Experimental study of the influence of different resonators on thermoacoustic conversion performance of a thermoacoustic-Stirling heat engine.

Abstract:

:In this paper, an experimental study of the effect of the resonator shape on the performance of a traveling-wave thermoacoustic engine is presented. Two different resonators were tested in the thermoacoustic-Stirling heat. One resonator is an iso-diameter one, and the other is a tapered one. To have a reasonable comparison reference, we keep the same traveling-wave loop, the same resonant frequency and the same operating pressure. The experiment showed that the resonator shape has significant influence on the global performance of the thermoacoustic-Stirling heat engine. The tapered resonator gives much better performance than the iso-diameter resonator. The tapered resonator system achieved a maximum pressure ratio of about 1.3, a maximum net acoustical power output of about 450 W and a highest thermoacoustic efficiency of about 25%.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Luo EC,Ling H,Dai W,Yu GY

doi

10.1016/j.ultras.2006.08.008

subject

Has Abstract

pub_date

2006-12-22 00:00:00

pages

e1507-9

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(06)00352-0

journal_volume

44 Suppl 1

pub_type

杂志文章
  • Dynamic interrogator for elastic wave sensing using Fabry Perot filters based on fiber Bragg gratings.

    abstract::Use of in-fiber Fabry-Perot (FP) filters based on fiber Bragg gratings as both sensor as well as an interrogator for enhancing the detection limit of elastic wave sensing is investigated in this paper. The sensitivity of such a demodulation scheme depends on the spectral discrimination of the sensor and interrogator g...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.02.018

    authors: Harish AV,Varghese B,Rao B,Balasubramaniam K,Srinivasan B

    更新日期:2015-07-01 00:00:00

  • Sensitivity of a miniaturized touch probe sensor using PZT thin film vibrator.

    abstract::In this paper, an improved touch probe sensor device for higher sensitivity and low contact force is reported. In order to improve the resolution, we have evaluated the sensitivity and fabricated a miniaturized sensor. The sensor transducer was 3 mm long and had higher resonance frequency. The resonance frequency of t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00091-4

    authors: Kanda T,Kurosawa MK,Higuchi T

    更新日期:2002-05-01 00:00:00

  • Investigating ultrasound-induced acoustic softening in aluminum and its alloys.

    abstract::Ultrasonic vibration has been observed to lower the flow stress necessary to initiate plastic deformation, a phenomenon known as "acoustic softening". This unique effect of ultrasound has been extensively applied in welding, machining, forming of metals, and ultrasonic additive manufacturing to lower the yield stress ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.106005

    authors: Mao Q,Coutris N,Rack H,Fadel G,Gibert J

    更新日期:2020-03-01 00:00:00

  • Nonlinear surface acoustic waves: realization of solitary pulses and fracture.

    abstract::A laser-based technique for the contact-free generation and detection of strongly nonlinear surface acoustic wave (SAW) pulses with amplitudes limited by the materials strength has been developed. The effects of nonlinear propagation of short elastic surface pulses with finite strength in isotropic solids, such as fus...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.06.002

    authors: Lomonosov AM,Hess P

    更新日期:2008-11-01 00:00:00

  • Stiffness evaluation of contacting surfaces by bulk and interface waves.

    abstract::This paper describes ultrasonic measurements of normal and tangential stiffnesses of the contacting interface between polished aluminum blocks subjected to nominal contact pressures up to about 3.8 MPa. These stiffnesses were evaluated by ultrasonic spectroscopy methods for the bulk (longitudinal and transverse) wave ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.08.005

    authors: Biwa S,Hiraiwa S,Matsumoto E

    更新日期:2007-12-01 00:00:00

  • The design of a high power ultrasonic test cell using finite element modelling techniques.

    abstract::This paper will describe the application of a finite element (FE) code to design a test cell, in which a single transducer is used to generate acoustic cavitation. The FE model comprises a 2-D slice through the centre of the test cell and was used to evaluate the generated pressure fields as a function of frequency. I...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00453-5

    authors: Gachagan A,Speirs D,McNab A

    更新日期:2003-06-01 00:00:00

  • Design of ultrasonic wedge transducer.

    abstract::Cones and wedges inserted between an ultrasonic transducer and the specimen provide the transducer (circular or rectangular shape) with enhanced capability for point or line contact with the specimen. Such an arrangement is useful in that the transducer can be used for transmitting to and receiving from a point (or li...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.10.002

    authors: Rus G,Wooh SC,Gallego R

    更新日期:2005-03-01 00:00:00

  • On the stability of wideband beam patterns with respect to weighting and envelope fluctuations.

    abstract::This paper presents a study on the worsening caused by a random perturbation of the weighting window (modeling, in this way, the uncertainty on the channel sensitivity), or by an alteration of the shape of the transmitted pulse, for a wideband array. In the stability evaluation, main-lobe width and signal to noise rat...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.006

    authors: Curletto S,Parodi C,Trucco A

    更新日期:2004-04-01 00:00:00

  • Subarray coherence based postfilter for eigenspace based minimum variance beamformer in ultrasound plane-wave imaging.

    abstract::This paper introduces a new beamformer, which combines the eigenspace based minimum variance (ESBMV) beamformer with a subarray coherence based postfilter (SCBP), for improving the quality of ultrasound plane-wave imaging. The ESBMV beamformer has been validated in improving the imaging contrast, but the difficulty in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.10.026

    authors: Zhao J,Wang Y,Yu J,Guo W,Li T,Zheng YP

    更新日期:2016-02-01 00:00:00

  • Microbubble-enhanced hemorrhage control using high intensity focused ultrasound.

    abstract::Our objective was to investigate whether hemorrhage control can be achieved faster when high-intensity focused ultrasound (HIFU) is applied in the presence of ultrasound contrast agents (UCA) as compared to HIFU only application. Incisions (3 cm long and 0.5 cm deep) were produced in the livers of anesthetized rabbits...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.018

    authors: Zderic V,Brayman AA,Sharar SR,Crum LA,Vaezy S

    更新日期:2006-12-01 00:00:00

  • Quantification of elasticity changes in the myometrium during labor using Supersonic Shear Imaging: a feasibility study.

    abstract::Very little is known about the myometrium's physiology in terms of its elasticity but shear wave elastography could be an efficient tool to better understand it. This could considerably help the prevention of difficult births, the consequences of which are tremendous for neonate morbidity and pathologies. The purpose ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.07.013

    authors: Gennisson JL,Muller M,Gabor P,Frydman R,Musset D,Tanter M,Ami O

    更新日期:2015-02-01 00:00:00

  • Thickness-shear vibration of a quartz plate connected to piezoelectric plates and electric field sensing.

    abstract::We study thickness-shear vibration of a quartz plate connected to two piezoelectric ceramic plates with initial deformations caused by a biasing electric field. The theory for small deformations superposed on finite biasing deformations in an electroelastic body is used. It is shown that the resonant frequencies of th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.07.002

    authors: Zhou Y,Chen W,Yang J,Du J

    更新日期:2011-02-01 00:00:00

  • Elastic guided wave propagation in a periodic array of multi-layered piezoelectric plates with finite cross-sections.

    abstract::In this study, we present a model study of guided wave dispersion and resonance behavior of an array of piezoelectric plates with arbitrary cross-sections. The objective of this work is to analyze the influence of the geometry of an element of a 1D-array ultrasound transducer on generating multi-resonance frequency so...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.08.006

    authors: Cortes DH,Datta SK,Mukdadi OM

    更新日期:2010-03-01 00:00:00

  • Spatial-temporal three-dimensional ultrasound plane-by-plane active cavitation mapping for high-intensity focused ultrasound in free field and pulsatile flow.

    abstract::Cavitation plays important roles in almost all high-intensity focused ultrasound (HIFU) applications. However, current two-dimensional (2D) cavitation mapping could only provide cavitation activity in one plane. This study proposed a three-dimensional (3D) ultrasound plane-by-plane active cavitation mapping (3D-UPACM)...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.010

    authors: Ding T,Hu H,Bai C,Guo S,Yang M,Wang S,Wan M

    更新日期:2016-07-01 00:00:00

  • Adaptive filtering for reduction of speckle in ultrasonic pulse-echo images.

    abstract::Current medical ultrasonic scanning instrumentation permits the display of fine image detail (speckle) which does not transfer useful information but degrades the apparent low contrast resolution in the image. An adaptive two-dimensional filter has been developed which uses local features of image texture to recognize...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(86)90072-7

    authors: Bamber JC,Daft C

    更新日期:1986-01-01 00:00:00

  • Thin-disk piezoceramic ultrasonic motor. Part I: design and performance evaluation.

    abstract::The purpose of this study is to gain the knowledge and experience in the design of thin-disk piezoceramic-driving ultrasonic actuator dedicated. In this paper, the design and construction of an innovative ultrasonic actuator is developed as a stator, which is a composite structure consisting of piezoceramic (PZT) memb...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00128-8

    authors: Wen FL,Yen CY,Ouyang M

    更新日期:2003-08-01 00:00:00

  • Micro-scale finite element modeling of ultrasound propagation in aluminum trabecular bone-mimicking phantoms: A comparison between numerical simulation and experimental results.

    abstract::The present study investigated the accuracy of micro-scale finite element modeling for simulating broadband ultrasound propagation in water-saturated trabecular bone-mimicking phantoms. To this end, five commercially manufactured aluminum foam samples as trabecular bone-mimicking phantoms were utilized for ultrasonic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.01.014

    authors: Vafaeian B,Le LH,Tran TN,El-Rich M,El-Bialy T,Adeeb S

    更新日期:2016-05-01 00:00:00

  • Tissue characterization of arteries with 4 MHz ultrasound.

    abstract::Reflections of 4 MHz ultrasound pulses from 60 sites on 15 human aorta specimens were analysed using the plane-wave Born approximation (PWBA) inverse scattering method. The recovered high-resolution acoustic impedance profile for each site was correlated with an analysis (by microscope) of sections taken from that sit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(95)00025-x

    authors: Tobocman W,Santosh K,Carter JR,Haacke EM

    更新日期:1995-07-01 00:00:00

  • Some studies on evaluation of degradation in composite adhesive joints using ultrasonic techniques.

    abstract::Experimental and theoretical studies on degradation of composite-epoxy adhesive joints were carried out on samples having different interfacial and cohesive properties. Oblique incidence ultrasonic inspection of bonded joints revealed that degradation in the adhesive can be measured by significant variation in reflect...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.01.014

    authors: Vijaya Kumar RL,Bhat MR,Murthy CR

    更新日期:2013-08-01 00:00:00

  • Nonlinear Coda Wave Interferometry: Sensitivity to wave-induced material property changes analyzed via numerical simulations in 2D.

    abstract::The numerical studies conducted in this paper are based on our previous research (Chen et al., 2017); through use of the spectral element method, parametric sensitivity studies of Nonlinear Coda Wave Interferometry (NCWI) are established here and divided into two parts. In the first part, CWI observables are found to ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105968

    authors: Chen G,Pageot D,Abraham O,Zhang Y,Chekroun M,Tournat V

    更新日期:2019-11-01 00:00:00

  • Imaging microbubbles and tissues using a linear focussed scanner operating at 20 MHz: possible implications for the detection of cavitation thresholds.

    abstract::B-Scan images have been used as a means of detecting the onset of cavitation in tissues. New echoes appearing during simultaneous sonication with therapeutic ultrasound have often been attributed to bubble formation. In this study temperature rises up to 15 degrees C W-1 cm2 in guinea pig leg (post-mortem) were found,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(91)90028-7

    authors: Watmough DJ,Davies HM,Quan KM,Wytch R,Williams AR

    更新日期:1991-07-01 00:00:00

  • Identification of material properties of orthotropic elastic cylinders immersed in fluid using vibroacoustic techniques.

    abstract::A numerical study is presented to show the potential for using vibroacoustic-based experiments to identify elastic material properties of orthotropic cylindrical vessels immersed in fluids. Sensitivity analyses and a simulated inverse problem are shown to quantify the potential for material characterization through th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.07.004

    authors: Rosario DE,Brigham JC,Aquino W

    更新日期:2008-11-01 00:00:00

  • Porosity estimation of concrete by ultrasonic NDE

    abstract::The increasing number of concrete structures with symptoms of premature deterioration due to environmental action demands procedures to estimate the durability of this type of component. Concrete durability is related to porosity, which determines the intensity of interactions of the material with aggressive agents. T...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00095-5

    authors: Hernandez MG,Izquierdo MA,Ibanez A,Anaya JJ,Ullate LG

    更新日期:2000-03-01 00:00:00

  • Axial vibration characteristics of a cylindrical, radially polarized piezoelectric transducer with different electrode patterns.

    abstract::A circular cylindrical piezoelectric transducer with radial polarization is proposed. The axial vibration characteristics of the transducer are studied by three different methods: analytical calculation, FEM simulation and experiment. The symmetric and asymmetric excitation conditions are discussed in the Haskins and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.008

    authors: Sun D,Wang S,Hata S,Shimokohbe A

    更新日期:2010-03-01 00:00:00

  • An improved Richardson-Lucy iterative algorithm for C-scan image restoration and inclusion size measurement.

    abstract::The accuracy of measuring inclusion size in direct C-scan image of immersion ultrasonic testing is restricted by the lateral resolution of the focused transducer, even if a high frequency is used, and the blurred edge due to scattering of sound waves at inclusions. In this work, an improved image restoration method th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.07.021

    authors: Chen D,Xiao H,Xu J

    更新日期:2019-01-01 00:00:00

  • Polymeric contrast agent with targeting potential.

    abstract::The Arg-Gly-Asp (RGD) peptide sequence was conjugated to poly (lactid acid), (PLA), microcapsules. These hollow, biodegradable PLGA microcapsules were developed in our laboratory for use as ultrasound contrast agents. By modifying the surface of the agent with a targeting ligand, it can be targeted to a specific addre...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.018

    authors: Lathia JD,Leodore L,Wheatley MA

    更新日期:2004-04-01 00:00:00

  • Annular phased array transducer for preclinical testing of anti-cancer drug efficacy on small animals.

    abstract::A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.12.008

    authors: Kujawska T,Secomski W,Byra M,Postema M,Nowicki A

    更新日期:2017-04-01 00:00:00

  • Spectral analysis of Doppler ultrasonic decompression data.

    abstract::Several aspects of spectral analysis of bubble transients in Doppler ultrasonic decompression data are discussed. The computation of energy density spectra, using fast Fourier transform techniques for analyzing bubble transients, is described. Spectral analysis of data from probes implanted within animals, using a con...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(77)90026-9

    authors: Kisman K

    更新日期:1977-05-01 00:00:00

  • Viability of plant cell suspensions exposed to homogeneous ultrasonic fields of different energy density and wave type.

    abstract::Exposure of Petunia hybrida cell suspensions to ultrasound at a frequency of 2.43 MHz in a standing wave field at an energy density of 70 Jm-3 (pressure amplitude of 0.78 MPa) decreased their mean viability to 35% after 20 min of sonication. A comparison of propagating wave and standing wave treatments at equal freque...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00166-3

    authors: Böhm H,Anthony P,Davey MR,Briarty LG,Power JB,Lowe KC,Benes E,Gröschl M

    更新日期:2000-03-01 00:00:00

  • Analysis of optodynamic sources generated during laser-induced breakdown in water.

    abstract::We propose a method for evaluating the size of the laser-induced breakdown region in water based on the detection and analysis of optodynamic waves. The breakdown region is an optodynamic source of pressure waves that propagate into the surrounding liquid as an ultrasonic pulse. In the experiment the optical breakdown...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.078

    authors: Petkovsek R,Horvat D,Mocnik G,Terzić M,Mozina J

    更新日期:2006-12-22 00:00:00