Dependence of sonochemical luminescence on various sound fields

Abstract:

:To understand the effect of the sound field on sonochemical luminescence, the exact sound pressure must be determined in each field. In this study it was determined by the Shlieren method, which measures the sound pressure without mixing the sound fields. We compared the efficiency of the sonochemical luminescence in three different ways: changing the diameter of the transducer, combining two transducers to obtain crossed propagating directions and surrounding the sound field by a glass cylinder. In the last case cylinders with various sizes were studied. We found that (i) at the same sound pressure, the larger transducer induces stronger luminescence per unit volume, (ii) driving two transducers produces stronger luminescence than the sum of each transducer and (iii) a glass cylinder surrounding the sound field induces stronger luminescence.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Yanagida H,Masubuchi Y,Minagawa K,Takimoto J,Ogata T,Koyama K

doi

10.1016/s0041-624x(99)00203-6

subject

Has Abstract

pub_date

2000-03-01 00:00:00

pages

671-5

issue

1-8

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(99)00203-6

journal_volume

38

pub_type

杂志文章
  • Effects of ultrasonic vibrations in micro-groove turning.

    abstract::Ultrasonic vibration cutting is an efficient cutting process for mechanical micro-machining. This process can generate intricate surface textures with different geometric characteristics. Micro-grooves/micro-channels are among the most frequently encountered micro-structures and, as such, are the focus of this paper. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.12.016

    authors: Zhang C,Guo P,Ehmann KF,Li Y

    更新日期:2016-04-01 00:00:00

  • Optimizing graphene production in ultrasonic devices.

    abstract::In this work, we investigate the efficiency of graphene production from graphite by ultrasonic-induced exfoliation under different operational conditions. An ultrasonic bath and an ultrasonic horn tip were used, to show how the graphene production efficiency depends on the acoustic intensity and cavitation mechanism u...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105989

    authors: Silva LI,Mirabella DA,Pablo Tomba J,Riccardi CC

    更新日期:2020-01-01 00:00:00

  • A novel method for Estimating Time of Flight of ultrasonic echoes through short-time Fourier transforms.

    abstract::The accurate estimation of time of flight (TOF) of an ultrasonic signal is essential in ultrasonic non-destructive testing (NDT). A novel method for TOF estimation based on the short-time Fourier transform (STFT) is proposed in this paper. Firstly, the time and frequency components of ultrasonic echoes are represented...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106104

    authors: Lu Z,Ma F,Yang C,Chang M

    更新日期:2020-04-01 00:00:00

  • Dynamic interrogator for elastic wave sensing using Fabry Perot filters based on fiber Bragg gratings.

    abstract::Use of in-fiber Fabry-Perot (FP) filters based on fiber Bragg gratings as both sensor as well as an interrogator for enhancing the detection limit of elastic wave sensing is investigated in this paper. The sensitivity of such a demodulation scheme depends on the spectral discrimination of the sensor and interrogator g...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.02.018

    authors: Harish AV,Varghese B,Rao B,Balasubramaniam K,Srinivasan B

    更新日期:2015-07-01 00:00:00

  • Characterization of air-coupled ultrasound transducers in the frequency range 40 kHz-2 mHz using light diffraction tomography.

    abstract::The aim of this work was to show the applicability of light diffraction tomography on airborne ultrasound in the frequency range 40 kHz-2 MHz. Seven different air-coupled transducers were measured to show the method's performance regarding linearity, absolute pressure measurements, phase measurements, frequency respon...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00168-7

    authors: Almqvist M,Holm A,Persson HW,Lindström K

    更新日期:2000-01-01 00:00:00

  • Imaging microbubbles and tissues using a linear focussed scanner operating at 20 MHz: possible implications for the detection of cavitation thresholds.

    abstract::B-Scan images have been used as a means of detecting the onset of cavitation in tissues. New echoes appearing during simultaneous sonication with therapeutic ultrasound have often been attributed to bubble formation. In this study temperature rises up to 15 degrees C W-1 cm2 in guinea pig leg (post-mortem) were found,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(91)90028-7

    authors: Watmough DJ,Davies HM,Quan KM,Wytch R,Williams AR

    更新日期:1991-07-01 00:00:00

  • Effect of texture and grain shape on ultrasonic backscattering in polycrystals.

    abstract::An ultrasonic backscattering model is developed for textured polycrystalline materials with orthotropic or trigonal grains of ellipsoidal shape. The model allows us to simulate realistic microstructures and orthotropic macroscopic material textures resulting from thermomechanical processing for a broad variety of mate...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.02.020

    authors: Li J,Yang L,Rokhlin SI

    更新日期:2014-09-01 00:00:00

  • Generation of sub-microsecond quasi-unipolar pressure pulses.

    abstract::We present a method to generate sub-microsecond quasi-unipolar pressure pulses. Our approach is based on the laser irradiation of a thin copper wire submerged in water. The acoustic waveforms were recorded using two different, well characterized, wideband detection techniques: piezoelectric and optical interferometry....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.05.002

    authors: González MG,Riobó LM,Ciocci Brazzano L,Veiras FE,Sorichetti PA,Santiago GD

    更新日期:2019-09-01 00:00:00

  • Micromachined ultrasound transducers with improved coupling factors from a CMOS compatible process

    abstract::For medical high frequency acoustic imaging purposes the reduction in size of a single transducer element for one-dimensional and even more for two-dimensional arrays is more and more limited by fabrication and cabling technology. In the fields of industrial distance measurement and simple object recognition low cost ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00085-2

    authors: Eccardt PC,Niederer K

    更新日期:2000-03-01 00:00:00

  • Volume reconstruction of freehand three-dimensional ultrasound using median filters.

    abstract:OBJECTIVES:This paper aims to apply median filters for reducing interpolation error and improving the quality of 3D images in a freehand 3D ultrasound (US) system. BACKGROUND AND MOTIVATION:Freehand 3D US imaging has been playing an important role in obtaining the entire 3D impression of tissues and organs. Reconstruc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.11.005

    authors: Huang QH,Zheng YP

    更新日期:2008-07-01 00:00:00

  • Experimental and numerical investigations of mechanical displacements in surface acoustic wave bounded beams.

    abstract::The present paper studies experimentally and numerically the surface acoustic wave (SAW) field on a piezoelectric substrate generated by interdigital transducers (IDT). On the one hand, mechanical displacements produced by the SAW are measured with the help of a laser Doppler vibrometer. On the other hand, mechanical ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106077

    authors: Weser R,Darinskii AN,Weihnacht M,Schmidt H

    更新日期:2020-08-01 00:00:00

  • Optimization of electrode size for aluminum-nitride matrix ultrasonic transducers in the frequency range above 200 MHz.

    abstract::This paper describes an optimization method of the top electrode size for a thin film matrix ultrasonic transducer (M-UT) in the frequency range above 200 MHz. The goal of this work is to design an optimal top electrode size for an M-UT providing the maximal output peak-peak voltage (V(PP)) and the maximal signal-to-n...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.10.018

    authors: Wei Y,Herzog T,Heuer H

    更新日期:2013-03-01 00:00:00

  • Investigations of the barbell ultrasonic transducer operated in the full-wave vibrational mode.

    abstract::In this paper, the resonance frequency equation and expression of displacement amplitude magnifications of a full-wave barber ultrasonic horn are obtained. By discussing the relationships between the displacement amplitude magnifications and the geometrical dimensions, the optimized design of the horn for the largest ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.12.006

    authors: Fu Z,Xian X,Lin S,Wang C,Hu W,Li G

    更新日期:2012-07-01 00:00:00

  • Surface vibrational modes in disk-shaped resonators.

    abstract::The natural frequencies and distributions of displacement components for the surface vibrational modes in thin isotropic elastic disks are calculated. In particular, the research is focused on even solutions for low-lying resonant vibrations with large angular wave numbers. Several families of modes are found which ar...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.11.002

    authors: Dmitriev AV,Gritsenko DS,Mitrofanov VP

    更新日期:2014-03-01 00:00:00

  • Three-dimensional modelling of micromachined-ultrasonic-transducer arrays operating in water.

    abstract::We report on the 3-D modelling of periodic arrays of capacitive micromachined ultrasonic transducers (cMUTs) operating in fluid. Specific developments have been performed to model biperiodic transducer arrays and to take into account radiation into any stratified media at the front-side as well as the back-side of the...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.09.006

    authors: Wilm M,Reinhardt A,Laude V,Armati R,Daniau W,Ballandras S

    更新日期:2005-05-01 00:00:00

  • Inversion algorithm for Lamb-wave-based depth characterization of acoustic emission sources in plate-like structures.

    abstract::An inversion algorithm (termed AEDep) is proposed for estimating the depth of acoustic emission (AE) sources in plate-like structural components. The work is motivated by the need for characterizing early-stage fatigue crack growth in such components. The algorithm achieves depth estimation by automatically extracting...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105975

    authors: Dubuc B,Ebrahimkhanlou A,Livadiotis S,Salamone S

    更新日期:2019-11-01 00:00:00

  • Modal analysis and moving performance of a single-mode linear ultrasonic motor.

    abstract::A single-mode linear ultrasonic motor was developed in this study. On the stator, a group of four pieces of piezoelectric ceramics PZT8 were utilized to generate the ultrasonic vibration. A specially designed modal conversion horn with an oblique beam was applied to transfer the longitudinal vibration to an additional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106216

    authors: Yin Z,Dai C,Cao Z,Li W,Chen Z,Li C

    更新日期:2020-12-01 00:00:00

  • Development of a portable 3D ultrasound imaging system for musculoskeletal tissues.

    abstract::3D ultrasound is a promising imaging modality for clinical diagnosis and treatment monitoring. Its cost is relatively low in comparison with CT and MRI, no intensive training and radiation protection is required for its operation, and its hardware is movable and can potentially be portable. In this study, we developed...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.05.003

    authors: Huang QH,Zheng YP,Lu MH,Chi ZR

    更新日期:2005-01-01 00:00:00

  • Modeling electrical response of polymer-coated SAW resonators by equivalent circuit representation.

    abstract::The paper presents an equivalent circuit model of the polymer coated surface acoustic wave (SAW) resonators by combining coupling-of-mode (COM) description of SAW resonators and perturbation calculation of SAW propagation under polymer loading. An expression for the motional load produced by polymer coating is deduced...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.12.006

    authors: Kshetrimayum R,Yadava RD,Tandon RP

    更新日期:2011-07-01 00:00:00

  • A novel approach to quantitative ultrasonic naked gene delivery and its non-invasive assessment.

    abstract::The purpose of this study was to investigate practical, safe, easy-to-use, non-cytotoxic, and reliable parameters to apply to an ultrasound (US) naked gene therapy system. The ultrasound pressure at the point of cell exposure was measured using a calibrated hydrophone and the intensity calculated. An acoustic power me...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.06.007

    authors: Wei W,Zhengzhong B,Yongjie W,Lafeng Y,Yalin M

    更新日期:2004-12-01 00:00:00

  • Nondestructive evaluation of steel-concrete composite structure using high-frequency ultrasonic guided wave.

    abstract::Steel-concrete modular construction is increasingly used in nuclear structure construction. Conventional nondestructive testing methods are not able to detect internal concrete defects because the thick concrete wall is covered by steel plates. An ultrasonic guided method is proposed to detect honeycombs and voids aro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106096

    authors: Sun H,Zhu J

    更新日期:2020-04-01 00:00:00

  • Arbitrary shaped, liquid filled reverberators with non-resonant transducers for broadband focusing of ultrasound using Time Reversed Acoustics.

    abstract::The ability to generate short focused ultrasonic pulses with duration on the order of one period of carrier frequency depends on the bandwidth of the transmitter as the pulse duration is inversely proportional to the bandwidth. Conventional focusing arrays used for focusing ultrasound have limited bandwidth due to the...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.008

    authors: Sarvazyan A,Fillinger L

    更新日期:2009-03-01 00:00:00

  • Frequency dependence of H2O2 generation from distilled water

    abstract::The frequency dependence of H2O2 generation from H2O by a sonochemical reaction was detected experimentally. The results are in good agreement with previous experimental results, which indicate that in sonochemical reactions, frequencies higher than 90 kHz are more effective than frequencies of several tens of kiloher...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00114-6

    authors: Sato M,Itoh H,Fujii T

    更新日期:2000-03-01 00:00:00

  • The peculiarities of the Bleustein-Gulyaev wave propagation in structures containing conductive layer.

    abstract::As known, anomalous resisto-acoustic effect is a fundamental property for weakly inhomogeneous piezoactive waves (Bleustein-Gulyaev, Love, and some leaky waves). It consists in that the velocity of aforementioned waves first increases, achieves its maximum, and only then decreases with increasing conductance of a laye...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.007

    authors: Kuznetsova IЕ,Zaitsev BD

    更新日期:2015-05-01 00:00:00

  • Sensitivity improvement of a pump-probe set-up for thin film and microstructure metrology.

    abstract::This investigation deals with various new aspects of the sensitivity improvement of a pump-probe laser based acoustic method. A short laser pulse is used to excite a mechanical pulse thermo-elastically. Echoes of these mechanical pulses reaching the surface are causing a slight change of the optical reflectivity. The ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00207-x

    authors: Vollmann J,Profunser DM,Dual J

    更新日期:2002-05-01 00:00:00

  • The quasi-harmonic ultrasonic polar scan for material characterization: experiment and numerical modeling.

    abstract::Conventionally, the ultrasonic polar scan (UPS) records the amplitude or time-of-flight in transmission using short ultrasonic pulses for a wide range of incidence angles, resulting in a fingerprint of the critical bulk wave angles of the material at the insonified spot. Here, we investigate the use of quasi-harmonic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.002

    authors: Kersemans M,Martens A,Van Den Abeele K,Degrieck J,Pyl L,Zastavnik F,Sol H,Van Paepegem W

    更新日期:2015-04-01 00:00:00

  • Aperture and element minimization in linear sparse arrays with desired beam patterns

    abstract::In this paper, an optimization method aimed at designing aperiodic linear sparse arrays is proposed that is based on the stochastic optimization methodology called simulated annealing. Such a method optimizes the positions and the weight coefficients of each element of a linear array in order to obtain a beam pattern ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00089-x

    authors: Trucco A

    更新日期:2000-03-01 00:00:00

  • Coating thickness affects surface stress measurement of brush electro-plating nickel coating using Rayleigh wave approach.

    abstract::A surface ultrasonic wave approach was presented for measuring surface stress of brush electro-plating nickel coating specimen, and the influence of coating thickness on surface stress measurement was discussed. In this research, two Rayleigh wave transducers with 5MHz frequency were employed to collect Rayleigh wave ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.02.003

    authors: Liu B,Dong S,Xu B,He P

    更新日期:2012-09-01 00:00:00

  • 2D array design based on Fermat spiral for ultrasound imaging.

    abstract::The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.010

    authors: Martínez-Graullera O,Martín CJ,Godoy G,Ullate LG

    更新日期:2010-02-01 00:00:00

  • On the emergence of the Green's function in the correlations of a diffuse field: pulse-echo using thermal phonons.

    abstract::It is shown that a diffuse field is not devoid of phase information, but has a correlation function equal to the Green's function. More specifically, the cross-correlation between diffuse signals in two transducers is very nearly equal to the direct response of one transducer to an impulse applied to the other. This i...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00156-7

    authors: Weaver R,Lobkis O

    更新日期:2002-05-01 00:00:00