Abstract:
:This paper presents a method which combines electromagnetic simulation and ultrasonic simulation to build EMAT array models. For a specific sensor configuration, Lorentz forces are calculated using the finite element method (FEM), which then can feed through to ultrasonic simulations. The propagation of ultrasound waves is numerically simulated using finite-difference time-domain (FDTD) method to describe their propagation within homogenous medium and their scattering phenomenon by cracks. Radiation pattern obtained with Hilbert transform on time domain waveforms is proposed to characterise the sensor in terms of its beam directivity and field distribution along the steering angle.
journal_name
Ultrasonicsjournal_title
Ultrasonicsauthors
Xie Y,Yin W,Liu Z,Peyton Adoi
10.1016/j.ultras.2015.10.020subject
Has Abstractpub_date
2016-03-01 00:00:00pages
154-165eissn
0041-624Xissn
1874-9968pii
S0041-624X(15)00275-9journal_volume
66pub_type
杂志文章相关文献
ULTRASONICS文献大全abstract::A laser-based technique for the contact-free generation and detection of strongly nonlinear surface acoustic wave (SAW) pulses with amplitudes limited by the materials strength has been developed. The effects of nonlinear propagation of short elastic surface pulses with finite strength in isotropic solids, such as fus...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.06.002
更新日期:2008-11-01 00:00:00
abstract::We develop a new ultrasonic imaging framework for non-destructive testing of an immersed specimen featuring an irregular top surface and demonstrate its capability of accurately depicting the lower surfaces of multiple damages hidden in the specimen. Central to the framework is a multistep angular spectrum approach (A...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106233
更新日期:2020-12-01 00:00:00
abstract::We have developed an ultrasonic array sensor useable for locating air leaks in manned spacecraft and have found that this sensor locates leaks in a 1-m(2) plate to within 2 cm. The sensor consists of a 63-element multiplexed array plus a reference element, all constructed from a single PZT disc and a printed circuit b...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.07.020
更新日期:2006-12-01 00:00:00
abstract::In this paper the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous materials is addressed. To determine the attenuation accurately over a wide frequency range, it is necessary to have suitable excitation techniques. Three kinds of transmitted signals have been analysed, grouped according t...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.09.007
更新日期:2016-02-01 00:00:00
abstract::Ultrasound evaluation permits the state of rocks to be determined quickly and cheaply, satisfying the demands faced by today's producers of ornamental stone, such as environmental sustainability, durability and safety of use. The basic objective of the present work is to analyse and develop the usefulness of ultrasoun...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.06.006
更新日期:2014-01-01 00:00:00
abstract::Based on the original combination of picosecond acoustics and diamond anvils cell, recent improvements to accurately measure hypersonic sound velocities of liquids and solids under extreme conditions are described. To illustrate the capability of this technique, results are given on the pressure and temperature depend...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.04.011
更新日期:2015-02-01 00:00:00
abstract::Two merits of the surface acoustic wave (SAW) device are its high energy density and small size. However, the driving frequency is around 10 MHz or higher. In spite of the difficulties involved with high frequency, the high energy density is attractive for actuator applications. The SAW linear motor's no load speed an...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(99)00087-6
更新日期:2000-03-01 00:00:00
abstract::An experimental ultrasonic sonar for use as a sensory aid with blind children is described. Novel signal processing techniques make the aid relatively simple to construct, yet allow many of its parameters to be changed in the field. In particular, the aid has two features, a variable range code and an automatic level...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(79)90010-6
更新日期:1979-01-01 00:00:00
abstract::We developed SH (shear horizontal) surface acoustic wave (SAW) sensors to detect protein molecules in liquid solutions applying a particular antibody thin film on the delay line of transverse SAW devices. The antibody investigated was human-immuno-globulin G (HigG) to hold the antigens (anti-HigG) in the protein solut...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.039
更新日期:2004-04-01 00:00:00
abstract::In the present paper, we report the first results concerning a centimetre cantilever driven through non-linear effects in thin magnetostrictive films. Bimorph centimetre beams (24 mm x 5 mm) were designed using 160 microns thick glass and 0.4 micron thick multilayer TbFe/Fe films deposited via RF sputtering, using sev...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(99)00061-x
更新日期:2000-03-01 00:00:00
abstract::High-frequency calibration of hydrophones is becoming increasingly important, both for clinical and scientific applications of ultrasound, and user safety. At present, the calibrations available routinely to the user community extend to 60 MHz. However, hydrophones that can measure beyond this are available, and ultra...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106218
更新日期:2020-12-01 00:00:00
abstract::Our objective was to investigate whether hemorrhage control can be achieved faster when high-intensity focused ultrasound (HIFU) is applied in the presence of ultrasound contrast agents (UCA) as compared to HIFU only application. Incisions (3 cm long and 0.5 cm deep) were produced in the livers of anesthetized rabbits...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.07.018
更新日期:2006-12-01 00:00:00
abstract::In this paper, we propose a semi-analytical isogeometric analysis(S-IGA) approach in the twist space to investigate the dispersive properties in helical thread waveguides, which combines the advantages of the spectral approach and IGA. The convergence and accuracy of the proposed method are discussed, by comparing S-I...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.06.004
更新日期:2018-02-01 00:00:00
abstract::It is now accepted that an effective way to investigate the elastic properties of soft tissues is to generate a localized transient acoustic radiation force and to follow the associated displacements in the time/space domain. Shear waves induced by this stress field are particularly interesting in this kind of medium ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.06.022
更新日期:2006-12-22 00:00:00
abstract:PURPOSE:Human 8-oxoguanine DNA glycosylase (OGG1) is a major base excision repair enzyme, and it was reported to suppress the activation of intrinsic apoptotic signaling pathway in response to oxidative stress. In this study, our aim was to investigate the effects of OGG1 downregulation on ultrasound-induced apoptosis ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.07.005
更新日期:2016-12-01 00:00:00
abstract::For coupled structures surrounded by heavy fluids, it is difficult to obtain dispersion curves from an eigenvalue analysis, because the external fluid term in the coupled equation includes transcendental functions for frequency and wavenumber. Thus, in this study, the acoustic mass of the external fluid was approximat...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.12.009
更新日期:2018-04-01 00:00:00
abstract::The radial variations in the velocity of longitudinal waves propagating through Japanese cedar and Japanese cypress were experimentally investigated. In addition, the tracheid length (TL), microfibril angle (MFA), air-dried density (AD), and moisture content (MC) were measured in order to determine the effect of wood ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.10.001
更新日期:2011-04-01 00:00:00
abstract::Periodic composite ultrasonic transducers offer many advantages but the periodic pillar architecture can give rise to unwanted modes of vibration which interfere with the piston like motion of the fundamental thickness mode. In this paper, viscoelastic loss is incorporated into a three-dimensional plane wave expansion...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.03.004
更新日期:2008-12-01 00:00:00
abstract::Lamb waves are being investigated extensively for structural health monitoring (SHM) because of their characteristics of traveling long distances with little attenuation and sensitivity to minor local damage in structures. However, Lamb waves are dispersive, which results in the complex overlap of waveforms in the dam...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2018.02.011
更新日期:2018-07-01 00:00:00
abstract::A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predomina...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.05.001
更新日期:2014-09-01 00:00:00
abstract::Human umbilical cords were exposed to high amplitude focussed ultrasonic pulses with focal energy densities 0.6 and 0.4 mJ mm-2. The endothelium of the exposed vessel (vein) was examined by means of confocal laser scanning microscopy and scanning electron microscopy. The degree of tissue change ranged from the inducti...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(94)90111-2
更新日期:1994-09-01 00:00:00
abstract::The characterization of brain tissue is crucial to better understand neurological disorders. Mechanical characterization is an emerging tool in that field. The purpose of this work was to validate a transient ultrasound technique aimed at measuring dispersion of mechanical parameters of the brain tissue. The first par...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.10.009
更新日期:2018-03-01 00:00:00
abstract::Ultrasonic techniques have been used to measure the elastic properties of bone. Eight human tibiae were used to determine and map the elastic properties of cortical and cancellous bone. The present study shows cortical bone to be at least orthotropic in its material symmetry. The mechanical properties of cortical bone...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(96)00078-9
更新日期:1996-12-01 00:00:00
abstract::A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.12.008
更新日期:2017-04-01 00:00:00
abstract::In general, the design and analysis of ultrasonic motor and motor's control strategy are based on mathematical model. The academic model is widely used in the analysis of traveling wave ultrasonic motor (TWUSM). But the dispersive characteristic of piezoelectric ceramics and other complicated process, such as the fric...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.09.012
更新日期:2014-02-01 00:00:00
abstract::We study thickness-shear vibration of a quartz plate connected to two piezoelectric ceramic plates with initial deformations caused by a biasing electric field. The theory for small deformations superposed on finite biasing deformations in an electroelastic body is used. It is shown that the resonant frequencies of th...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.07.002
更新日期:2011-02-01 00:00:00
abstract::A diagnostic ultrasound method is being developed for measuring surface contact areas at the tibio-femoral interface of a total knee replacement in a non-clinical industrial setting as an engineering design tool. As an initial step towards this, a previous study mathematically predicted the effect of ultrasound beam t...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00382-7
更新日期:2002-10-01 00:00:00
abstract::A cylindrical standing wave ultrasonic motor using bending vibration transducer was proposed in this paper. The proposed stator contains a cylinder and a bending vibration transducer. The two combining sites between the cylinder and the transducer locate at the adjacent wave loops of bending vibration of the transduce...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.12.007
更新日期:2011-07-01 00:00:00
abstract::Ultrasonic standing wave chambers with acoustic pathlengths of 1.1 and 0.62 mm have been constructed. The chambers were driven at frequencies over the range 0.66-12.2 MHz. The behaviour of 2 microns diameter latex microparticles and 5 microns diameter yeast in the chambers has been elucidated. One (flow) chamber had a...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(98)00019-5
更新日期:1998-08-01 00:00:00
abstract::The Synthetic Aperture Focusing (SAF) technique makes it possible to achieve a higher and more uniform quality of ultrasound images throughout depth, as if both transmit and receive dynamic focusing were applied. In this work we combine a particular implementation of SAF, called Synthetic Transmit Aperture (STA) techn...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.11.022
更新日期:2017-03-01 00:00:00