Micromachined ultrasound transducers with improved coupling factors from a CMOS compatible process

Abstract:

:For medical high frequency acoustic imaging purposes the reduction in size of a single transducer element for one-dimensional and even more for two-dimensional arrays is more and more limited by fabrication and cabling technology. In the fields of industrial distance measurement and simple object recognition low cost phased arrays are lacking. Both problems can be solved with micromachined ultrasound transducers (MUTs). A single transducer is made of a large number of microscopic elements. Because of the array structure of these transducers, groups of elements can be built up and used as a phased array. By integrating parts of the sensor electronics on chip, the cabling effort for arrays can be reduced markedly. In contrast to standard ultrasonic technology, which is based on massive thickness resonators, vibrating membranes are the radiating elements of the MUTs. New micromachining technologies have emerged, allowing a highly reproducible fabrication of electrostatically driven membranes with gap heights below 500 nm. A microelectronic BiCMOS process was extended for surface micromechanics (T. Scheiter et al., Proceedings 11th European Conference on Solid-State Transducers, Warsaw, Vol. 3, 1997, pp. 1595-1598). Additional process steps were included for the realization of the membranes which form sealed cavities with the underlying substrate. Membrane and substrate are the opposite electrodes of a capacitive transducer. The transducers can be integrated monolithically on one chip together with the driving, preamplifying and multiplexing circuitry, thus reducing parasitic capacities and noise level significantly. Owing to their low mass the transducers are very well matched to fluid loads, resulting in a very high bandwidth of 50-100% (C. Eccardt et al., Proceedings Ultrasonics Symposium, San Antonio, Vol. 2, 1996, pp. 959-962; P.C. Eccardt et al., Proceedings of the 1997 Ultrasonics Symposium, Toronto, Vol. 2, 1997, pp. 1609-1618). In the following it is shown how the BiCMOS process has been modified to meet the demands for ultrasound generation and reception. Bias and driving voltages have been reduced down to the 10 V range. The electromechanical coupling is now almost comparable with that for piezoelectric transducers. The measurements exhibit sound pressures and bandwidths that are at least comparable with those of conventional piezoelectric transducer arrays.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Eccardt PC,Niederer K

doi

10.1016/s0041-624x(99)00085-2

subject

Has Abstract

pub_date

2000-03-01 00:00:00

pages

774-80

issue

1-8

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(99)00085-2

journal_volume

38

pub_type

杂志文章
  • A general model of the axle vibration in piezoelectric motors.

    abstract::In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.080

    authors: Iula A,Pappalardo M

    更新日期:2004-04-01 00:00:00

  • Adaptive filtering for reduction of speckle in ultrasonic pulse-echo images.

    abstract::Current medical ultrasonic scanning instrumentation permits the display of fine image detail (speckle) which does not transfer useful information but degrades the apparent low contrast resolution in the image. An adaptive two-dimensional filter has been developed which uses local features of image texture to recognize...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(86)90072-7

    authors: Bamber JC,Daft C

    更新日期:1986-01-01 00:00:00

  • A nondestructive method for estimation of the fracture toughness of CrMoV rotor steels based on ultrasonic nonlinearity.

    abstract::The objective of this paper is to develop a nondestructive method for estimating the fracture toughness (K(IC)) of CrMoV steels used as the rotor material of steam turbines in power plants. To achieve this objective, a number of CrMoV steel samples were heat-treated, and the fracture appearance transition temperature ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00154-9

    authors: Jeong H,Nahm SH,Jhang KY,Nam YH

    更新日期:2003-09-01 00:00:00

  • Ultrasonic excitation affects friction interactions between food materials and cutting tools.

    abstract::In the food industry, ultrasonic cutting is used to improve separation by a reduction of the cutting force. This reduction can be attributed to the modification of tool-workpiece interactions at the cutting edge and along the tool flanks because of the superposition of the cutting movement with ultrasonic vibration of...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.03.001

    authors: Schneider Y,Zahn S,Schindler C,Rohm H

    更新日期:2009-06-01 00:00:00

  • Extraction and filtering in ultrasonic field: finite element modelling and simulation of the processes

    abstract::In this research, the use of powerful sonification is studied in making the extraction of tannins more efficient. A combined extraction-filtration system using sonification was designed and modelled. Preliminary extraction studies were carried out to show the effect of ultrasound in extraction. In these experiments hi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00163-8

    authors: Mantysalo M,Mantysalo E

    更新日期:2000-03-01 00:00:00

  • An uncovered risk factor of sonothrombolysis: Substantial fluctuation of ultrasound transmittance through the human skull.

    abstract::Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. P...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.012

    authors: Wang Z,Komatsu T,Mitsumura H,Nakata N,Ogawa T,Iguchi Y,Yokoyama M

    更新日期:2017-05-01 00:00:00

  • Nondestructive testing using air-borne ultrasound.

    abstract::Over the last two decades, more efficient transducers were developed for the generation and reception of air-borne ultrasound, thus enabling the non-contact, non-contaminating inspection of composite laminates and honeycomb structures widely used in the aerospace industry. This paper presents the fundamentals of makin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.091

    authors: Hsu DK

    更新日期:2006-12-22 00:00:00

  • Piezoelectric linear motor concepts based on coupling of longitudinal vibrations.

    abstract::Classically, rotary motors with gears and spindle mechanisms are used to achieve translatory motion. In means of miniaturization and weight reduction piezoelectric linear motors are of interest. Several ultrasonic linear motors found in literature base on the use of two different vibration modes. Most often flexural a...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.056

    authors: Hemsel T,Mracek M,Twiefel J,Vasiljev P

    更新日期:2006-12-22 00:00:00

  • Propagation of thickness shear waves in a periodically corrugated quartz crystal plate and its application exploration in acoustic wave filters.

    abstract::The propagation of thickness shear waves in a periodically corrugated quartz crystal plate is investigated in the present paper using a power series expansion technique. In the proposed simulation model, an equivalent continuity of shear stress moment is introduced as an approximation to handle sectional interfaces wi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.004

    authors: Li P,Cheng L

    更新日期:2017-05-01 00:00:00

  • Effect of spatial dispersion on transient acoustic wave propagation in 3D.

    abstract::Spatial dispersion is the variation of wave speed with wavelength. It sets in when the acoustic wavelength approaches the natural scale of length of the medium, which could, for example, be the lattice constant of a crystal, the repeat distance in a superlattice, or the grain size in a granular material. In centrosymm...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.215

    authors: Every AG

    更新日期:2006-12-22 00:00:00

  • Interlaboratory evaluation of hydrophone sensitivity calibration from 0.1 to 2 MHz via time delay spectrometry.

    abstract::Knowing the low-frequency response of hydrophones, down to 100 kHz at least, is important for accurate biomedical ultrasound measurements. However, current international standards do not extend below 500 kHz. Furthermore, commercial hydrophone sources typically do not supply sensitivity data below 1-2 MHz. Therefore, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.008

    authors: Harris GR,Gammell PM,Lewin PA,Radulescu EG

    更新日期:2004-04-01 00:00:00

  • Arbitrary scattering of an acoustical high-order Bessel trigonometric (non-vortex) beam by a compressible soft fluid sphere.

    abstract::The present analysis extends the previous work on the axial acoustic scattering of a high-order Bessel trigonometric beam (HOBTB) from a fluid sphere [F.G. Mitri, J. Appl. Phys. 109 (2011) 014916] to the generalized case of arbitrary scattering from a fluid sphere placed off-axially. The scattered pressure is expresse...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.12.008

    authors: Mitri FG

    更新日期:2013-07-01 00:00:00

  • A new topological structure for the Langevin-type ultrasonic transducer.

    abstract::In this paper, a new topological structure for the Langevin-type ultrasonic transducer is proposed and investigated. The two cylindrical terminal blocks are conically shaped with four supporting plates each, and two cooling fins are disposed at the bottom of terminal blocks, adjacent to the piezoelectric rings. Experi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.008

    authors: Lu X,Hu J,Peng H,Wang Y

    更新日期:2017-03-01 00:00:00

  • A cylindrical standing wave ultrasonic motor using bending vibration transducer.

    abstract::A cylindrical standing wave ultrasonic motor using bending vibration transducer was proposed in this paper. The proposed stator contains a cylinder and a bending vibration transducer. The two combining sites between the cylinder and the transducer locate at the adjacent wave loops of bending vibration of the transduce...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.12.007

    authors: Liu Y,Chen W,Liu J,Shi S

    更新日期:2011-07-01 00:00:00

  • Simulation study of a chaotic cavity transducer based virtual phased array used for focusing in the bulk of a solid material.

    abstract::In acoustic and ultrasonic non-destructive testing techniques, it is sometimes beneficial to concentrate sound energy at a chosen location in space and at a specific instance in time, for example to improve the signal-to-noise ratio or activate the nonlinearity of damage features. Time Reversal (TR) techniques, taking...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.01.010

    authors: Delrue S,Van Den Abeele K,Bou Matar O

    更新日期:2016-04-01 00:00:00

  • Ultrasonic characterization of Cu-Al-Ni single crystals lattice stability in the vicinity of the phase transition.

    abstract::Measurements of elastic constants of the austenite phase when approaching the phase transformation either upon cooling or stressing is of the crucial interest for the shape memory alloy field. Acoustic properties (wave velocity and also attenuation changes) of the Cu-Al-Ni single crystal were investigated in situ duri...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.029

    authors: Landa M,Novák V,Sedlák P,Sittner P

    更新日期:2004-04-01 00:00:00

  • Directivity pattern of neurosurgical endoscopic ultrasonic probes.

    abstract::The objective of this paper is to present recent investigations in characteristics of the sound field generated by neurosurgical endoscopic ultrasonic probes (NEUPs) for minimally invasive surgery. The importance of this information has been investigated and discussed taking into account following facts: 1. According ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00217-2

    authors: Stimac A,Ivancević B,Jambrosić K

    更新日期:2002-05-01 00:00:00

  • Determination of the material properties of microstructures by laser based ultrasound.

    abstract::In most applications of MEMS the mechanical properties of the used materials are key parameters for the perfect working of the microsystems. Measuring bulk acoustic waves excited in MEMS structures with ultra-short laser pulses is a powerful method for the accurate and non-destructive evaluation as well as for the cha...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.049

    authors: Profunser DM,Vollmann J,Dual J

    更新日期:2004-04-01 00:00:00

  • Sparse signal representation and its applications in ultrasonic NDE.

    abstract::Many sparse signal representation (SSR) algorithms have been developed in the past decade. The advantages of SSR such as compact representations and super resolution lead to the state of the art performance of SSR for processing ultrasonic non-destructive evaluation (NDE) signals. Choosing a suitable SSR algorithm and...

    journal_title:Ultrasonics

    pub_type: 杂志文章,评审

    doi:10.1016/j.ultras.2011.10.001

    authors: Zhang GM,Zhang CZ,Harvey DM

    更新日期:2012-03-01 00:00:00

  • Laser-generated surface acoustic waves in a ring-shaped waveguide resonator.

    abstract::Surface acoustic wave (SAW) waveguide resonator is formed by a ring-shaped strip of copper 10 microm wide and approximately 130 microm in diameter embedded into a 0.8 microm thick layer of silica on a silicon wafer. SAWs are excited at one side of the copper ring by a short laser pulse focused into a spatially periodi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.04.007

    authors: Maznev AA

    更新日期:2009-01-01 00:00:00

  • In vitro chronic hepatic disease characterization with a multiparametric ultrasonic approach.

    abstract::Although, high resolution, real-time ultrasonic (US) imaging is routinely available, image interpretation is based on grey-level and texture and quantitative evaluation is limited. Other potentially useful diagnostic information from US echoes may include modifications in tissue acoustic parameters (speed, attenuation...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.09.002

    authors: Meziri M,Pereira WC,Abdelwahab A,Degott C,Laugier P

    更新日期:2005-03-01 00:00:00

  • Generation of transversal envelope soliton in polymeric and wooden rods.

    abstract::This paper is concerned with the probing of the transversal envelope solitons propagation in circular waveguides when a set of requirements (non-linearity and dispersion) are fulfilled in the waveguide and balanced. The basic idea is to analyze the shape of an acoustic pulse after it has traveled one or few trips thro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.01.016

    authors: de Billy M,Hladky-Hennion AC

    更新日期:2014-07-01 00:00:00

  • Generation of microbubbles from hollow cylindrical ultrasonic horn.

    abstract::In this study, we found that microbubbles with diameters of less than 100μm can be easily generated by using a hollow cylindrical ultrasonic horn. Consecutive images of bubbles obtained by using high-speed and high-resolution cameras reveal that a capillary wave is formed on the gas-liquid interface under weak ultraso...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.010

    authors: Makuta T,Suzuki R,Nakao T

    更新日期:2013-01-01 00:00:00

  • Design of ultrasonic wedge transducer.

    abstract::Cones and wedges inserted between an ultrasonic transducer and the specimen provide the transducer (circular or rectangular shape) with enhanced capability for point or line contact with the specimen. Such an arrangement is useful in that the transducer can be used for transmitting to and receiving from a point (or li...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.10.002

    authors: Rus G,Wooh SC,Gallego R

    更新日期:2005-03-01 00:00:00

  • Annular phased array transducer for preclinical testing of anti-cancer drug efficacy on small animals.

    abstract::A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.12.008

    authors: Kujawska T,Secomski W,Byra M,Postema M,Nowicki A

    更新日期:2017-04-01 00:00:00

  • Automated segmentation of transcranial sonographic images in the diagnostics of Parkinson's disease.

    abstract::Images captured during routine clinical transcranial sonography (TCS) examination are of a low resolution, so can be confusing for diagnostic evaluations. Manual segmentation of brain structures (areas of the midbrain and substantia nigra (SN)) that are of special interest cause inter-observer and intra-observer varia...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.04.005

    authors: Sakalauskas A,Lukoševičius A,Laučkaitė K,Jegelevičius D,Rutkauskas S

    更新日期:2013-01-01 00:00:00

  • Analysis of speckle in ultrasound images using fractional order statistics and the homodyned k-distribution.

    abstract::It is necessary to identify speckled regions in ultrasound images to control adaptive speckle suppression algorithms, for tissue characterisation, and to estimate the elevational separation of B-scans by speckle decorrelation. Previous authors have proposed classification techniques based on second order powers of the...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00104-x

    authors: Prager RW,Gee AH,Treece GM,Berman LH

    更新日期:2002-05-01 00:00:00

  • The analysis of the effect of homogeneous mechanical stress on the acoustic wave propagation in the "La3Ga5SiO14/fused silica" piezoelectric layered structure.

    abstract::The results of computer simulation taking into account the linear and nonlinear material constants have been presented. Study of the influence of external uniaxial mechanical stress on the dispersive characteristics of elastic waves in piezoelectric structures as "La3Ga5SiO14/fused silica" has been executed. The compa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.07.007

    authors: Burkov SI,Zolotova OP,Sorokin BP,Turchin PP

    更新日期:2015-01-01 00:00:00

  • Acoustically assisted removal of nitrogen oxide from high temperature flue gas.

    abstract::The present study focuses on a possibility for improving NO removal efficiency from flue gas by application of powerful sound waves. The sound waves (frequency 6.9-17.2kHz, intensity 144-160dB) are propagated from Hartmann sound generators to a preheated graphite disk inside a vertical reaction tube (height 1.8m, I.D....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.06.010

    authors: Komarov SV,Nemeth S,Hirasawa M

    更新日期:2005-02-01 00:00:00

  • Non-contact measurement of the thickness of a surface film using a superimposed ultrasonic standing wave.

    abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106291

    authors: Kanja J,Mills R,Li X,Brunskill H,Hunter AK,Dwyer-Joyce RS

    更新日期:2021-02-01 00:00:00