Abstract:
:Fundamental understanding of ultrasound interaction with material discontinuities having closed interfaces has many engineering applications such as nondestructive evaluation of defects like kissing bonds and cracks in critical structural and mechanical components. In this paper, to analyze the acoustic field nonlinearities due to defects with closed interfaces, the use of a common technique in nonlinear physics, based on a phase-space topography construction of ultrasound waveform, is proposed. The central idea is to complement the "time" and "frequency" domain analyses with the "phase-space" domain analysis of nonlinear ultrasound waveforms. A nonlinear time series method known as pseudo phase-space topography construction is used to construct equivalent phase-space portrait of measured ultrasound waveforms. Several nonlinear models are considered to numerically simulate nonlinear ultrasound waveforms. The phase-space response of the simulated waveforms is shown to provide different topographic information, while the frequency domain shows similar spectral behavior. Thus, model classification can be substantially enhanced in the phase-space domain. Experimental results on high strength aluminum samples show that the phase-space transformation provides a unique detection and classification capabilities. The Poincaré map of the phase-space domain is also used to better understand the nonlinear behavior of ultrasound waveforms. It is shown that the analysis of ultrasound nonlinearities is more convenient and informative in the phase-space domain than in the frequency domain.
journal_name
Ultrasonicsjournal_title
Ultrasonicsauthors
Dehghan-Niri E,Al-Beer Hdoi
10.1016/j.ultras.2017.12.007subject
Has Abstractpub_date
2018-03-01 00:00:00pages
446-458eissn
0041-624Xissn
1874-9968pii
S0041-624X(17)30804-1journal_volume
84pub_type
杂志文章相关文献
ULTRASONICS文献大全abstract::The threshold filter is a frequently used technique in ultrasound B-scan to reject the small echoes contributed from backscattering that blur the tissue interface and reduce the image contrast. Note that using the threshold based on one value would simultaneously destroy local waveform features of the reflection echoe...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.10.007
更新日期:2009-05-01 00:00:00
abstract::Several experimental studies have demonstrated that ultrasound (US) can accelerate enzymatic fibrinolysis and this effect is further enhanced in the presence of ultrasound contrast agents (UCA). Although UCA have been shown to be safe when administered to ischemic stroke patients, safety information of these agents in...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2007.10.003
更新日期:2008-04-01 00:00:00
abstract::As known, anomalous resisto-acoustic effect is a fundamental property for weakly inhomogeneous piezoactive waves (Bleustein-Gulyaev, Love, and some leaky waves). It consists in that the velocity of aforementioned waves first increases, achieves its maximum, and only then decreases with increasing conductance of a laye...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.01.007
更新日期:2015-05-01 00:00:00
abstract::The properties of optical to acoustic transduction of semiconductor superlattices have been explored for several years in the sub terahertz frequency range. Using femtosecond laser pulses focused on these structures, acoustic modes are excited with a frequency related to the periodicity of the structure stacking. We h...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.07.009
更新日期:2015-02-01 00:00:00
abstract::The purpose of this research was to develop, implement and verify a measurement technique enabling rapid and dependable characterization of ultrasound hydrophone probes beyond 20 MHz. The technique employs focused acoustic sources to optimize signal-to-noise ratio and spatial averaging correction model to account for ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00166-x
更新日期:2002-05-01 00:00:00
abstract::In this study, we present a model study of guided wave dispersion and resonance behavior of an array of piezoelectric plates with arbitrary cross-sections. The objective of this work is to analyze the influence of the geometry of an element of a 1D-array ultrasound transducer on generating multi-resonance frequency so...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2009.08.006
更新日期:2010-03-01 00:00:00
abstract::A surface ultrasonic wave approach was presented for measuring surface stress of brush electro-plating nickel coating specimen, and the influence of coating thickness on surface stress measurement was discussed. In this research, two Rayleigh wave transducers with 5MHz frequency were employed to collect Rayleigh wave ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.02.003
更新日期:2012-09-01 00:00:00
abstract::B-Scan images have been used as a means of detecting the onset of cavitation in tissues. New echoes appearing during simultaneous sonication with therapeutic ultrasound have often been attributed to bubble formation. In this study temperature rises up to 15 degrees C W-1 cm2 in guinea pig leg (post-mortem) were found,...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(91)90028-7
更新日期:1991-07-01 00:00:00
abstract::In this work, we investigate the efficiency of graphene production from graphite by ultrasonic-induced exfoliation under different operational conditions. An ultrasonic bath and an ultrasonic horn tip were used, to show how the graphene production efficiency depends on the acoustic intensity and cavitation mechanism u...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.105989
更新日期:2020-01-01 00:00:00
abstract::We develop a new ultrasonic imaging framework for non-destructive testing of an immersed specimen featuring an irregular top surface and demonstrate its capability of accurately depicting the lower surfaces of multiple damages hidden in the specimen. Central to the framework is a multistep angular spectrum approach (A...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106233
更新日期:2020-12-01 00:00:00
abstract::Ultrasonic cutting is widely used in food processing applications to produce a clean and accurate cut. However, it is yet to be adopted as an instrument of choice in orthopaedic applications, mainly due to the high temperatures that can be generated at the cut site and the consequent requirement to use additional cool...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.06.046
更新日期:2006-12-22 00:00:00
abstract::This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined b...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.027
更新日期:2006-12-22 00:00:00
abstract::The results of computer simulation taking into account the linear and nonlinear material constants have been presented. Study of the influence of external uniaxial mechanical stress on the dispersive characteristics of elastic waves in piezoelectric structures as "La3Ga5SiO14/fused silica" has been executed. The compa...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.07.007
更新日期:2015-01-01 00:00:00
abstract::In order to investigate non-destructively the bonding between rough plates, the problem of Lamb waves propagating on a rough plate is addressed in this paper. Numerical analysis is performed on periodical gratings made of identical triangular grooves. If the surface profile is made up of grooves with one periodicity, ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.052
更新日期:2006-12-22 00:00:00
abstract::This study investigated the effect of LIPUS on fracture healing when fractures were exposed to ultrasound at three axial distances: z=0 mm, 60 mm, and 130 mm. We applied LIPUS to rat fracture at these three axial distances mimicking the exposure condition of human fractures at different depths under the soft tissue. M...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.10.013
更新日期:2014-03-01 00:00:00
abstract::The remote inspection for defects in large metallic elements such as pipes, tubes and plates is a field where guided waves are being applied with success. There are a number of situations where a surface coating is added for corrosion protection or insulation purposes. Since the coating materials are usually viscoelas...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.072
更新日期:2004-04-01 00:00:00
abstract::The purpose of this study is to evaluate whether a 5-repetition liver stiffness (LS) measurement as the standard protocol of shear wave elastography (SWE) is comparable to a conventional 10-repetition measurement protocol and to identify factors that influence the reliability of the 5-repetition protocol. A total of 3...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.08.005
更新日期:2016-12-01 00:00:00
abstract::We experimentally demonstrate a very large ultrasonic band gap in a one-dimensional phononic crystal. The structure consists of periodic tungsten pillars fixed to a tailored silicon strip with a layer of epoxy. Combining local resonances and Bragg scattering, the gap ranges from 450kHz to 1250kHz, which corresponds to...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.03.003
更新日期:2017-07-01 00:00:00
abstract::Focused ultrasound holds promise in a large number of therapeutic applications. It has long been known that high intensity focused ultrasound can kill tissue through coagulative necrosis. However, it is only in recent years that practical clinical applications are becoming possible, with the development of high power ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.04.003
更新日期:2004-08-01 00:00:00
abstract::In this paper, te edge mode variation is studied with three different methods: the reciprocal work method, already used by Torvik [J. Acoust. Soc. Am. 41 (1967) 346] to model this phenomenon, the S-parameter method and a finite element model that are applied for the first time to the study of the edge resonance. Moreo...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00391-8
更新日期:2003-01-01 00:00:00
abstract::This paper introduces a new beamformer, which combines the eigenspace based minimum variance (ESBMV) beamformer with a subarray coherence based postfilter (SCBP), for improving the quality of ultrasound plane-wave imaging. The ESBMV beamformer has been validated in improving the imaging contrast, but the difficulty in...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.10.026
更新日期:2016-02-01 00:00:00
abstract::Based on the original combination of picosecond acoustics and diamond anvils cell, recent improvements to accurately measure hypersonic sound velocities of liquids and solids under extreme conditions are described. To illustrate the capability of this technique, results are given on the pressure and temperature depend...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.04.011
更新日期:2015-02-01 00:00:00
abstract::This paper deals with the influence of acousto-optic interactions on the displacement measurements performed over transducer array and their effects on the predicted diffraction field. Changes on the temporal/spatial responses and the plane wave decomposition of the displacement are discussed. Modifications made on th...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2003.12.035
更新日期:2004-04-01 00:00:00
abstract::For medical high frequency acoustic imaging purposes the reduction in size of a single transducer element for one-dimensional and even more for two-dimensional arrays is more and more limited by fabrication and cabling technology. In the fields of industrial distance measurement and simple object recognition low cost ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(99)00085-2
更新日期:2000-03-01 00:00:00
abstract::It has been established that structural changes in a ferrofluid (formation of clusters) upon the effect of an external magnetic field can be effectively studied by ultrasound spectroscopy. In particular, the resonance absorption of ultrasonic waves enables detection and determination of the size of spherical clusters....
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00117-8
更新日期:2002-05-01 00:00:00
abstract::A numerical study is carried out of the surface acoustic wave generation by a bulk acoustic wave in a half-infinite anisotropic half-space without piezoeffect. The efficient conversion of bulk waves into surface waves occurs due to a grating area created on the surface of the substrate. Our simulations are fully based...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.01.007
更新日期:2013-07-01 00:00:00
abstract::This paper is concerned with the probing of the transversal envelope solitons propagation in circular waveguides when a set of requirements (non-linearity and dispersion) are fulfilled in the waveguide and balanced. The basic idea is to analyze the shape of an acoustic pulse after it has traveled one or few trips thro...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.01.016
更新日期:2014-07-01 00:00:00
abstract::The numerical studies conducted in this paper are based on our previous research (Chen et al., 2017); through use of the spectral element method, parametric sensitivity studies of Nonlinear Coda Wave Interferometry (NCWI) are established here and divided into two parts. In the first part, CWI observables are found to ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.105968
更新日期:2019-11-01 00:00:00
abstract::In cancellous bone, longitudinal waves often separate into fast and slow waves depending on the alignment of bone trabeculae in the propagation path. This interesting phenomenon becomes an effective tool for the diagnosis of osteoporosis because wave propagation behavior depends on the bone structure. Since the fast w...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.04.011
更新日期:2008-11-01 00:00:00
abstract::This research paper is the experimental study to investigate the effect of ultrasound sensitivity in the pure methane gas space as the pressure and sensor distance increases. We offer the solution to overcome the low sensitivity characteristics of ultrasonic sensors in the methane gas space. This proposal shows the ph...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.105970
更新日期:2019-11-01 00:00:00