authors: Qiu Y,Wang H,Gebhardt S,Bolhovitins A,Démoré CE,Schönecker A,Cochran S

    更新日期:2015-09-01 00:00:00

  • Microparticle manipulation in millimetre scale ultrasonic standing wave chambers.

    abstract::Ultrasonic standing wave chambers with acoustic pathlengths of 1.1 and 0.62 mm have been constructed. The chambers were driven at frequencies over the range 0.66-12.2 MHz. The behaviour of 2 microns diameter latex microparticles and 5 microns diameter yeast in the chambers has been elucidated. One (flow) chamber had a...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(98)00019-5

    authors: Hawkes JJ,Barrow D,Coakley WT

    更新日期:1998-08-01 00:00:00

  • Amplitude degradation of time-reversed pulses in nonlinear absorbing thermoviscous fluids.

    abstract::The linear wave equation in a lossless medium is time reversible, i.e., every solution p(x, t) has a temporal mirror solution p(x, -t). Analysis shows that time reversal also holds for the lossless nonlinear wave equation. In both cases, time-reversal invariance is violated when losses are present. For nonlinear propa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00020-2

    authors: Hallaj IM,Cleveland R0,Barbone PE,Kargl SG,Roy RA

    更新日期:2000-09-01 00:00:00

  • Experiment and numerical simulation for laser ultrasonic measurement of residual stress.

    abstract::Laser ultrasonic is a most promising method for non-destructive evaluation of residual stress. The residual stress of thin steel plate is measured by laser ultrasonic technique. The pre-stress loading device is designed which can easily realize the condition of the specimen being laser ultrasonic tested at the same ti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.08.013

    authors: Zhan Y,Liu C,Kong X,Lin Z

    更新日期:2017-01-01 00:00:00

  • Volume reconstruction of freehand three-dimensional ultrasound using median filters.

    abstract:OBJECTIVES:This paper aims to apply median filters for reducing interpolation error and improving the quality of 3D images in a freehand 3D ultrasound (US) system. BACKGROUND AND MOTIVATION:Freehand 3D US imaging has been playing an important role in obtaining the entire 3D impression of tissues and organs. Reconstruc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.11.005

    authors: Huang QH,Zheng YP

    更新日期:2008-07-01 00:00:00

  • Induction of stress fibres and intercellular gaps in human vascular endothelium by shock-waves.

    abstract::Human umbilical cords were exposed to high amplitude focussed ultrasonic pulses with focal energy densities 0.6 and 0.4 mJ mm-2. The endothelium of the exposed vessel (vein) was examined by means of confocal laser scanning microscopy and scanning electron microscopy. The degree of tissue change ranged from the inducti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(94)90111-2

    authors: Seidl M,Steinbach P,Wörle K,Hofstädter F

    更新日期:1994-09-01 00:00:00

  • Detecting broken-wire flaws at multiple locations in the same wire of prestressing strands using guided waves.

    abstract::Broken wires often occur at multiple locations in the same wire of a strand due to the recovery length, which is defined as the length of the wire taking up its full share of the axial load from the break point. The detection of broken-wire flaws at multiple locations along the same wire is investigated using guided w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.003

    authors: Xu J,Wu X,Sun P

    更新日期:2013-01-01 00:00:00

  • Inline ultrasonic rheometry by pulsed Doppler.

    abstract::This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.027

    authors: Pfund DM,Greenwood MS,Bamberger JA,Pappas RA

    更新日期:2006-12-22 00:00:00

  • 2D array design based on Fermat spiral for ultrasound imaging.

    abstract::The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.010

    authors: Martínez-Graullera O,Martín CJ,Godoy G,Ullate LG

    更新日期:2010-02-01 00:00:00

  • Quantification of guided mode propagation in fractured long bones.

    abstract::Guided modes propagation in intact, fractured and healing long bone has drawn significant research interests. However, mode quantifications for the direct comparison are still necessary to address. The aim of the study is to analyze the mode interaction with a notch-fracture in the long bone and find quantitative ultr...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.015

    authors: Xu K,Liu D,Ta D,Hu B,Wang W

    更新日期:2014-07-01 00:00:00

  • The computations of reflection coefficients of multilayer structure based on the reformulation of Thomson-Haskell method.

    abstract::A reformulation of the Thomson-Haskell method is presented for calculating the reflection coefficients of multilayer structure immersing in the coupling fluid. Instead of directly multiplying the layer propagator matrix, the new method splits the layer propagator matrix and excursively determines the interface stiffne...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.08.004

    authors: Chen J,Bai X,Yang K,Ju BF

    更新日期:2012-12-01 00:00:00

  • Torsional ultrasonic transducer computational design optimization.

    abstract::A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predomina...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.05.001

    authors: Melchor J,Rus G

    更新日期:2014-09-01 00:00:00

  • Interior dynamics of subharmonious surface wave in an idealized bidimensional granular layer.

    abstract::In this paper, high-speed photography was used to investigate the intrinsic dynamics of subharmonious surface wave in a vertical vibrated and idealized bidimensional granular layer. Using the high-speed photography, velocity fields of the granular layer at different stages through two cycles were obtained, which show ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.196

    authors: Zhang P,Huang K,Miao G,Wei R

    更新日期:2006-12-22 00:00:00

  • Dynamic interrogator for elastic wave sensing using Fabry Perot filters based on fiber Bragg gratings.

    abstract::Use of in-fiber Fabry-Perot (FP) filters based on fiber Bragg gratings as both sensor as well as an interrogator for enhancing the detection limit of elastic wave sensing is investigated in this paper. The sensitivity of such a demodulation scheme depends on the spectral discrimination of the sensor and interrogator g...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.02.018

    authors: Harish AV,Varghese B,Rao B,Balasubramaniam K,Srinivasan B

    更新日期:2015-07-01 00:00:00

  • Non-linear actuation of cantilevers using giant magnetostrictive thin films

    abstract::In the present paper, we report the first results concerning a centimetre cantilever driven through non-linear effects in thin magnetostrictive films. Bimorph centimetre beams (24 mm x 5 mm) were designed using 160 microns thick glass and 0.4 micron thick multilayer TbFe/Fe films deposited via RF sputtering, using sev...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00061-x

    authors: Tiercelin N,Pernod P,Preobrazhensky V V,Le Gall H,Ben Youssef J

    更新日期:2000-03-01 00:00:00

  • Axial acoustic radiation force of progressive cylindrical diverging waves on a rigid and a soft cylinder immersed in an ideal compressible fluid.

    abstract:BACKGROUND AND MOTIVATION:Previous works investigating the radiation force of diverging spherical progressive waves incident upon spherical particles have demonstrated the direction of reversal of the force when the particle is subjected to a curved wave-front. In this communication, the analysis is extended to the cas...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.12.004

    authors: Mitri FG,Fellah ZE

    更新日期:2011-07-01 00:00:00

  • Nonlinear standing waves in 2-D acoustic resonators.

    abstract::This paper deals with 2-D simulation of finite-amplitude standing waves behavior in rectangular acoustic resonators. Set of three partial differential equations in third approximation formulated in conservative form is derived from fundamental equations of gas dynamics. These equations form a closed set for two compon...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.008

    authors: Cervenka M,Bednarik M

    更新日期:2006-12-22 00:00:00

  • Acousto-optic interaction with leaky surface acoustic waves in Y-cut LiTaO3 crystals.

    abstract::The acousto-optic interaction with leaky surface acoustic wave radiation into the bulk of YX-cut LiTaO(3) crystals has been investigated. The light incidence and diffraction angles corresponding to the strongest acousto-optic interaction were calculated and measured as functions of the acoustic wave frequency. The dep...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.12.004

    authors: Belovickis J,Rimeika R,Ciplys D

    更新日期:2012-07-01 00:00:00

  • Effect of spatial dispersion on transient acoustic wave propagation in 3D.

    abstract::Spatial dispersion is the variation of wave speed with wavelength. It sets in when the acoustic wavelength approaches the natural scale of length of the medium, which could, for example, be the lattice constant of a crystal, the repeat distance in a superlattice, or the grain size in a granular material. In centrosymm...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.215

    authors: Every AG

    更新日期:2006-12-22 00:00:00

  • Ultrasonic flaw detection using threshold modified S-transform.

    abstract::Interference noising originating from the ultrasonic testing defect signal seriously influences the accuracy of the signal extraction and defect location. Time-frequency analysis methods are mainly used to improve the defects detection resolution. In fact, the S-transform, a hybrid of the Short time Fourier transform ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.004

    authors: Benammar A,Drai R,Guessoum A

    更新日期:2014-02-01 00:00:00

  • Depth-of-field enhancement in Filtered-Delay Multiply and Sum beamformed images using Synthetic Aperture Focusing.

    abstract::The Synthetic Aperture Focusing (SAF) technique makes it possible to achieve a higher and more uniform quality of ultrasound images throughout depth, as if both transmit and receive dynamic focusing were applied. In this work we combine a particular implementation of SAF, called Synthetic Transmit Aperture (STA) techn...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.022

    authors: Matrone G,Savoia AS,Caliano G,Magenes G

    更新日期:2017-03-01 00:00:00

  • Y-shaped jets driven by an ultrasonic beam reflecting on a wall.

    abstract::This paper presents an original experimental and numerical investigation of acoustic streaming driven by an acoustic beam reflecting on a wall. The water experiment features a 2 MHz acoustic beam totally reflecting on one of the tank glass walls. The velocity field in the plane containing the incident and reflected be...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.02.003

    authors: Moudjed B,Botton V,Henry D,Millet S,Ben Hadid H

    更新日期:2016-05-01 00:00:00