Abstract:
:A cylindrical standing wave ultrasonic motor using bending vibration transducer was proposed in this paper. The proposed stator contains a cylinder and a bending vibration transducer. The two combining sites between the cylinder and the transducer locate at the adjacent wave loops of bending vibration of the transducer and have a distance that equal to the half wave length of bending standing wave excited in the cylinder. Thus, the bending mode of the cylinder can be excited by the bending vibration of the transducer. Two circular cone type rotors are pressed in contact to the end rims of the teeth, and the preload between the rotors and stator is accomplished by a spring and nut system. The working principle of the proposed motor was analyzed. The motion trajectories of teeth were deduced. The stator was designed and analyzed with FEM. A prototype motor was fabricated and measured. Typical output of the prototype is no-load speed of 165rpm and maximum torque of 0.45Nm at an exciting voltage of 200V(rms).
journal_name
Ultrasonicsjournal_title
Ultrasonicsauthors
Liu Y,Chen W,Liu J,Shi Sdoi
10.1016/j.ultras.2010.12.007subject
Has Abstractpub_date
2011-07-01 00:00:00pages
527-31issue
5eissn
0041-624Xissn
1874-9968pii
S0041-624X(10)00193-9journal_volume
51pub_type
杂志文章相关文献
ULTRASONICS文献大全abstract::This paper proposes a new pair of sequences whose cross-correlation values are zero except for the peak value and presents a new modulation method for an ultrasonic Doppler flowmeter with high sensitivity utilizing these sequences. In this method, transmitted and received waves are modulated and demodulated, respectiv...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(79)90023-4
更新日期:1979-11-01 00:00:00
abstract::The digital ultrasonic fixed path interferometer designed for testing small amounts of sample was used for the investigation of whole blood coagulation, retraction and clot melting processes. The ultrasound velocity and absorption are determined from the characteristics of an acoustic resonator consisting of an emitte...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(78)90007-0
更新日期:1978-01-01 00:00:00
abstract::Classically, rotary motors with gears and spindle mechanisms are used to achieve translatory motion. In means of miniaturization and weight reduction piezoelectric linear motors are of interest. Several ultrasonic linear motors found in literature base on the use of two different vibration modes. Most often flexural a...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.056
更新日期:2006-12-22 00:00:00
abstract::Angle beam wedge transducers are widely used in nonlinear Rayleigh wave experiments as they can generate Rayleigh wave easily and produce high intensity nonlinear waves for detection. When such a transducer is used, the spurious harmonics (source nonlinearity) and wave diffraction may occur and will affect the measure...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2018.05.004
更新日期:2018-09-01 00:00:00
abstract:OBJECTIVES:This paper aims to apply median filters for reducing interpolation error and improving the quality of 3D images in a freehand 3D ultrasound (US) system. BACKGROUND AND MOTIVATION:Freehand 3D US imaging has been playing an important role in obtaining the entire 3D impression of tissues and organs. Reconstruc...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2007.11.005
更新日期:2008-07-01 00:00:00
abstract::This paper provides a derivation of the Christoffel eigenvalue equation for acoustic wave propagation in an acoustically damped piezoelectric medium. The damping tensor is shown to couple into both the stress and displacement constitutive equations. Application of the quasi-static approximation leads to an additional ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.09.005
更新日期:2006-12-01 00:00:00
abstract::This paper deals with the influence of acousto-optic interactions on the displacement measurements performed over transducer array and their effects on the predicted diffraction field. Changes on the temporal/spatial responses and the plane wave decomposition of the displacement are discussed. Modifications made on th...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2003.12.035
更新日期:2004-04-01 00:00:00
abstract::Transducer is the necessary and most important part in the maxonics. New applications demand for new transducer, and the renovation of the transducer will open a new field for the application of the maxonics. The important method to develop new transducer is to find and develop new material. The rare earth giant magne...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.128
更新日期:2006-12-22 00:00:00
abstract::The matrix method for analyzing flexural vibration system is outlined. The displacement, stress and velocity gain of ultrasonic flexural vibration systems are investigated by transfer matrix method. A design method is given for flexural transducer and vibration system. ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(00)00034-2
更新日期:2000-11-01 00:00:00
abstract::A method for measuring the mechanical quality factor (Q factor) of materials in large-amplitude flexural vibrations was devised on the basis of the original definition of the Q factor. The Q factor, the ratio of the reactive energy to the dissipated energy, was calculated from the vibration velocity distribution. The ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.03.012
更新日期:2016-07-01 00:00:00
abstract::One of the important issues in the field of ultrasound medical imaging using contrast agents is the development of techniques able to separate the response of the contrast media from that of the biological tissues. In the literature, one can find various solutions involving the use of multiple transmitted signals and ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.05.008
更新日期:2009-01-01 00:00:00
abstract::It has been suggested that viscous losses, caused by the motion of myofibrils relative to their environmental fluid, could be the major cause of ultrasound attenuation in muscle. This Paper presents theoretical and experimental estimates of the viscous component of attenuation in suspensions of myofibrils. Experimenta...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(88)90046-7
更新日期:1988-01-01 00:00:00
abstract::This paper describes an optimization method of the top electrode size for a thin film matrix ultrasonic transducer (M-UT) in the frequency range above 200 MHz. The goal of this work is to design an optimal top electrode size for an M-UT providing the maximal output peak-peak voltage (V(PP)) and the maximal signal-to-n...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.10.018
更新日期:2013-03-01 00:00:00
abstract::In most applications of MEMS the mechanical properties of the used materials are key parameters for the perfect working of the microsystems. Measuring bulk acoustic waves excited in MEMS structures with ultra-short laser pulses is a powerful method for the accurate and non-destructive evaluation as well as for the cha...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.049
更新日期:2004-04-01 00:00:00
abstract::A split spectrum processing technique using a novel moving bandwidth minimization (MBM) method was developed to detect multiple specular targets having different spectral characteristics. Mathematical morphology (MM) algorithms were also implemented in order to compare the results. An experimental approach to optimal ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(99)00024-4
更新日期:1999-09-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Acoustic scattering properties of ultrasound contrast agents are useful in extending existing or developing new techniques for biomedical imaging applications. A useful first step in this direction is to investigate the acoustic scattering of a new class of acoustic beams, known as helicoidal h...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2009.09.003
更新日期:2010-03-01 00:00:00
abstract::Several experimental studies have demonstrated that ultrasound (US) can accelerate enzymatic fibrinolysis and this effect is further enhanced in the presence of ultrasound contrast agents (UCA). Although UCA have been shown to be safe when administered to ischemic stroke patients, safety information of these agents in...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2007.10.003
更新日期:2008-04-01 00:00:00
abstract:BACKGROUND:Generalized coherence factor (GCF) can be adaptively estimated from channel data to suppress sidelobe artifacts. Conventionally, Fast Fourier Transform (FFT) is utilized to calculate the full channel spectrum and suffers from high computation load. In this work, autocorrelation (AR)-based algorithm is utiliz...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.07.015
更新日期:2016-12-01 00:00:00
abstract::Knowing the low-frequency response of hydrophones, down to 100 kHz at least, is important for accurate biomedical ultrasound measurements. However, current international standards do not extend below 500 kHz. Furthermore, commercial hydrophone sources typically do not supply sensitivity data below 1-2 MHz. Therefore, ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2003.12.008
更新日期:2004-04-01 00:00:00
abstract::Experimental and theoretical studies on degradation of composite-epoxy adhesive joints were carried out on samples having different interfacial and cohesive properties. Oblique incidence ultrasonic inspection of bonded joints revealed that degradation in the adhesive can be measured by significant variation in reflect...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.01.014
更新日期:2013-08-01 00:00:00
abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106291
更新日期:2021-02-01 00:00:00
abstract::A localization approach of welded joint damage is proposed based on acoustic emission (AE) beamforming. In this method, a uniform line array is introduced to detect the AE signal of welded joints in specified area. In order to investigate the influence of fillet and crimping commonly existing in a welded plate structu...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.11.002
更新日期:2017-02-01 00:00:00
abstract::This paper focuses on transmission characteristics of fundamental symmetric Lamb mode (So) at the junction of a main waveguide and sub-waveguides in composite laminates. Numerical simulations on transmission of So from the main to sub-waveguide revealed that transmission factors of the modes depend on stacking sequenc...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.08.003
更新日期:2016-01-01 00:00:00
abstract::Ultrasonic vibration cutting is an efficient cutting process for mechanical micro-machining. This process can generate intricate surface textures with different geometric characteristics. Micro-grooves/micro-channels are among the most frequently encountered micro-structures and, as such, are the focus of this paper. ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.12.016
更新日期:2016-04-01 00:00:00
abstract::In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.080
更新日期:2004-04-01 00:00:00
abstract::In this paper, the resonance frequency equation and expression of displacement amplitude magnifications of a full-wave barber ultrasonic horn are obtained. By discussing the relationships between the displacement amplitude magnifications and the geometrical dimensions, the optimized design of the horn for the largest ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.12.006
更新日期:2012-07-01 00:00:00
abstract::The remote inspection for defects in large metallic elements such as pipes, tubes and plates is a field where guided waves are being applied with success. There are a number of situations where a surface coating is added for corrosion protection or insulation purposes. Since the coating materials are usually viscoelas...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.072
更新日期:2004-04-01 00:00:00
abstract::The wave propagation of an infinite functionally graded plate in thermal environments is studied using the higher-order shear deformation plate theory. The thermal effects and temperature-dependent material properties are both taken into account. The temperature field considered is assumed to be a uniform distribution...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.05.009
更新日期:2011-12-01 00:00:00
abstract::Surface and quasi-longitudinal acoustic wave properties have been investigated in potassium titanyl arsenate (KTiOAsO₄, KTA) single crystals for the first time. Surface acoustic wave (SAW) velocity, electromechanical coupling coefficient and power flow angle characteristics have been obtained in rotated Y-cut of KTA c...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.09.019
更新日期:2014-02-01 00:00:00
abstract::Fundamental understanding of ultrasound interaction with material discontinuities having closed interfaces has many engineering applications such as nondestructive evaluation of defects like kissing bonds and cracks in critical structural and mechanical components. In this paper, to analyze the acoustic field nonlinea...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.12.007
更新日期:2018-03-01 00:00:00