Control of the ultrasonic beam transmitted through an irregular profile using a smart flexible transducer: modelling and application.

Abstract:

:In most of industries as aeronautics, aerospace and nuclear, the main part of the ultrasonic testing is carried out directly in touch with the inspected component. Among others, the cooling piping of French pressurized water reactor comprises many welding components with complex geometry: elbows, butt welds, nozzles. In service inspections of such components performed with conventional ultrasonic contact transducers present limited performances. Variations in sensitivity are produced by unmatched contact on irregular surface, which results in poor detection performances. In addition, the beam orientation transmitted through complex interfaces cannot be totally controlled, because of the disorientations suffered by the transducer during its displacement. As a result, a possible defect cannot be correctly detected, positioned and characterized. At last, the geometry of some components limits the displacement of the transducer, resulting in an uncovered scan area. To overcome these difficulties and to improve the performances of such inspections, the CEA, supported by the safety authorities (IPSN), has developed a new concept of phased array transducer. The phased array radiating surface is flexible to optimise the contact, and thus the sensitivity of the testing, while the characteristics of the transmitted beam (orientation and focal depth) are preserved during the scanning, thanks to a delay law optimising algorithm. This computation requires the actual position of the elements, so a specific instrumentation is coupled to the transducer to measure its radiating surface distortions. Thus, this smart flexible transducer becomes self-adaptive. Recent studies have been made to obtain further performances improvements of this system, including instrumentation development and a new phased array design. Both longitudinal and shear waves focused beams can therefore be generated and mastered with this smart transducer. Inspections have been performed on a specimen containing artificial defects under a realistic profile, with an adaptive mode to compensate the effect of the irregular profile. Experimental results, displayed using specific imaging, show the ability of this system to detect and characterize defects under irregular profiles, using longitudinal or shear waves in a fully mastered beam.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Roy O,Mahaut S,Casula O

doi

10.1016/s0041-624x(02)00145-2

subject

Has Abstract

pub_date

2002-05-01 00:00:00

pages

243-6

issue

1-8

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(02)00145-2

journal_volume

40

pub_type

杂志文章
  • Nondestructive testing using air-borne ultrasound.

    abstract::Over the last two decades, more efficient transducers were developed for the generation and reception of air-borne ultrasound, thus enabling the non-contact, non-contaminating inspection of composite laminates and honeycomb structures widely used in the aerospace industry. This paper presents the fundamentals of makin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.091

    authors: Hsu DK

    更新日期:2006-12-22 00:00:00

  • 100 MHz bandwidth planar laser-generated ultrasound source for hydrophone calibration.

    abstract::High-frequency calibration of hydrophones is becoming increasingly important, both for clinical and scientific applications of ultrasound, and user safety. At present, the calibrations available routinely to the user community extend to 60 MHz. However, hydrophones that can measure beyond this are available, and ultra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106218

    authors: Rajagopal S,Cox BT

    更新日期:2020-12-01 00:00:00

  • Finite element modeling of grain size effects on the ultrasonic microstructural noise backscattering in polycrystalline materials.

    abstract::The correlation between ultrasonic wave propagation and polycrystalline microstructures has significant implications in nondestructive evaluation. An original numerical approach using the finite element method to quantify in both time and frequency domains the ultrasonic noise scattering due to the elastic heterogenei...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.02.008

    authors: Bai X,Tie B,Schmitt JH,Aubry D

    更新日期:2018-07-01 00:00:00

  • A novel method for Estimating Time of Flight of ultrasonic echoes through short-time Fourier transforms.

    abstract::The accurate estimation of time of flight (TOF) of an ultrasonic signal is essential in ultrasonic non-destructive testing (NDT). A novel method for TOF estimation based on the short-time Fourier transform (STFT) is proposed in this paper. Firstly, the time and frequency components of ultrasonic echoes are represented...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106104

    authors: Lu Z,Ma F,Yang C,Chang M

    更新日期:2020-04-01 00:00:00

  • Biomechanical characterization of ex vivo human brain using ultrasound shear wave spectroscopy.

    abstract::The characterization of brain tissue is crucial to better understand neurological disorders. Mechanical characterization is an emerging tool in that field. The purpose of this work was to validate a transient ultrasound technique aimed at measuring dispersion of mechanical parameters of the brain tissue. The first par...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.10.009

    authors: Nicolas E,Callé S,Nicolle S,Mitton D,Remenieras JP

    更新日期:2018-03-01 00:00:00

  • Solid volume fraction estimation of bone:marrow replica models using ultrasound transit time spectroscopy.

    abstract::The acceptance of broadband ultrasound attenuation (BUA) for the assessment of osteoporosis suffers from a limited understanding of both ultrasound wave propagation through cancellous bone and its exact dependence upon the material and structural properties. It has recently been proposed that ultrasound wave propagati...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.09.009

    authors: Wille ML,Langton CM

    更新日期:2016-02-01 00:00:00

  • An improved Richardson-Lucy iterative algorithm for C-scan image restoration and inclusion size measurement.

    abstract::The accuracy of measuring inclusion size in direct C-scan image of immersion ultrasonic testing is restricted by the lateral resolution of the focused transducer, even if a high frequency is used, and the blurred edge due to scattering of sound waves at inclusions. In this work, an improved image restoration method th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.07.021

    authors: Chen D,Xiao H,Xu J

    更新日期:2019-01-01 00:00:00

  • Effect of texture and grain shape on ultrasonic backscattering in polycrystals.

    abstract::An ultrasonic backscattering model is developed for textured polycrystalline materials with orthotropic or trigonal grains of ellipsoidal shape. The model allows us to simulate realistic microstructures and orthotropic macroscopic material textures resulting from thermomechanical processing for a broad variety of mate...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.02.020

    authors: Li J,Yang L,Rokhlin SI

    更新日期:2014-09-01 00:00:00

  • Influence of extrinsic operational parameters on salt diffusion during ultrasound assisted meat curing.

    abstract::The present study investigated the effect of geometric parameters of the ultrasound instrument during meat salting in order to enhance salt diffusion and salt distribution in pork meat on a lab scale. The effects of probe size (∅2.5 and 1.3cm) and of different distances between the transducer and the meat sample (0.3,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.017

    authors: Inguglia ES,Zhang Z,Burgess C,Kerry JP,Tiwari BK

    更新日期:2018-02-01 00:00:00

  • Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels.

    abstract::Experimental studies of thermal effects in high-intensity focused ultrasound (HIFU) procedures are often performed with the aid of fine wire thermocouples positioned within tissue phantoms. Thermocouple measurements are subject to several types of error which must be accounted for before reliable inferences can be mad...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.07.007

    authors: Dasgupta S,Banerjee RK,Hariharan P,Myers MR

    更新日期:2011-02-01 00:00:00

  • A prosthetic aid for a developing blind child.

    abstract::An experimental ultrasonic sonar for use as a sensory aid with blind children is described. Novel signal processing techniques make the aid relatively simple to construct, yet allow many of its parameters to be changed in the field. In particular, the aid has two features, a variable range code and an automatic level...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(79)90010-6

    authors: Boys JT,Strelow ER,Clark GR

    更新日期:1979-01-01 00:00:00

  • Thickness-shear vibration of a quartz plate connected to piezoelectric plates and electric field sensing.

    abstract::We study thickness-shear vibration of a quartz plate connected to two piezoelectric ceramic plates with initial deformations caused by a biasing electric field. The theory for small deformations superposed on finite biasing deformations in an electroelastic body is used. It is shown that the resonant frequencies of th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.07.002

    authors: Zhou Y,Chen W,Yang J,Du J

    更新日期:2011-02-01 00:00:00

  • Experimental and numerical study of evanescent waves in the mini stopband of a 1D phononic crystal.

    abstract::This paper deals with the analysis of the guided evanescent waves in stopbands of a 1D phononic crystal (PC). A new numerical implementation is shown in order to get the complex values of the wavenumbers in a frequency range where a gap occurs. The considered phononic system is an aluminum plate with a one-dimensional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.09.009

    authors: Bavencoffe M,Morvan B,Hladky-Hennion AC,Izbicki JL

    更新日期:2013-02-01 00:00:00

  • Tissue characterization of arteries with 4 MHz ultrasound.

    abstract::Reflections of 4 MHz ultrasound pulses from 60 sites on 15 human aorta specimens were analysed using the plane-wave Born approximation (PWBA) inverse scattering method. The recovered high-resolution acoustic impedance profile for each site was correlated with an analysis (by microscope) of sections taken from that sit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(95)00025-x

    authors: Tobocman W,Santosh K,Carter JR,Haacke EM

    更新日期:1995-07-01 00:00:00

  • Sensitivity of a miniaturized touch probe sensor using PZT thin film vibrator.

    abstract::In this paper, an improved touch probe sensor device for higher sensitivity and low contact force is reported. In order to improve the resolution, we have evaluated the sensitivity and fabricated a miniaturized sensor. The sensor transducer was 3 mm long and had higher resonance frequency. The resonance frequency of t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00091-4

    authors: Kanda T,Kurosawa MK,Higuchi T

    更新日期:2002-05-01 00:00:00

  • The effect of the conductivity of a film located near a piezoelectric resonator with a lateral electric field based on the PZT ceramics on its characteristics.

    abstract::In this paper, we investigated theoretically and experimentally the effect of the conductivity of the film located in the immediate vicinity of the free side of a piezoelectric resonator based on the PZT ceramics on its characteristics. It is shown that with increasing the conductivity of the film at first the paralle...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.09.016

    authors: Zaitsev BD,Semyonov AP,Teplykh AA,Borodina IA

    更新日期:2019-04-01 00:00:00

  • Remote characterization of defects in plates with viscoelastic coatings using guided waves.

    abstract::The remote inspection for defects in large metallic elements such as pipes, tubes and plates is a field where guided waves are being applied with success. There are a number of situations where a surface coating is added for corrosion protection or insulation purposes. Since the coating materials are usually viscoelas...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.072

    authors: Galán JM,Abascal R

    更新日期:2004-04-01 00:00:00

  • Stoneley-type waves in anisotropic periodic superlattices.

    abstract::The paper investigates the existence of interfacial (Stoneley-type) acoustic waves localised at the internal boundary between two semi-infinite superlattices which are adjoined with each other to form one-dimensional phononic bicrystal. Each superlattice is a periodic sequence of perfectly bonded homogeneous and/or fu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106237

    authors: Darinskii AN,Shuvalov AL

    更新日期:2021-01-01 00:00:00

  • The design of a high power ultrasonic test cell using finite element modelling techniques.

    abstract::This paper will describe the application of a finite element (FE) code to design a test cell, in which a single transducer is used to generate acoustic cavitation. The FE model comprises a 2-D slice through the centre of the test cell and was used to evaluate the generated pressure fields as a function of frequency. I...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00453-5

    authors: Gachagan A,Speirs D,McNab A

    更新日期:2003-06-01 00:00:00

  • Analysis of multiple wavelengths of Lamb waves generated by meander-line coil EMATs.

    abstract::The electromagnetic acoustic transducers (EMATs) with a meander-line coil possess the capability of generating Lamb waves carrying multiple wavelengths, and the characteristics of multiple wavelengths is analyzed by developing a spatial transversal filter model for the EMAT. It is shown that the characteristics is due...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.003

    authors: Zhai G,Jiang T,Kang L

    更新日期:2014-02-01 00:00:00

  • The peculiarities of the Bleustein-Gulyaev wave propagation in structures containing conductive layer.

    abstract::As known, anomalous resisto-acoustic effect is a fundamental property for weakly inhomogeneous piezoactive waves (Bleustein-Gulyaev, Love, and some leaky waves). It consists in that the velocity of aforementioned waves first increases, achieves its maximum, and only then decreases with increasing conductance of a laye...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.007

    authors: Kuznetsova IЕ,Zaitsev BD

    更新日期:2015-05-01 00:00:00

  • Dependence of sonochemical luminescence on various sound fields

    abstract::To understand the effect of the sound field on sonochemical luminescence, the exact sound pressure must be determined in each field. In this study it was determined by the Shlieren method, which measures the sound pressure without mixing the sound fields. We compared the efficiency of the sonochemical luminescence in ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00203-6

    authors: Yanagida H,Masubuchi Y,Minagawa K,Takimoto J,Ogata T,Koyama K

    更新日期:2000-03-01 00:00:00

  • Wide bandwidth fiber-optic ultrasound probe in MOMS technology: Preliminary signal processing results.

    abstract::An ultrasonic probe consisting of two optical fiber-based miniaturized transducers for wideband ultrasound emission and detection is employed for the characterization of in vitro biological tissues. In the probe, ultrasound generation is obtained by thermoelastic emission from patterned carbon films in Micro-Opto-Mech...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.024

    authors: Vannacci E,Granchi S,Belsito L,Roncaglia A,Biagi E

    更新日期:2017-03-01 00:00:00

  • Two dimensional modeling of elastic wave propagation in solids containing cracks with rough surfaces and friction - Part II: Numerical implementation.

    abstract::Our study aims at the creation of a numerical toolbox that describes wave propagation in samples containing internal contacts (e.g. cracks, delaminations, debondings, imperfect intergranular joints) of known geometry with postulated contact interaction laws including friction. The code consists of two entities: the co...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.07.003

    authors: Delrue S,Aleshin V,Truyaert K,Bou Matar O,Van Den Abeele K

    更新日期:2018-01-01 00:00:00

  • Therapeutic opportunities in biological responses of ultrasound.

    abstract::The therapeutic benefits of several existing ultrasound-based therapies such as facilitated drug delivery, tumor ablation and thrombolysis derive largely from physical or mechanical effects. In contrast, ultrasound can also trigger various time-dependent biochemical responses in the exposed biological milieu. Several ...

    journal_title:Ultrasonics

    pub_type: 杂志文章,评审

    doi:10.1016/j.ultras.2008.02.002

    authors: Paliwal S,Mitragotri S

    更新日期:2008-08-01 00:00:00

  • Ultrasonic characterization of Cu-Al-Ni single crystals lattice stability in the vicinity of the phase transition.

    abstract::Measurements of elastic constants of the austenite phase when approaching the phase transformation either upon cooling or stressing is of the crucial interest for the shape memory alloy field. Acoustic properties (wave velocity and also attenuation changes) of the Cu-Al-Ni single crystal were investigated in situ duri...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.029

    authors: Landa M,Novák V,Sedlák P,Sittner P

    更新日期:2004-04-01 00:00:00

  • Miniaturization of surface acoustic waves rotary motor.

    abstract::This paper presents the experimental study of a miniaturized surface acoustic waves (SAWs) rotary motor and the theoretical calculation. After the first success in SAW rotary motor operating at 9.85 MHz, a smaller rotary motor is designed. With the operating frequency of 30 MHz and the driving voltage of 120 V(p-p), t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00264-0

    authors: Cheng LP,Zhang GM,Zhang SY,Yu J,Shui XJ

    更新日期:2002-06-01 00:00:00

  • Imaging microbubbles and tissues using a linear focussed scanner operating at 20 MHz: possible implications for the detection of cavitation thresholds.

    abstract::B-Scan images have been used as a means of detecting the onset of cavitation in tissues. New echoes appearing during simultaneous sonication with therapeutic ultrasound have often been attributed to bubble formation. In this study temperature rises up to 15 degrees C W-1 cm2 in guinea pig leg (post-mortem) were found,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(91)90028-7

    authors: Watmough DJ,Davies HM,Quan KM,Wytch R,Williams AR

    更新日期:1991-07-01 00:00:00

  • Microbiological properties of poultry breast meat treated with high-intensity ultrasound.

    abstract::Lactic acid, psychrophilic, and mesophilic bacteria, Escherichia coli, Salmonella spp. and Staphylococcus aureus were enumerated on chicken breasts after treatment with different high intensity ultrasound (frequency 40 kHz, intensity 9.6 W/cm-2) application times (0, 30, and 50 min) and packaging atmospheres (aerobic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.01.001

    authors: Piñon MI,Alarcon-Rojo AD,Renteria AL,Carrillo-Lopez LM

    更新日期:2020-03-01 00:00:00

  • Simulation of electromechanical coupling coefficient by modified modal frequency spectrum method including the electrode effect

    abstract::An approximate formula has been developed to determine the electromechanical coupling coefficient of the piezoelectric film in a four-layer composite resonator, which includes two electrodes. In this formula, the coupling coefficient can be calculated from the distribution of the effective coupling coefficients, k2eff...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00172-9

    authors: Zhang Y,Wang Z,Cheeke JD

    更新日期:2000-03-01 00:00:00