An improved Richardson-Lucy iterative algorithm for C-scan image restoration and inclusion size measurement.

Abstract:

:The accuracy of measuring inclusion size in direct C-scan image of immersion ultrasonic testing is restricted by the lateral resolution of the focused transducer, even if a high frequency is used, and the blurred edge due to scattering of sound waves at inclusions. In this work, an improved image restoration method that is based on the Richardson-Lucy (RL) iterative algorithm is proposed, which is used to restore the C-scan image and improve the accuracy of inclusion size measurement in immersion ultrasonic testing. For the improved RL iterative algorithm, the point spread function (PSF) is derived based on the multi-Gaussian beam model and Kirchhoff approximation, which considers the propagation properties of sound waves at water-steel interface and the spectral characteristics of the transducer with high frequency. In order to determine the final iteration number, the relationship between final iteration number and size of the inclusion in the image is established by restoring the simulated C-scan image and further calibrated with size correction factor. The size correction factor considers the effect of sound attenuation and electro-mechanical transformation encountered in practical testing equipment. Experimental results show that the inclusion sizes measured in restored C-scan images agree well with the optical micrograph results, which prove the effectiveness of the proposed method.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Chen D,Xiao H,Xu J

doi

10.1016/j.ultras.2018.07.021

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

103-113

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(17)30954-X

journal_volume

91

pub_type

杂志文章
  • Spatial-temporal three-dimensional ultrasound plane-by-plane active cavitation mapping for high-intensity focused ultrasound in free field and pulsatile flow.

    abstract::Cavitation plays important roles in almost all high-intensity focused ultrasound (HIFU) applications. However, current two-dimensional (2D) cavitation mapping could only provide cavitation activity in one plane. This study proposed a three-dimensional (3D) ultrasound plane-by-plane active cavitation mapping (3D-UPACM)...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.010

    authors: Ding T,Hu H,Bai C,Guo S,Yang M,Wang S,Wan M

    更新日期:2016-07-01 00:00:00

  • On the stability of wideband beam patterns with respect to weighting and envelope fluctuations.

    abstract::This paper presents a study on the worsening caused by a random perturbation of the weighting window (modeling, in this way, the uncertainty on the channel sensitivity), or by an alteration of the shape of the transmitted pulse, for a wideband array. In the stability evaluation, main-lobe width and signal to noise rat...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.006

    authors: Curletto S,Parodi C,Trucco A

    更新日期:2004-04-01 00:00:00

  • Guided waves in anisotropic and quasi-isotropic aerospace composites: three-dimensional simulation and experiment.

    abstract::Three-dimensional (3D) elastic wave simulations can be used to investigate and optimize nondestructive evaluation (NDE) and structural health monitoring (SHM) ultrasonic damage detection techniques for aerospace materials. 3D anisotropic elastodynamic finite integration technique (EFIT) has been implemented for ultras...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.05.007

    authors: Leckey CA,Rogge MD,Raymond Parker F

    更新日期:2014-01-01 00:00:00

  • Location of acoustic emission sources generated by air flow

    abstract::The location of continuous acoustic emission sources is a difficult problem of non-destructive testing. This article describes one-dimensional location of continuous acoustic emission sources by using an intelligent locator. The intelligent locator solves a location problem based on learning from examples. To verify w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00079-7

    authors: Kosel T,Grabec I I,Muzic P

    更新日期:2000-03-01 00:00:00

  • On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent.

    abstract::The goal standard of contrast echocardiography is the absolute measure of myocardial perfusion using a contrast agent. Actually, several contrast agents are developed. All these agents show left ventricular opacification after intravenous injection. However, none of these agents shows an acceptable enhancement of the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(97)00137-6

    authors: Bouakaz A,de Jong N,Cachard C,Jouini K

    更新日期:1998-02-01 00:00:00

  • A comparative analysis of multi-pulse techniques in contrast-enhanced ultrasound medical imaging.

    abstract::One of the important issues in the field of ultrasound medical imaging using contrast agents is the development of techniques able to separate the response of the contrast media from that of the biological tissues. In the literature, one can find various solutions involving the use of multiple transmitted signals and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.05.008

    authors: Crocco M,Palmese M,Sciallero C,Trucco A

    更新日期:2009-01-01 00:00:00

  • Effects of maximum aggregate size on UPV of brick aggregate concrete.

    abstract::Investigation was carried out to study the effects of maximum aggregate size (MAS) (12.5mm, 19.0mm, 25.0mm, 37.5mm, and 50.0mm) on ultrasonic pulse velocity (UPV) of concrete. For investigation, first class bricks were collected and broken to make coarse aggregate. The aggregates were tested for specific gravity, abso...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.006

    authors: Mohammed TU,Mahmood AH

    更新日期:2016-07-01 00:00:00

  • Tandem shock waves to enhance genetic transformation of Aspergillus niger.

    abstract::Filamentous fungi are used in several industries and in academia to produce antibiotics, metabolites, proteins and pharmaceutical compounds. The development of valuable strains usually requires the insertion of recombinant deoxyribonucleic acid; however, the protocols to transfer DNA to fungal cells are highly ineffic...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.003

    authors: Loske AM,Fernández F,Magaña-Ortíz D,Coconi-Linares N,Ortíz-Vázquez E,Gómez-Lim MA

    更新日期:2014-08-01 00:00:00

  • A reverse time migration-based multistep angular spectrum approach for ultrasonic imaging of specimens with irregular surfaces.

    abstract::We develop a new ultrasonic imaging framework for non-destructive testing of an immersed specimen featuring an irregular top surface and demonstrate its capability of accurately depicting the lower surfaces of multiple damages hidden in the specimen. Central to the framework is a multistep angular spectrum approach (A...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106233

    authors: Yang X,Wang K,Xu Y,Xu L,Hu W,Wang H,Su Z

    更新日期:2020-12-01 00:00:00

  • Finite element modeling of grain size effects on the ultrasonic microstructural noise backscattering in polycrystalline materials.

    abstract::The correlation between ultrasonic wave propagation and polycrystalline microstructures has significant implications in nondestructive evaluation. An original numerical approach using the finite element method to quantify in both time and frequency domains the ultrasonic noise scattering due to the elastic heterogenei...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.02.008

    authors: Bai X,Tie B,Schmitt JH,Aubry D

    更新日期:2018-07-01 00:00:00

  • Generation of transversal envelope soliton in polymeric and wooden rods.

    abstract::This paper is concerned with the probing of the transversal envelope solitons propagation in circular waveguides when a set of requirements (non-linearity and dispersion) are fulfilled in the waveguide and balanced. The basic idea is to analyze the shape of an acoustic pulse after it has traveled one or few trips thro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.01.016

    authors: de Billy M,Hladky-Hennion AC

    更新日期:2014-07-01 00:00:00

  • The dispersion and attenuation of the multi-physical fields coupled waves in a piezoelectric semiconductor.

    abstract::The dispersion and attenuation features of the multi-physical fields coupled waves propagating in an infinite piezoelectric semiconductor and the reflection problem at a boundary which is mechanically free, electrically insulation and the dielectrically open circuit are studied in this paper. Different from the classi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.09.009

    authors: Jiao F,Wei P,Zhou X,Zhou Y

    更新日期:2019-02-01 00:00:00

  • The quasi-harmonic ultrasonic polar scan for material characterization: experiment and numerical modeling.

    abstract::Conventionally, the ultrasonic polar scan (UPS) records the amplitude or time-of-flight in transmission using short ultrasonic pulses for a wide range of incidence angles, resulting in a fingerprint of the critical bulk wave angles of the material at the insonified spot. Here, we investigate the use of quasi-harmonic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.002

    authors: Kersemans M,Martens A,Van Den Abeele K,Degrieck J,Pyl L,Zastavnik F,Sol H,Van Paepegem W

    更新日期:2015-04-01 00:00:00

  • Simulation of ultrasonic and EMAT arrays using FEM and FDTD.

    abstract::This paper presents a method which combines electromagnetic simulation and ultrasonic simulation to build EMAT array models. For a specific sensor configuration, Lorentz forces are calculated using the finite element method (FEM), which then can feed through to ultrasonic simulations. The propagation of ultrasound wav...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.10.020

    authors: Xie Y,Yin W,Liu Z,Peyton A

    更新日期:2016-03-01 00:00:00

  • An ultrasonic array sensor for spacecraft leak direction finding.

    abstract::We have developed an ultrasonic array sensor useable for locating air leaks in manned spacecraft and have found that this sensor locates leaks in a 1-m(2) plate to within 2 cm. The sensor consists of a 63-element multiplexed array plus a reference element, all constructed from a single PZT disc and a printed circuit b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.020

    authors: Holland SD,Roberts R,Chimenti DE,Song JH

    更新日期:2006-12-01 00:00:00

  • Sensitivity to point-spread function parameters in medical ultrasound image deconvolution.

    abstract::Clinical ultrasound images are often perceived as difficult to interpret due to image blurring and speckle inherent in the ultrasound imaging. But the image quality can be improved by deconvolution using an estimate of the point-spread function. However, it is difficult to obtain a sufficiently accurate estimate of th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.005

    authors: Shin HC,Prager R,Ng J,Gomersall H,Kingsbury N,Treece G,Gee A

    更新日期:2009-03-01 00:00:00

  • Aperture and element minimization in linear sparse arrays with desired beam patterns

    abstract::In this paper, an optimization method aimed at designing aperiodic linear sparse arrays is proposed that is based on the stochastic optimization methodology called simulated annealing. Such a method optimizes the positions and the weight coefficients of each element of a linear array in order to obtain a beam pattern ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00089-x

    authors: Trucco A

    更新日期:2000-03-01 00:00:00

  • Peculiarities of energy trapping of the UHF elastic waves in diamond-based piezoelectric layered structure. II. Lateral energy flow.

    abstract::Features of an acoustic energy trapping and outflow in a High-overtone Bulk Acoustic Resonator (HBAR) were considered. On the example of a specified resonator based on a piezoelectric layered structure (PLS) as "Al/AlN/Mo/(100) diamond", the simulation of the propagation of microwave acoustic waves in the range of 10-...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106311

    authors: Kvashnin GM,Sorokin BP

    更新日期:2021-03-01 00:00:00

  • Inversion of synthetic and experimental acoustical scattering data for the comparison of two reconstruction methods employing the Born approximation.

    abstract::This work is concerned with the reconstruction, from measured (synthetic or real) data, of a 2D penetrable fluid-like object of arbitrary cross-section embedded in a fluid of infinite extent and insonified by a plane acoustic wave. Green's theorem is used to provide a domain integral representation of the scattered fi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00054-8

    authors: Guillermin R,Lasaygues P,Sessarego JP,Wirgin A

    更新日期:2001-03-01 00:00:00

  • Investigating the absolute phase information in acoustic wave resonance scattering.

    abstract::The aim of this work is to investigate the absolute phase information in resonance acoustic scattering by spheres and cylinders and place this work in the broader context of scattering in which the properties of the magnitude and (processed) phase have been examined in a more general way than in the classical resonanc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.01.002

    authors: Mitri FG,Greenleaf JF,Fellah ZE,Fatemi M

    更新日期:2008-07-01 00:00:00

  • Arbitrary shaped, liquid filled reverberators with non-resonant transducers for broadband focusing of ultrasound using Time Reversed Acoustics.

    abstract::The ability to generate short focused ultrasonic pulses with duration on the order of one period of carrier frequency depends on the bandwidth of the transmitter as the pulse duration is inversely proportional to the bandwidth. Conventional focusing arrays used for focusing ultrasound have limited bandwidth due to the...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.008

    authors: Sarvazyan A,Fillinger L

    更新日期:2009-03-01 00:00:00

  • Micromachined ultrasound transducers with improved coupling factors from a CMOS compatible process

    abstract::For medical high frequency acoustic imaging purposes the reduction in size of a single transducer element for one-dimensional and even more for two-dimensional arrays is more and more limited by fabrication and cabling technology. In the fields of industrial distance measurement and simple object recognition low cost ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00085-2

    authors: Eccardt PC,Niederer K

    更新日期:2000-03-01 00:00:00

  • Impact of localized inhomogeneity on the surface-wave velocity and bulk-wave reflection in solids.

    abstract::The effect of a weak surface, near-surface and interfacial inhomogeneity on the frequency dependence of the surface wave velocity and of the SH (shear horizontal) wave reflectivity in isotropic elastic media is studied analytically and numerically. The inhomogeneity is modeled as an infinite planar layer with continuo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.001

    authors: Baron C,Shuvalov AL,Poncelet O

    更新日期:2007-03-01 00:00:00

  • Detecting broken-wire flaws at multiple locations in the same wire of prestressing strands using guided waves.

    abstract::Broken wires often occur at multiple locations in the same wire of a strand due to the recovery length, which is defined as the length of the wire taking up its full share of the axial load from the break point. The detection of broken-wire flaws at multiple locations along the same wire is investigated using guided w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.003

    authors: Xu J,Wu X,Sun P

    更新日期:2013-01-01 00:00:00

  • New applications for ultrasonic sensors in process industries.

    abstract::Today, sophisticated instruments and algorithms used for process control allow the efficient production of substances with the quality guaranteed to the customer. However, production and management techniques are changing. This article aims to analyze trends resulting from those changes from the point of view of ultra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.047

    authors: Püttmer A

    更新日期:2006-12-22 00:00:00

  • Microbiological properties of poultry breast meat treated with high-intensity ultrasound.

    abstract::Lactic acid, psychrophilic, and mesophilic bacteria, Escherichia coli, Salmonella spp. and Staphylococcus aureus were enumerated on chicken breasts after treatment with different high intensity ultrasound (frequency 40 kHz, intensity 9.6 W/cm-2) application times (0, 30, and 50 min) and packaging atmospheres (aerobic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.01.001

    authors: Piñon MI,Alarcon-Rojo AD,Renteria AL,Carrillo-Lopez LM

    更新日期:2020-03-01 00:00:00

  • Research interface on a programmable ultrasound scanner.

    abstract:MOTIVATION:Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. OBJECTIVES:Recently, we developed a flexible ultrasound back-end where all th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.11.009

    authors: Shamdasani V,Bae U,Sikdar S,Yoo YM,Karadayi K,Managuli R,Kim Y

    更新日期:2008-07-01 00:00:00

  • Research on adaptive temperature control in sound field induced by self-focused concave spherical transducer.

    abstract::Temperature control of hyperthermia treatments is generally implemented with multipoint feedback system comprised of phased-array transducer, which is complicated and high cost. Our simulations to the acoustic field induced by a self-focused concave spherical transducer (0.5MHz, 9cm aperture width, 8.0cm focal length)...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.01.006

    authors: Hu J,Qian S,Ding Y

    更新日期:2010-05-01 00:00:00

  • Effect of wood properties on within-tree variation in ultrasonic wave velocity in softwood.

    abstract::The radial variations in the velocity of longitudinal waves propagating through Japanese cedar and Japanese cypress were experimentally investigated. In addition, the tracheid length (TL), microfibril angle (MFA), air-dried density (AD), and moisture content (MC) were measured in order to determine the effect of wood ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.10.001

    authors: Hasegawa M,Takata M,Matsumura J,Oda K

    更新日期:2011-04-01 00:00:00

  • Propagation of thickness shear waves in a periodically corrugated quartz crystal plate and its application exploration in acoustic wave filters.

    abstract::The propagation of thickness shear waves in a periodically corrugated quartz crystal plate is investigated in the present paper using a power series expansion technique. In the proposed simulation model, an equivalent continuity of shear stress moment is introduced as an approximation to handle sectional interfaces wi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.004

    authors: Li P,Cheng L

    更新日期:2017-05-01 00:00:00