Suppression of human 8-oxoguanine DNA glycosylase (OGG1) augments ultrasound-induced apoptosis in cervical cancer cells.

Abstract:

PURPOSE:Human 8-oxoguanine DNA glycosylase (OGG1) is a major base excision repair enzyme, and it was reported to suppress the activation of intrinsic apoptotic signaling pathway in response to oxidative stress. In this study, our aim was to investigate the effects of OGG1 downregulation on ultrasound-induced apoptosis in cervical cancer cells. METHODS:OGG1 expression was silenced by shRNA in the cervical cancer SW756 and CaSki cells. Cell viability was evaluated by MTT assay after OGG1 knockdown following ultrasound treatment. Ultrasound-induced apoptosis was measured by Annexin V-FITC/propidium iodide. Intracellular reactive oxygen species (ROS) production and Ca(2+) concentration were detected using a fluorescent probe, 2',7'-dichlorofluorescin diacetate (DCFH-DA) and a green fluorescent dye fluo-4AM, respectively. Western blotting was used to analyze the expression of Bcl-2, Bax, cleaved caspase-3, and nuclear factor-κB p65 (NF-κB p65). RESULTS:The results indicated that OGG1 knockdown did not suppress cell proliferation, but significantly augmented ultrasound-induced inhibitory effects on the cell viability, and increased ultrasound-induced early apoptosis and late apoptosis and necrosis in the SW756 and CaSki cells when exposure to ultrasound (1MHz) at 1.5W/cm(2) for 30 and 60s. OGG1 knockdown significantly increased intracellular ROS production and Ca(2+) concentration after incubation of 6, 24, and 48h post-ultrasound treatment. The downregulation of Bcl-2 protein and the upregulation of Bax, cleaved caspase-3, and NF-κB p65 protein levels were observed in the shRNA-OGG1 cells and mock-shRNA cells, but no significant change of these protein levels was found between of them. CONCLUSIONS:These results indicate that downregulation of OGG1 expression can augment ultrasound-induced apoptosis in cervical cancer cells, which suggests that OGG1 suppression might provide a new insight for ultrasound-induced therapeutic effects on cervical cancer treatment.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Xu T,Nie Y,Bai J,Li L,Yang B,Zheng G,Zhang J,Yu J,Cheng X,Jiao J,Jing H

doi

10.1016/j.ultras.2016.07.005

subject

Has Abstract

pub_date

2016-12-01 00:00:00

pages

1-14

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(16)30111-1

journal_volume

72

pub_type

杂志文章
  • Fabrication and comparison of PMN-PT single crystal, PZT and PZT-based 1-3 composite ultrasonic transducers for NDE applications.

    abstract::This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acousti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.04.001

    authors: Kim KB,Hsu DK,Ahn B,Kim YG,Barnard DJ

    更新日期:2010-08-01 00:00:00

  • Ultrasonic strain imaging and reconstructive elastography for biological tissue.

    abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.007

    authors: Khaled W,Reichling S,Bruhns OT,Ermert H

    更新日期:2006-12-22 00:00:00

  • 1-60 MHz measurements in focused acoustic fields using spatial averaging corrections.

    abstract::The purpose of this research was to develop, implement and verify a measurement technique enabling rapid and dependable characterization of ultrasound hydrophone probes beyond 20 MHz. The technique employs focused acoustic sources to optimize signal-to-noise ratio and spatial averaging correction model to account for ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00166-x

    authors: Radulescu EG,Lewin PA,Nowicki A

    更新日期:2002-05-01 00:00:00

  • Amplitude degradation of time-reversed pulses in nonlinear absorbing thermoviscous fluids.

    abstract::The linear wave equation in a lossless medium is time reversible, i.e., every solution p(x, t) has a temporal mirror solution p(x, -t). Analysis shows that time reversal also holds for the lossless nonlinear wave equation. In both cases, time-reversal invariance is violated when losses are present. For nonlinear propa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00020-2

    authors: Hallaj IM,Cleveland R0,Barbone PE,Kargl SG,Roy RA

    更新日期:2000-09-01 00:00:00

  • Inversion of synthetic and experimental acoustical scattering data for the comparison of two reconstruction methods employing the Born approximation.

    abstract::This work is concerned with the reconstruction, from measured (synthetic or real) data, of a 2D penetrable fluid-like object of arbitrary cross-section embedded in a fluid of infinite extent and insonified by a plane acoustic wave. Green's theorem is used to provide a domain integral representation of the scattered fi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00054-8

    authors: Guillermin R,Lasaygues P,Sessarego JP,Wirgin A

    更新日期:2001-03-01 00:00:00

  • Multibubble sonoluminescence enhancement by fluid flow.

    abstract::Forced fluid flow can cause the enhancement of multibubble sonoluminescence (SL) under suitable conditions. The effect of directional flow with a circulator is similar to that of rotating flow with a stirrer. The mechanism of the enhancement is that both flows prevent cavitation bubbles from coalescing and clustering,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.022

    authors: Hatanaka S,Mitome H,Yasui K,Hayashi S

    更新日期:2006-12-22 00:00:00

  • Interior dynamics of subharmonious surface wave in an idealized bidimensional granular layer.

    abstract::In this paper, high-speed photography was used to investigate the intrinsic dynamics of subharmonious surface wave in a vertical vibrated and idealized bidimensional granular layer. Using the high-speed photography, velocity fields of the granular layer at different stages through two cycles were obtained, which show ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.196

    authors: Zhang P,Huang K,Miao G,Wei R

    更新日期:2006-12-22 00:00:00

  • Identification of material properties of orthotropic elastic cylinders immersed in fluid using vibroacoustic techniques.

    abstract::A numerical study is presented to show the potential for using vibroacoustic-based experiments to identify elastic material properties of orthotropic cylindrical vessels immersed in fluids. Sensitivity analyses and a simulated inverse problem are shown to quantify the potential for material characterization through th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.07.004

    authors: Rosario DE,Brigham JC,Aquino W

    更新日期:2008-11-01 00:00:00

  • The dispersion and attenuation of the multi-physical fields coupled waves in a piezoelectric semiconductor.

    abstract::The dispersion and attenuation features of the multi-physical fields coupled waves propagating in an infinite piezoelectric semiconductor and the reflection problem at a boundary which is mechanically free, electrically insulation and the dielectrically open circuit are studied in this paper. Different from the classi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.09.009

    authors: Jiao F,Wei P,Zhou X,Zhou Y

    更新日期:2019-02-01 00:00:00

  • High accuracy non-contact ultrasonic thickness gauging of aluminium sheet using electromagnetic acoustic transducers.

    abstract::Aluminium sheet thickness has been calculated from ultrasonic data obtained using a send-receive, radially polarised electromagnetic acoustic transducer (EMAT). Sheets in the thickness range between 0.1 and 0.5 mm have been measured using this non-contact approach at a stand-off of up to 1.5 mm. Normal incidence shear...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(01)00083-x

    authors: Dixon S,Edwards C,Palmer SB

    更新日期:2001-10-01 00:00:00

  • Potential of ultrasonic pulse velocity for evaluating the dimensional stability of oak and chestnut wood.

    abstract::The objective of this study was to examine the potential of ultrasonic velocity as a rapid and nondestructive method to predict the dimensional stability of oak (Quercus petraea (Mattuschka) Lieblein) and chestnut (Castanea sativa Mill.) that are commonly used in flooring industry. Ultrasonic velocity, specific gravit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.11.007

    authors: Dündar T,Wang X,As N,Avcı E

    更新日期:2016-03-01 00:00:00

  • Inversion algorithm for Lamb-wave-based depth characterization of acoustic emission sources in plate-like structures.

    abstract::An inversion algorithm (termed AEDep) is proposed for estimating the depth of acoustic emission (AE) sources in plate-like structural components. The work is motivated by the need for characterizing early-stage fatigue crack growth in such components. The algorithm achieves depth estimation by automatically extracting...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105975

    authors: Dubuc B,Ebrahimkhanlou A,Livadiotis S,Salamone S

    更新日期:2019-11-01 00:00:00

  • Inline ultrasonic rheometry by pulsed Doppler.

    abstract::This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.027

    authors: Pfund DM,Greenwood MS,Bamberger JA,Pappas RA

    更新日期:2006-12-22 00:00:00

  • Absence of biological damage from prolonged exposure to intravascular ultrasound: a swine model.

    abstract::Ultrasound (US) has been used in IMS II (intravascular US) and CLOTBUST (transcranial US) clinical trials for thrombolysis. During the treatment, in addition to the targeted thrombus, other biological components, such as blood and vessel walls are subjected to long durations of US exposure. In this study we explored e...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.10.004

    authors: Soltani A,Singhal R,Garcia JL,Raju NR

    更新日期:2007-03-01 00:00:00

  • Limited damage of tissue mimic caused by a collapsing bubble under low-frequency ultrasound exposure.

    abstract::In this study, we investigated the bubble induced serious damage to tissue mimic exposed to 27-kHz ultrasound. The initial bubble radius ranged from 80 to 100 μm, which corresponded approximately to the experimentally-evaluated resonant radius of the given ultrasound frequency. The tissue mimic consisted of 10 wt% gel...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.011

    authors: Yoshida K,Obata K,Tsukamoto A,Ushida T,Watanabe Y

    更新日期:2014-08-01 00:00:00

  • Finite element modeling of grain size effects on the ultrasonic microstructural noise backscattering in polycrystalline materials.

    abstract::The correlation between ultrasonic wave propagation and polycrystalline microstructures has significant implications in nondestructive evaluation. An original numerical approach using the finite element method to quantify in both time and frequency domains the ultrasonic noise scattering due to the elastic heterogenei...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.02.008

    authors: Bai X,Tie B,Schmitt JH,Aubry D

    更新日期:2018-07-01 00:00:00

  • Sensitivity to point-spread function parameters in medical ultrasound image deconvolution.

    abstract::Clinical ultrasound images are often perceived as difficult to interpret due to image blurring and speckle inherent in the ultrasound imaging. But the image quality can be improved by deconvolution using an estimate of the point-spread function. However, it is difficult to obtain a sufficiently accurate estimate of th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.005

    authors: Shin HC,Prager R,Ng J,Gomersall H,Kingsbury N,Treece G,Gee A

    更新日期:2009-03-01 00:00:00

  • A novel method for Estimating Time of Flight of ultrasonic echoes through short-time Fourier transforms.

    abstract::The accurate estimation of time of flight (TOF) of an ultrasonic signal is essential in ultrasonic non-destructive testing (NDT). A novel method for TOF estimation based on the short-time Fourier transform (STFT) is proposed in this paper. Firstly, the time and frequency components of ultrasonic echoes are represented...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106104

    authors: Lu Z,Ma F,Yang C,Chang M

    更新日期:2020-04-01 00:00:00

  • Excitation and detection of evanescent acoustic waves in piezoelectric plates: Theoretical and 2D FEM modeling.

    abstract::This paper presents the results of the theoretical and 2D FEM modeling excitation and detection of evanescent acoustic waves in piezoelectric plates. By application of 2D ordinary differential equations derived by Auld, we obtained the dispersion curves of A1 and SH1 waves in YX LiNbO3 and YX KNbO3 plates in proximity...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105961

    authors: Kuznetsova I,Nedospasov I,Smirnov A,Qian ZH,Wang B,Dai XY

    更新日期:2019-11-01 00:00:00

  • Probing the limits of full-field linear local defect resonance identification for deep defect detection.

    abstract::Local Defect Resonance (LDR) is exploited for non-destructive testing (NDT) by using ultrasonic vibrations to get a localized resonant activation of defected zones. The LDR technique relies on the local stiffness difference between the defect and the sound material. Analyzing the structure's displacement field at this...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106130

    authors: Segers J,Hedayatrasa S,Poelman G,Van Paepegem W,Kersemans M

    更新日期:2020-07-01 00:00:00

  • Effect of carrier and particle concentration on ultrasound properties of magnetic nanofluids.

    abstract::Ultrasound wave propagation in nanofluids and its rheological behavior has been studied as a function of solid volume fraction, temperature and magnetic field for magnetic nanofluids synthesized in kerosene and transformer oil. Ultrasonic velocity decreases while viscosity increases with increasing volume fraction. Th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.08.017

    authors: Patel JK,Parekh K

    更新日期:2015-01-01 00:00:00

  • Experimental and numerical study of evanescent waves in the mini stopband of a 1D phononic crystal.

    abstract::This paper deals with the analysis of the guided evanescent waves in stopbands of a 1D phononic crystal (PC). A new numerical implementation is shown in order to get the complex values of the wavenumbers in a frequency range where a gap occurs. The considered phononic system is an aluminum plate with a one-dimensional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.09.009

    authors: Bavencoffe M,Morvan B,Hladky-Hennion AC,Izbicki JL

    更新日期:2013-02-01 00:00:00

  • Ultrasonic digital interferometer for investigation of blood clotting.

    abstract::The digital ultrasonic fixed path interferometer designed for testing small amounts of sample was used for the investigation of whole blood coagulation, retraction and clot melting processes. The ultrasound velocity and absorption are determined from the characteristics of an acoustic resonator consisting of an emitte...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(78)90007-0

    authors: Grybauskas P,Kundrotas K,Sukackas V,Yaronis E

    更新日期:1978-01-01 00:00:00

  • Control of the ultrasonic beam transmitted through an irregular profile using a smart flexible transducer: modelling and application.

    abstract::In most of industries as aeronautics, aerospace and nuclear, the main part of the ultrasonic testing is carried out directly in touch with the inspected component. Among others, the cooling piping of French pressurized water reactor comprises many welding components with complex geometry: elbows, butt welds, nozzles. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00145-2

    authors: Roy O,Mahaut S,Casula O

    更新日期:2002-05-01 00:00:00

  • Effects of ultrasonic vibrations in micro-groove turning.

    abstract::Ultrasonic vibration cutting is an efficient cutting process for mechanical micro-machining. This process can generate intricate surface textures with different geometric characteristics. Micro-grooves/micro-channels are among the most frequently encountered micro-structures and, as such, are the focus of this paper. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.12.016

    authors: Zhang C,Guo P,Ehmann KF,Li Y

    更新日期:2016-04-01 00:00:00

  • A comparative analysis of multi-pulse techniques in contrast-enhanced ultrasound medical imaging.

    abstract::One of the important issues in the field of ultrasound medical imaging using contrast agents is the development of techniques able to separate the response of the contrast media from that of the biological tissues. In the literature, one can find various solutions involving the use of multiple transmitted signals and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.05.008

    authors: Crocco M,Palmese M,Sciallero C,Trucco A

    更新日期:2009-01-01 00:00:00

  • An ultrasonic method for measuring the elastic properties of human tibial cortical and cancellous bone.

    abstract::Ultrasonic techniques have been used to measure the elastic properties of bone. Eight human tibiae were used to determine and map the elastic properties of cortical and cancellous bone. The present study shows cortical bone to be at least orthotropic in its material symmetry. The mechanical properties of cortical bone...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(96)00078-9

    authors: Rho JY

    更新日期:1996-12-01 00:00:00

  • Spatial-temporal three-dimensional ultrasound plane-by-plane active cavitation mapping for high-intensity focused ultrasound in free field and pulsatile flow.

    abstract::Cavitation plays important roles in almost all high-intensity focused ultrasound (HIFU) applications. However, current two-dimensional (2D) cavitation mapping could only provide cavitation activity in one plane. This study proposed a three-dimensional (3D) ultrasound plane-by-plane active cavitation mapping (3D-UPACM)...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.010

    authors: Ding T,Hu H,Bai C,Guo S,Yang M,Wang S,Wan M

    更新日期:2016-07-01 00:00:00

  • On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent.

    abstract::The goal standard of contrast echocardiography is the absolute measure of myocardial perfusion using a contrast agent. Actually, several contrast agents are developed. All these agents show left ventricular opacification after intravenous injection. However, none of these agents shows an acceptable enhancement of the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(97)00137-6

    authors: Bouakaz A,de Jong N,Cachard C,Jouini K

    更新日期:1998-02-01 00:00:00

  • Optimized ultrasonic attenuation measures for non-homogeneous materials.

    abstract::In this paper the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous materials is addressed. To determine the attenuation accurately over a wide frequency range, it is necessary to have suitable excitation techniques. Three kinds of transmitted signals have been analysed, grouped according t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.09.007

    authors: Genovés V,Gosálbez J,Carrión A,Miralles R,Payá J

    更新日期:2016-02-01 00:00:00