Finite element modeling of grain size effects on the ultrasonic microstructural noise backscattering in polycrystalline materials.

Abstract:

:The correlation between ultrasonic wave propagation and polycrystalline microstructures has significant implications in nondestructive evaluation. An original numerical approach using the finite element method to quantify in both time and frequency domains the ultrasonic noise scattering due to the elastic heterogeneity of polycrystalline microstructures is presented. Based on the reciprocity theorem, it allows the scattering evaluation using mechanical data recorded only on the boundary of polycrystal instead of within its volume and is applicable to any polycrystalline aggregate regardless of its crystallographic or morphological characteristics. Consequently it gives a more realistic and accurate access of polycrystalline microstructures than the classical analytical models developed under the assumption of single scattering and the Born approximation. The numerical approach is proposed within the same unified theoretical framework as the classical analytical models, so it is possible to validate it in the cases of idealized microstructures for which the considered analytical models remain relevant. As an original result, assuming single phase, untextured and equiaxed microstructures, two-dimensional (2D) theoretical formulas are developed and a frequency-dependent coefficient is found compared to the classical three-dimensional (3D) formulas. 2D numerical simulations are then performed for idealized microstructures composed of hexagonal grains with a uniform grain-size. Three grain sizes are considered herein and involve different scattering regions. Good comparisons are obtained between theoretical and numerical estimates of the backscattering coefficient, which validate the numerical approach. Effects of the grain boundary orientations are analyzed by modeling an irregular hexagonal grain morphology and a random grain morphology generated by an established Voronoi approach. The origin of the significant oscillation level of backscattering is then investigated and discussed.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Bai X,Tie B,Schmitt JH,Aubry D

doi

10.1016/j.ultras.2018.02.008

subject

Has Abstract

pub_date

2018-07-01 00:00:00

pages

182-202

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(18)30106-9

journal_volume

87

pub_type

杂志文章
  • Experiment and numerical simulation for laser ultrasonic measurement of residual stress.

    abstract::Laser ultrasonic is a most promising method for non-destructive evaluation of residual stress. The residual stress of thin steel plate is measured by laser ultrasonic technique. The pre-stress loading device is designed which can easily realize the condition of the specimen being laser ultrasonic tested at the same ti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.08.013

    authors: Zhan Y,Liu C,Kong X,Lin Z

    更新日期:2017-01-01 00:00:00

  • Micromachined ultrasound transducers with improved coupling factors from a CMOS compatible process

    abstract::For medical high frequency acoustic imaging purposes the reduction in size of a single transducer element for one-dimensional and even more for two-dimensional arrays is more and more limited by fabrication and cabling technology. In the fields of industrial distance measurement and simple object recognition low cost ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00085-2

    authors: Eccardt PC,Niederer K

    更新日期:2000-03-01 00:00:00

  • Generation of sub-microsecond quasi-unipolar pressure pulses.

    abstract::We present a method to generate sub-microsecond quasi-unipolar pressure pulses. Our approach is based on the laser irradiation of a thin copper wire submerged in water. The acoustic waveforms were recorded using two different, well characterized, wideband detection techniques: piezoelectric and optical interferometry....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.05.002

    authors: González MG,Riobó LM,Ciocci Brazzano L,Veiras FE,Sorichetti PA,Santiago GD

    更新日期:2019-09-01 00:00:00

  • Micro-scale finite element modeling of ultrasound propagation in aluminum trabecular bone-mimicking phantoms: A comparison between numerical simulation and experimental results.

    abstract::The present study investigated the accuracy of micro-scale finite element modeling for simulating broadband ultrasound propagation in water-saturated trabecular bone-mimicking phantoms. To this end, five commercially manufactured aluminum foam samples as trabecular bone-mimicking phantoms were utilized for ultrasonic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.01.014

    authors: Vafaeian B,Le LH,Tran TN,El-Rich M,El-Bialy T,Adeeb S

    更新日期:2016-05-01 00:00:00

  • Propagation of thickness shear waves in a periodically corrugated quartz crystal plate and its application exploration in acoustic wave filters.

    abstract::The propagation of thickness shear waves in a periodically corrugated quartz crystal plate is investigated in the present paper using a power series expansion technique. In the proposed simulation model, an equivalent continuity of shear stress moment is introduced as an approximation to handle sectional interfaces wi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.004

    authors: Li P,Cheng L

    更新日期:2017-05-01 00:00:00

  • Ultrasonic elastography using sector scan imaging and a radial compression.

    abstract::Elastography is an imaging technique based on strain estimation in soft tissues under quasi-static compression. The stress is usually created by a compression plate, and the target is imaged by an ultrasonic linear array. This configuration is used for breast elastography, and has been investigated both theoretically ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00228-7

    authors: Souchon R,Soualmi L,Bertrand M,Chapelon JY,Kallel F,Ophir J

    更新日期:2002-05-01 00:00:00

  • Application of the ultrasonic waves in structural investigation of ferrofluid.

    abstract::It has been established that structural changes in a ferrofluid (formation of clusters) upon the effect of an external magnetic field can be effectively studied by ultrasound spectroscopy. In particular, the resonance absorption of ultrasonic waves enables detection and determination of the size of spherical clusters....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00117-8

    authors: Józefczak A,Skumiel A,Hornowski T

    更新日期:2002-05-01 00:00:00

  • Wide bandwidth fiber-optic ultrasound probe in MOMS technology: Preliminary signal processing results.

    abstract::An ultrasonic probe consisting of two optical fiber-based miniaturized transducers for wideband ultrasound emission and detection is employed for the characterization of in vitro biological tissues. In the probe, ultrasound generation is obtained by thermoelastic emission from patterned carbon films in Micro-Opto-Mech...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.024

    authors: Vannacci E,Granchi S,Belsito L,Roncaglia A,Biagi E

    更新日期:2017-03-01 00:00:00

  • Bubble oscillation and inertial cavitation in viscoelastic fluids.

    abstract::Non-linear acoustic oscillations of gas bubbles immersed in viscoelastic fluids are theoretically studied. The problem is formulated by considering a constitutive equation of differential type with an interpolated time derivative. With the aid of this rheological model, fluid elasticity, shear thinning viscosity and e...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2005.03.010

    authors: Jiménez-Fernández J,Crespo A

    更新日期:2005-08-01 00:00:00

  • Excitation and detection of evanescent acoustic waves in piezoelectric plates: Theoretical and 2D FEM modeling.

    abstract::This paper presents the results of the theoretical and 2D FEM modeling excitation and detection of evanescent acoustic waves in piezoelectric plates. By application of 2D ordinary differential equations derived by Auld, we obtained the dispersion curves of A1 and SH1 waves in YX LiNbO3 and YX KNbO3 plates in proximity...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105961

    authors: Kuznetsova I,Nedospasov I,Smirnov A,Qian ZH,Wang B,Dai XY

    更新日期:2019-11-01 00:00:00

  • Real-time on-line ultrasonic monitoring for bubbles in ceramic 'slip' in pottery pipelines.

    abstract::When casting ceramic items in potteries, liquid 'slip' is passed from a settling tank, through overhead pipelines, before being pumped manually into the moulds. It is not uncommon for bubbles to be introduced into the slip as it passes through the complex piping network, and indeed the presence of bubbles is a major s...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.07.008

    authors: Yim GT,Leighton TG

    更新日期:2010-01-01 00:00:00

  • Determining sodium diffusion through acoustic impedance measurements using 80 MHz Scanning Acoustic Microscopy: Agarose phantom verification.

    abstract::The purpose of this study is to explore the feasibility of time-dependent acoustic impedance measurement by Scanning Acoustic Microscopy (SAM) for analyzing the sodium diffusion. The purpose is motivated by the fact that sodium monitoring is challenging and still in the area of exploratory analysis despite its biologi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.12.013

    authors: Demirkan I,Unlu MB,Bilen B

    更新日期:2019-04-01 00:00:00

  • Transient displacement induced in shear wave elastography: comparison between analytical results and ultrasound measurements.

    abstract::It is now accepted that an effective way to investigate the elastic properties of soft tissues is to generate a localized transient acoustic radiation force and to follow the associated displacements in the time/space domain. Shear waves induced by this stress field are particularly interesting in this kind of medium ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.022

    authors: Elkateb Hachemi M,Callé S,Remenieras JP

    更新日期:2006-12-22 00:00:00

  • Ultrasonic measurements on poroelastic slabs: determination of reflection and transmission coefficients and processing for Biot input parameters.

    abstract::Ultrasonic reflection and transmission measurements on saturated, plane-parallel, poroelastic slabs are presented. A data processing technique is proposed to obtain poroelastic parameters from transmission measurements. A special experimental data acquisition and processing technique is applied to minimize the finite ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.006

    authors: Jocker J,Smeulders D

    更新日期:2009-03-01 00:00:00

  • Surface and quasi-longitudinal acoustic waves in KTiOAsO₄ single crystals.

    abstract::Surface and quasi-longitudinal acoustic wave properties have been investigated in potassium titanyl arsenate (KTiOAsO₄, KTA) single crystals for the first time. Surface acoustic wave (SAW) velocity, electromechanical coupling coefficient and power flow angle characteristics have been obtained in rotated Y-cut of KTA c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.019

    authors: Taziev RM

    更新日期:2014-02-01 00:00:00

  • Acousto-optic interaction with leaky surface acoustic waves in Y-cut LiTaO3 crystals.

    abstract::The acousto-optic interaction with leaky surface acoustic wave radiation into the bulk of YX-cut LiTaO(3) crystals has been investigated. The light incidence and diffraction angles corresponding to the strongest acousto-optic interaction were calculated and measured as functions of the acoustic wave frequency. The dep...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.12.004

    authors: Belovickis J,Rimeika R,Ciplys D

    更新日期:2012-07-01 00:00:00

  • Probing the limits of full-field linear local defect resonance identification for deep defect detection.

    abstract::Local Defect Resonance (LDR) is exploited for non-destructive testing (NDT) by using ultrasonic vibrations to get a localized resonant activation of defected zones. The LDR technique relies on the local stiffness difference between the defect and the sound material. Analyzing the structure's displacement field at this...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106130

    authors: Segers J,Hedayatrasa S,Poelman G,Van Paepegem W,Kersemans M

    更新日期:2020-07-01 00:00:00

  • Ultrasonic digital interferometer for investigation of blood clotting.

    abstract::The digital ultrasonic fixed path interferometer designed for testing small amounts of sample was used for the investigation of whole blood coagulation, retraction and clot melting processes. The ultrasound velocity and absorption are determined from the characteristics of an acoustic resonator consisting of an emitte...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(78)90007-0

    authors: Grybauskas P,Kundrotas K,Sukackas V,Yaronis E

    更新日期:1978-01-01 00:00:00

  • Thallium bromide iodide crystal acoustic anisotropy examination.

    abstract::Thallium bromide iodide crystal also known as KRS-5 is the well known material used in far infrared radiation applications for optical windows and lenses fabrication. The main advantage of this material is the transparency in wide band of wavelengths from 0.53 to 50μm. Despite such advantages as transparency and large...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.019

    authors: Mantsevich SN

    更新日期:2017-03-01 00:00:00

  • Stability of alteplase in presence of cavitation.

    abstract::Several experimental studies have demonstrated that ultrasound (US) can accelerate enzymatic fibrinolysis and this effect is further enhanced in the presence of ultrasound contrast agents (UCA). Although UCA have been shown to be safe when administered to ischemic stroke patients, safety information of these agents in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.10.003

    authors: Soltani A,Prokop AF,Vaezy S

    更新日期:2008-04-01 00:00:00

  • Applications of a nanocomposite-inspired in-situ broadband ultrasonic sensor to acousto-ultrasonics-based passive and active structural health monitoring.

    abstract::A novel nanocomposite-inspired in-situ broadband ultrasonic sensor previously developed, with carbon black as the nanofiller and polyvinylidene fluoride as the matrix, was networked for acousto-ultrasonic wave-based passive and active structural health monitoring (SHM). Being lightweight and small, this kind of sensor...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.007

    authors: Liu M,Zeng Z,Xu H,Liao Y,Zhou L,Zhang Z,Su Z

    更新日期:2017-07-01 00:00:00

  • Sensitivity of a miniaturized touch probe sensor using PZT thin film vibrator.

    abstract::In this paper, an improved touch probe sensor device for higher sensitivity and low contact force is reported. In order to improve the resolution, we have evaluated the sensitivity and fabricated a miniaturized sensor. The sensor transducer was 3 mm long and had higher resonance frequency. The resonance frequency of t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00091-4

    authors: Kanda T,Kurosawa MK,Higuchi T

    更新日期:2002-05-01 00:00:00

  • Guided wave propagation in a honeycomb composite sandwich structure in presence of a high density core.

    abstract::A coordinated theoretical, numerical and experimental study is carried out in an effort to interpret the characteristics of propagating guided Lamb wave modes in presence of a high-density (HD) core region in a honeycomb composite sandwich structure (HCSS). Initially, a two-dimensional (2D) semi-analytical model based...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.05.025

    authors: Sikdar S,Banerjee S

    更新日期:2016-09-01 00:00:00

  • Improving accuracy of acoustic source localization in anisotropic plates.

    abstract::The acoustic source localization technique for anisotropic plates proposed by the authors in an earlier publication ([1] Kundu et al., 2012) is improved in this paper by adopting some modifications. The improvements are experimentally verified on anisotropic flat and curved composite plates. Difficulties associated wi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.001

    authors: Nakatani H,Kundu T,Takeda N

    更新日期:2014-09-01 00:00:00

  • A comparative analysis of multi-pulse techniques in contrast-enhanced ultrasound medical imaging.

    abstract::One of the important issues in the field of ultrasound medical imaging using contrast agents is the development of techniques able to separate the response of the contrast media from that of the biological tissues. In the literature, one can find various solutions involving the use of multiple transmitted signals and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.05.008

    authors: Crocco M,Palmese M,Sciallero C,Trucco A

    更新日期:2009-01-01 00:00:00

  • Effect of the microstructure on the propagation velocity of ultrasound in magnetic powders.

    abstract::We analyze experimentally and theoretically the sound propagation velocity of P-waves in granular media made of micrometer-size magnetite particles under an external magnetic field. The sound velocity is measured in a coherent (long-wavelength) regime of propagation after a controlled sample preparation consisting of ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.07.021

    authors: Botello FR,Quintanilla MAS,Castellanos A,Grekova EF,Tournat V

    更新日期:2018-01-01 00:00:00

  • Microbubble-enhanced hemorrhage control using high intensity focused ultrasound.

    abstract::Our objective was to investigate whether hemorrhage control can be achieved faster when high-intensity focused ultrasound (HIFU) is applied in the presence of ultrasound contrast agents (UCA) as compared to HIFU only application. Incisions (3 cm long and 0.5 cm deep) were produced in the livers of anesthetized rabbits...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.018

    authors: Zderic V,Brayman AA,Sharar SR,Crum LA,Vaezy S

    更新日期:2006-12-01 00:00:00

  • Acoustic source localization in a highly anisotropic plate with unknown orientation of its axes of symmetry and material properties with numerical verification.

    abstract::Development of acoustic source localization techniques in anisotropic plates has gained attention in the recent past and still has scope of improvement. Most of such techniques existing in the literature either require known material properties or assume a straight line propagation of wave energy from the acoustic sou...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105977

    authors: Sen N,Kundu T

    更新日期:2020-01-01 00:00:00

  • Effect of lay-up of sub-waveguide on transmission of S(o) mode from main waveguide to sub-waveguides.

    abstract::This paper focuses on transmission characteristics of fundamental symmetric Lamb mode (So) at the junction of a main waveguide and sub-waveguides in composite laminates. Numerical simulations on transmission of So from the main to sub-waveguide revealed that transmission factors of the modes depend on stacking sequenc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.08.003

    authors: Ramadas C

    更新日期:2016-01-01 00:00:00

  • An improved Richardson-Lucy iterative algorithm for C-scan image restoration and inclusion size measurement.

    abstract::The accuracy of measuring inclusion size in direct C-scan image of immersion ultrasonic testing is restricted by the lateral resolution of the focused transducer, even if a high frequency is used, and the blurred edge due to scattering of sound waves at inclusions. In this work, an improved image restoration method th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.07.021

    authors: Chen D,Xiao H,Xu J

    更新日期:2019-01-01 00:00:00