A comparative analysis of multi-pulse techniques in contrast-enhanced ultrasound medical imaging.

Abstract:

:One of the important issues in the field of ultrasound medical imaging using contrast agents is the development of techniques able to separate the response of the contrast media from that of the biological tissues. In the literature, one can find various solutions involving the use of multiple transmitted signals and the combination of related echoes. However, the quality of these techniques may be reduced due to some undesired effects that are seldom considered, despite the fact that they are always present in real systems. These effects are the signal distortions introduced by the hardware equipment, the thermal noise in the electronic circuitry, and body motion between successive pulses. In this paper we propose a simulation tool that will allow the calculation of the backscattered echo from a population of contrast agents immersed in a biological tissue, considering all the mentioned effects. With this tool, an assessment of the comparative robustness of three well-known multi-pulse techniques has been carried out under realistic working conditions and the performance of the three techniques has been evaluated in terms of contrast-to-tissue ratio and signal-to-noise ratio. The results show that the undesired effects have a strong impact on these techniques and that there are notable differences in their robustness. Finally, some suggestions on the choice of the particular technique to be applied are provided on the basis of the specific work conditions.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Crocco M,Palmese M,Sciallero C,Trucco A

doi

10.1016/j.ultras.2008.05.008

subject

Has Abstract

pub_date

2009-01-01 00:00:00

pages

120-5

issue

1

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(08)00115-7

journal_volume

49

pub_type

杂志文章
  • Long-path measurements of ultrasonic attenuation and velocity for very dilute slurries and liquids and detection of contaminates.

    abstract::The objective was to use multiple paths through the slurry to determine the lowest concentration that provided accurate attenuation measurements and to measure the velocity of sound through an effective long path. Ultrasonic attenuation measurements were obtained for slurries of silica (10 microm diameter) in water fo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.024

    authors: Greenwood MS,Adamson JD,Bamberger JA

    更新日期:2006-12-22 00:00:00

  • Spatiotemporal mapping of surface acoustic waves in isotropic and anisotropic materials.

    abstract::We demonstrate a new method for a real-time imaging of surface acoustic waves at frequencies up to 1 GHz with picosecond temporal and micron spatial resolutions using an ultrafast optical pump and probe technique combined with a common path interferometer. Using samples with isotropic or anisotropic substrates coated ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00090-2

    authors: Sugawara Y,Wright OB,Matsuda O,Gusev VE

    更新日期:2002-05-01 00:00:00

  • Thallium bromide iodide crystal acoustic anisotropy examination.

    abstract::Thallium bromide iodide crystal also known as KRS-5 is the well known material used in far infrared radiation applications for optical windows and lenses fabrication. The main advantage of this material is the transparency in wide band of wavelengths from 0.53 to 50μm. Despite such advantages as transparency and large...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.019

    authors: Mantsevich SN

    更新日期:2017-03-01 00:00:00

  • Simulation of electromechanical coupling coefficient by modified modal frequency spectrum method including the electrode effect

    abstract::An approximate formula has been developed to determine the electromechanical coupling coefficient of the piezoelectric film in a four-layer composite resonator, which includes two electrodes. In this formula, the coupling coefficient can be calculated from the distribution of the effective coupling coefficients, k2eff...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00172-9

    authors: Zhang Y,Wang Z,Cheeke JD

    更新日期:2000-03-01 00:00:00

  • Development of SH-SAW sensors for underwater measurement.

    abstract::We developed SH (shear horizontal) surface acoustic wave (SAW) sensors to detect protein molecules in liquid solutions applying a particular antibody thin film on the delay line of transverse SAW devices. The antibody investigated was human-immuno-globulin G (HigG) to hold the antigens (anti-HigG) in the protein solut...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.039

    authors: Kwon Y,Roh Y

    更新日期:2004-04-01 00:00:00

  • Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels.

    abstract::Experimental studies of thermal effects in high-intensity focused ultrasound (HIFU) procedures are often performed with the aid of fine wire thermocouples positioned within tissue phantoms. Thermocouple measurements are subject to several types of error which must be accounted for before reliable inferences can be mad...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.07.007

    authors: Dasgupta S,Banerjee RK,Hariharan P,Myers MR

    更新日期:2011-02-01 00:00:00

  • Analysis of multiple wavelengths of Lamb waves generated by meander-line coil EMATs.

    abstract::The electromagnetic acoustic transducers (EMATs) with a meander-line coil possess the capability of generating Lamb waves carrying multiple wavelengths, and the characteristics of multiple wavelengths is analyzed by developing a spatial transversal filter model for the EMAT. It is shown that the characteristics is due...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.003

    authors: Zhai G,Jiang T,Kang L

    更新日期:2014-02-01 00:00:00

  • Transverse (lateral) instantaneous force of an acoustical first-order Bessel vortex beam centered on a rigid sphere.

    abstract::In a recent report [F.G. Mitri, Z.E.A. Fellah, Ultrasonics 51 (2011) 719-724], it has been found that the instantaneous axial force (i.e. acting along the axis of wave propagation) of a Bessel acoustic beam centered on a sphere is only determined for the fundamental order (i.e. m=0) but vanishes when the beam is of vo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.07.009

    authors: Mitri FG,Fellah ZE

    更新日期:2012-01-01 00:00:00

  • A derivation of the Christoffel equation with damping.

    abstract::This paper provides a derivation of the Christoffel eigenvalue equation for acoustic wave propagation in an acoustically damped piezoelectric medium. The damping tensor is shown to couple into both the stress and displacement constitutive equations. Application of the quasi-static approximation leads to an additional ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.005

    authors: Shane Fazzio R

    更新日期:2006-12-01 00:00:00

  • Effect of spatial dispersion on transient acoustic wave propagation in 3D.

    abstract::Spatial dispersion is the variation of wave speed with wavelength. It sets in when the acoustic wavelength approaches the natural scale of length of the medium, which could, for example, be the lattice constant of a crystal, the repeat distance in a superlattice, or the grain size in a granular material. In centrosymm...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.215

    authors: Every AG

    更新日期:2006-12-22 00:00:00

  • The nonlinear S0 Lamb mode in a plate with a linearly-varying thickness.

    abstract::The aim of this paper is to investigate propagation characteristics and the generation mechanism of the nonlinear lowest-order symmetric Lamb mode (S0) which propagates downslope in free elastic plates with slowly linearly varying-thickness. From theoretical analyses, in a low frequency-thickness product (fd) range, t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.11.013

    authors: Hu Z,An Z,Kong Y,Lian G,Wang X

    更新日期:2019-04-01 00:00:00

  • 100 MHz bandwidth planar laser-generated ultrasound source for hydrophone calibration.

    abstract::High-frequency calibration of hydrophones is becoming increasingly important, both for clinical and scientific applications of ultrasound, and user safety. At present, the calibrations available routinely to the user community extend to 60 MHz. However, hydrophones that can measure beyond this are available, and ultra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106218

    authors: Rajagopal S,Cox BT

    更新日期:2020-12-01 00:00:00

  • Comparison of two methods of treatment for intraluminal thermal ablation using an ultrasound cylindrical phased array.

    abstract::Intraluminal (within the alimentary tract) thermal surgery has been shown to be a useful therapeutic option when extracorporeal focused ultrasound applicators cannot be used since their beam may not reach the target site. If plane transducers are used for the treatment of alimentary tract tumours, the applicator must ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.088

    authors: Melodelima D,Prat F,Birer A,Theillère Y,Cathignol D

    更新日期:2004-04-01 00:00:00

  • Imaging microbubbles and tissues using a linear focussed scanner operating at 20 MHz: possible implications for the detection of cavitation thresholds.

    abstract::B-Scan images have been used as a means of detecting the onset of cavitation in tissues. New echoes appearing during simultaneous sonication with therapeutic ultrasound have often been attributed to bubble formation. In this study temperature rises up to 15 degrees C W-1 cm2 in guinea pig leg (post-mortem) were found,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(91)90028-7

    authors: Watmough DJ,Davies HM,Quan KM,Wytch R,Williams AR

    更新日期:1991-07-01 00:00:00

  • Sound field separating on arbitrary surfaces enclosing a sound scatterer based on combined integral equations.

    abstract::To eliminate the limitations of the conventional sound field separation methods which are only applicable to regular surfaces, a sound field separation method based on combined integral equations is proposed to separate sound fields directly in the spatial domain. In virtue of the Helmholtz integral equations for the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.06.007

    authors: Fan Z,Mei D,Yang K,Chen Z

    更新日期:2014-12-01 00:00:00

  • A fast technique for hyper-echoic region separation from brain ultrasound images using patch based thresholding and cubic B-spline based contour smoothing.

    abstract::Ultrasound image guided brain surgery (UGBS) requires an automatic and fast image segmentation method. The level-set and active contour based algorithms have been found to be useful for obtaining topology-independent boundaries between different image regions. But slow convergence limits their use in online US image s...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106304

    authors: Chel H,Bora PK,Ramchiary KK

    更新日期:2021-03-01 00:00:00

  • Acoustic streaming in lithotripsy fields: preliminary observation using a particle image velocimetry method.

    abstract::This study considers the acoustic streaming in water produced by a lithotripsy pulse. Particle image velocimetry (PIV) method was employed to visualize the acoustic streaming produced by an electromagnetic shock wave generator using video images of the light scattering particles suspended in water. Visualized streamin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2005.09.004

    authors: Choi MJ,Doh DH,Hwang TG,Cho CH,Paeng DG,Rim GH,Coleman AJ

    更新日期:2006-02-01 00:00:00

  • The sensitivity of surface guided modes to the bond quality between a concrete block and a composite plate.

    abstract::Ultrasonic modes guided along the surface of a concrete block covered by a composite plate are investigated. First of all, the propagation phenomenon is studied by predicting the dispersion curves for various modes supposed to exist in this structure. Then, focus is made on a specific mode expected to be sensitive to ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.074

    authors: Castaings M,Hosten B,François D

    更新日期:2004-04-01 00:00:00

  • Investigating the absolute phase information in acoustic wave resonance scattering.

    abstract::The aim of this work is to investigate the absolute phase information in resonance acoustic scattering by spheres and cylinders and place this work in the broader context of scattering in which the properties of the magnitude and (processed) phase have been examined in a more general way than in the classical resonanc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.01.002

    authors: Mitri FG,Greenleaf JF,Fellah ZE,Fatemi M

    更新日期:2008-07-01 00:00:00

  • Therapeutic opportunities in biological responses of ultrasound.

    abstract::The therapeutic benefits of several existing ultrasound-based therapies such as facilitated drug delivery, tumor ablation and thrombolysis derive largely from physical or mechanical effects. In contrast, ultrasound can also trigger various time-dependent biochemical responses in the exposed biological milieu. Several ...

    journal_title:Ultrasonics

    pub_type: 杂志文章,评审

    doi:10.1016/j.ultras.2008.02.002

    authors: Paliwal S,Mitragotri S

    更新日期:2008-08-01 00:00:00

  • Modal analysis and moving performance of a single-mode linear ultrasonic motor.

    abstract::A single-mode linear ultrasonic motor was developed in this study. On the stator, a group of four pieces of piezoelectric ceramics PZT8 were utilized to generate the ultrasonic vibration. A specially designed modal conversion horn with an oblique beam was applied to transfer the longitudinal vibration to an additional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106216

    authors: Yin Z,Dai C,Cao Z,Li W,Chen Z,Li C

    更新日期:2020-12-01 00:00:00

  • Needle and seed segmentation in intra-operative 3D ultrasound-guided prostate brachytherapy.

    abstract::In order to guide the needle to the correct location in 3D US-guided brachytherapy, the needle is continuously tracked as it is being inserted. A pre-scan before the needle insertion and a post-scan after the needle insertion are subtracted to obtain a difference image containing the needle. The image is projected alo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.003

    authors: Ding M,Wei Z,Gardi L,Downey DB,Fenster A

    更新日期:2006-12-22 00:00:00

  • Nonlinear Coda Wave Interferometry: Sensitivity to wave-induced material property changes analyzed via numerical simulations in 2D.

    abstract::The numerical studies conducted in this paper are based on our previous research (Chen et al., 2017); through use of the spectral element method, parametric sensitivity studies of Nonlinear Coda Wave Interferometry (NCWI) are established here and divided into two parts. In the first part, CWI observables are found to ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105968

    authors: Chen G,Pageot D,Abraham O,Zhang Y,Chekroun M,Tournat V

    更新日期:2019-11-01 00:00:00

  • Development of an ultrasonic linear motor with ultra-positioning capability and four driving feet.

    abstract::This paper presents a novel linear piezoelectric motor which is suitable for rapid ultra-precision positioning. The finite element analysis (FEA) was applied for optimal design and further analysis, then experiments were conducted to investigate its performance. By changing the input signal, the proposed motor was fou...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.07.010

    authors: Zhu C,Chu X,Yuan S,Zhong Z,Zhao Y,Gao S

    更新日期:2016-12-01 00:00:00

  • Harmonic analysis of lossy, piezoelectric composite transducers using the plane wave expansion method.

    abstract::Periodic composite ultrasonic transducers offer many advantages but the periodic pillar architecture can give rise to unwanted modes of vibration which interfere with the piston like motion of the fundamental thickness mode. In this paper, viscoelastic loss is incorporated into a three-dimensional plane wave expansion...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.03.004

    authors: Orr LA,Mulholland AJ,O'Leary RL,Hayward G

    更新日期:2008-12-01 00:00:00

  • Limited damage of tissue mimic caused by a collapsing bubble under low-frequency ultrasound exposure.

    abstract::In this study, we investigated the bubble induced serious damage to tissue mimic exposed to 27-kHz ultrasound. The initial bubble radius ranged from 80 to 100 μm, which corresponded approximately to the experimentally-evaluated resonant radius of the given ultrasound frequency. The tissue mimic consisted of 10 wt% gel...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.011

    authors: Yoshida K,Obata K,Tsukamoto A,Ushida T,Watanabe Y

    更新日期:2014-08-01 00:00:00

  • Focused ultrasound phantom model for blood brain barrier disruption.

    abstract::In this paper a high intensity focused ultrasound (FUS) phantom model was developed, in order to be used in experiments for Blood Brain Barrier (BBB) disruption. The target was to create a phantom model that represents the disruption of the BBB during ultrasound application. An appropriate experimental setup was creat...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106244

    authors: Alekou T,Giannakou M,Damianou C

    更新日期:2021-02-01 00:00:00

  • Effect of lay-up of sub-waveguide on transmission of S(o) mode from main waveguide to sub-waveguides.

    abstract::This paper focuses on transmission characteristics of fundamental symmetric Lamb mode (So) at the junction of a main waveguide and sub-waveguides in composite laminates. Numerical simulations on transmission of So from the main to sub-waveguide revealed that transmission factors of the modes depend on stacking sequenc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.08.003

    authors: Ramadas C

    更新日期:2016-01-01 00:00:00

  • A prosthetic aid for a developing blind child.

    abstract::An experimental ultrasonic sonar for use as a sensory aid with blind children is described. Novel signal processing techniques make the aid relatively simple to construct, yet allow many of its parameters to be changed in the field. In particular, the aid has two features, a variable range code and an automatic level...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(79)90010-6

    authors: Boys JT,Strelow ER,Clark GR

    更新日期:1979-01-01 00:00:00

  • Torsional ultrasonic transducer computational design optimization.

    abstract::A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predomina...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.05.001

    authors: Melchor J,Rus G

    更新日期:2014-09-01 00:00:00