Investigating ultrasound-induced acoustic softening in aluminum and its alloys.

Abstract:

:Ultrasonic vibration has been observed to lower the flow stress necessary to initiate plastic deformation, a phenomenon known as "acoustic softening". This unique effect of ultrasound has been extensively applied in welding, machining, forming of metals, and ultrasonic additive manufacturing to lower the yield stress necessary to initiate plastic deformation, it nevertheless lacks fundamental investigation. Some prior studies showed experimental errors due to the design of experimental setups and the associated testing methods that have been introduced, leading to questions about their observations and conclusions. Therefore, an experimental setup described in this paper is designed to minimize the constraints identified from the setups in prior studies. Three types of aluminum are studied: Al 1100-O a commercially pure aluminum, Al 6061-O an aluminum alloy without precipitate strengthening, and Al 6061-T6 a precipitate-strengthened aluminum alloy. The acoustic softening and residual effect are compared based on the similarities and differences in microstructures of the three types of aluminum. In both acoustic softening and residual effect, linear relations are obtained between stress change and ultrasound intensities. The slope defined by the linear relations, i.e. the acoustic softening factor, depends on the microstructure of the specific material. The underlying mechanism of acoustic softening is associated with the activation of dislocations by ultrasonic energy and subsequently their interactions with other dislocations and precipitates, whereas the residual effects are attributed to the permanent changes in dislocation density due to dislocation annihilation, dynamic annealing, and dislocation-precipitate interaction.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Mao Q,Coutris N,Rack H,Fadel G,Gibert J

doi

10.1016/j.ultras.2019.106005

subject

Has Abstract

pub_date

2020-03-01 00:00:00

pages

106005

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(19)30062-9

journal_volume

102

pub_type

杂志文章
  • Sensitivity improvement of a pump-probe set-up for thin film and microstructure metrology.

    abstract::This investigation deals with various new aspects of the sensitivity improvement of a pump-probe laser based acoustic method. A short laser pulse is used to excite a mechanical pulse thermo-elastically. Echoes of these mechanical pulses reaching the surface are causing a slight change of the optical reflectivity. The ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00207-x

    authors: Vollmann J,Profunser DM,Dual J

    更新日期:2002-05-01 00:00:00

  • A critical assessment of the in-vitro measurement of cortical bone stiffness with ultrasound.

    abstract::Elasticity assessment based on bulk wave velocity (BWV) measurements is the most popular technique to characterize the anisotropic stiffness tensor in cortical bone. Typically, a cuboid bone specimen is cut with its sides along the different anatomical directions. Then, the velocity of shear and longitudinal waves pro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.05.009

    authors: Peralta L,Cai X,Laugier P,Grimal Q

    更新日期:2017-09-01 00:00:00

  • Diagnostic ultrasound artifacts during imaging of two-body interfaces: part 2--beam thickness artifact.

    abstract::A diagnostic ultrasound method is being developed for measuring surface contact areas at the tibio-femoral interface of a total knee replacement in a non-clinical industrial setting as an engineering design tool. As an initial step towards this, a previous study mathematically predicted the effect of ultrasound beam t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00382-7

    authors: Zdero R,Fenton PV,Bryant JT

    更新日期:2002-10-01 00:00:00

  • Dynamic modeling and experimental verification of a piezoelectric part feeder in a structure with parallel bimorph beams.

    abstract::The study is aimed to perform dynamic modeling of a part feeder powered by piezoelectric actuation. This part feeder consists mainly of a horizontal platform vibrated by a pair of parallel piezoelectric bimorph beams. Owing to intermittent impacts with the platform, the transported part on the platform is able to marc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.02.002

    authors: Chao PC,Shen CY

    更新日期:2007-06-01 00:00:00

  • State-of-the-art surface acoustic wave linear motor and its future applications

    abstract::Two merits of the surface acoustic wave (SAW) device are its high energy density and small size. However, the driving frequency is around 10 MHz or higher. In spite of the difficulties involved with high frequency, the high energy density is attractive for actuator applications. The SAW linear motor's no load speed an...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00087-6

    authors: Kurosawa MK

    更新日期:2000-03-01 00:00:00

  • In vitro chronic hepatic disease characterization with a multiparametric ultrasonic approach.

    abstract::Although, high resolution, real-time ultrasonic (US) imaging is routinely available, image interpretation is based on grey-level and texture and quantitative evaluation is limited. Other potentially useful diagnostic information from US echoes may include modifications in tissue acoustic parameters (speed, attenuation...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.09.002

    authors: Meziri M,Pereira WC,Abdelwahab A,Degott C,Laugier P

    更新日期:2005-03-01 00:00:00

  • Modelling and simulation of acoustic wave propagation in locally resonant sonic materials.

    abstract::Sonic crystals are artificial structures consisting of a periodic array of acoustic scatterers embedded in a homogeneous matrix material, with a usually large impedance mismatch between the two materials. They exhibit strong sound attenuation at selective frequency bands due to the interference of multiply reflected w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.014

    authors: Hirsekorn M,Delsanto PP,Batra NK,Matic P

    更新日期:2004-04-01 00:00:00

  • Research interface on a programmable ultrasound scanner.

    abstract:MOTIVATION:Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. OBJECTIVES:Recently, we developed a flexible ultrasound back-end where all th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.11.009

    authors: Shamdasani V,Bae U,Sikdar S,Yoo YM,Karadayi K,Managuli R,Kim Y

    更新日期:2008-07-01 00:00:00

  • Nondestructive evaluation of steel-concrete composite structure using high-frequency ultrasonic guided wave.

    abstract::Steel-concrete modular construction is increasingly used in nuclear structure construction. Conventional nondestructive testing methods are not able to detect internal concrete defects because the thick concrete wall is covered by steel plates. An ultrasonic guided method is proposed to detect honeycombs and voids aro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106096

    authors: Sun H,Zhu J

    更新日期:2020-04-01 00:00:00

  • 2D array design based on Fermat spiral for ultrasound imaging.

    abstract::The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.010

    authors: Martínez-Graullera O,Martín CJ,Godoy G,Ullate LG

    更新日期:2010-02-01 00:00:00

  • Eight-channel ultrasonic device for non-invasive quality evaluation in packed milk.

    abstract::An eight-channel ultrasonic detecting device for microbiological quality evaluation of packed liquid foods is presented in this paper. This device makes possible a non-invasive detection of the microbial growth in liquid foods with no need to open the carton-based packages where they are contained. Thermal and humidit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.011

    authors: Elvira L,Sampedro L,Montero de Espinosa F,Matesanz J,Gómez-Ullate Y,Resa P,Echevarría FJ,Iglesias JR

    更新日期:2006-12-01 00:00:00

  • Spatial-temporal three-dimensional ultrasound plane-by-plane active cavitation mapping for high-intensity focused ultrasound in free field and pulsatile flow.

    abstract::Cavitation plays important roles in almost all high-intensity focused ultrasound (HIFU) applications. However, current two-dimensional (2D) cavitation mapping could only provide cavitation activity in one plane. This study proposed a three-dimensional (3D) ultrasound plane-by-plane active cavitation mapping (3D-UPACM)...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.010

    authors: Ding T,Hu H,Bai C,Guo S,Yang M,Wang S,Wan M

    更新日期:2016-07-01 00:00:00

  • Modeling electrical response of polymer-coated SAW resonators by equivalent circuit representation.

    abstract::The paper presents an equivalent circuit model of the polymer coated surface acoustic wave (SAW) resonators by combining coupling-of-mode (COM) description of SAW resonators and perturbation calculation of SAW propagation under polymer loading. An expression for the motional load produced by polymer coating is deduced...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.12.006

    authors: Kshetrimayum R,Yadava RD,Tandon RP

    更新日期:2011-07-01 00:00:00

  • Acoustic source localization in a highly anisotropic plate with unknown orientation of its axes of symmetry and material properties with numerical verification.

    abstract::Development of acoustic source localization techniques in anisotropic plates has gained attention in the recent past and still has scope of improvement. Most of such techniques existing in the literature either require known material properties or assume a straight line propagation of wave energy from the acoustic sou...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105977

    authors: Sen N,Kundu T

    更新日期:2020-01-01 00:00:00

  • Ultrasonic flaw detection using threshold modified S-transform.

    abstract::Interference noising originating from the ultrasonic testing defect signal seriously influences the accuracy of the signal extraction and defect location. Time-frequency analysis methods are mainly used to improve the defects detection resolution. In fact, the S-transform, a hybrid of the Short time Fourier transform ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.004

    authors: Benammar A,Drai R,Guessoum A

    更新日期:2014-02-01 00:00:00

  • Some studies on evaluation of degradation in composite adhesive joints using ultrasonic techniques.

    abstract::Experimental and theoretical studies on degradation of composite-epoxy adhesive joints were carried out on samples having different interfacial and cohesive properties. Oblique incidence ultrasonic inspection of bonded joints revealed that degradation in the adhesive can be measured by significant variation in reflect...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.01.014

    authors: Vijaya Kumar RL,Bhat MR,Murthy CR

    更新日期:2013-08-01 00:00:00

  • Applications of a nanocomposite-inspired in-situ broadband ultrasonic sensor to acousto-ultrasonics-based passive and active structural health monitoring.

    abstract::A novel nanocomposite-inspired in-situ broadband ultrasonic sensor previously developed, with carbon black as the nanofiller and polyvinylidene fluoride as the matrix, was networked for acousto-ultrasonic wave-based passive and active structural health monitoring (SHM). Being lightweight and small, this kind of sensor...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.007

    authors: Liu M,Zeng Z,Xu H,Liao Y,Zhou L,Zhang Z,Su Z

    更新日期:2017-07-01 00:00:00

  • Sound field separating on arbitrary surfaces enclosing a sound scatterer based on combined integral equations.

    abstract::To eliminate the limitations of the conventional sound field separation methods which are only applicable to regular surfaces, a sound field separation method based on combined integral equations is proposed to separate sound fields directly in the spatial domain. In virtue of the Helmholtz integral equations for the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.06.007

    authors: Fan Z,Mei D,Yang K,Chen Z

    更新日期:2014-12-01 00:00:00

  • Numerical predictions and experiments for optimizing hidden corrosion detection in aircraft structures using Lamb modes.

    abstract::To increase the sensitivity of Lamb waves to hidden corrosion in aircraft structures, a preliminary step is to understand the phenomena governing this interaction. A hybrid model combining a finite element approach and a modal decomposition method is used to investigate the interaction of Lamb modes with corrosion pit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.02.004

    authors: Terrien N,Royer D,Lepoutre F,Déom A

    更新日期:2007-06-01 00:00:00

  • Induction of stress fibres and intercellular gaps in human vascular endothelium by shock-waves.

    abstract::Human umbilical cords were exposed to high amplitude focussed ultrasonic pulses with focal energy densities 0.6 and 0.4 mJ mm-2. The endothelium of the exposed vessel (vein) was examined by means of confocal laser scanning microscopy and scanning electron microscopy. The degree of tissue change ranged from the inducti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(94)90111-2

    authors: Seidl M,Steinbach P,Wörle K,Hofstädter F

    更新日期:1994-09-01 00:00:00

  • Application of low intensity ultrasonics to cheese manufacturing processes.

    abstract::Ultrasound has been used to non-destructively assess the quality of many foods such as meat, fish, vegetables and dairy products. This paper addresses the applications of low intensity ultrasonics in the cheese manufacturing processes and highlights the areas where ultrasonics could be successfully implemented in the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00085-9

    authors: Benedito J,Carcel JA,Gonzalez R,Mulet A

    更新日期:2002-05-01 00:00:00

  • Transverse (lateral) instantaneous force of an acoustical first-order Bessel vortex beam centered on a rigid sphere.

    abstract::In a recent report [F.G. Mitri, Z.E.A. Fellah, Ultrasonics 51 (2011) 719-724], it has been found that the instantaneous axial force (i.e. acting along the axis of wave propagation) of a Bessel acoustic beam centered on a sphere is only determined for the fundamental order (i.e. m=0) but vanishes when the beam is of vo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.07.009

    authors: Mitri FG,Fellah ZE

    更新日期:2012-01-01 00:00:00

  • Location of multiple proximate flaws using perpendicular NDT ultrasonic arrays.

    abstract::An improved method for ultrasonic location of multiple flaws using perpendicular ultrasonic arrays, working in near-field conditions, is presented. The method uses the pulse-echo technique and is based on the processing of the information acquired by both the elemental emitting transducers and their adjacent ones. Thi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.107

    authors: Rodríguez MA,Ramos A,San Emeterio JL

    更新日期:2006-12-22 00:00:00

  • Effect of spatial dispersion on transient acoustic wave propagation in 3D.

    abstract::Spatial dispersion is the variation of wave speed with wavelength. It sets in when the acoustic wavelength approaches the natural scale of length of the medium, which could, for example, be the lattice constant of a crystal, the repeat distance in a superlattice, or the grain size in a granular material. In centrosymm...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.215

    authors: Every AG

    更新日期:2006-12-22 00:00:00

  • Effect of the microstructure on the propagation velocity of ultrasound in magnetic powders.

    abstract::We analyze experimentally and theoretically the sound propagation velocity of P-waves in granular media made of micrometer-size magnetite particles under an external magnetic field. The sound velocity is measured in a coherent (long-wavelength) regime of propagation after a controlled sample preparation consisting of ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.07.021

    authors: Botello FR,Quintanilla MAS,Castellanos A,Grekova EF,Tournat V

    更新日期:2018-01-01 00:00:00

  • Coating thickness affects surface stress measurement of brush electro-plating nickel coating using Rayleigh wave approach.

    abstract::A surface ultrasonic wave approach was presented for measuring surface stress of brush electro-plating nickel coating specimen, and the influence of coating thickness on surface stress measurement was discussed. In this research, two Rayleigh wave transducers with 5MHz frequency were employed to collect Rayleigh wave ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.02.003

    authors: Liu B,Dong S,Xu B,He P

    更新日期:2012-09-01 00:00:00

  • Evaluation of crack parameters by a nonlinear frequency-mixing laser ultrasonics method.

    abstract::The local evaluation of several parameters of a crack is realized with a nonlinear laser ultrasonic method. The method is based on the sample excitation by two laser beams, independently intensity modulated at two cyclic frequencies ωH and ωL (ωH≫ωL) and on the detection of nonlinear frequency-mixing ultrasonic compon...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.005

    authors: Mezil S,Chigarev N,Tournat V,Gusev V

    更新日期:2016-07-01 00:00:00

  • Optimized ultrasonic attenuation measures for non-homogeneous materials.

    abstract::In this paper the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous materials is addressed. To determine the attenuation accurately over a wide frequency range, it is necessary to have suitable excitation techniques. Three kinds of transmitted signals have been analysed, grouped according t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.09.007

    authors: Genovés V,Gosálbez J,Carrión A,Miralles R,Payá J

    更新日期:2016-02-01 00:00:00

  • Ultrasonic digital interferometer for investigation of blood clotting.

    abstract::The digital ultrasonic fixed path interferometer designed for testing small amounts of sample was used for the investigation of whole blood coagulation, retraction and clot melting processes. The ultrasound velocity and absorption are determined from the characteristics of an acoustic resonator consisting of an emitte...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(78)90007-0

    authors: Grybauskas P,Kundrotas K,Sukackas V,Yaronis E

    更新日期:1978-01-01 00:00:00

  • Elastic constant determination of hardwoods using ultrasonic insertion technique.

    abstract::Ultrasonic insertion technique (IT) is an ultrasonic technique which involves sample immersion in a solution to determine its acoustic properties. IT is normally used to determine the acoustic properties of a medical phantom. We proposed the use of IT as an alternative technique to the common contact ultrasonic techni...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.025

    authors: Mat Daud AN,Jaafar R,Ayop SK,Yaacob MIH,Rohani MS

    更新日期:2017-03-01 00:00:00