A prosthetic aid for a developing blind child.

Abstract:

:An experimental ultrasonic sonar for use as a sensory aid with blind children is described. Novel signal processing techniques make the aid relatively simple to construct, yet allow many of its parameters to be changed in the field. In particular, the aid has two features, a variable range code and an automatic level control, which make the device very versatile in a wide variety of environments. The ultrasonic tranducers used in the aid are described in some detail.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Boys JT,Strelow ER,Clark GR

doi

10.1016/0041-624x(79)90010-6

subject

Has Abstract

pub_date

1979-01-01 00:00:00

pages

37-42

issue

1

eissn

0041-624X

issn

1874-9968

pii

0041-624X(79)90010-6

journal_volume

17

pub_type

杂志文章
  • Thallium bromide iodide crystal acoustic anisotropy examination.

    abstract::Thallium bromide iodide crystal also known as KRS-5 is the well known material used in far infrared radiation applications for optical windows and lenses fabrication. The main advantage of this material is the transparency in wide band of wavelengths from 0.53 to 50μm. Despite such advantages as transparency and large...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.019

    authors: Mantsevich SN

    更新日期:2017-03-01 00:00:00

  • Phonophoresis: an in vivo evaluation using three topical anaesthetic preparations.

    abstract::An electrical sensory perception threshold technique has been developed for use with human volunteers. This technique has been used to reproducibly quantify the effects of three different commercially available topical anaesthetic preparations on superficial sensory cells (nociceptors) in the skin. Low intensities (0....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(90)90075-y

    authors: Williams AR

    更新日期:1990-05-01 00:00:00

  • Picosecond acoustics method for measuring the thermodynamical properties of solids and liquids at high pressure and high temperature.

    abstract::Based on the original combination of picosecond acoustics and diamond anvils cell, recent improvements to accurately measure hypersonic sound velocities of liquids and solids under extreme conditions are described. To illustrate the capability of this technique, results are given on the pressure and temperature depend...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.04.011

    authors: Decremps F,Gauthier M,Ayrinhac S,Bove L,Belliard L,Perrin B,Morand M,Le Marchand G,Bergame F,Philippe J

    更新日期:2015-02-01 00:00:00

  • State-of-the-art surface acoustic wave linear motor and its future applications

    abstract::Two merits of the surface acoustic wave (SAW) device are its high energy density and small size. However, the driving frequency is around 10 MHz or higher. In spite of the difficulties involved with high frequency, the high energy density is attractive for actuator applications. The SAW linear motor's no load speed an...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00087-6

    authors: Kurosawa MK

    更新日期:2000-03-01 00:00:00

  • Extended optical theorem for scalar monochromatic acoustical beams of arbitrary wavefront in cylindrical coordinates.

    abstract::One of the fundamental theorems in (optical, acoustical, quantum, gravitational) wave scattering is the optical theorem for plane waves, which relates the extinction cross-section to the forward scattering complex amplitude function. In this analysis, the optical theorem is extended for the case of 3D-beams of arbitra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.01.006

    authors: Mitri FG

    更新日期:2016-04-01 00:00:00

  • Amplitude degradation of time-reversed pulses in nonlinear absorbing thermoviscous fluids.

    abstract::The linear wave equation in a lossless medium is time reversible, i.e., every solution p(x, t) has a temporal mirror solution p(x, -t). Analysis shows that time reversal also holds for the lossless nonlinear wave equation. In both cases, time-reversal invariance is violated when losses are present. For nonlinear propa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00020-2

    authors: Hallaj IM,Cleveland R0,Barbone PE,Kargl SG,Roy RA

    更新日期:2000-09-01 00:00:00

  • Aperture and element minimization in linear sparse arrays with desired beam patterns

    abstract::In this paper, an optimization method aimed at designing aperiodic linear sparse arrays is proposed that is based on the stochastic optimization methodology called simulated annealing. Such a method optimizes the positions and the weight coefficients of each element of a linear array in order to obtain a beam pattern ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00089-x

    authors: Trucco A

    更新日期:2000-03-01 00:00:00

  • The sensitivity of surface guided modes to the bond quality between a concrete block and a composite plate.

    abstract::Ultrasonic modes guided along the surface of a concrete block covered by a composite plate are investigated. First of all, the propagation phenomenon is studied by predicting the dispersion curves for various modes supposed to exist in this structure. Then, focus is made on a specific mode expected to be sensitive to ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.074

    authors: Castaings M,Hosten B,François D

    更新日期:2004-04-01 00:00:00

  • Effect of lay-up of sub-waveguide on transmission of S(o) mode from main waveguide to sub-waveguides.

    abstract::This paper focuses on transmission characteristics of fundamental symmetric Lamb mode (So) at the junction of a main waveguide and sub-waveguides in composite laminates. Numerical simulations on transmission of So from the main to sub-waveguide revealed that transmission factors of the modes depend on stacking sequenc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.08.003

    authors: Ramadas C

    更新日期:2016-01-01 00:00:00

  • Microbubble-enhanced hemorrhage control using high intensity focused ultrasound.

    abstract::Our objective was to investigate whether hemorrhage control can be achieved faster when high-intensity focused ultrasound (HIFU) is applied in the presence of ultrasound contrast agents (UCA) as compared to HIFU only application. Incisions (3 cm long and 0.5 cm deep) were produced in the livers of anesthetized rabbits...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.018

    authors: Zderic V,Brayman AA,Sharar SR,Crum LA,Vaezy S

    更新日期:2006-12-01 00:00:00

  • Generation of microbubbles from hollow cylindrical ultrasonic horn.

    abstract::In this study, we found that microbubbles with diameters of less than 100μm can be easily generated by using a hollow cylindrical ultrasonic horn. Consecutive images of bubbles obtained by using high-speed and high-resolution cameras reveal that a capillary wave is formed on the gas-liquid interface under weak ultraso...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.010

    authors: Makuta T,Suzuki R,Nakao T

    更新日期:2013-01-01 00:00:00

  • The applicability of a material-treatment laser pulse in non-destructive evaluations.

    abstract::A practical optodynamic study was performed to determine the usability of different lengths of laser pulses for the generation of ultrasonic transients in a solid material. The aim of the study was to evaluate the possibility of a dual use for a laser pulse-for laser material processing, on the one hand, and for the u...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.071

    authors: Hrovatin R,Petkovsek R,Diaci J,Mozina J

    更新日期:2006-12-22 00:00:00

  • On the low vibration modes observed in a sphere submitted to a tangential contact force.

    abstract::In this paper we discuss the existence of translational and rotational displacements of a sphere submitted to a tangential contact force. On the basis of the Bogdanov and Skvortsov's works [A.N. Bogdanov, A.T. Skvortsov, Sov. Phys. Acoust. 38 (1992) 224-226.] the dispersion equation has been established and solved for...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.019

    authors: De Billy M

    更新日期:2006-12-01 00:00:00

  • Quantitative colour-ultrasonography by means of a computer aided simultaneous tomogram.

    abstract::In this newly developed method, the ultrasonic diagnosis has become quantitative. The data will remain quantitative so far as an image storage tube is used. With the conventional storage type CRT, it is impossible to memorize the reflected echo signals of different strength levels. But with our method, it becomes poss...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(75)90036-0

    authors: Yokoi H,Tatsumi T,Ito K

    更新日期:1975-09-01 00:00:00

  • Impact of localized inhomogeneity on the surface-wave velocity and bulk-wave reflection in solids.

    abstract::The effect of a weak surface, near-surface and interfacial inhomogeneity on the frequency dependence of the surface wave velocity and of the SH (shear horizontal) wave reflectivity in isotropic elastic media is studied analytically and numerically. The inhomogeneity is modeled as an infinite planar layer with continuo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.001

    authors: Baron C,Shuvalov AL,Poncelet O

    更新日期:2007-03-01 00:00:00

  • Architectures for ultrasonic planetary sample retrieval tools.

    abstract::Traditional rotary corers and sample retrieval mechanisms for planetary drilling suffer from a variety of technical difficulties. A heavy and rigid drillstring must be assembled on-site and deployed with considerable applied preload and torque, and these mechanical loadings are difficult to react in a low gravity envi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.06.001

    authors: Harkness P,Lucas M,Cardoni A

    更新日期:2011-12-01 00:00:00

  • The performance and design of ultrasonic vibration system for flexural mode.

    abstract::The matrix method for analyzing flexural vibration system is outlined. The displacement, stress and velocity gain of ultrasonic flexural vibration systems are investigated by transfer matrix method. A design method is given for flexural transducer and vibration system. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00034-2

    authors: Zhou G

    更新日期:2000-11-01 00:00:00

  • Absence of biological damage from prolonged exposure to intravascular ultrasound: a swine model.

    abstract::Ultrasound (US) has been used in IMS II (intravascular US) and CLOTBUST (transcranial US) clinical trials for thrombolysis. During the treatment, in addition to the targeted thrombus, other biological components, such as blood and vessel walls are subjected to long durations of US exposure. In this study we explored e...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.10.004

    authors: Soltani A,Singhal R,Garcia JL,Raju NR

    更新日期:2007-03-01 00:00:00

  • Development of an ultra-portable echo device connected to USB port.

    abstract::In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.11.009

    authors: Saijo Y,Nitta S,Kobayashi K,Arai H,Nemoto Y

    更新日期:2004-04-01 00:00:00

  • Effect of the microstructure on the propagation velocity of ultrasound in magnetic powders.

    abstract::We analyze experimentally and theoretically the sound propagation velocity of P-waves in granular media made of micrometer-size magnetite particles under an external magnetic field. The sound velocity is measured in a coherent (long-wavelength) regime of propagation after a controlled sample preparation consisting of ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.07.021

    authors: Botello FR,Quintanilla MAS,Castellanos A,Grekova EF,Tournat V

    更新日期:2018-01-01 00:00:00

  • Visualization of the interaction of guided acoustic waves with water by light refractive vibrometry.

    abstract::Guided acoustic waves, such as Lamb waves, are widely applied for material characterization, sensing of liquids and the generation of streaming in liquids. There are numerical simulation tools for the prediction of their propagation near a solid-liquid boundary but a demand for complementary measurement techniques for...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105955

    authors: Tietze S,Lindner G

    更新日期:2019-11-01 00:00:00

  • Modeling electrical response of polymer-coated SAW resonators by equivalent circuit representation.

    abstract::The paper presents an equivalent circuit model of the polymer coated surface acoustic wave (SAW) resonators by combining coupling-of-mode (COM) description of SAW resonators and perturbation calculation of SAW propagation under polymer loading. An expression for the motional load produced by polymer coating is deduced...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.12.006

    authors: Kshetrimayum R,Yadava RD,Tandon RP

    更新日期:2011-07-01 00:00:00

  • Generalised bisection method for optimum ultrasonic ray tracing and focusing in multi-layered structures.

    abstract::Ultrasonic testing has been used for many decades, proving itself very efficient for detecting defects in many industrial sectors. The desire to apply ultrasonic testing to geometrically complex structures, and to anisotropic, inhomogeneous materials, together with the advent of more powerful electronics and software,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106330

    authors: Mineo C,Lines D,Cerniglia D

    更新日期:2021-03-01 00:00:00

  • Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600 by means of array probes.

    abstract::Ultrasonic non-destructive testing of polycrystalline structures can be disturbed by scattering at grain boundaries. Understanding and modeling this so-called "structural noise" is crucial for characterization as well as detection purposes. Structural noise can be considered as a fingerprint of the material under inve...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.06.012

    authors: Shahjahan S,Rupin F,Aubry A,Chassignole B,Fouquet T,Derode A

    更新日期:2014-01-01 00:00:00

  • Experimental study of the influence of different resonators on thermoacoustic conversion performance of a thermoacoustic-Stirling heat engine.

    abstract::In this paper, an experimental study of the effect of the resonator shape on the performance of a traveling-wave thermoacoustic engine is presented. Two different resonators were tested in the thermoacoustic-Stirling heat. One resonator is an iso-diameter one, and the other is a tapered one. To have a reasonable compa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.08.008

    authors: Luo EC,Ling H,Dai W,Yu GY

    更新日期:2006-12-22 00:00:00

  • Visualization of surface acoustic wave scattering by dislocations.

    abstract::Stroboscopic X-ray topography at the synchrotron beam line was used to visualize the propagation of a 580 MHz surface acoustic waves (SAW) in LiNbO3 crystals. For this purpose, the X-ray bursts coming from the synchrotron storage ring with periodicity of 5.68 MHz were synchronized with the SAW frequency in a phase-loc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00232-9

    authors: Shilo D,Zolotoyabko E

    更新日期:2002-05-01 00:00:00

  • High accuracy non-contact ultrasonic thickness gauging of aluminium sheet using electromagnetic acoustic transducers.

    abstract::Aluminium sheet thickness has been calculated from ultrasonic data obtained using a send-receive, radially polarised electromagnetic acoustic transducer (EMAT). Sheets in the thickness range between 0.1 and 0.5 mm have been measured using this non-contact approach at a stand-off of up to 1.5 mm. Normal incidence shear...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(01)00083-x

    authors: Dixon S,Edwards C,Palmer SB

    更新日期:2001-10-01 00:00:00

  • New nonlinear ultrasonic method for material characterization: Codirectional shear horizontal guided wave mixing in plate.

    abstract::A nonlinear ultrasonic method is proposed based on a group of newly discovered wave triplets where two primary codirectional shear-horizontal SH0 waves mix in a weakly nonlinear plate and generate a cumulative S0 Lamb wave at the sum frequency. Theoretical analyses show that any combination of two primary SH0 waves wh...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.04.001

    authors: Shan S,Hasanian M,Cho H,Lissenden CJ,Cheng L

    更新日期:2019-07-01 00:00:00

  • Health monitoring of a composite wingbox structure.

    abstract::This work was devoted to the development of a health monitoring system assigned to aerospace applications. Those applications concerned the detection of damaging impacts and debonding between stiffeners and composite skins, since they are the major causes of in-service damage of aircraft structures. The chosen health ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.058

    authors: Grondel S,Assaad J,Delebarre C,Moulin E

    更新日期:2004-04-01 00:00:00

  • Propagation of thickness shear waves in a periodically corrugated quartz crystal plate and its application exploration in acoustic wave filters.

    abstract::The propagation of thickness shear waves in a periodically corrugated quartz crystal plate is investigated in the present paper using a power series expansion technique. In the proposed simulation model, an equivalent continuity of shear stress moment is introduced as an approximation to handle sectional interfaces wi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.004

    authors: Li P,Cheng L

    更新日期:2017-05-01 00:00:00