Influence of acousto-optic interactions on the determination of the diffracted field by an array obtained from displacement measurements.

Abstract:

:This paper deals with the influence of acousto-optic interactions on the displacement measurements performed over transducer array and their effects on the predicted diffraction field. Changes on the temporal/spatial responses and the plane wave decomposition of the displacement are discussed. Modifications made on the directivity pattern are shown. A theoretical analysis of acousto-optic phenomenon, based on the plane wave decomposition of radiated field by the array is developed. Theoretical and experimental results are compared, showing first that waves with phase velocity near the one of the fluid are greatly amplified. Second, the interaction of laser beam with edge wave produced by the vertical size of elements induces a parasitic temporal pulse on the x-t diagram and so an interference pattern in the omega-k diagram. Corrections are proposed to eliminate errors induced by acousto-optic interactions and validated by comparing predicted diffraction field with measurements.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Certon D,Ferin G,Bou Matar O,Guyonvarch J,Remenieras JP,Patat F

doi

10.1016/j.ultras.2003.12.035

subject

Has Abstract

pub_date

2004-04-01 00:00:00

pages

465-71

issue

1-9

eissn

0041-624X

issn

1874-9968

pii

S0041624X03002580

journal_volume

42

pub_type

杂志文章
  • An adaptive threshold filter for ultrasound signal rejection.

    abstract::The threshold filter is a frequently used technique in ultrasound B-scan to reject the small echoes contributed from backscattering that blur the tissue interface and reduce the image contrast. Note that using the threshold based on one value would simultaneously destroy local waveform features of the reflection echoe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.007

    authors: Tsui PH,Chang CC,Chang CC,Huang NE,Ho MC

    更新日期:2009-05-01 00:00:00

  • Microbiological properties of poultry breast meat treated with high-intensity ultrasound.

    abstract::Lactic acid, psychrophilic, and mesophilic bacteria, Escherichia coli, Salmonella spp. and Staphylococcus aureus were enumerated on chicken breasts after treatment with different high intensity ultrasound (frequency 40 kHz, intensity 9.6 W/cm-2) application times (0, 30, and 50 min) and packaging atmospheres (aerobic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.01.001

    authors: Piñon MI,Alarcon-Rojo AD,Renteria AL,Carrillo-Lopez LM

    更新日期:2020-03-01 00:00:00

  • Hypersonic velocity measurement using Brillouin scattering technique. Application to water under high pressure and temperature.

    abstract::This paper presents recent improvement on sound velocity measurements under extreme conditions, illustrated by the hypersonic sound velocity measurements of water up to 723 K and 9 GPa using Brillouin scattering technique. Because water at high pressure and high temperature is chemically very aggressive, these experim...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.150

    authors: Decremps F,Datchi F,Polian A

    更新日期:2006-12-22 00:00:00

  • The computations of reflection coefficients of multilayer structure based on the reformulation of Thomson-Haskell method.

    abstract::A reformulation of the Thomson-Haskell method is presented for calculating the reflection coefficients of multilayer structure immersing in the coupling fluid. Instead of directly multiplying the layer propagator matrix, the new method splits the layer propagator matrix and excursively determines the interface stiffne...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.08.004

    authors: Chen J,Bai X,Yang K,Ju BF

    更新日期:2012-12-01 00:00:00

  • Surface and quasi-longitudinal acoustic waves in KTiOAsO₄ single crystals.

    abstract::Surface and quasi-longitudinal acoustic wave properties have been investigated in potassium titanyl arsenate (KTiOAsO₄, KTA) single crystals for the first time. Surface acoustic wave (SAW) velocity, electromechanical coupling coefficient and power flow angle characteristics have been obtained in rotated Y-cut of KTA c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.019

    authors: Taziev RM

    更新日期:2014-02-01 00:00:00

  • A novel method for Estimating Time of Flight of ultrasonic echoes through short-time Fourier transforms.

    abstract::The accurate estimation of time of flight (TOF) of an ultrasonic signal is essential in ultrasonic non-destructive testing (NDT). A novel method for TOF estimation based on the short-time Fourier transform (STFT) is proposed in this paper. Firstly, the time and frequency components of ultrasonic echoes are represented...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106104

    authors: Lu Z,Ma F,Yang C,Chang M

    更新日期:2020-04-01 00:00:00

  • Effects of ultrasonic energy on dyeing of polyamide (microfibre)/Lycra blends.

    abstract::Although ultrasonic energy is widely used cleaning and degreasing of parts and assemblies in automotive and other industries, the use of ultrasonic energy in an industrial scale for textile washing is very new. This is due to the complexity of controlling the combination of chemical and mechanical effects, whereas wit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.02.005

    authors: Merdan N,Akalin M,Kocak D,Usta I

    更新日期:2004-04-01 00:00:00

  • Methods for reducing cutting temperature in ultrasonic cutting of bone.

    abstract::Ultrasonic cutting is widely used in food processing applications to produce a clean and accurate cut. However, it is yet to be adopted as an instrument of choice in orthopaedic applications, mainly due to the high temperatures that can be generated at the cut site and the consequent requirement to use additional cool...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.046

    authors: Cardoni A,MacBeath A,Lucas M

    更新日期:2006-12-22 00:00:00

  • Numerical simulation of electromagnetic acoustic transducers using distributed point source method.

    abstract::In spite of many advances in analytical and numerical modeling techniques for solving different engineering problems, an efficient solution technique for wave propagation modeling of an electromagnetic acoustic transducer (EMAT) system is still missing. Distributed point source method (DPSM) is a newly developed semi-...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.12.003

    authors: Eskandarzade M,Kundu T,Liebeaux N,Placko D,Mobadersani F

    更新日期:2010-05-01 00:00:00

  • A fast technique for hyper-echoic region separation from brain ultrasound images using patch based thresholding and cubic B-spline based contour smoothing.

    abstract::Ultrasound image guided brain surgery (UGBS) requires an automatic and fast image segmentation method. The level-set and active contour based algorithms have been found to be useful for obtaining topology-independent boundaries between different image regions. But slow convergence limits their use in online US image s...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106304

    authors: Chel H,Bora PK,Ramchiary KK

    更新日期:2021-03-01 00:00:00

  • Inversion of synthetic and experimental acoustical scattering data for the comparison of two reconstruction methods employing the Born approximation.

    abstract::This work is concerned with the reconstruction, from measured (synthetic or real) data, of a 2D penetrable fluid-like object of arbitrary cross-section embedded in a fluid of infinite extent and insonified by a plane acoustic wave. Green's theorem is used to provide a domain integral representation of the scattered fi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00054-8

    authors: Guillermin R,Lasaygues P,Sessarego JP,Wirgin A

    更新日期:2001-03-01 00:00:00

  • Location of acoustic emission sources generated by air flow

    abstract::The location of continuous acoustic emission sources is a difficult problem of non-destructive testing. This article describes one-dimensional location of continuous acoustic emission sources by using an intelligent locator. The intelligent locator solves a location problem based on learning from examples. To verify w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00079-7

    authors: Kosel T,Grabec I I,Muzic P

    更新日期:2000-03-01 00:00:00

  • Nonlinear coda wave interferometry for the global evaluation of damage levels in complex solids.

    abstract::A nonlinear acoustic method to assess the damage level of a complex medium is discussed herein. Thanks to the highly nonlinear elastic signatures of cracks or, more generally, internal solid contacts, this method is able to distinguish between contributions from linear wave scattering by a heterogeneity and contributi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.09.015

    authors: Zhang Y,Tournat V,Abraham O,Durand O,Letourneur S,Le Duff A,Lascoup B

    更新日期:2017-01-01 00:00:00

  • Experimental and numerical study of evanescent waves in the mini stopband of a 1D phononic crystal.

    abstract::This paper deals with the analysis of the guided evanescent waves in stopbands of a 1D phononic crystal (PC). A new numerical implementation is shown in order to get the complex values of the wavenumbers in a frequency range where a gap occurs. The considered phononic system is an aluminum plate with a one-dimensional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.09.009

    authors: Bavencoffe M,Morvan B,Hladky-Hennion AC,Izbicki JL

    更新日期:2013-02-01 00:00:00

  • An improved Richardson-Lucy iterative algorithm for C-scan image restoration and inclusion size measurement.

    abstract::The accuracy of measuring inclusion size in direct C-scan image of immersion ultrasonic testing is restricted by the lateral resolution of the focused transducer, even if a high frequency is used, and the blurred edge due to scattering of sound waves at inclusions. In this work, an improved image restoration method th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.07.021

    authors: Chen D,Xiao H,Xu J

    更新日期:2019-01-01 00:00:00

  • Ultrasonic strain imaging and reconstructive elastography for biological tissue.

    abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.007

    authors: Khaled W,Reichling S,Bruhns OT,Ermert H

    更新日期:2006-12-22 00:00:00

  • Simulation of ultrasonic and EMAT arrays using FEM and FDTD.

    abstract::This paper presents a method which combines electromagnetic simulation and ultrasonic simulation to build EMAT array models. For a specific sensor configuration, Lorentz forces are calculated using the finite element method (FEM), which then can feed through to ultrasonic simulations. The propagation of ultrasound wav...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.10.020

    authors: Xie Y,Yin W,Liu Z,Peyton A

    更新日期:2016-03-01 00:00:00

  • Modeling electrical response of polymer-coated SAW resonators by equivalent circuit representation.

    abstract::The paper presents an equivalent circuit model of the polymer coated surface acoustic wave (SAW) resonators by combining coupling-of-mode (COM) description of SAW resonators and perturbation calculation of SAW propagation under polymer loading. An expression for the motional load produced by polymer coating is deduced...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.12.006

    authors: Kshetrimayum R,Yadava RD,Tandon RP

    更新日期:2011-07-01 00:00:00

  • Porous material characterization--ultrasonic method for estimation of tortuosity and characteristic length using a barometric chamber.

    abstract::An ultrasonic method of acoustic parameter evaluation for porous materials saturated by air (or any other gas) is discussed. The method is based on the evolution of speed of sound and the attenuation inside the material when the static pressure of the gas saturating the material is changed. Asymptotic development of t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00062-7

    authors: Moussatov A,Ayrault C,Castagnède B

    更新日期:2001-04-01 00:00:00

  • Development of an ultra-portable echo device connected to USB port.

    abstract::In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.11.009

    authors: Saijo Y,Nitta S,Kobayashi K,Arai H,Nemoto Y

    更新日期:2004-04-01 00:00:00

  • High-intensity ultrasound irradiation promotes the release of extracellular vesicles from C2C12 myotubes.

    abstract::Skeletal muscle is an important secretory organ in mammals, producing myriad chemical mediators ("myokines") with distinct biological action in different tissues, including anti-inflammatory activity. Extracellular vesicles (EVs) have recently been identified as a mode of myokine transport from muscle, facilitating su...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106243

    authors: Maeshige N,Langston PK,Yuan ZM,Kondo H,Fujino H

    更新日期:2021-02-01 00:00:00

  • A prosthetic aid for a developing blind child.

    abstract::An experimental ultrasonic sonar for use as a sensory aid with blind children is described. Novel signal processing techniques make the aid relatively simple to construct, yet allow many of its parameters to be changed in the field. In particular, the aid has two features, a variable range code and an automatic level...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(79)90010-6

    authors: Boys JT,Strelow ER,Clark GR

    更新日期:1979-01-01 00:00:00

  • A new modulation method with range resolution for ultrasonic Doppler flow sensing.

    abstract::This paper proposes a new pair of sequences whose cross-correlation values are zero except for the peak value and presents a new modulation method for an ultrasonic Doppler flowmeter with high sensitivity utilizing these sequences. In this method, transmitted and received waves are modulated and demodulated, respectiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(79)90023-4

    authors: Shiozaki A,Senda S,Kitabatake A,Inoue M,Matsuo H

    更新日期:1979-11-01 00:00:00

  • Miniaturization of surface acoustic waves rotary motor.

    abstract::This paper presents the experimental study of a miniaturized surface acoustic waves (SAWs) rotary motor and the theoretical calculation. After the first success in SAW rotary motor operating at 9.85 MHz, a smaller rotary motor is designed. With the operating frequency of 30 MHz and the driving voltage of 120 V(p-p), t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00264-0

    authors: Cheng LP,Zhang GM,Zhang SY,Yu J,Shui XJ

    更新日期:2002-06-01 00:00:00

  • A critical assessment of the in-vitro measurement of cortical bone stiffness with ultrasound.

    abstract::Elasticity assessment based on bulk wave velocity (BWV) measurements is the most popular technique to characterize the anisotropic stiffness tensor in cortical bone. Typically, a cuboid bone specimen is cut with its sides along the different anatomical directions. Then, the velocity of shear and longitudinal waves pro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.05.009

    authors: Peralta L,Cai X,Laugier P,Grimal Q

    更新日期:2017-09-01 00:00:00

  • A reverse time migration-based multistep angular spectrum approach for ultrasonic imaging of specimens with irregular surfaces.

    abstract::We develop a new ultrasonic imaging framework for non-destructive testing of an immersed specimen featuring an irregular top surface and demonstrate its capability of accurately depicting the lower surfaces of multiple damages hidden in the specimen. Central to the framework is a multistep angular spectrum approach (A...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106233

    authors: Yang X,Wang K,Xu Y,Xu L,Hu W,Wang H,Su Z

    更新日期:2020-12-01 00:00:00

  • Investigation of ultrasonic absorption in the MHz frequency range by silicon substrates with a built-in porous silicon layer.

    abstract::The present study is focused on the development and characterization of an innovative substrate to optimize the axial resolution of ultrasonic transducers on a silicon substrate that is dedicated to ultrasound imaging. The substrate must efficiently dampen wave propagation to avoid degradation of the axial resolution ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.01.006

    authors: Lascaud J,Defforge T,Gautier G,Certon D

    更新日期:2019-07-01 00:00:00

  • Signal-to-noise ratio enhancement based on wavelet filtering in ultrasonic testing.

    abstract::In ultrasonic non-destructive testing of materials with a coarse-grained structure the scattering from the grains causes backscattering noise, which masks flaw echoes in the measured signal. Several filtering methods have been proposed for improving the signal-to-noise ratio. In this paper we present a comparative stu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.05.010

    authors: Matz V,Smid R,Starman S,Kreidl M

    更新日期:2009-12-01 00:00:00

  • The quasi-harmonic ultrasonic polar scan for material characterization: experiment and numerical modeling.

    abstract::Conventionally, the ultrasonic polar scan (UPS) records the amplitude or time-of-flight in transmission using short ultrasonic pulses for a wide range of incidence angles, resulting in a fingerprint of the critical bulk wave angles of the material at the insonified spot. Here, we investigate the use of quasi-harmonic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.002

    authors: Kersemans M,Martens A,Van Den Abeele K,Degrieck J,Pyl L,Zastavnik F,Sol H,Van Paepegem W

    更新日期:2015-04-01 00:00:00

  • Feature selection for neural network based defect classification of ceramic components using high frequency ultrasound.

    abstract::The motivation for this research stems from a need for providing a non-destructive testing method capable of detecting and locating any defects and microstructural variations within armour ceramic components before issuing them to the soldiers who rely on them for their survival. The development of an automated ultras...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.05.027

    authors: Kesharaju M,Nagarajah R

    更新日期:2015-09-01 00:00:00