Mutual conversion of bulk and surface acoustic waves in gratings of finite length on half-infinite substrates. I. FE analysis of surface wave generation.

Abstract:

:A numerical study is carried out of the surface acoustic wave generation by a bulk acoustic wave in a half-infinite anisotropic half-space without piezoeffect. The efficient conversion of bulk waves into surface waves occurs due to a grating area created on the surface of the substrate. Our simulations are fully based on the finite element method. Given the incident bulk wave, we directly determine the amplitude of the surface wave and investigate its dependence on various parameters specifying the situation under consideration, such as the frequency and the polarization of the bulk wave, the length of the grating, the geometrical size of grooves or strips forming the grating.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Darinskii AN,Weihnacht M,Schmidt H

doi

10.1016/j.ultras.2013.01.007

subject

Has Abstract

pub_date

2013-07-01 00:00:00

pages

998-1003

issue

5

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(13)00010-3

journal_volume

53

pub_type

杂志文章
  • Current topics on sonoelectrochemistry.

    abstract::Sonoelectrochemistry is undergoing a reemerging activity in the last years with an increasing number of papers appearing in a wide range of peer review journals. Applied studies which cover environmental treatments, synthesis or characterization of nanostructures, polymeric materials synthesis, analytical procedures, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.022

    authors: González-García J,Esclapez MD,Bonete P,Hernández YV,Garretón LG,Sáez V

    更新日期:2010-02-01 00:00:00

  • The influence of the thickness of non-piezoelectric pieces on pre-stressed piezotransducers.

    abstract::The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with differ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00096-9

    authors: Arnold FJ,Mühlen SS

    更新日期:2003-05-01 00:00:00

  • Dependence of ultrasonic velocity in rabbit liver on water content and structure of the tissue.

    abstract::This paper investigates the dependence of ultrasonic velocity in rabbit liver on the water content and tissue structure. The results obtained indicate that the composition and water content of the liver tissue but not its structure determine the value of velocity. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(87)90040-0

    authors: Sarvazyan AP,Lyrchikov AG,Gorelov SE

    更新日期:1987-07-01 00:00:00

  • High-intensity ultrasound irradiation promotes the release of extracellular vesicles from C2C12 myotubes.

    abstract::Skeletal muscle is an important secretory organ in mammals, producing myriad chemical mediators ("myokines") with distinct biological action in different tissues, including anti-inflammatory activity. Extracellular vesicles (EVs) have recently been identified as a mode of myokine transport from muscle, facilitating su...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106243

    authors: Maeshige N,Langston PK,Yuan ZM,Kondo H,Fujino H

    更新日期:2021-02-01 00:00:00

  • Weighted non-linear beamformers for low cost 2-element receive ultrasound imaging system.

    abstract::In this paper, the development of modified beamforming methods, Filtered Delay Weight Multiply and Sum (F-DwMAS) and Filtered Delay Euclidian-Weighted Multiply and Sum (F-DewMAS), are reported. These methods were investigated on a minimum-redundancy synthetic aperture technique, called as 2 element Receive Synthetic A...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106293

    authors: Vayyeti A,Thittai AK

    更新日期:2021-02-01 00:00:00

  • Numerical and experimental study on the wave attenuation in bone--FDTD simulation of ultrasound propagation in cancellous bone.

    abstract::In cancellous bone, longitudinal waves often separate into fast and slow waves depending on the alignment of bone trabeculae in the propagation path. This interesting phenomenon becomes an effective tool for the diagnosis of osteoporosis because wave propagation behavior depends on the bone structure. Since the fast w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.04.011

    authors: Nagatani Y,Mizuno K,Saeki T,Matsukawa M,Sakaguchi T,Hosoi H

    更新日期:2008-11-01 00:00:00

  • Architectures for ultrasonic planetary sample retrieval tools.

    abstract::Traditional rotary corers and sample retrieval mechanisms for planetary drilling suffer from a variety of technical difficulties. A heavy and rigid drillstring must be assembled on-site and deployed with considerable applied preload and torque, and these mechanical loadings are difficult to react in a low gravity envi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.06.001

    authors: Harkness P,Lucas M,Cardoni A

    更新日期:2011-12-01 00:00:00

  • The ultrasonic probe for the investigating of internal object structure by ultrasound transmission tomography.

    abstract::The main component of every device used for investigating internal object structure by Ultrasound Transmission Tomography (UTT) is a special ultrasonic probe. This paper presents the structure of model multielement ring probe for examining objects using this method in divergent ray projection geometry. The probe is ma...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.126

    authors: Gudra T,Opielinski KJ

    更新日期:2006-12-22 00:00:00

  • DC effects, sub-harmonics, stochasticity and "memory" for contact acoustic non-linearity.

    abstract::Acoustic wave interaction with non-bonded contacts was found to be inherently non-linear due to asymmetrical stiffness distribution across the interface. A diode-type non-linearity results in local static elastic fields inside the contact, which are shown to be a source of transient longitudinal and shear DC-acoustic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00241-x

    authors: Korshak BA,Solodov IY,Ballad EM

    更新日期:2002-05-01 00:00:00

  • Non-contact measurement of the thickness of a surface film using a superimposed ultrasonic standing wave.

    abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106291

    authors: Kanja J,Mills R,Li X,Brunskill H,Hunter AK,Dwyer-Joyce RS

    更新日期:2021-02-01 00:00:00

  • An improved Richardson-Lucy iterative algorithm for C-scan image restoration and inclusion size measurement.

    abstract::The accuracy of measuring inclusion size in direct C-scan image of immersion ultrasonic testing is restricted by the lateral resolution of the focused transducer, even if a high frequency is used, and the blurred edge due to scattering of sound waves at inclusions. In this work, an improved image restoration method th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.07.021

    authors: Chen D,Xiao H,Xu J

    更新日期:2019-01-01 00:00:00

  • Focused ultrasound phantom model for blood brain barrier disruption.

    abstract::In this paper a high intensity focused ultrasound (FUS) phantom model was developed, in order to be used in experiments for Blood Brain Barrier (BBB) disruption. The target was to create a phantom model that represents the disruption of the BBB during ultrasound application. An appropriate experimental setup was creat...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106244

    authors: Alekou T,Giannakou M,Damianou C

    更新日期:2021-02-01 00:00:00

  • High nonlinearities in Langevin transducer: a comprehensive model.

    abstract::The design and simulation of power transducers are difficult since piezoelectric, dielectric and elastic properties of ferroelectric materials differ from linear behavior when driven at large levels. This paper is devoted to modeling of a resonant power transducer at a high level of dynamic mechanical stress. The powe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.05.017

    authors: Guyomar D,Ducharne B,Sebald G

    更新日期:2011-12-01 00:00:00

  • A new optical method for the detection of in-plane motion of ultrasound propagating in metals.

    abstract::This paper describes a laser optical technique for the detection of in-plane (IP) motion of ultrasonic waves propagating in solids. This interference-based laser optical technique includes a tiny square indentation with a width of about 30 microm on the sample surface and a relatively simple optical arrangement. The c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.076

    authors: Yang CH,Tsai YC

    更新日期:2006-12-22 00:00:00

  • Thin-disk piezoceramic ultrasonic motor. Part I: design and performance evaluation.

    abstract::The purpose of this study is to gain the knowledge and experience in the design of thin-disk piezoceramic-driving ultrasonic actuator dedicated. In this paper, the design and construction of an innovative ultrasonic actuator is developed as a stator, which is a composite structure consisting of piezoceramic (PZT) memb...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00128-8

    authors: Wen FL,Yen CY,Ouyang M

    更新日期:2003-08-01 00:00:00

  • Finite element modeling of grain size effects on the ultrasonic microstructural noise backscattering in polycrystalline materials.

    abstract::The correlation between ultrasonic wave propagation and polycrystalline microstructures has significant implications in nondestructive evaluation. An original numerical approach using the finite element method to quantify in both time and frequency domains the ultrasonic noise scattering due to the elastic heterogenei...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.02.008

    authors: Bai X,Tie B,Schmitt JH,Aubry D

    更新日期:2018-07-01 00:00:00

  • Autocorrelation-based generalized coherence factor for low-complexity adaptive beamforming.

    abstract:BACKGROUND:Generalized coherence factor (GCF) can be adaptively estimated from channel data to suppress sidelobe artifacts. Conventionally, Fast Fourier Transform (FFT) is utilized to calculate the full channel spectrum and suffers from high computation load. In this work, autocorrelation (AR)-based algorithm is utiliz...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.07.015

    authors: Shen CC,Xing YQ,Jeng G

    更新日期:2016-12-01 00:00:00

  • Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels.

    abstract::Experimental studies of thermal effects in high-intensity focused ultrasound (HIFU) procedures are often performed with the aid of fine wire thermocouples positioned within tissue phantoms. Thermocouple measurements are subject to several types of error which must be accounted for before reliable inferences can be mad...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.07.007

    authors: Dasgupta S,Banerjee RK,Hariharan P,Myers MR

    更新日期:2011-02-01 00:00:00

  • Determining sodium diffusion through acoustic impedance measurements using 80 MHz Scanning Acoustic Microscopy: Agarose phantom verification.

    abstract::The purpose of this study is to explore the feasibility of time-dependent acoustic impedance measurement by Scanning Acoustic Microscopy (SAM) for analyzing the sodium diffusion. The purpose is motivated by the fact that sodium monitoring is challenging and still in the area of exploratory analysis despite its biologi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.12.013

    authors: Demirkan I,Unlu MB,Bilen B

    更新日期:2019-04-01 00:00:00

  • Polymeric contrast agent with targeting potential.

    abstract::The Arg-Gly-Asp (RGD) peptide sequence was conjugated to poly (lactid acid), (PLA), microcapsules. These hollow, biodegradable PLGA microcapsules were developed in our laboratory for use as ultrasound contrast agents. By modifying the surface of the agent with a targeting ligand, it can be targeted to a specific addre...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.018

    authors: Lathia JD,Leodore L,Wheatley MA

    更新日期:2004-04-01 00:00:00

  • Investigating ultrasound-induced acoustic softening in aluminum and its alloys.

    abstract::Ultrasonic vibration has been observed to lower the flow stress necessary to initiate plastic deformation, a phenomenon known as "acoustic softening". This unique effect of ultrasound has been extensively applied in welding, machining, forming of metals, and ultrasonic additive manufacturing to lower the yield stress ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.106005

    authors: Mao Q,Coutris N,Rack H,Fadel G,Gibert J

    更新日期:2020-03-01 00:00:00

  • Nonlinear coda wave interferometry for the global evaluation of damage levels in complex solids.

    abstract::A nonlinear acoustic method to assess the damage level of a complex medium is discussed herein. Thanks to the highly nonlinear elastic signatures of cracks or, more generally, internal solid contacts, this method is able to distinguish between contributions from linear wave scattering by a heterogeneity and contributi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.09.015

    authors: Zhang Y,Tournat V,Abraham O,Durand O,Letourneur S,Le Duff A,Lascoup B

    更新日期:2017-01-01 00:00:00

  • Fabrication and comparison of PMN-PT single crystal, PZT and PZT-based 1-3 composite ultrasonic transducers for NDE applications.

    abstract::This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acousti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.04.001

    authors: Kim KB,Hsu DK,Ahn B,Kim YG,Barnard DJ

    更新日期:2010-08-01 00:00:00

  • A combined linear and nonlinear ultrasound time-domain approach for impact damage detection in composite structures using a constructive nonlinear array technique.

    abstract::Discovery and evaluation concerns of barely visible impact damage in composite materials is a well-known issue in industries using these materials. This work proposes a frequency sweep method where damage assessment is conducted with respect to the time domain. Firstly, a combined linear and nonlinear ultrasound imagi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.10.011

    authors: Malfense Fierro GP,Meo M

    更新日期:2019-03-01 00:00:00

  • Long-path measurements of ultrasonic attenuation and velocity for very dilute slurries and liquids and detection of contaminates.

    abstract::The objective was to use multiple paths through the slurry to determine the lowest concentration that provided accurate attenuation measurements and to measure the velocity of sound through an effective long path. Ultrasonic attenuation measurements were obtained for slurries of silica (10 microm diameter) in water fo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.024

    authors: Greenwood MS,Adamson JD,Bamberger JA

    更新日期:2006-12-22 00:00:00

  • Low- and high-frequency nonlinear acoustic phenomena in a magnesite.

    abstract::The results of experimental and theoretical studies of nonlinear acoustic phenomena (amplitude-dependent losses, resonant frequency shifts, damping of weak ultrasonic pulses and their carrier frequency phase delay under action of a powerful low-frequency pumping wave as well as amplitude-phase self-action of the finit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.07.008

    authors: Nazarov VE,Kolpakov AB

    更新日期:2014-02-01 00:00:00

  • An improved approximation for the Rayleigh wave equation.

    abstract::We derive a simple expression, which gives an approximate value of the Rayleigh wave velocity in an isotropic solid. This approximation is five times better than that given by Viktorov. The velocity equation can be easily inverted in order to obtain an accurate determination of the elastic constants. This procedure ca...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.006

    authors: Royer D,Clorennec D

    更新日期:2007-03-01 00:00:00

  • Speckle tracking for multi-dimensional flow estimation.

    abstract::Speckle tracking methods overcome the major limitations of current Doppler methods for flow imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages and limitations of two-dimensional algorithms that use a singl...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00182-1

    authors: Bohs LN,Geiman BJ,Anderson ME,Gebhart SC,Trahey GE

    更新日期:2000-03-01 00:00:00

  • Tandem shock waves to enhance genetic transformation of Aspergillus niger.

    abstract::Filamentous fungi are used in several industries and in academia to produce antibiotics, metabolites, proteins and pharmaceutical compounds. The development of valuable strains usually requires the insertion of recombinant deoxyribonucleic acid; however, the protocols to transfer DNA to fungal cells are highly ineffic...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.003

    authors: Loske AM,Fernández F,Magaña-Ortíz D,Coconi-Linares N,Ortíz-Vázquez E,Gómez-Lim MA

    更新日期:2014-08-01 00:00:00

  • Non-contact ultrasonic gas flow metering using air-coupled leaky Lamb waves.

    abstract::This paper describes a completely non-contact ultrasonic method of gas flow metering using air-coupled leaky Lamb waves. To show proof of principle, a simplified representation of gas flow in a duct, comprising two separated thin isotropic plates with a gas flowing between them, has been modelled and investigated expe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.04.008

    authors: Fan Z,Jiang W,Wright WMD

    更新日期:2018-09-01 00:00:00