Development of SH-SAW sensors for underwater measurement.

Abstract:

:We developed SH (shear horizontal) surface acoustic wave (SAW) sensors to detect protein molecules in liquid solutions applying a particular antibody thin film on the delay line of transverse SAW devices. The antibody investigated was human-immuno-globulin G (HigG) to hold the antigens (anti-HigG) in the protein solution to be measured. The sensor showed stable response to the mass loading effects of the anti-HigG molecules with the sensitivity up to 10.8 ng/ml/Hz.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Kwon Y,Roh Y

doi

10.1016/j.ultras.2004.01.039

subject

Has Abstract

pub_date

2004-04-01 00:00:00

pages

409-11

issue

1-9

eissn

0041-624X

issn

1874-9968

pii

S0041624X04000423

journal_volume

42

pub_type

杂志文章
  • Non-linear actuation of cantilevers using giant magnetostrictive thin films

    abstract::In the present paper, we report the first results concerning a centimetre cantilever driven through non-linear effects in thin magnetostrictive films. Bimorph centimetre beams (24 mm x 5 mm) were designed using 160 microns thick glass and 0.4 micron thick multilayer TbFe/Fe films deposited via RF sputtering, using sev...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00061-x

    authors: Tiercelin N,Pernod P,Preobrazhensky V V,Le Gall H,Ben Youssef J

    更新日期:2000-03-01 00:00:00

  • Measurements of dispersion curves of leaky Lamb waves using a lensless line-focus transducer.

    abstract::This paper presents a new method of measuring dispersion curves of leaky Lamb waves propagating in a thin plate. The measurement system is based on a lens-less line-focus transducer and its defocusing measurement technique. A new waveform processing method known as V(f, z) method is introduced for analyzing the measur...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00069-x

    authors: Lee YC

    更新日期:2001-06-01 00:00:00

  • The influence of the thickness of non-piezoelectric pieces on pre-stressed piezotransducers.

    abstract::The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with differ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00096-9

    authors: Arnold FJ,Mühlen SS

    更新日期:2003-05-01 00:00:00

  • High accuracy non-contact ultrasonic thickness gauging of aluminium sheet using electromagnetic acoustic transducers.

    abstract::Aluminium sheet thickness has been calculated from ultrasonic data obtained using a send-receive, radially polarised electromagnetic acoustic transducer (EMAT). Sheets in the thickness range between 0.1 and 0.5 mm have been measured using this non-contact approach at a stand-off of up to 1.5 mm. Normal incidence shear...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(01)00083-x

    authors: Dixon S,Edwards C,Palmer SB

    更新日期:2001-10-01 00:00:00

  • An adaptive threshold filter for ultrasound signal rejection.

    abstract::The threshold filter is a frequently used technique in ultrasound B-scan to reject the small echoes contributed from backscattering that blur the tissue interface and reduce the image contrast. Note that using the threshold based on one value would simultaneously destroy local waveform features of the reflection echoe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.007

    authors: Tsui PH,Chang CC,Chang CC,Huang NE,Ho MC

    更新日期:2009-05-01 00:00:00

  • Numerical investigation of dispersive behaviors for helical thread waveguides using the semi-analytical isogeometric analysis method.

    abstract::In this paper, we propose a semi-analytical isogeometric analysis(S-IGA) approach in the twist space to investigate the dispersive properties in helical thread waveguides, which combines the advantages of the spectral approach and IGA. The convergence and accuracy of the proposed method are discussed, by comparing S-I...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.06.004

    authors: Liu Y,Han Q,Liang Y,Xu G

    更新日期:2018-02-01 00:00:00

  • Miniaturization of surface acoustic waves rotary motor.

    abstract::This paper presents the experimental study of a miniaturized surface acoustic waves (SAWs) rotary motor and the theoretical calculation. After the first success in SAW rotary motor operating at 9.85 MHz, a smaller rotary motor is designed. With the operating frequency of 30 MHz and the driving voltage of 120 V(p-p), t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00264-0

    authors: Cheng LP,Zhang GM,Zhang SY,Yu J,Shui XJ

    更新日期:2002-06-01 00:00:00

  • Convolutional neural network for ultrasonic weldment flaw classification in noisy conditions.

    abstract::Ultrasonic flaw classification in weldment is an active area of research and many artificial intelligence approaches have been applied to automate this process. However, in the industrial applications, the ultrasonic flaw signals are not noise free and automatic intelligent defect classification algorithms show relati...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.12.001

    authors: Munir N,Kim HJ,Park J,Song SJ,Kang SS

    更新日期:2019-04-01 00:00:00

  • Effect of texture and grain shape on ultrasonic backscattering in polycrystals.

    abstract::An ultrasonic backscattering model is developed for textured polycrystalline materials with orthotropic or trigonal grains of ellipsoidal shape. The model allows us to simulate realistic microstructures and orthotropic macroscopic material textures resulting from thermomechanical processing for a broad variety of mate...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.02.020

    authors: Li J,Yang L,Rokhlin SI

    更新日期:2014-09-01 00:00:00

  • Dynamic modeling and experimental verification of a piezoelectric part feeder in a structure with parallel bimorph beams.

    abstract::The study is aimed to perform dynamic modeling of a part feeder powered by piezoelectric actuation. This part feeder consists mainly of a horizontal platform vibrated by a pair of parallel piezoelectric bimorph beams. Owing to intermittent impacts with the platform, the transported part on the platform is able to marc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.02.002

    authors: Chao PC,Shen CY

    更新日期:2007-06-01 00:00:00

  • Analysis of multiple wavelengths of Lamb waves generated by meander-line coil EMATs.

    abstract::The electromagnetic acoustic transducers (EMATs) with a meander-line coil possess the capability of generating Lamb waves carrying multiple wavelengths, and the characteristics of multiple wavelengths is analyzed by developing a spatial transversal filter model for the EMAT. It is shown that the characteristics is due...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.003

    authors: Zhai G,Jiang T,Kang L

    更新日期:2014-02-01 00:00:00

  • Understanding the effect of methane gas sensitivity using ultrasonic sensors and multi-matching layers inside a natural gas vehicle tank.

    abstract::This research paper is the experimental study to investigate the effect of ultrasound sensitivity in the pure methane gas space as the pressure and sensor distance increases. We offer the solution to overcome the low sensitivity characteristics of ultrasonic sensors in the methane gas space. This proposal shows the ph...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105970

    authors: Kim K,Choi D,Im S

    更新日期:2019-11-01 00:00:00

  • Estimation of dispersion curves of water-loaded structures by using approximated acoustic mass.

    abstract::For coupled structures surrounded by heavy fluids, it is difficult to obtain dispersion curves from an eigenvalue analysis, because the external fluid term in the coupled equation includes transcendental functions for frequency and wavenumber. Thus, in this study, the acoustic mass of the external fluid was approximat...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.12.009

    authors: Jung BK,Ryue J,Hong C,Jeong WB,Shin KK

    更新日期:2018-04-01 00:00:00

  • High-intensity ultrasound irradiation promotes the release of extracellular vesicles from C2C12 myotubes.

    abstract::Skeletal muscle is an important secretory organ in mammals, producing myriad chemical mediators ("myokines") with distinct biological action in different tissues, including anti-inflammatory activity. Extracellular vesicles (EVs) have recently been identified as a mode of myokine transport from muscle, facilitating su...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106243

    authors: Maeshige N,Langston PK,Yuan ZM,Kondo H,Fujino H

    更新日期:2021-02-01 00:00:00

  • Propagation of elastic waves through two-dimensional lattices of cylindrical empty or water-filled inclusions in an aluminum matrix.

    abstract::The layer-multiple-scattering method is developed to study wave propagation through two-dimensional lattices of cylindrical inclusions in an elastic medium. The lattices are a series of periodically spaced infinite one-dimensional periodic gratings (or rows) of inclusions. The layer-multiple-scattering method allows t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.002

    authors: Robert S,Conoir JM,Franklin H

    更新日期:2006-12-01 00:00:00

  • Periodic shock-emission from acoustically driven cavitation clouds: a source of the subharmonic signal.

    abstract::Single clouds of cavitation bubbles, driven by 254kHz focused ultrasound at pressure amplitudes in the range of 0.48-1.22MPa, have been observed via high-speed shadowgraphic imaging at 1×10(6) frames per second. Clouds underwent repetitive growth, oscillation and collapse (GOC) cycles, with shock-waves emitted periodi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.06.011

    authors: Johnston K,Tapia-Siles C,Gerold B,Postema M,Cochran S,Cuschieri A,Prentice P

    更新日期:2014-12-01 00:00:00

  • The performance and design of ultrasonic vibration system for flexural mode.

    abstract::The matrix method for analyzing flexural vibration system is outlined. The displacement, stress and velocity gain of ultrasonic flexural vibration systems are investigated by transfer matrix method. A design method is given for flexural transducer and vibration system. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00034-2

    authors: Zhou G

    更新日期:2000-11-01 00:00:00

  • Ultrasonic wave fluctuations through tissue: an experimental pilot study.

    abstract::The fundamental role of the assumption of plane wave ultrasonic propagation in attenuation and scattering measurements on soft tissues is discussed. The evidence for and against the validity of the assumption is shown to be inconclusive. An experimental procedure for direct assessment, by measurement of the ultrasonic...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(88)90059-5

    authors: Aindow JD,Chivers RC

    更新日期:1988-03-01 00:00:00

  • Spectral analysis of Doppler ultrasonic decompression data.

    abstract::Several aspects of spectral analysis of bubble transients in Doppler ultrasonic decompression data are discussed. The computation of energy density spectra, using fast Fourier transform techniques for analyzing bubble transients, is described. Spectral analysis of data from probes implanted within animals, using a con...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(77)90026-9

    authors: Kisman K

    更新日期:1977-05-01 00:00:00

  • Investigations of the barbell ultrasonic transducer operated in the full-wave vibrational mode.

    abstract::In this paper, the resonance frequency equation and expression of displacement amplitude magnifications of a full-wave barber ultrasonic horn are obtained. By discussing the relationships between the displacement amplitude magnifications and the geometrical dimensions, the optimized design of the horn for the largest ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.12.006

    authors: Fu Z,Xian X,Lin S,Wang C,Hu W,Li G

    更新日期:2012-07-01 00:00:00

  • Analysis of second harmonic guided waves in pipes using a large-radius asymptotic approximation for axis-symmetric longitudinal modes.

    abstract::Theoretical formulation for the problem of second harmonic guided waves in pipes is presented from the principles of continuum mechanics. The formulation is carried out in the reference configuration of the pipe with an emphasis on the correct use of the "Divergence" operator in the reference configuration. Second har...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.12.007

    authors: Chillara VK,Lissenden CJ

    更新日期:2013-04-01 00:00:00

  • Numerical predictions and experiments for optimizing hidden corrosion detection in aircraft structures using Lamb modes.

    abstract::To increase the sensitivity of Lamb waves to hidden corrosion in aircraft structures, a preliminary step is to understand the phenomena governing this interaction. A hybrid model combining a finite element approach and a modal decomposition method is used to investigate the interaction of Lamb modes with corrosion pit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.02.004

    authors: Terrien N,Royer D,Lepoutre F,Déom A

    更新日期:2007-06-01 00:00:00

  • Lamb waves propagation in elastic plane layers with a joint strip.

    abstract::The Lamb waves are used for the ultrasonic characterization of welds because of their relative long-range propagation. In this paper, a simplified model of a weld-strip between two identical semi-infinite elastic layers is investigated. The reflected and transmitted ultrasonic fields are expressed by modal series whos...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.11.004

    authors: Predoi MV,Rousseau M

    更新日期:2005-06-01 00:00:00

  • Methods for reducing cutting temperature in ultrasonic cutting of bone.

    abstract::Ultrasonic cutting is widely used in food processing applications to produce a clean and accurate cut. However, it is yet to be adopted as an instrument of choice in orthopaedic applications, mainly due to the high temperatures that can be generated at the cut site and the consequent requirement to use additional cool...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.046

    authors: Cardoni A,MacBeath A,Lucas M

    更新日期:2006-12-22 00:00:00

  • New applications for ultrasonic sensors in process industries.

    abstract::Today, sophisticated instruments and algorithms used for process control allow the efficient production of substances with the quality guaranteed to the customer. However, production and management techniques are changing. This article aims to analyze trends resulting from those changes from the point of view of ultra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.047

    authors: Püttmer A

    更新日期:2006-12-22 00:00:00

  • The quasi-harmonic ultrasonic polar scan for material characterization: experiment and numerical modeling.

    abstract::Conventionally, the ultrasonic polar scan (UPS) records the amplitude or time-of-flight in transmission using short ultrasonic pulses for a wide range of incidence angles, resulting in a fingerprint of the critical bulk wave angles of the material at the insonified spot. Here, we investigate the use of quasi-harmonic ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.002

    authors: Kersemans M,Martens A,Van Den Abeele K,Degrieck J,Pyl L,Zastavnik F,Sol H,Van Paepegem W

    更新日期:2015-04-01 00:00:00

  • Numerical predictions and experiments on the free-plate edge mode.

    abstract::In this paper, te edge mode variation is studied with three different methods: the reciprocal work method, already used by Torvik [J. Acoust. Soc. Am. 41 (1967) 346] to model this phenomenon, the S-parameter method and a finite element model that are applied for the first time to the study of the edge resonance. Moreo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00391-8

    authors: Le Clezio E,Predoi MV,Castaings M,Hosten B,Rousseau M

    更新日期:2003-01-01 00:00:00

  • Bonding and impedance matching of acoustic transducers using silver epoxy.

    abstract::Silver epoxy was selected to bond transducer plates on glass substrates. The properties and thickness of the bonding medium affect the electrical input impedance of the transducer. Thus, the thickness of the silver epoxy bonding layer was used as a design parameter to optimize the structure for the transducer input im...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.11.010

    authors: Son KT,Lee CC

    更新日期:2012-04-01 00:00:00

  • Non-contact ultrasonic gas flow metering using air-coupled leaky Lamb waves.

    abstract::This paper describes a completely non-contact ultrasonic method of gas flow metering using air-coupled leaky Lamb waves. To show proof of principle, a simplified representation of gas flow in a duct, comprising two separated thin isotropic plates with a gas flowing between them, has been modelled and investigated expe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.04.008

    authors: Fan Z,Jiang W,Wright WMD

    更新日期:2018-09-01 00:00:00

  • An uncovered risk factor of sonothrombolysis: Substantial fluctuation of ultrasound transmittance through the human skull.

    abstract::Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. P...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.012

    authors: Wang Z,Komatsu T,Mitsumura H,Nakata N,Ogawa T,Iguchi Y,Yokoyama M

    更新日期:2017-05-01 00:00:00